The Complete Message:
For A13 structural system type, Building Height Class (BYS)> = 2 condition is not met in (X / Y) direction
The buildings specified as BYS = 1 in the article 3.3.2.2 of TBDY 2018 will be classified as high-rise buildings according to Section 13 .
Since the carrier system type A13 is selected and the BYS> = 2 condition is not met, the program gives a warning.
Table 3.3 - Building Height Classes and Building Height Ranges Defined According to Earthquake Design Classes:
|
Building Height Class |
Building Height Ranges Defined According to Building Height Classes and Earthquake Design Classes [m] |
||
|
DTS = 1, 1a, 2, 2a |
DTS = 3, 3a |
DTS = 4, 4a |
|
|
BYS = 1 |
HN > 70 |
HN > 91 |
HN >105 |
|
BYS = 2 |
56 <HN ≤ 70 |
70 <HN ≤ 91 |
91<HN ≤105 |
|
BYS = 3 |
42 <HN ≤ 56 |
56 <HN ≤ 70 |
56 <HN ≤ 91 |
|
BYS = 4 |
28 <HN ≤ 42 |
42 <HN ≤ 56 |
|
|
BYS = 5 |
17.5 <HN ≤ 28 |
28 <HN ≤ 42 |
|
|
BYS = 6 |
10.5 <HN ≤17.5 |
17.5 <HN ≤ 28 |
|
|
BYS = 7 |
7 <HN ≤10.5 |
10.5 <HN ≤17.5 |
|
|
BYS = 8 |
H N ≤ 7 |
H N ≤10.5 |
|
Solution:
Building design should be made according to the principles given in Chapter 13 of TBDY.