Insufficient Reinforcement on Beam

This message is created at the beginning of the report by giving the element name and solid.

For example, K1 Ground. Floor Reinforcement Insufficient

In the element whose name and solid is given, it means that the reinforcement amount that will meet the reinforcement area calculated due to the design effects or the regulation could not be selected.

It may apply to longitudinal reinforcements, additions, stirrups, and body reinforcements in curtain wall.

Possible solutions:

Uncheck DS (reinforcement fixing) in the reinforced concrete dialogs.

  • In the Reinforcement Selection dialog, you can increase the reinforcement diameters available for the relevant element.

  • You can decrease the amount of reinforcement needed by increasing the dimensions of the relevant element.

  • In the element reinforced concrete dialog, you can give the required amount of reinforcement yourself by looking at which type of reinforcement the missing reinforcement has been created.