Minimum Spacing of Reinforcement per ACI 318-19 with ideCAD
How does ideCAD define minimum reinforcement space according to ACI 318-19?
Clear spacing is controlled automatically according to 25.2 for parallel reinforcement in a horizontal layer.
For longitudinal reinforcement in columns, pedestals, struts, and boundary elements in walls, clear spacing between bars is controlled automatically according to 25.2.3
Symbols
db = Nominal diameter of bar, wire, or prestressing strand, in.
Download ideCAD for ACI 318-19
Minimum spacing of reinforcement
According to ACI 318-19, for parallel reinforcement in a horizontal layer, clear spacing is controlled automatically at least the greatest of
1 in.
db
According to 25.2.3, for longitudinal reinforcement in columns, pedestals, struts, and boundary elements in walls, clear spacing between bars is controlled automatically at least the greatest of
1.5 in.
1.5db
Download ideCAD for ACI 318-19