Skip to main content
Skip table of contents

Insufficient Reinforcement in Shearwall

This message is created at the beginning of the report by giving the name of the element and its solid.

For example, P1 1st floor Insufficient Reinforcement

In the element whose name and solid is given, it means that the amount of reinforcement that will meet the reinforcement area calculated due to the design effects or the regulation could not be selected.

Stirrups and crossties on the curtain can be valid for longitudinal reinforcements.

Possible solutions:

Uncheck the DS (reinforcement fixing) in the reinforced concrete dialogs.

  • In the Reinforcement Selection dialog, you can increase the reinforcement diameters available for the relevant element.

  • You can decrease the amount of reinforcement needed by increasing the dimensions of the relevant element.

  • In the element reinforced concrete dialog, you can give the required reinforcement amount yourself by looking at which type of reinforcement the missing reinforcement has been created.


JavaScript errors detected

Please note, these errors can depend on your browser setup.

If this problem persists, please contact our support.