Skip to main content
Skip table of contents

Transverse reinforcement spacing error

This message is created at the beginning of the report by giving the name of the element and its story.

For example, S1 1. story transverse reinforcement spacing error

In the element whose name and story is given, it means that the amount of reinforcement that will meet the reinforcement area calculated due to the design effects or the regulation could not be selected.

Stirrups and crossties in columns may be valid for longitudinal reinforcements.

Possible solutions:

Uncheck the DS (reinforcement fixing) in the reinforced concrete dialogs.

  • In the Reinforcement Selection dialog, you can increase the reinforcement diameters available for the relevant element.

  • In the element reinforced concrete dialog, you can give the required reinforcement amount yourself by looking at which type of reinforcement the missing reinforcement has been created.

  • Concrete and reinforcement class can be increased for the 1st and 2nd case.