[{"id":"ci_0d42a99bd1da37c8d4c50be137e27813135152bb20549f266044a195fd2f98af","title":"What Is Integrated Design for AEC","path":"/ideCAD/overview","children":[{"id":"ci_730bfaee926b5c03e1cfd30c64d151babd24719956a24657905017aa21a59650","title":"Integrated Design for Architecture Engineering Construction (AEC)","path":"/ideCAD/about-idecad","children":[]},{"id":"ci_7112521cf0e39ef91a0f202d76cc08ea7280350a851454e93558a21d06732d13","title":"What Does Integrated Design Mean for Architecture?","path":"/ideCAD/what-does-integrated-design-mean-for-architecture","children":[]},{"id":"ci_1a7388ace81c7e7473811ba0098663a2ddd1980a41f8889d347a0ffbcafdfb12","title":"What Does Integrated Design Mean for Structural Engineering?","path":"/ideCAD/what-does-integrated-design-mean-for-structural-en","children":[]},{"id":"ci_62e89e338099d350c7ecabf5634cea8936be96cc5e5d0f7a9f1b29bf1e81bf35","title":"What is the IDS Integrated Design System","path":"/ideCAD/what-is-the-ids-integrated-design-system","children":[]}]},{"id":"ci_fc0dfe85f394645c172ac02d6cb6822eae516fa5479143bd4ca8e0cf389ebde1","title":"Building Information Modeling","path":"/ideCAD/building-information-modeling","children":[{"id":"ci_bf19aefbeddac3cb84a6839b9f5a765a5f68e5da984d346df3327f088fdfd771","title":"What is Building Information Modeling (BIM)?","path":"/ideCAD/what-is-building-information-modeling-bim","children":[]},{"id":"ci_023133f59393970609f453b74eb98063aa1951510f1e8fbca0a9b6a71f88101b","title":"What is ideYAPI Integrated Design System (IDS)?","path":"/ideCAD/what-is-ideyapi-integrated-design-system-ids","children":[]},{"id":"ci_604bb0f6869fd65d9d7efe6d49ab346b63908d9f98d8c7bee0867fb2cb0f13ad","title":"Architectural Structural Teamwork with ideCAD","path":"/ideCAD/architectural-structural-teamwork-with-idecad","children":[]}]},{"id":"ci_ee20f36fb74766ac074ffd4ab4de516474bfa739c3105698f331adaefce71f2f","title":"Customize ideCAD","path":"/ideCAD/customize-idecad","children":[{"id":"ci_b6cefa96c159c5ddc08d0b05df4d8db0d37fef3ebd7546400e392250fc284caf","title":"Keyboard Shortcuts and Toolbars in Classic Menu","path":"/ideCAD/keyboard-shortcuts-and-toolbars-in-classic-menu","children":[]},{"id":"ci_1378ce1e91b969b7d3006142f80fc82bb97ce68c603b49af0dbee29963344dcc","title":"Keyboard Shortcuts  and Toolbars in Ribbon Menu","path":"/ideCAD/keyboard-shortcuts-and-toolbars-in-ribbon-menu","children":[]},{"id":"ci_03558af4ddc9456cc79347805a01c5366edaf8cd278c936c7423e9a19b3c4020","title":"Default Keyboard Shortcut","path":"/ideCAD/default-keyboard-shortcut","children":[]},{"id":"ci_c3dee23ee79359feec7d009171ccb965ad2cafc51eb78379088636729268a6a9","title":"Viewport Configuration","path":"/ideCAD/viewport-configuration","children":[]},{"id":"ci_55f96c1466225b65625e239ac00c0cfcc671754aaee6d7fc7048b4ddb8575477","title":"Project Settings","path":"/ideCAD/project-settings","children":[]},{"id":"ci_09b2c77fc52d6130555d2e0e9b86babee583a80eb0d0f6a99fb68c14a05a355f","title":"Preferences - ideCAD Settings","path":"/ideCAD/preferences","children":[{"id":"ci_77ff93bac43971199fc4f0fd4a7209678c23c405085bc1f9424c637d78740dde","title":"Preferences Tab","path":"/ideCAD/preferences-tab","children":[]},{"id":"ci_af695b4c9cdbf438854c0e59fac61f4c3947cd8c79476b627fa4c17d5b3afc7c","title":"Transparent Story Tab","path":"/ideCAD/transparent-story-tab","children":[]},{"id":"ci_6d1cc768bf184732aa5acaa4784f9622e1e51a80cba2a08c13bb3ef71229533e","title":"Viewport Configuration Tab","path":"/ideCAD/viewport-configuration-tab","children":[]},{"id":"ci_fce0da2094914c6e429caedbc3416464002eb7d0f1d41d4ce088129e15349027","title":"Input Units Tab","path":"/ideCAD/input-units-tab","children":[]},{"id":"ci_3ff6769f98d221726d8826bf381932ce96f686c56b49383abacbe02e586b5bba","title":"Design Units Tab","path":"/ideCAD/design-units-tab","children":[]},{"id":"ci_ec32d099290a49b01cca480febef8f8a643791bafa0105421bfc3b81aee6e173","title":"Project Information Tab","path":"/ideCAD/project-information-tab","children":[]},{"id":"ci_50caac7a821c93ec519614c0849e9a6a3b8d0ff25ab55cb661e9570a91dc5e29","title":"Materials Tab","path":"/ideCAD/materials-tab","children":[]},{"id":"ci_2876970c2dad48081bf7123b3d677d179920db60748d80fd6b91e787a498af10","title":"Profiles Tab","path":"/ideCAD/profiles-tab","children":[]},{"id":"ci_a8dc019938710c4a9232904ff32f4a639c2ae9793510eef69df34211569e9162","title":"Annotations Objects Tab","path":"/ideCAD/annotations-objects-tab","children":[]},{"id":"ci_cbb2af26808e08785a46f3222f36501ffedb13ee00ee698f2102bba1d4c110d7","title":"Composite Material Tab","path":"/ideCAD/composite-material-tab","children":[]},{"id":"ci_ed84a3eb0778c7b98bfcbe49c9becb3cc125960cfc0f3cdeede82b15f2a9f2e4","title":"RC Design Settings Tab","path":"/ideCAD/rc-design-settings-tab","children":[{"id":"ci_dbc6da6687b40ed90b5beb17f8e93e158ae3757e2bafe70402d79a39f7fc53a1","title":"General RC Settings Section","path":"/ideCAD/general-rc-settings-section","children":[]},{"id":"ci_893da963402321ae12fc422f097ea2d1ae01093ad751d3eebeb2157b0731c2cf","title":"Rebar Selection Section","path":"/ideCAD/rebar-selection-section","children":[]},{"id":"ci_1f304a143541fa72d59d208c2b9114d0a2ed500fb0fdced92065224ab7ad1877","title":"Mesh Wire Settings Section","path":"/ideCAD/mesh-wire-settings-section","children":[]},{"id":"ci_8f00f3d87b16cd7cf3a9b67e0b0d185173ad395202a968543ea8cb46d1746012","title":"Column Design Settings Section","path":"/ideCAD/column-design-settings-section","children":[]},{"id":"ci_5a0427e6975ee1ac23b2cb5a1e41d5260dc3607aca09bacf1a49ec4cdf9ef75a","title":"Beam Design Settings Section","path":"/ideCAD/beam-design-settings-section","children":[]},{"id":"ci_d249b3ded08fddd5b1fbc38b2432ff909120237acf709ccf37803005ad59a1b3","title":"Shearwall Design Settings Section","path":"/ideCAD/shearwall-design-settings-section","children":[]},{"id":"ci_a2283debbc46a38241d5a875a13a8e5ac43c0e2a39c00449484e5a25331b2685","title":"Slab Design Settings Section","path":"/ideCAD/slab-design-settings-section","children":[]},{"id":"ci_1e6cf03900384670157c116a66d3fdf16f4eafc0c561b0b67951d18e691a66f2","title":"Ribbed Slab Design Settings Section","path":"/ideCAD/ribbed-slab-design-settings-section","children":[]},{"id":"ci_c440f53a5e387bd8157ef4120769cb58c03648b3be33a6eb7320edb2942cb52b","title":"Single Footing Design Settings","path":"/ideCAD/single-footing-design-settings","children":[]},{"id":"ci_ca55377fec62631a3e64d7d3276c3bb465bf9976685a1d7db1510846db25a1f9","title":"Strip Foundation Design Setting Section","path":"/ideCAD/strip-foundation-design-setting-section","children":[]},{"id":"ci_56eb00f90f4f9073218e530aad66d0e83b478e8c70293beed3b08bfcb42d5738","title":"Raft Foundation Design Settings Section","path":"/ideCAD/raft-foundation-design-settings-section","children":[]},{"id":"ci_99b0e2370bd8f83a44bb8016c056d45ed4970a75d6da0864ee74f8e4f9fc0499","title":"Retaining Wall Design Settings Section","path":"/ideCAD/retaining-wall-design-settings-section","children":[]},{"id":"ci_d68d56969bad54552b7f40c3fa407d62bf21a13de6575ef299514a082873db6d","title":"Well Foundation Design Settings Section","path":"/ideCAD/well-foundation-design-settings-section","children":[]},{"id":"ci_5717e9617d2838a12cdbc53dd3c4434dcb8a7bb825c63e9cca87ab3442d57621","title":"Stair Design Settings Section","path":"/ideCAD/stair-design-settings-section","children":[]},{"id":"ci_ff2f087cabe2c5751945dbfc087b480ca6f315b39857c26ee9a0a1124f760400","title":"Pile Design Settings Section","path":"/ideCAD/pile-design-settings-section","children":[]},{"id":"ci_06188da7596e4b707471965e54b92ddf994c611efc2f2d24a52f5798d2fe771f","title":"Dome & Vault Design Settings Section","path":"/ideCAD/dome-vault-design-settings-section","children":[]},{"id":"ci_2d3c697719cc281f3ba94fe50d0a594661e69dcedd820b50907fa653bf6f57ee","title":"Foundation Tie Design Settings Section","path":"/ideCAD/coupling-beam-design-settings-section","children":[]}]},{"id":"ci_1a978b5b490d086eb690f5991e76886896f0dcca0b480061c6ed593a4a57f5f0","title":"Concrete Detailing Tab","path":"/ideCAD/concrete-detailing-tab","children":[{"id":"ci_cc72377d90459775965e92fb763b6f6890e9799e3b718deae05a9dc6691ca0e6","title":"Formwork Plan Detail","path":"/ideCAD/formwork-plan-detail","children":[]},{"id":"ci_a0a084af1958c93b03fb0464fa3a25db2b8e6232d7f6e10c56f6e6fe92f805b1","title":"Column Application Detail","path":"/ideCAD/column-application-detail","children":[]},{"id":"ci_a6722319d1a6ef2b31c2d61df4619c868f50bab929d182c242372ce81548e00d","title":"Shearwall & Column Vertical Detail","path":"/ideCAD/shearwall-column-vertical-detail","children":[]},{"id":"ci_076edb639579b123804d66f571c2154d1b3040874ea05d5bb38f34f079605e0d","title":"Beam Detail","path":"/ideCAD/beam-detail","children":[]},{"id":"ci_97092be1a2c6c0301b34d1ca283c3333f25beac1e76525988d9661982c47e9b8","title":"Rib Detail","path":"/ideCAD/rib-detail","children":[]},{"id":"ci_abebd8f5e770ec4df989694225afbf65d4f2c02e250aa965350b7c5ad5e36b21","title":"Waffle Detail","path":"/ideCAD/waffle-detail","children":[]},{"id":"ci_42351a861b24ce136f263dd2252129f6cd311790cb468d7c3923a703b16ae991","title":"Foundation Plan Detail","path":"/ideCAD/foundation-plan-detail","children":[]},{"id":"ci_3ab79f4ae93cadd257f75e52fb865393fddf351f193186b66088d308f35565d6","title":"Strip Foundation Detail","path":"/ideCAD/strip-foundation-detail","children":[]},{"id":"ci_a9d6aac66df5158592a25011485be786727eeffbad9c21dc4f9c8540910e6eb1","title":"Single Footing Detail","path":"/ideCAD/single-footing-detail","children":[]},{"id":"ci_438f2b2f97c34bb12533985553fb8d7d30feca7f62488c42e4f664a95a9e0874","title":"Foundation Tie Detail","path":"/ideCAD/connection-beam-detail","children":[]},{"id":"ci_60dfbee6f1f7864c463d580bbf0b4d6661a56b18e69c886f7198884899500d7b","title":"Column-Beam Joint Cross-Section Detail","path":"/ideCAD/column-beam-joint-cross-section-detail","children":[]},{"id":"ci_485dd18fb9a830d94b87c329ba7e5b2f89924622a33e8337d897bf6e003e0810","title":"Retaining Wall Detail","path":"/ideCAD/retaining-wall-detail","children":[]},{"id":"ci_53bedb85e62e858753c6ae0c24109b98c8582083eb5a455bd1c48e06df6e4e7b","title":"Well Foundation Detail","path":"/ideCAD/well-foundation-detail","children":[]},{"id":"ci_128b53f4735d622dcf672619cfd6e721256a7240ecdb8411f4880693d80cb12e","title":"Stair Detail","path":"/ideCAD/stair-detail","children":[]},{"id":"ci_932cd2753b8ac29cf8c26b82e54941ed7c0089e9f07be8ab62f891855537c030","title":"Pile Detail","path":"/ideCAD/pile-detail","children":[]},{"id":"ci_1f081d6c17e06d1fa6a3cf415e1fe04081e0e9821dd91256427240970ff03666","title":"Dome Detail","path":"/ideCAD/dome-detail","children":[]}]},{"id":"ci_8fad39c3aaf908a04f137e1b7c4a1a066763f5b532934cd6e22bfabcda560f7b","title":"Steel Detailing Tab","path":"/ideCAD/steel-detailing-tab","children":[]}]},{"id":"ci_e7d24c062f8720cca8afcd8142b127fea307d4795283ef34176f688425b2cb0f","title":"Apply Preferences Settings to All Windows","path":"/ideCAD/apply-preferences-settings-to-all-windows","children":[]},{"id":"ci_3f14061c9823d5efbda03a188efb45d16f34d5f97b88f27c8352856fd76f262b","title":"View Settings","path":"/ideCAD/view-settings","children":[]},{"id":"ci_d83c3a09a93cc15a1c85ec1d14a1dceae62d0e96ba8ab443a80bcac5a417e4ad","title":"Menu Settings","path":"/ideCAD/menu-settings","children":[]},{"id":"ci_caff61e91dcd079504998b550952fd136f277f825ddd0f2adfee293fe5554325","title":"Background Settings","path":"/ideCAD/background-settings","children":[]},{"id":"ci_4ae903521214b32719d74bf1498218634cc501d255439bf0a1235b5e775bcc45","title":"Background Colors in 2D and 3D Pages","path":"/ideCAD/background-colors-in-2d-and-3d-pages","children":[]},{"id":"ci_3fc304ac5a804fbe3c9593ab518d3f02e5ee51b1f45ccb58d5190863d06963ee","title":"Node Settings","path":"/ideCAD/node-settings","children":[]},{"id":"ci_c3cc39550b9cabbce865c4131a42f0b0a7ebc2733d3dd78137444f1f3caa7044","title":"Project Save Settings","path":"/ideCAD/project-save-settings","children":[]},{"id":"ci_17dac3d9d37bd805d817abd6b84518cfb1d3f3635ef315f5add264128f743e0c","title":"Story Settings","path":"/ideCAD/story-settings","children":[]},{"id":"ci_2f452d179a3a8517e6b4768142be514f6723f7231143bef945e8025ee4c7ab2a","title":"Project Templates","path":"/ideCAD/project-templates","children":[]},{"id":"ci_7aa54feec3267cf13760766348941054e8a091c8656827e46d48e9dab68c76dc","title":"Grid System","path":"/ideCAD/grid-system","children":[]},{"id":"ci_8e06a480ed3e16df44ea6fcf17204bddcfe9a7f1d97f1c971dc3e0d5304d91f3","title":"Helper Grid","path":"/ideCAD/helper-grid","children":[]},{"id":"ci_f63b52e1bd4c48c9e4a87b90d39d72e4c7e5a8d2e258d83918881a510b4f0258","title":"Drawing Limits","path":"/ideCAD/drawing-limits","children":[]},{"id":"ci_c9880b1c04e1b43785e25474ffae80f1127fd0c508cf3b23581b9bd1690a7c5b","title":"Plan Scale Settings and Monitor Selection","path":"/ideCAD/plan-scale-settings-and-monitor-selection","children":[]},{"id":"ci_9c6629413c3b234ed54bb16762f9c174eda2018ac5ca2f5e1467c9428eccf056","title":"Contour Line","path":"/ideCAD/contour-line","children":[]},{"id":"ci_a3449b0fbc5cc77a4af967ea970b24ce9d8e1e6f6b8fc0eb9b7bf4417c93b8d4","title":"Setting New Contour Lines","path":"/ideCAD/setting-new-contour-lines","children":[]},{"id":"ci_b38cd78a4abf6b4bd7b1a3c2d2c35a914af2ea2fbc5f8b01fefaa0cb3396306d","title":"Calculate Contour","path":"/ideCAD/calculate-contour","children":[]},{"id":"ci_daf7cadbff8ea88078e6df1744cc14b5853563f3523e6c84a509a93855466425","title":"Show/Hide Contour Lines","path":"/ideCAD/show-hide-contour-lines","children":[]},{"id":"ci_0000c622269cf7c92a6f4ef995c861218b1452acdc5fe0bc0d6bdf42ef6b7ab0","title":"Project Units","path":"/ideCAD/project-units","children":[]},{"id":"ci_bc817a995f2339838aefa173c6732a1a87983f4e7554e1674442ed6e4c1e18bd","title":"Polar Tracking and Dynamic Input","path":"/ideCAD/polar-tracking-and-dynamic-input","children":[]},{"id":"ci_31e21964dc77573bb83ff79536bebeef0c575ad264ab16a50895896c4eccc003","title":"Saving/Loading/Resetting Settings","path":"/ideCAD/saving-loading-resetting-settings","children":[]}]},{"id":"ci_a4fd7354ac96183dad20af54224bbdeb965aaf6f2b4a518e7d8ae9dfa0d5e933","title":"Get Started","path":"/ideCAD/get-started","children":[{"id":"ci_5cd1e48d710828633cbdd050a10b7aa3903d75d2e8a64affcdc5677d75727a25","title":"Download and Licensing","path":"/ideCAD/download-and-licensing","children":[{"id":"ci_e5980f8a0fe2d3b06ce6b485644bdc9ee9ec0323c3bfc345c63573560919eba6","title":"System Requirements","path":"/ideCAD/system-requirements","children":[]},{"id":"ci_418b5be9d23a80fe2138bb2a099260942aa9cafbe816826694e2637edfa3539b","title":"Download ideYAPI OneClick","path":"/ideCAD/download-ideyapi-oneclick","children":[]},{"id":"ci_7dc14b4ac35d9fa13e7943184d7f4b426d12658c42a13f320125b689d29d6b82","title":"How to create a MyAccount membership?","path":"/ideCAD/how-to-create-a-myaccount-membership","children":[]},{"id":"ci_b1401a4494e14e265a463f1a826a8c7be372581dd3ea370cff8ceb066cab4f7b","title":"Account Verification","path":"/ideCAD/account-verification","children":[]},{"id":"ci_eee3e40ede219ca6cfdcb46375bcec71e0368403c4dfe7c5a2f67c8879118c12","title":"ideYAPI OneClick","path":"/ideCAD/ideyapi-oneclick","children":[]},{"id":"ci_08ada5c85c09ddd47d73faf6b73b214d0421f7094dfffd4a8d5a28a979770650","title":"Account and Profile","path":"/ideCAD/account-and-profile","children":[]},{"id":"ci_3b292e0cf1ad8640ed4fd02187b7cc70b5a66159f4caba3821d2d97693747cf0","title":"Trial Activation","path":"/ideCAD/trial-activation","children":[]},{"id":"ci_b04867a1610a88b7769703bb857deca340e8cb23e8276731604b2eff6d716d1e","title":"How to Download Trial Version?","path":"/ideCAD/how-to-download-trial-version","children":[]},{"id":"ci_c3f1b00649ab2ecd216dcafe2295ab831bec2ea5cb5e9755885d6ea0ad7a3fc8","title":"Convert Active Trial License to Subscription","path":"/ideCAD/convert-active-trial-license-to-subscription","children":[]},{"id":"ci_a0bb95d5d80f842ccba88cba5621d29de24782b0e96384cfac55825b6d44b108","title":"Eligibility & Downloads for Students","path":"/ideCAD/eligibility-downloads-for-students","children":[]},{"id":"ci_f2854978bd4ece5e2edef51ffb06128b8f756e45d142a331661ca796dd11e865","title":"Educational License Activation","path":"/ideCAD/educational-license-activation","children":[]},{"id":"ci_e3693f336d404581a6d4f602d0e6aafbfef059df5e6dde775cd843e3705efe9e","title":"Convert Educational License to Subscription","path":"/ideCAD/convert-educational-license-to-subscription","children":[]},{"id":"ci_f2f86bdac234272c36c024b6a066c1af76dd5a3da9218396d090fd855d6c5435","title":"License Activation","path":"/ideCAD/license-activation","children":[]},{"id":"ci_f90b8716a64c2b32c773a9dcce0b9cf38a7cb766d7c570db5bb6213b53e03504","title":"How to Download Licensed Version?","path":"/ideCAD/how-to-download-licensed-version","children":[]},{"id":"ci_d3af484760ae5faf2178dd19a41add55bd5aff272d6f96110ecf2dd80af57d73","title":"To Transfer a License","path":"/ideCAD/to-transfer-a-license","children":[]},{"id":"ci_719f76ac09b5b0645c352dfdb06b0c7ffae211b5d96740159b4127b798f9f51f","title":"Software on CD, DVD, or USB","path":"/ideCAD/software-on-cd-dvd-or-usb","children":[]},{"id":"ci_0f785c5819a2eb5983fb3d830eced53e0b3624fd65bf1060754cb70d6a90e407","title":"Issues with Downloading","path":"/ideCAD/issues-with-downloading","children":[]},{"id":"ci_a806c05d79144e8bb67f1ec62400554d36dc120f40bfd09e94f8f5c13b8bec03","title":"FAQ About ideYAPI OneClick","path":"/ideCAD/faq-about-ideyapi-oneclik","children":[]}]},{"id":"ci_deb294b4e8967025ab07b2c4c9fbd38c71bfac85e6af64a783d93a1953d8f8e1","title":"Questions About Buying","path":"/ideCAD/questions-about-buying","children":[{"id":"ci_781dca087732bd46f7155ca04e2ab27f369accd37d5de5e84b67930f712f4c39","title":"About Subscriptions","path":"/ideCAD/about-subscriptions","children":[{"id":"ci_842d18544a918e9df5da794f340ca7a3c44426d898fedeb5715d556b9f69f3d5","title":"Compare Subscription License Plans","path":"/ideCAD/compare-subscription-license-plans","children":[]},{"id":"ci_886b90bda97042e4a833a09214a1a6ecc323acf1fe2f575743d497c861635fe5","title":"Subscription Licensing Options","path":"/ideCAD/subscription-licensing-options","children":[]},{"id":"ci_3cdf2aec0f719ed83af4a0f3dc6e0eda5ab07a70ad8ed4cd0659feec2a23c58c","title":"Non-Subscription (Perpetual License) Software","path":"/ideCAD/non-subscription-perpetual-license-software","children":[]}]},{"id":"ci_b7b898b9d56ba44d0c807f522cf505ef4828119c620f6dd016840a6e317846af","title":"About Buying","path":"/ideCAD/about-buying","children":[{"id":"ci_ba7354552cf08846e49353cfeaf27a46b07d0e29c6938f7552020a8ddcad84e3","title":"Buying on Online Store","path":"/ideCAD/buying-on-online-store","children":[]},{"id":"ci_8b1e88a445be078a5eef8abac4b9f4a775d7f74d6a76b6e3496aa8548e60ff44","title":"Buying a Multi-User License","path":"/ideCAD/buying-a-multi-user-license","children":[]}]}]},{"id":"ci_5778ab4f07943f7588bc7f24e1e10f45b30f4885a9d0ddbb365fbbe8a296f1bf","title":"User Interface","path":"/ideCAD/user-interface","children":[{"id":"ci_b77d7c20d9da3c7b35bbf1606de1a4d32a2a3e77c90b1cc3ff88872a434ab5dc","title":"Running the ideCAD for the First Time","path":"/ideCAD/running-the-idecad-for-the-first-time","children":[]},{"id":"ci_fb45471f0b77f8fb4a203b7ba7a6b20cc16ee2d89ce5641a99e9c0951fff767a","title":"Start Page","path":"/ideCAD/start-page","children":[]},{"id":"ci_bfc6db63e4330bf32c74aa82b8c37c1934d14ec12a42fbc0ed61c8326fd37679","title":"General View","path":"/ideCAD/general-view","children":[]},{"id":"ci_ddbe997a089f17b6a94c906ac95b7a1c14ccee124a38cfa2d28c920c0c9599a3","title":"Ribbon Menu Layout","path":"/ideCAD/ribbon-menu-layout","children":[]},{"id":"ci_172e4c539ed295cd691b1afc91013845005c3b97eee9c44e200ec47b218522db","title":"Classic Menu Layout","path":"/ideCAD/classic-menu-layout","children":[]},{"id":"ci_8af4d53c56b83ee94c104dbfae636f237c8333dbac3d8dbd83873d2326742801","title":"Vertical Toolbar","path":"/ideCAD/vertical-toolbar","children":[]},{"id":"ci_b24281f36c53b11524d9d9477539f0e95d43a146512e11aec315911fd3f7465a","title":"Use Right Button for Context Menu","path":"/ideCAD/use-right-button-for-context-menu","children":[]},{"id":"ci_e1048d4d9ee23e5adcebc89bdad6af55215609f15bdbfb7d2180e65d921269a2","title":"Toolbars and Command Buttons","path":"/ideCAD/toolbars-and-command-buttons","children":[]},{"id":"ci_6b48e1f3558cacd1cfab70fec05cc3c1a07c8aeb254c861d042cda260c114ea1","title":"Message and Information Lines","path":"/ideCAD/message-and-information-lines","children":[]},{"id":"ci_cdf1d619ca37bce469fc4606a5923a2c952207b4fcaa843a22025a165b93651c","title":"Alias (Command Line) Editor","path":"/ideCAD/alias-command-line-editor","children":[]},{"id":"ci_5bc22ea78b9845cb09480d97714f31c9b0240264f849a162bc54be111090ceac","title":"Coordinate Box","path":"/ideCAD/coordinate-box","children":[]},{"id":"ci_bf69718f52c1766e528efb7514adc557dc5e6703313e24f5e2055691722ef39a","title":"Building Structure Tree","path":"/ideCAD/building-structure-tree","children":[]},{"id":"ci_f23376a15a441929febd797751356ae86dca4cf6a443b154960e4b6995630558","title":"Information Box","path":"/ideCAD/information-box","children":[]},{"id":"ci_6686d4a513256722eaeae4b4c48ea407e438f8a4bc0ee765cdb1ba5f7b452301","title":"Automatic Scaling of Ribbon Icons","path":"/ideCAD/automatic-scaling-of-ribbon-icons","children":[]},{"id":"ci_e1f0b155bf5f53dfcb3d27880bb4c0d3520bfb552b987154f574fe028a649e45","title":"Dialogues","path":"/ideCAD/dialogues","children":[]},{"id":"ci_c0d851abd9ec3c7d3192dce509bc8db55d209a499efd60a6b11a6e98374023d4","title":"Searching in the Dialogue","path":"/ideCAD/searching-in-the-dialogue","children":[]},{"id":"ci_a1e46d5a38496bf2400861ec98b7add3d91a4ac5fc07de42157ffd83a39fd051","title":"Changing Working Unit in Dialog","path":"/ideCAD/changing-working-unit-in-dialog","children":[]},{"id":"ci_e81d0818af7ec87421554ff7cee771930dd02dc33ed0abee2542a6fa28292aa1","title":"Drawings","path":"/ideCAD/drawings","children":[]},{"id":"ci_d05d50a18f83d26d03cfadd4eb64ff4bbbe183d5a637355e4a8c3db92def574b","title":"Story List","path":"/ideCAD/story-list","children":[]},{"id":"ci_d9c67b2f0ef2a72536438a48a887c46c7e9ed25db899c4368c3b3416526b8318","title":"Entity Properties","path":"/ideCAD/entity-properties","children":[]},{"id":"ci_85bb235e16e63d890c396d3dd0d94f6ae318bd72f5614700f4730eddb80cecf2","title":"List of ideCAD Architectural Commands","path":"/ideCAD/list-of-idecad-architectural-commands","children":[]},{"id":"ci_0aa74688951a775de64578ca62dc1e45b7c5db39863ca60a31450c8686ad2903","title":"List of ideCAD Structural Commands","path":"/ideCAD/list-of-idecad-structural-commands","children":[]}]},{"id":"ci_48071651c8f9990eb58d329ec9fed860ab8da05a447e0339c56f4d5b8b1dbbaf","title":"Creating the One Model","path":"/ideCAD/creating-a-one-model","children":[{"id":"ci_dd025115a85f7dc6d0ca0f1b1118f048fc5124a4c6e98cf8e61003be5f77d374","title":"Create a Project","path":"/ideCAD/create-a-project","children":[]},{"id":"ci_f7313c16763a2b79adfc8021e0dd5a36f75befbe434bfa3eb912449e6b50c0ed","title":"Create Lot Lines","path":"/ideCAD/create-lot-lines","children":[]},{"id":"ci_5b601d2072589be1cab32ac209a8520dc4fcd287a06e6ff449833668cd158509","title":"Create the Axes","path":"/ideCAD/create-the-axes","children":[]},{"id":"ci_bbd7d1c44dbb36a34dc5d076faa2a2ade863259409f25c5c31b7995d2dcbfd15","title":"Create Walls","path":"/ideCAD/create-walls","children":[]},{"id":"ci_725c68e1b042180d4e41f74b98deefbae6ef5ce83df8ad5d8deaad1712e6a5c7","title":"Create the Columns","path":"/ideCAD/create-the-columns","children":[]},{"id":"ci_402054b4b3b3511d4946ea32fa022cd8a1bb0e90afa2472d4d2284f5058893a2","title":"Create the Zones","path":"/ideCAD/create-the-zones","children":[]},{"id":"ci_19b8c2ec722edc86b82baf58167a7b19434a0a4aadebf6a26dda102c0221ef40","title":"Create the Beams","path":"/ideCAD/create-the-beams","children":[]},{"id":"ci_694bcd95f878284e57261647a0f1c847d26f16770047a5161799ce555f9cfef0","title":"Create the Slabs","path":"/ideCAD/create-the-slabs","children":[]},{"id":"ci_ed6381260a89cab92f05489353eb378ee59f343c92abbe00170c623861264216","title":"Place Doors","path":"/ideCAD/place-doors","children":[]},{"id":"ci_f96e12a1c08800d2270eb5384ec0961c113f01e1f71200b60e290604739c1800","title":"Place the Windows","path":"/ideCAD/place-the-windows","children":[]},{"id":"ci_3ea9251e5d72dc0a3093222021210abc46547717e9b1dd468674429d13fd8f51","title":"Create the Curtain Wall","path":"/ideCAD/create-the-curtain-wall","children":[]},{"id":"ci_bc13ea459100b08b2fee6393a08bcba39fe8c1080daf772f6bf883e4e6ec0ea6","title":"Copy Base Story to Upper","path":"/ideCAD/copy-base-story-to-upper","children":[]},{"id":"ci_83aeccf52770225f69473b339b207ed0f1722b1ed2775974680498d81b6e9123","title":"Create the Upper Story Walls","path":"/ideCAD/create-the-upper-story-walls","children":[]},{"id":"ci_dff1bc4585d6abe2e2aa42fd0d9760971b35f5c844f840d22317965da9db11fc","title":"Create the Upper Story Zones","path":"/ideCAD/create-the-upper-story-zones","children":[]},{"id":"ci_59a87c6568b3ccf3bf52eb7c6d0fc2346dd3f436efe9d689b4d7897bae5a8dac","title":"Create the Upper Story Beams","path":"/ideCAD/create-the-upper-story-beams","children":[]},{"id":"ci_f2ba09d41f52d7cb6d1b733afe8d50a243f111685d00c7d0f299aef293117cf2","title":"Create the Upper Story Slabs","path":"/ideCAD/create-the-upper-story-slabs","children":[]},{"id":"ci_f267e331cf7bc3c5dfd584c6fc75f35db26e70c519ba0f848a9ea3a5f6544c15","title":"Place the Upper Story Doors","path":"/ideCAD/place-the-upper-story-doors","children":[]},{"id":"ci_db0d00a79ef5a8a9b605728b9eff35bc98bb2cad6b39f21bc3c5bdb2a49d2e13","title":"Create the Stairs and Railings","path":"/ideCAD/create-the-stairs-and-railings","children":[]},{"id":"ci_ece3f2159b6c1d9a2b72fc83cc410de99994910cb79ab2378f9694a2dd6efca1","title":"Create the Patio Railings","path":"/ideCAD/create-the-patio-railings","children":[]},{"id":"ci_0351bae5cd996ab0270a2d9f4732e4479ca5187e6e213e3b92363fbf760641ac","title":"Create the Steel Columns","path":"/ideCAD/create-the-steel-columns","children":[]},{"id":"ci_45a3028e9c340b69afd0aaf31e7421a33ae85bd903b1db26f89c839b898b5b10","title":"Create the Steel Beams","path":"/ideCAD/create-the-steel-beams","children":[]},{"id":"ci_affef59149d08654903e0ffe4a4ddc2a9cc34df9308c2b3584e1ad432f496cf9","title":"Create the Steel Purlins","path":"/ideCAD/create-the-steel-purlins","children":[]},{"id":"ci_5b678d731b716b8180fd001a5033013bf2285fe5e33e67dc6f1da0c75833d44d","title":"Create the Sheetings","path":"/ideCAD/create-the-sheetings","children":[]},{"id":"ci_57ef18c0f7bd0ed69d7ea7db37a4d1e7e01f7eddc38c92ce21f08101c3b098d7","title":"Create the Roof","path":"/ideCAD/create-the-roof","children":[]},{"id":"ci_d0f50e45399f6eb94691c4eedc0ce831b9232d018970851704680c140f0622a9","title":"Create the Gutter and the Rainwater Pipe","path":"/ideCAD/create-the-gutter-and-the-rainwater-pipe","children":[]},{"id":"ci_ab10221a487b70d0ed9682431973aab03bc2e60535c9fc80ec59fd04ffc66bdc","title":"Create the Raft Foundation","path":"/ideCAD/create-the-raft-foundation","children":[]},{"id":"ci_9c78766e16820f7a496c896b97b05dfd617fb9513e222f0aa007744942c4ea47","title":"Create the Terrain","path":"/ideCAD/create-the-terrain","children":[]},{"id":"ci_4f2b8f8352e773f67276bbd8b267c66e5235f15a339768be33c809b349deb969","title":"Create the Swimming Pool","path":"/ideCAD/create-the-swimming-pool","children":[]},{"id":"ci_a23eade80f31d5d25340079535c610116ce46bf3a19da5555151b66ef42ebd93","title":"Create the Facade Elements","path":"/ideCAD/create-the-facade-elements","children":[]},{"id":"ci_07ab5c4404384d43eb0bf16e1c796e989ccf571c432a19490db3a85a4a86b32e","title":"Place the Furnishings","path":"/ideCAD/place-the-furnishings","children":[]},{"id":"ci_235ec818c0677f2bfe4eb56c707674175f9235eabdcd1d9d0758fb8dc60fa6f0","title":"Create the Horizontal Plan Section","path":"/ideCAD/create-the-horizontal-plan-section","children":[]},{"id":"ci_ee00b3b626b8fbfac09fe024b82a4120732b85d94a5758ade5dca781b30666f5","title":"Create the Section and Elevation Views","path":"/ideCAD/create-the-section-and-elevation-views","children":[]},{"id":"ci_4a5c424a97eb492e3086d94616518cbfcacbd3f3abe0add821c38cb149a88987","title":"Add Dimensions","path":"/ideCAD/add-dimensions","children":[]},{"id":"ci_d9384c20cef0d8387559295921a730eca935faa669c97935a952a6a556803a31","title":"Create the Layout","path":"/ideCAD/create-the-layout","children":[]},{"id":"ci_7767ad5e4b7aefb9fb0f16557474eefa4efb8b5ccc380966485f196fb1fe0aa7","title":"Create the Render","path":"/ideCAD/create-the-render","children":[]},{"id":"ci_6da9948bb96cbc0d734a4b2892ccc2f64aab8925de874253ee60e2a927ef2ed9","title":"Create the Animation","path":"/ideCAD/create-the-animation","children":[]},{"id":"ci_29ab21410a23556056abe02f9ada014e9e146e6691f184cbd9cf718b5a83274d","title":"Collaborate the ideCAD One Model","path":"/ideCAD/collaborate-the-idecad-one-model","children":[]}]},{"id":"ci_080017fc1b82930abdc7bd010e1d2a1031a347f3a4a35c50d99fb2978afc5577","title":"Collaborate the One Model","path":"/ideCAD/collaborate-the-one-model","children":[{"id":"ci_522565a7bb92e4bd62af0edd8fa16904ce53b1da77eb8b0bceccb56d11217640","title":"Collaborate Using the ideCAD One Model","path":"/ideCAD/collaborate-using-the-idecad-one-model","children":[]},{"id":"ci_978767bdb5b983cf097019bbe07386ac7c10c4176ef096550b1739c85904905a","title":"Collaborate Using IFC","path":"/ideCAD/collaborate-using-ifc","children":[]},{"id":"ci_7bde971cbe206735c2f7beef9282e170ff1132e240ab3532d7c616fe53e43d7a","title":"Collaborate Using DWG/DXF","path":"/ideCAD/collaborate-using-dwg-dxf","children":[]}]},{"id":"ci_ce0405697e780da4e6350fb17b3f58619bb4a184fc9322152ac05cbe3b6a05cd","title":"Structural Bim","path":"/ideCAD/structural-bim","children":[{"id":"ci_f917d6e75b8ae8eb3c57c2a0e5de27bd2403e4d11194c9a0eb74e2ff03d67ea2","title":"Architectural Structural Integration","path":"/ideCAD/collaborate-with-others","children":[{"id":"ci_c70567c324b1c8745599597e991b4341e5bc88b4dd23db3b6886bd6ee80cbf83","title":"Get the ideYAPI Building Information Model","path":"/ideCAD/get-the-ideyapi-building-information-model","children":[]},{"id":"ci_695f3eb9e5a12fc469e5e66530d2eaa3ed9269cd230a840fabcc10eca944b74d","title":"Get the IFC Building Information Model","path":"/ideCAD/get-the-ifc-building-information-model","children":[]},{"id":"ci_147eebf542b3e8dd3ae6ce61d58e7c520abd0a95341c5ad6e0c78ad23cdee489","title":"Get the 2D / 3D Drawings","path":"/ideCAD/get-the-2d-3d-drawings","children":[]},{"id":"ci_db2a92ca190a5e028d9f66e42fdfd4fe3460ac7c1ca23e227b8c7a3ffeaba377","title":"Create a New Structural Building Information Model","path":"/ideCAD/create-a-new-structural-building-information-model","children":[]}]},{"id":"ci_ae55710cc5e31faca882c1916b90b74cdb03f324067ee28ae0cf397d9974e115","title":"Examine the Structural Model","path":"/ideCAD/examine-the-structural-model","children":[]},{"id":"ci_e05b0d34f56a0ecbd3e338702189acaa1c77f0af60c7d9e343bd3eb5ce0129e2","title":"Set Project and Building Code Options","path":"/ideCAD/set-project-and-building-code-options","children":[]},{"id":"ci_834a0a50cdfb86a5d3be0e54a914b3c51e8deab885daaa65dd7ff3bc0ef7988e","title":"Use the Wizard for Analysis Settings","path":"/ideCAD/use-the-wizard-for-analysis-settings","children":[]},{"id":"ci_1aa1b6b21b536f6a08c0155443ec24e130ad3a9a2cc4fcb6c7d1b9376d9c5fb0","title":"Optimize the Structural System","path":"/ideCAD/optimize-the-structural-system","children":[]},{"id":"ci_cb1fd37ccef38b00ac0495d836ea4a73e38ace3ef14b12ba10cb926d46a5412e","title":"Check Geometry and Failure","path":"/ideCAD/check-geometry-and-failure","children":[]},{"id":"ci_731f3f510d1b7b6199434e5ae9ee4b0ee1b25f82eeca3d7d8103da56a017398d","title":"Fix the Failures","path":"/ideCAD/fix-the-failures","children":[]},{"id":"ci_1b696c9746f5d768cebe5d0256234a5424e00e5704b95530249a95f35efa65f4","title":"Structural Analytical Model","path":"/ideCAD/structural-analytical-model","children":[]},{"id":"ci_48d3e7cbdc339cd14ba8ea1aeded1a5d79f600ac6be5673cd69b5c736b864daf","title":"Architectural Load Model","path":"/ideCAD/architectural-load-model","children":[]},{"id":"ci_0d2dc917541182995affccf64f41c2fc2399b7b4b3ed0ba9b0d19f7463f6fbf3","title":"Analysis and Design","path":"/ideCAD/analysis-and-design","children":[]},{"id":"ci_073f4bf2db00a162fef813b980ca43b05c6a9e4fc90def87fae22c40b44b19a5","title":"Review Analysis Results","path":"/ideCAD/review-analysis-results","children":[]},{"id":"ci_5c359fb592848e7f37ddfc281702632866b68e540b7eb2ae1a34a1fc576b99fa","title":"Review Concrete Design","path":"/ideCAD/review-concrete-design","children":[]},{"id":"ci_dc624e6f18d9f95abe88b20daf45610f172f04ea56bbfa5410241d98a3a259d9","title":"Review Steel Design","path":"/ideCAD/review-steel-design","children":[]},{"id":"ci_0468173fa586c98576e257268b7b2ec370cac7ebaa35dd07b4e171f4f9d9d137","title":"Modelling Steel Connections - 1","path":"/ideCAD/modelling-steel-connections-1","children":[]},{"id":"ci_3d7a9ed48ae89360d305ba8b7eef45a76b4f4c919b5991eb145df910af0554da","title":"Modelling Steel Connections - 2","path":"/ideCAD/modelling-steel-connections-2","children":[]},{"id":"ci_7dd0f175fa5681e37fdce2bc77a17ad738f70569c241f716604d021695ee6625","title":"Generate Select Reports","path":"/ideCAD/generate-select-reports","children":[]},{"id":"ci_dba0234cd5dc795b106292bf4f91ae799d02051611afc3bfa8680c10093d4de7","title":"Generate Concrete Design Reports","path":"/ideCAD/generate-concrete-design-reports","children":[]},{"id":"ci_293559927a996731bafa67c9e27ca1d9310c4cd2a9382a98ce1bbaa9bd0be7a7","title":"Generate Steel Design Reports","path":"/ideCAD/generate-steel-design-reports","children":[]},{"id":"ci_bd019d44a82e948f2a166e8c62e20e229b72294f6bffce35d4f1f22dac45394d","title":"Create Concrete Drawings","path":"/ideCAD/create-concrete-drawings","children":[]},{"id":"ci_6b42bb96ef1e2a7dfdc622404e4e600ad4c80d8089c58e80882d8829e5761e7d","title":"Create Steel Drawings","path":"/ideCAD/create-steel-drawings","children":[]}]},{"id":"ci_b62b2a003172936c47c03d70e0ccc837eb53e802e8f38946d532b3a05a18219e","title":"Tutorial Videos","path":"/ideCAD/tutorial-videos","children":[{"id":"ci_c96786189fde1cd522c139150f84d4ec43c2b86cbe970b2e3a27f590b25b73c7","title":"Part 1. Create a Project","path":"/ideCAD/part-1-create-a-project","children":[]},{"id":"ci_8b48834676abe2f6d84f38f32c92cd267ffb07367dd643f2485da7e874cfaeff","title":"Part 2. Create Lot Lines","path":"/ideCAD/part-2-create-lot-lines","children":[]},{"id":"ci_23ec7352604fe8a12dcaac01264b414675cc17f7551968e7702f988d71c1da76","title":"Part 3. Create the Axes","path":"/ideCAD/part-3-create-the-axes","children":[]},{"id":"ci_dcf9b0f9d0aee817d141ff594c3a65b9d623d7b5d2ce0db9f46d3bfb5a81226a","title":"Part 4. Create Walls","path":"/ideCAD/part-4-create-walls","children":[]},{"id":"ci_2a747718150bdc9cc81896108a948cd3e74055480d4074f98492a34e8f7b95ac","title":"Part 5. Create the Columns","path":"/ideCAD/part-5-create-the-columns","children":[]},{"id":"ci_e4af754eb8569327f4abae22d61e4c3e45b4d94329b683803e284e263218f8c7","title":"Part 6. Create the Zones","path":"/ideCAD/part-6-create-the-zones","children":[]},{"id":"ci_7fbcbd3e21163363d902aadb913e33048febd6ef89dcd935a990bfe0a1ec8190","title":"Part 7. Create the Beams","path":"/ideCAD/part-7-create-the-beams","children":[]},{"id":"ci_ca7909a37d88e4c67ea26e6b0f3c32decb2f93300f0de82d76ff54addc558e2e","title":"Part 8. Create the Slabs","path":"/ideCAD/part-8-create-the-slabs","children":[]},{"id":"ci_9f5533535135b6b33fafd7f1831c539628abb3343d07e13bac3f9b339289ec98","title":"Part 9. Place Doors","path":"/ideCAD/part-9-place-doors","children":[]},{"id":"ci_a05bdca4da2a06edd8a59404b68b2faa114230beb00c3d6ee5cb9623df63d8eb","title":"Part 10. Place the Windows","path":"/ideCAD/part-10-place-the-windows","children":[]},{"id":"ci_7417f1e47cb8c36c0430a2cca742284fe4d7322d1a65324461cb6189d7b58d42","title":"Part 11. Create the Curtain Wall","path":"/ideCAD/part-11-create-the-curtain-wall","children":[]},{"id":"ci_db0bb6dca6d5de57028f6693a1c05a0ef36a8a7ac78ac8d2b45fa7648a9e1051","title":"Part 12. Copy Base Story to Upper","path":"/ideCAD/part-12-copy-base-story-to-upper","children":[]},{"id":"ci_f1b61b10b446cf198a8cb795c37a793da364506f9408b7dd7a7ef376d4f84002","title":"Part 13. Create the Upper Story Walls","path":"/ideCAD/part-13-create-the-upper-story-walls","children":[]},{"id":"ci_e61765fe58b83fa1e824f002176291e53ff28852901c7696c433b526704f5519","title":"Part 14. Create the Upper Story Zones","path":"/ideCAD/part-14-create-the-upper-story-zones","children":[]},{"id":"ci_22cc18bc450ddd3d40655df2ed0bdb8f9b2bade241cd54eedeb9ec4f86991f5a","title":"Part 15. Create the Upper Story Beams","path":"/ideCAD/part-15-create-the-upper-story-beams","children":[]},{"id":"ci_f312946b6f1d86f1a6bba1edd46ee741be82575cbbb11ef2f30dd08c5c027f5d","title":"Part 16. Create the Upper Story Slabs","path":"/ideCAD/part-16-create-the-upper-story-slabs","children":[]},{"id":"ci_ffb156672672fac168e1cf1581497cb9296d57ef1fbe2bf859b7fd6a4818e6ee","title":"Part 17. Place the Upper Story Doors","path":"/ideCAD/part-17-place-the-upper-story-doors","children":[]},{"id":"ci_a1ccfae0a33f1996f33c7bf450666c39e8f7bb1deac9af6faea2818b8a8844a1","title":"Part 18. Create the Stairs and Railings","path":"/ideCAD/part-18-create-the-stairs-and-railings","children":[]},{"id":"ci_5f3b199aeb8892cada021bbb5cf46a7f2f03a62c371acf933aaefcf393b217e2","title":"Part 19. Create the Patio Railings","path":"/ideCAD/part-19-create-the-patio-railings","children":[]},{"id":"ci_83df8b6de08a394451ddf33cbaf65c97b3afe578e775f39a0c58309a868b3fa5","title":"Part 20. Create the Steel Columns","path":"/ideCAD/part-20-create-the-steel-columns","children":[]},{"id":"ci_a91d9b465315274ee98c7fa0e71ed328da8d0f88edcf20262d519c3ccb8ad4e4","title":"Part 21. Create the Steel Beams","path":"/ideCAD/part-21-create-the-steel-beams","children":[]},{"id":"ci_bd86bc215e0b61fbd191a6604d3d7985f6e1f110f451078f185f5909a6528e9e","title":"Part 22. Create the Steel Purlins","path":"/ideCAD/part-22-create-the-steel-purlins","children":[]},{"id":"ci_7bab689d6868294a269b8f6246a8ff54bf8df3129c7bb64dd5e2db419bd081a8","title":"Part 23. Create the Sheetings","path":"/ideCAD/part-23-create-the-sheetings","children":[]},{"id":"ci_5ac05845e99e76d2f4dead7f047e6ce90b1a5769bb8b17d98ba1ab7acfd3dce0","title":"Part 24. Create the Roof","path":"/ideCAD/part-24-create-the-roof","children":[]},{"id":"ci_f24505c0453b4f0bc18783cddca27fe5b016fec576db998a26d31db4cc243e7c","title":"Part 25. Create the Gutter and the Rainwater Pipe","path":"/ideCAD/part-25-create-the-gutter-and-the-rainwater-pipe","children":[]},{"id":"ci_774390310fb61e3076de7025c1b72248df89df89685d118b350502571702b7cd","title":"Part 26. Create the Raft Foundation","path":"/ideCAD/part-26-create-the-raft-foundation","children":[]},{"id":"ci_46494a01d30fdb8861606df722351117eb3d75d3ea2966c8b66365212955eed4","title":"Part 27. Create the Terrain","path":"/ideCAD/part-27-create-the-terrain","children":[]},{"id":"ci_54af728111da619156f19b2dacf6a5bc3b9f584739164c872d44eb62f1063874","title":"Part 28. Create the Swimming Pool","path":"/ideCAD/part-28-create-the-swimming-pool","children":[]},{"id":"ci_524763cae6ccbecd01d4827e629edb0b1dde3a39cb8af3c276864799b1d28703","title":"Part 29. Create the Facade Elements","path":"/ideCAD/part-29-create-the-facade-elements","children":[]},{"id":"ci_450be66e53dbf4cd9e7a3061a27b7f8262d57ce3072488142020237b70d6fa42","title":"Part 30. Place the Furnishings","path":"/ideCAD/part-30-place-the-furnishings","children":[]},{"id":"ci_44a688fee5ca18ec3dea5ce5752472c49588e942ab6a060baaf1d18b124cb110","title":"Part 31. Create the Horizontal Plan Section","path":"/ideCAD/part-31-create-the-horizontal-plan-section","children":[]},{"id":"ci_f7c892eb93f272e0cfc557a4b1aa8c501634df2c640a1e6f99793486d5a87ddc","title":"Part 32. Create the Section and Elevation Views","path":"/ideCAD/part-32-create-the-section-and-elevation-views","children":[]},{"id":"ci_0c339702e7cd7e47c0887af5c81b9e8ec46c02a556c804a471240db75b51afa8","title":"Part 33. Add Dimensions","path":"/ideCAD/part-33-add-dimensions","children":[]},{"id":"ci_24038afd962ec7c3a571d44246ccb30cdb9f8c5d0ee5b2de94299bebc2e8b3cd","title":"Part 34. Create the Layout","path":"/ideCAD/part-34-create-the-layout","children":[]},{"id":"ci_4ebf2523719e77d97a552962c52f2c6ba562031eaa67d268f3d094d626de42b7","title":"Part 35. Create the Render","path":"/ideCAD/part-35-create-the-render","children":[]},{"id":"ci_b458054b5aa7b9633febc682d812ac93ea008275b2d0fcf32bb3e73fa1ed0a68","title":"Part 36. Create the Animation","path":"/ideCAD/part-36-create-the-animation","children":[]},{"id":"ci_176c0076366ac40d48d323de28ad5d0eb624eab5ad1bac789bc26e2d34e64297","title":"Part 37. Collaborate The ideCAD One Model","path":"/ideCAD/part-37-collaborate-the-idecad-one-model","children":[]},{"id":"ci_1978b6f567104e0adfd6ff03601a4f1eab159e7b0fee50192f6da34e7d88914a","title":"Part 38. Get the ideYAPI Building Information Model","path":"/ideCAD/part-38-get-the-ideyapi-building-information-model","children":[]},{"id":"ci_efac2bd5f3e3feeef2a1ce9805a81106172b2fec7837056825b7b0efe9d4fbd9","title":"Part 39. Get the IFC Building Information Model","path":"/ideCAD/part-39-get-the-ifc-building-information-model","children":[]},{"id":"ci_648707ddf821b6a5c02967df163de04b4a20178ec3dfe37de9fd391a35e89a05","title":"Part 40. Get the 2D / 3D Drawings","path":"/ideCAD/part-40-get-the-2d-3d-drawings","children":[]},{"id":"ci_a85a9e3b9b5c5217e60f3a5da281881ba1cc3294831dc17dfc4c5572174516a7","title":"Part 41. Create a New Structural Building Information Model","path":"/ideCAD/part-41-create-a-new-structural-building-informati","children":[]},{"id":"ci_3c8686377daae134cb50ad3fc4c04e0d676adcebecaf89cd6d619e97510f6ad6","title":"Part 42. Examine the Structural System","path":"/ideCAD/part-42-examine-the-structural-system","children":[]},{"id":"ci_2076c8f05a8fe59b434dc50a3785f72dc802a02364d6060794c21d755ba38422","title":"Part 43. Use the Wizard for Analysis Settings","path":"/ideCAD/part-43-use-the-wizard-for-analysis-settings","children":[]},{"id":"ci_76f69b9a47069eb71e426f53cf77f5dd55afbd53f7c8bc0707a9d754cc102b01","title":"Part 44. Optimize the Structural System","path":"/ideCAD/part-44-optimize-the-structural-system","children":[]},{"id":"ci_f3609dc45ba05f3f322312110507fcc47bee301196d80c9774bb202e36f4060f","title":"Part 45. Check Geometry and Failure","path":"/ideCAD/part-45-check-geometry-and-failure","children":[]},{"id":"ci_ff74e0be2f11b7d0c04050e4e41da6fd6ee33b5fd1b1356ff0a3e931cc1c6dab","title":"Part 46. Fix the Failures","path":"/ideCAD/part-46-fix-the-failures","children":[]},{"id":"ci_723138ff190449039dd9c7614115ff7aa19a2f9f2208dbdefcb4fbefc65462bb","title":"Part 47. Examine the Analysis Model","path":"/ideCAD/part-47-examine-the-analysis-model","children":[]},{"id":"ci_b4d49a1a3c9992165ce1647101a7e2a8d8e2ebd5f226b921d9ba3d20bacaacdf","title":"Part 48. Examine the Load Model","path":"/ideCAD/part-48-examine-the-load-model","children":[]},{"id":"ci_9df0a44ece0c89e2c942a0f8ec5f9112aad8b1ff42c815bc60c6ffcc000aa213","title":"Part 49. Analysis and Design","path":"/ideCAD/part-49-analysis-and-design","children":[]},{"id":"ci_983c76fa92662654165e533a8949a8dc963956f66d122c5835c18783053683c9","title":"Part 50. Review Analysis Results","path":"/ideCAD/part-50-review-analysis-results","children":[]},{"id":"ci_e8ebf43a70b031d456daec031630e3ce2d4f419d926b396974f63d177dc4fc14","title":"Part 51. Review Concrete Design","path":"/ideCAD/part-51-review-concrete-design","children":[]},{"id":"ci_1ac836b3039c44d780cb26911bd71494cdfce580c82765d3f053e345734b6258","title":"Part 52. Review Steel Design","path":"/ideCAD/part-52-review-steel-design","children":[]},{"id":"ci_26f300d1bcfeeabb41568f6b4adc9fc163f047456cafc980b47d7a896f1589e9","title":"Part 53. Modelling Steel Connections - 1","path":"/ideCAD/part-53-modelling-steel-connections-1","children":[]},{"id":"ci_ba5366a6a51a54dc9269ba77e34c0616fc7f2f443838d67d2c547abef44b227b","title":"Part 54. Modelling Steel Connections - 2","path":"/ideCAD/part-54-modelling-steel-connections-2","children":[]},{"id":"ci_159ed8ac40bf060b0b684338e121aa5db74059aecbaa2ed59ca6a5668648a2ab","title":"Part 55. Generate Select Reports","path":"/ideCAD/part-55-generate-select-reports","children":[]},{"id":"ci_02d99b939492de3e48891287eeed7d73838fc4c669f9a8fb009ffff8050a5584","title":"Part 56. Generate Concrete Design Reports","path":"/ideCAD/part-56-generate-concrete-design-reports","children":[]},{"id":"ci_a95f7605854fabf5e63df1bb54bf572da92ac7422d76a5882ceabdf45754c8ff","title":"Part 57. Generate Steel Design Reports","path":"/ideCAD/part-57-generate-steel-design-reports","children":[]},{"id":"ci_06123f5e6aee0ccd9853fe8614aa1773b35f4ac0472280ce4fe00d2f2c4d371e","title":"Part 58. Create Concrete Drawings","path":"/ideCAD/part-58-create-concrete-drawings","children":[]},{"id":"ci_4f68a23d9b3bb823b85c16ca6375dbe78a4de76ce105a68ce61e393c21b2782f","title":"Part 59. Create Steel Drawings","path":"/ideCAD/part-59-create-steel-drawings","children":[]}]},{"id":"ci_f69fadb6b54a0f87dd71d15dab6699d492af6301cc12cc6b25d54347e2017400","title":"Getting Started with ideCAD: Download, Install & Support Resources","path":"/ideCAD/getting-started-with-idecad-download-install-suppo","children":[]}]},{"id":"ci_70e4cd6a02784c81e8d1053eee36237f9e90b91c51b8cb7b963b4fabebbc9725","title":"Model the Design","path":"/ideCAD/model-the-design","children":[{"id":"ci_eec3516efc0761c243c32c683763f27ab758d1f2210c3b267dac4bd846cae5c5","title":"Model Views and Presentations","path":"/ideCAD/model-views-and-presentations","children":[{"id":"ci_eadf8017ba8e7f47a70be9509587919918b205af85a1611d60441ca34d4aac31","title":"Project Views","path":"/ideCAD/project-views","children":[{"id":"ci_da12e559cb8da7f608e5e99a6e53ec5a16690719d83ba06cd3284783d39b413e","title":"Story Windows","path":"/ideCAD/story-windows","children":[]},{"id":"ci_7f9f243ebe77d019f2ad1cf639d80739a565a22eaaf1b98c13840481622c59e5","title":"Architectural Plan View","path":"/ideCAD/architectural-plan-view","children":[]},{"id":"ci_80cc1174fe8b6d2b25a38ae0b15c1856660f28fc9e6088989294058e93b54497","title":"Structural Plan View","path":"/ideCAD/structural-plan-view","children":[]},{"id":"ci_b7ce2a1cceb213d4341c706ac109da16a8aeb86b6e4e3f3ed87ec96c982c0b9a","title":"Plan View","path":"/ideCAD/plan-view","children":[]},{"id":"ci_eae3a45bed9df5438fe6ceab16d01e7126f0a0e1856744cfeacb816ebf9d37d9","title":"Section View","path":"/ideCAD/section-view","children":[]},{"id":"ci_8b4c3b410feb21a06ad88304eb0b6e6766dd9fb5d962c2dc016732216f603b65","title":"Elevations View","path":"/ideCAD/elevations-view","children":[]},{"id":"ci_e92022bfbaf26c63462656e16ae3238dcb46e4dc686f2ae51117685820941efe","title":"Perspective and Axonometric Views","path":"/ideCAD/perspective-and-axonometric-views","children":[]},{"id":"ci_d1bfb9a7530c3f7aff7e1f8836db399f776e467d84dabe191105903c8f1ae228","title":"View Window Processes","path":"/ideCAD/view-window-processes","children":[]}]},{"id":"ci_116fed475480f2ddfbbad3daf8752300bacabce39cbe53695fa9fedb990f4a78","title":"Model Detail Selection","path":"/ideCAD/model-detail-selection","children":[]},{"id":"ci_d94a673929c4193d3decb2b21ddc97bffe8ed410f6a1125b83fd445cc5f49c61","title":"Real Time Animation: Fly Mode","path":"/ideCAD/real-time-animation-fly-mode","children":[]},{"id":"ci_3385bcb5831b55a38f8a0ebdaf39afbc1143c77aed5504c6ce0ef16947fa523f","title":"View Filters","path":"/ideCAD/view-filters","children":[]},{"id":"ci_9de9f38e1bcf1ebb08b272fd601451652e212d843082ef56195068cfc3d9b6ff","title":"Show Nodes in the 3D Windows","path":"/ideCAD/show-nodes-in-the-3d-windows","children":[]},{"id":"ci_646ebfcf395ac711a59a0f87ed946967d2950ac83f321ee09e88b39e1bf81dff","title":"Horizontal Plan Sections","path":"/ideCAD/horizontal-plan-sections","children":[]},{"id":"ci_8bad8965cfb392a7e3283ce7aa6588ca0c177b47bb2586f3c41c6ae96c102649","title":"Horizontal Workplane","path":"/ideCAD/horizontal-workplane","children":[]},{"id":"ci_06eabd2bc8f1010da5c01bf705440ae767b222456157a810f10a109fdf6782f4","title":"Vertical Workplane","path":"/ideCAD/vertical-workplane","children":[]},{"id":"ci_1765a1c8ffaf6f3bd727404d307010bc899b3a109feb0870eddc445dfb1a2d1f","title":"General Workplane","path":"/ideCAD/general-workplane","children":[]},{"id":"ci_6ad46dee37abd422136f7ba65ed0aadae9c762b73f51f099a4661cd77635482f","title":"Target Workplane","path":"/ideCAD/target-workplane","children":[]},{"id":"ci_bb6799654b84664a9ba35b6311fa4912512c2ced57ba8fd0fdc82166336cd8c8","title":"Vertical Frame Plane","path":"/ideCAD/vertical-frame-plane","children":[]},{"id":"ci_a51bdc6e842556fcdf74c55c790a3006a589077a73b629393c342c6d51812c9a","title":"Clip Plane","path":"/ideCAD/clip-plane","children":[]},{"id":"ci_a13c3a9b11c71018ed4c6f7db5e805866a100485a766802369baef87f03b76c7","title":"Analysis Model View","path":"/ideCAD/analysis-model-view","children":[]},{"id":"ci_6d913630dd2180147e945f0b41b10980ca135db8f465240fa599a1f9d808c690","title":"Structural Design View","path":"/ideCAD/structural-design-view","children":[]}]},{"id":"ci_996952c288abf63bb44fb04b5ae4b3092b906dee540f0f70ae926925a8afac74","title":"Introduction to Modeling","path":"/ideCAD/introduction-to-modeling","children":[{"id":"ci_aa151573d04bd8a62fdbabeb98d201cf3a97f853a4b95e04f08c1f4a1315d920","title":"Smart Objects and Sketching","path":"/ideCAD/smart-objects-and-sketching","children":[]},{"id":"ci_f7bf329024534f9e5a1521a83ac5fa498a7c95690ba220e6d90d2059d721a155","title":"Object Selection","path":"/ideCAD/object-selection","children":[{"id":"ci_0d498b0e9139535d2d30e8bca01cf272f5bc062ad13bcdb9de47723b95b0c387","title":"Mouse Selection Methods","path":"/ideCAD/mouse-selection-methods","children":[]},{"id":"ci_d79ca147136a10c96ba6232b365feeb4f765e7ce41d98199f9e144e98b78b6db","title":"Select All (Ctrl+A)","path":"/ideCAD/select-all-ctrl-a","children":[]},{"id":"ci_8239af5c105e085c956925656efb8f5ab9752412f1ff480be0a6a4c499dcdbe2","title":"Deselect All (Ctrl+D)","path":"/ideCAD/deselect-all-ctrl-d","children":[]},{"id":"ci_66a0bb810d5ce485fb21476f3fba38a6019e3d596177dd8370ce51123cb631c5","title":"Select Similar","path":"/ideCAD/select-similar","children":[]},{"id":"ci_7c84508628de4187a0860f8204d16e0f9f6534eb3f7aa18fb4dbff82e4d7acf8","title":"Get Selection/Set Selection","path":"/ideCAD/get-selection-set-selection","children":[]},{"id":"ci_20cc5e9333b9a962865e38436b5b0404ca08a740ce30dbfdaa6ee1db96e618a0","title":"Remembering the Last Selection","path":"/ideCAD/remembering-the-last-selection","children":[]},{"id":"ci_cb3013e4eb47244fd4ae5377143522dd93b6e57f4bd6ca21d84863fa8299f49b","title":"Create New Selection Group","path":"/ideCAD/create-new-selection-group","children":[]},{"id":"ci_3c838ee31b5f64cd8a08abbd02f1404f20c731e1ef73d0e80684d8e0de73ca38","title":"Add to Selection Group","path":"/ideCAD/add-to-selection-group","children":[]},{"id":"ci_a1048c0873adc9ac155712ef5c7bb38a45f8393ea4405ea7f3c748e9d2bbe26b","title":"Remove From Selection Group","path":"/ideCAD/remove-from-selection-group","children":[]},{"id":"ci_a05a8e4eb04a357eb2151fb9cebebf1ee5eb1e53d7767ec7067aa095af382b49","title":"Select Group of Objects","path":"/ideCAD/select-group-of-objects","children":[]},{"id":"ci_78d436afb95a20340f2f64e39020cf40903109dd5e46e066c182adcc8191f5a3","title":"Selection Group List","path":"/ideCAD/selection-group-list","children":[]},{"id":"ci_5016cdd259a31590c664556483d071e918ea8bd5c4062dd419d2607e595ed15b","title":"Invert Selection","path":"/ideCAD/invert-selection","children":[]},{"id":"ci_b337071fde81bd4a3637ff9e9ec795c127093f6501859aa1274762a0bae66e13","title":"Select Entity in All Stories (Ctrl+B)","path":"/ideCAD/select-entity-in-all-stories-ctrl-b","children":[]},{"id":"ci_6ad3dd829516baeb9bcd698176bf872fa12a4db509a983078d41f6a19bc0edc8","title":"Object Selection Settings","path":"/ideCAD/object-selection-settings","children":[]}]},{"id":"ci_ee8b1e67aec3fad618324e5b76dd729884b3940b19e9006e73583e3e2cd9470d","title":"Zoom and View Pan","path":"/ideCAD/zoom-and-view-pan","children":[{"id":"ci_d4a936b9e54e0200fdf10c61470dfbae505fb1c6ae173056480b1afa3f6388d3","title":"Zoom Operation","path":"/ideCAD/zoom-operation","children":[]},{"id":"ci_08cf23171fee514e5d7778f6ecb3b560cf358d174f6de72b02c46a73ff95660f","title":"Zoom Command","path":"/ideCAD/zoom-command","children":[]},{"id":"ci_6308b9936852930067462e4e747f5b58cb50e7ea1261adb6907a7795c0656012","title":"Zoom Window Command","path":"/ideCAD/zoom-window-command","children":[]},{"id":"ci_e77f811720d9f10a1b4cff2b7b915aab8c5720200368ff496fd0817beb00d419","title":"Zoom Extents Command","path":"/ideCAD/zoom-extents-command","children":[]},{"id":"ci_d1b1efb605e9f4037918a81832ad96863a6eccbe41dead47661d41b99418f737","title":"Zoom Selection Command","path":"/ideCAD/zoom-selection-command","children":[]},{"id":"ci_8436f75b9b857433f6b5ec5c8a64d6ea4852b40f2b53695ced45a79488769a03","title":"Shift View","path":"/ideCAD/shift-view","children":[]},{"id":"ci_0be707edbdbdd686f31abfb0bcd3084b663fe2433e69e416acaab3fcc3eea08e","title":"Zoom Operations in 3D Visualization","path":"/ideCAD/zoom-operations-in-3d-visualization","children":[]}]},{"id":"ci_1d96f7d3e06772ad8152966d7a6c6e3312c14d42804a9ddad52363480b6dcc3e","title":"Stories and Creating a Story","path":"/ideCAD/stories-and-creating-a-story","children":[]},{"id":"ci_6784f1f15b86cb07f78d44edf5072996075a55f097f1c501ed2acd1273473d36","title":"Positioning","path":"/ideCAD/positioning","children":[{"id":"ci_ccc1af4d2eaf331c81d21f5f354d33de2021060c937ef5103414f28e3ede239b","title":"Coordinate Box and Dynamic Information Entry","path":"/ideCAD/coordinate-box-and-dynamic-information-entry","children":[]},{"id":"ci_6d756e55a71b9d66b4d66822fa6abd973b4093239bd4c798d410d42f1ffc4c2f","title":"Defining CS Origin","path":"/ideCAD/defining-cs-origin","children":[]},{"id":"ci_e5fdce6ec3e766b8f344c7005f52bb4a34bff4b8365b8412e8d7f14e544449c1","title":"Setting a Local CS","path":"/ideCAD/setting-a-local-cs","children":[]},{"id":"ci_45fe0c4a77ea0f9a9aac029175446ecbdf05bc748476e5319b8f8f0fc0a8d706","title":"Ortho (Shift)","path":"/ideCAD/ortho-shift","children":[]},{"id":"ci_47b646ed0c6fba2fa5a22010c2fa48cdafbbfe82c513f4a0e35bd0bd1cd1d4ff","title":"Perpendicular Reference","path":"/ideCAD/perpendicular-reference","children":[]},{"id":"ci_61ba32c8662204fde06a3481c5fc3bdf0afb6a78f825f30800ce7ec869acdbe1","title":"Parallel Reference","path":"/ideCAD/parallel-reference","children":[]},{"id":"ci_eb299076ac63217e3d2310409a5a1020873fcc12c99ede9b41b37b0ee8a73b19","title":"Tangent","path":"/ideCAD/tangent","children":[]},{"id":"ci_9a9c2520ec582edd76a0639b2ddfd37a565b90c3cd0e756da773f3a22c9cff61","title":"Object Snap Methods","path":"/ideCAD/object-snap-methods","children":[{"id":"ci_bf4c78bd00d9d01b06c94bdf8eef4e1f16780630f51f8a11b33f5ee27f83008a","title":"Advanced Snap","path":"/ideCAD/advanced-snap","children":[]},{"id":"ci_ada7816a842b4559dc20aaa03093972c8aaed73fa768d19208a796d8afb040bc","title":"Snap to Grid","path":"/ideCAD/snap-to-grid","children":[]},{"id":"ci_7ee0dd260f54957eeb00b673c433689dceb8a9cfb693fbef66851e2768464915","title":"Snap to Nodes","path":"/ideCAD/snap-to-nodes","children":[]},{"id":"ci_88f7e78297b67d137837f29b63cc04e285714350cc3a60562e797b114c31d049","title":"Nearest Point","path":"/ideCAD/nearest-point","children":[]},{"id":"ci_5af5576faedfa2fde2bed6af58b8bffca4ac6fe8d4485725e06cddde39f44b6e","title":"Midpoint","path":"/ideCAD/midpoint","children":[]},{"id":"ci_8da4d3e29dcde73037a3c2be8ca37887db182b8132bb52f97ab12876a75d6e02","title":"Snap Points on Line","path":"/ideCAD/snap-points-on-line","children":[]}]},{"id":"ci_858664942d19862061bfa351b7a14c2c388bbdd1bbd9899d834dacfd8df7014c","title":"Object Search and Finding","path":"/ideCAD/object-search-and-finding","children":[]},{"id":"ci_891ccf2315bb76c19517cc113a969930fe89fa9ce90b7609dec8eaba03718c17","title":"Find in Perspective","path":"/ideCAD/find-in-perspective","children":[]},{"id":"ci_9e3a3438f4a1801e5a9df4045a2120da5760f66a3001f282f8cc2ed7360667ee","title":"Find in Plan","path":"/ideCAD/find-in-plan","children":[]},{"id":"ci_3a614e1c7203eb119e7cc852fa384bb7def075e6f8b33a0276bc6948268008fb","title":"Area and Perimeter","path":"/ideCAD/area-and-perimeter","children":[]},{"id":"ci_5db7eb787d67c772d42ea5923e1e4f0881b4ffd927b7283d19edc03332f17c2a","title":"Distance","path":"/ideCAD/distance","children":[]},{"id":"ci_9cb9068ada4d9b32e4e15291fa2996ee3410a90f29a1a9c8199bbfef81609d72","title":"Angle","path":"/ideCAD/angle","children":[]}]},{"id":"ci_273259e941d63db6ad5cf6ade28657d72b7f06cf2f28e44e756f4e17ba2d3eb7","title":"Grids","path":"/ideCAD/grids","children":[{"id":"ci_de0a9ceb4cfb08c29da32b171369c9f327917c87892c619dae1acf9a754e3b62","title":"Axis Settings","path":"/ideCAD/axis-settings","children":[]},{"id":"ci_284147a663539849ec43d03b70ff72a49844b42ec5effab0306a8cbf07805b68","title":"Drawing a Axis","path":"/ideCAD/drawing-a-axis","children":[]},{"id":"ci_0385c031db85c30db12f5a8e6b4ec4f9d87ffceef61a573d6f0dd477b2f5bcc9","title":"Change Axis Draw Type","path":"/ideCAD/change-axis-draw-type","children":[]},{"id":"ci_204c712d7f67cd892926cc1299acd78d814c2ad8f510a1b25532f669de020ebb","title":"Drawing a Arc Axis","path":"/ideCAD/drawing-a-arc-axis","children":[]},{"id":"ci_91e923cca70573fad55788c221fcba66d5a454b933b38eb2c097d3d1310dc6a2","title":"Drawing a Arc Axis Through 3 Points","path":"/ideCAD/drawing-a-arc-axis-through-3-points","children":[]},{"id":"ci_33c2137cdc5ee69bb830a10aa13f500e8eabb5312d0ebae8a907809728029dcb","title":"Axis Offset","path":"/ideCAD/axis-offset","children":[]},{"id":"ci_5bf1c3b40baf522a53248daaa77cd584b080fbb68a593c2f0a81630ed321709e","title":"Axis Border","path":"/ideCAD/axis-border","children":[]},{"id":"ci_5ea8403d4dd860842001d7ddaa0788c646cf98d69fe3f00e80c5c63cbc13541c","title":"Extend to Axis Border","path":"/ideCAD/extend-to-axis-border","children":[]},{"id":"ci_42c005734bec4d055c7d1e05c6d65b77ab24339c924cb100a95a78bd995aaada","title":"Draw Axis Line Perpendicular Outsie Contour","path":"/ideCAD/draw-axis-line-perpendicular-outsie-contour","children":[]},{"id":"ci_9b6d1ded6699eb218458830c726b08d6e572b56ebc8b970000c65f1908b31603","title":"Axis Distance to Origin","path":"/ideCAD/axis-distance-to-origin","children":[]},{"id":"ci_e483135be257bc014c9e3fc8d9b36c822275ab3ef25d13658cfab374fad09be4","title":"Move Axis Label","path":"/ideCAD/move-axis-label","children":[]}]},{"id":"ci_8a3ee6f9039bac602869b93a65657ae0f47b4d3e383dd59a49da963b0e2e2be0","title":"Layer Management","path":"/ideCAD/layer-management","children":[{"id":"ci_e02ae98c1f17b5e437f703138bce545aac2d2d541c0b1e5097bb4a68abff6705","title":"Adding a New Layer","path":"/ideCAD/adding-a-new-layer","children":[]},{"id":"ci_24468d1aaa5f3d821d45e81372118c7a23417e62683b75d4a5e71754e67df684","title":"Layer Show/Hide","path":"/ideCAD/layer-show-hide","children":[]},{"id":"ci_e6f058aafa90aa54a430c432de2487d43368020cfabbd67ed558d11af25fec97","title":"Layer Lock","path":"/ideCAD/layer-lock","children":[]},{"id":"ci_2cd27dcff101277dc8ca8b6b9f2f0fe7bb4a688fbd5f72b99abaf93d4fad8524","title":"Removing Unused Layers","path":"/ideCAD/removing-unused-layers","children":[]},{"id":"ci_49614c63e8f34231bb3ad792e60681aabf9c701a62a850a5468c22c96b784f76","title":"Change Entity Layer","path":"/ideCAD/change-entity-layer","children":[]},{"id":"ci_860718b99b86018b9a3a2ae0c0dc7380e58746f9f5b60246b0c996c22a7a8cde","title":"Creating on a Different Layer","path":"/ideCAD/creating-on-a-different-layer","children":[]},{"id":"ci_6f0faf3b52b9608a1e1089a0ba9e52b09a4477b012157f94f9177c1fc1b8e4a1","title":"Layer Settings","path":"/ideCAD/layer-settings","children":[]},{"id":"ci_5ae52de87297735d45814a02ef6e1e24dea2625e4139d26b2e67f752c17f1247","title":"Object Layer Drawing Details","path":"/ideCAD/object-layer-drawing-details","children":[]},{"id":"ci_240f9d8be2df8919051e89f0f995322c3cf71b887821cc411557c450df4b3f1d","title":"Make Compatible with Architecture/Structural","path":"/ideCAD/make-compatible-with-architecture-structural","children":[]},{"id":"ci_4eedb596c6bce5ab774d4dc48ea8cbfe6b8202611384d86d2e8c89fd62ce47a2","title":"Drafting Mode","path":"/ideCAD/drafting-mode","children":[]},{"id":"ci_52526c3ad94a2cdf3f5cd76d8eacb0e8918861c5c95f641b01b2a2172a657625","title":"Transparent Story","path":"/ideCAD/transparent-story","children":[]}]},{"id":"ci_f96dc8153a841d0f12470d9ac3b16ba9e424b0621d6a9b81e061c93021043fea","title":"Object Duplication Methods","path":"/ideCAD/object-duplication-methods","children":[{"id":"ci_ae38225c182248a5022df0f87d5192547f3a9ca22176698e781454dea32e3988","title":"Clone","path":"/ideCAD/clone","children":[]},{"id":"ci_2747b63e5b78832fcd9a255dc6d25a017dceaface04da7ff8dfdd2441b1fde3d","title":"Array","path":"/ideCAD/array","children":[]},{"id":"ci_c33c8ddd4464b87300455e1100c2b748245e374ed891894b8bc1d382cde0f448","title":"Copy and Paste","path":"/ideCAD/copy-and-paste","children":[]},{"id":"ci_de9ee4fc941d22717209f9fc1f69454980da2c814c22e07a61b45bb0ca63e726","title":"Advanced Array","path":"/ideCAD/advanced-array","children":[]},{"id":"ci_56302acbd1281db4ec6db746c891ff3ab492478728a1941901eb2b5478e00364","title":"Polar Array","path":"/ideCAD/polar-array","children":[]}]},{"id":"ci_5808f010feb85d2cd72c3599fd45fa9c15eb7b87b0653febf7ef1f37a1ec533d","title":"File Operations","path":"/ideCAD/file-operations","children":[{"id":"ci_28bbbb6825333dd822a4cd9e04b6ad716640f1b3b67f8d9551a35a2f3c4389aa","title":"Use of Composite Material","path":"/ideCAD/use-of-composite-material","children":[{"id":"ci_d82fc0ebd1dcf94fcafc274db05ab6bb9d8b67397767a374ce0db1c1be78876e","title":"Creating Composite Material","path":"/ideCAD/creating-composite-material","children":[]},{"id":"ci_4a31fd59c53e0c296dde893b9b641abf3dafb732ecc4c1fe5d15a720dc577fe4","title":"Saving/Loading Composite Material","path":"/ideCAD/saving-loading-composite-material","children":[]},{"id":"ci_891ef3e7e53bef56f057f0373c5cf59cb9d99089ae395d79b7aecedfeed6a154","title":"Assigning Composite Material to Objects","path":"/ideCAD/assigning-composite-material-to-objects","children":[]}]},{"id":"ci_2e6644165e7f0180f4f928823b4cdd1ebd62e845b806d2cbc5f1430079078bfe","title":"Save Methods","path":"/ideCAD/save-methods","children":[{"id":"ci_9d592e7bc3b02576583919bf166de2c79902696ea8ca2118cac0d275c422ec3d","title":"Save","path":"/ideCAD/save","children":[]},{"id":"ci_c18b957cdd2cf684b4d988b6ead15e0ef1436308671734a259c6390a655ab0a1","title":"Save As","path":"/ideCAD/save-as","children":[]},{"id":"ci_ee0d895d96f7dee1362a06bd7c0ec699ff1e525b0e5832b06723ee8131fd0f0d","title":"Save Compact","path":"/ideCAD/save-compact","children":[]},{"id":"ci_a0c303a6ce937bbee9a3f489fd897236d1b0fd78d58eacaa190fee241c898a52","title":"Automatic Save","path":"/ideCAD/automatic-save","children":[]},{"id":"ci_ffa52bad2173a8c8a4ba1f035b5c352c15f97fb1516ba18d9889c2ef6c6d7ebf","title":"Save Old Version","path":"/ideCAD/save-old-version","children":[]},{"id":"ci_0e968c5cb200cc47edd5c18195fb8276b6aa87e230a2a739ca348d3d0d11b6e3","title":"Copy To File/Paste From File","path":"/ideCAD/copy-to-file-paste-from-file","children":[]}]},{"id":"ci_f2221b65258f81d1ca6a04d6dc57a61fd91bb38ef13c629bd65bf984d24059ea","title":"Data Exchange with Other Programs","path":"/ideCAD/data-exchange-with-other-programs","children":[{"id":"ci_a6f5f73239dbd5a682a9bc1cf0adfb761f1b93b719f868b9fa87ba515acc65a6","title":"DWG/DXF - 2D Import","path":"/ideCAD/dwg-dxf-2d-import","children":[]},{"id":"ci_f46afeb284a412d626a9709426b520bb1c03d27b347fe39dd182c359e88ce737","title":"DWG/DXF as Structure Import","path":"/ideCAD/dwg-dxf-as-structure-import","children":[]},{"id":"ci_cdabcd407346c2a6add0fe802a39437280abc701021347902e34eff5f2fa6146","title":"Import IFC","path":"/ideCAD/import-ifc","children":[]},{"id":"ci_396b932dea8344c36d2b9bf58bb9f7e7bc69cbdfb1796c4fc6de272ebb25c597","title":"3D Block Import","path":"/ideCAD/3d-block-import","children":[]},{"id":"ci_22e837e2515ac89db78a7a9d01ce1dada6216546ccb573fc684278be97633d37","title":"Wavefront.OBJ Import","path":"/ideCAD/wavefront-obj-import","children":[]},{"id":"ci_f1104ab8d3ac295e23dadddb5f86152961cc3ce80102047eea6d992c4a314aae","title":"3DS Import","path":"/ideCAD/3ds-import","children":[]},{"id":"ci_d0fd317a1aaf06972af1ff254e3920a6fc50b99540731778e2938399c17967be","title":"PDF Export","path":"/ideCAD/pdf-export","children":[]},{"id":"ci_9413ea37cc8f78dcf16eb3ac4a79cb774d4d5b9040593a27400704da94fdab65","title":"DWG/DXF/DWF Export","path":"/ideCAD/dwg-dxf-dwf-export","children":[]},{"id":"ci_5be86bfc5e7bbaef693645f366eb40cdfb5b07a768b090a59207d5b35ad8f87d","title":"DWG/DXF/DWF Single Export","path":"/ideCAD/dwg-dxf-dwf-single-export","children":[]},{"id":"ci_a23d147ba03b22f1ed2b2612f57f753ce953414049b7523b39dd18910a4ae299","title":"IFC Export","path":"/ideCAD/ifc-export","children":[]},{"id":"ci_5696bddc8a9b80adda42f35f08ea9f031c027acaf4d3de7c36e829e8972dbc76","title":"3D Block Export","path":"/ideCAD/3d-block-export","children":[]},{"id":"ci_3fe8175f0da433a7a0bbde4e9b3391b8a8f0e41a4346d1ef0e6744ab9923be96","title":"Tekla.dmp Export","path":"/ideCAD/tekla-dmp-export","children":[]},{"id":"ci_a147498d2c48cf264b2576ab82d3c8b4948edcb7355a9a9d4b4e4bb8212813b3","title":"SAP 2000 Export","path":"/ideCAD/sap-2000-export","children":[]},{"id":"ci_3c7e18cafa1f95970990f927612219164e6b0d91cf6e0a3442f167522b3db327","title":"CSICOL Export","path":"/ideCAD/csicol-export","children":[]},{"id":"ci_451d49ff477d45f07139b56bfb2a8ca1f60cf99932f6f22d60db6510ccfe5958","title":"3D Printer (.OBJ) Export","path":"/ideCAD/3d-printer-obj-export","children":[]},{"id":"ci_bcd6019956d682f787d0dce839c053775b658f81c3faf6cc78eee71e7d637f8e","title":"3DS Export","path":"/ideCAD/3ds-export","children":[]},{"id":"ci_07110328ae4c279a78c90ea2a305439e61832e50402900a29fea6bcad263d433","title":"Plan Screenshot","path":"/ideCAD/plan-screenshot","children":[]},{"id":"ci_05cd5200a0832bb480746f904454b861e9b46f07d130491a19a34952d32cc1f7","title":"Export to Excel","path":"/ideCAD/export-to-excel","children":[]},{"id":"ci_2032e092bb7b2449b1eb401019dde55391fb0a0c0a7d610489785f6309872a95","title":"Viewing ideCAD Model from Mobile Phone and Tablet","path":"/ideCAD/viewing-idecad-model-from-mobile-phone-and-tablet","children":[]}]},{"id":"ci_8571f6d128ec986c7f581b689f7923fa92e58e0bb871e1a61abfd7f52f7f9e98","title":"File Menu Operations","path":"/ideCAD/loading-methods","children":[{"id":"ci_4782f6757df525d17470ba7235858163d83805c17b34145b86c3a8e4d7061c63","title":"New Project","path":"/ideCAD/new-project","children":[]},{"id":"ci_a1507d4c8d0e175671a53c3cbfcf4a5629bdbc695f30569d672bdbb9f9a67de9","title":"New Project Wizard","path":"/ideCAD/new-project-wizard","children":[]},{"id":"ci_deac9957a1b5e004f5bb674fa41bc85530d8855c95ca150c254214004bcd74c1","title":"Open Project","path":"/ideCAD/open-project","children":[]},{"id":"ci_b07e3951e6dea93a56b595deda6f01b343ccf07f0e674d0176fe0883f888eb41","title":"Finding the Version of the Project Saved","path":"/ideCAD/finding-the-version-of-the-project-saved","children":[]},{"id":"ci_8743ccba35c44c0d56533f66c18fd2b7b5e807134c51173a270bec57ef056903","title":"Loading Project Backups (.bak)","path":"/ideCAD/loading-project-backups-bak","children":[]},{"id":"ci_509fc71c729d0baac973c3e55ff25e5eccf40c8640ac13377818e5900407f51c","title":"Loading Saved Reports","path":"/ideCAD/loading-saved-reports","children":[]}]},{"id":"ci_3ad7dc1b809ecc75be835a7ca309882a9db1784c2e043df0b734f7b1c6b567f9","title":"Printing and Plotting","path":"/ideCAD/printing-and-plotting","children":[{"id":"ci_3b86f2255abb700a6240f6ff941da329a6ec83de67a65a932368a3abfba53909","title":"Pen Thicknesses and Color Settings","path":"/ideCAD/pen-thicknesses-and-color-settings","children":[]},{"id":"ci_a69369f9b95697c9df660e4c3235b729153c229020868977c69fb741f5d2c767","title":"Plot to the Project","path":"/ideCAD/plot-to-the-project","children":[]},{"id":"ci_1b6497a208c96c818c3d99778adabf0947876fa423fa9227fe6d71ea4a83d571","title":"ideCAD Wrep","path":"/ideCAD/idecad-wrep","children":[]},{"id":"ci_ae6e6c18a5c27e6e0954cd2d142a1b08ee281fe1025585005491b60b80d4b874","title":"Print to Reports","path":"/ideCAD/print-to-reports","children":[]}]}]}]},{"id":"ci_6806c71b30d826aea36c7a1a8ff0a0902ce7cd30c1c0249d80eb5261aaefa66d","title":"Auxiliary Objects For Design","path":"/ideCAD/auxiliary-objects-for-design","children":[{"id":"ci_8f8b17d5edcb7915218f7a5a948416c2b8491369ff90fa3b54fd272208c56c2d","title":"Hatch","path":"/ideCAD/hatch","children":[{"id":"ci_d8a7d4d2a5d5ce236dfa1bbb82f50958c9cecccd1c0ae61d1df6e19a3476358c","title":"Creating a Parametric Hatch","path":"/ideCAD/creating-a-parametric-hatch","children":[]},{"id":"ci_2672be8655d270471a28aa137ce95940b82c109253e711bf4225cc45b8bed770","title":"Creating a User Defined Hatch","path":"/ideCAD/creating-a-user-defined-hatch","children":[]},{"id":"ci_c36fc671c0ae4789d503caee0927e40e757849cf15874edb912d3122ac023a3e","title":"Creating a Bitmap Hatch","path":"/ideCAD/creating-a-bitmap-hatch","children":[]},{"id":"ci_ff185624336ddeb13e149817ebd3ad96fdfc9a459c0ffa39689c68aff0230fea","title":"Automatic Hatch","path":"/ideCAD/automatic-hatch","children":[]},{"id":"ci_ac904b5e8d29d28a61a157c9d8d0e6ef655805d90c120cc32dd069eddad3b37e","title":"Find Hatch Holes","path":"/ideCAD/find-hatch-holes","children":[]},{"id":"ci_1f82c9ef3a19e85b2f1c325c2803b7eadc25d7a6780e8f69dfaf063cae180173","title":"Hatch Hole Settings","path":"/ideCAD/hatch-hole-settings","children":[]},{"id":"ci_93b8e89f468780c9f71e128af5214e9fb4682b05c9487d9422593ac985f7f96b","title":"Creating a Hatch Hole","path":"/ideCAD/creating-a-hatch-hole","children":[]},{"id":"ci_e7572b4584ae525e2fd0ec3aa2177a6254366ac98ea21215c7d16ceb45f80d33","title":"Creating a New User Defined Hatch","path":"/ideCAD/creating-a-new-user-defined-hatch","children":[]},{"id":"ci_a3fe2bed9683e4fa6bb05ae1009a2682797fff601181e85914d88bfa5ec8d60b","title":"Hatch Offset Distance","path":"/ideCAD/hatch-offset-distance","children":[]},{"id":"ci_567149143cc9529cffec315c2ee505ea249f3c1f35a8a81d73edda42b52de2d7","title":"Add Lines to Edges","path":"/ideCAD/add-lines-to-edges","children":[]},{"id":"ci_8cfcc98ee1c65e1b112524e135f82bc9bcbdb99f7ac5f3932a35d8d9a664ff1d","title":"Setting Hatch Reference Point","path":"/ideCAD/setting-hatch-reference-point","children":[]},{"id":"ci_55d19a6cafc86f017228c350d3281fa666d35244709964e5c4041670e790120c","title":"Add/Remove Points to Hatch","path":"/ideCAD/add-remove-points-to-hatch","children":[]}]},{"id":"ci_5b66dc1a3ef8e3f2a4716a801b41ee728d03324f7fb356ed10363e50532e9348","title":"Annonation","path":"/ideCAD/annonation","children":[{"id":"ci_5ac851ca20b6f82051ce5cd99113d86b13bfc5ce9f54d6e44493997bd8a8e368","title":"Dimension","path":"/ideCAD/dimension","children":[{"id":"ci_937f18b58afc02a416a468942f23b283d90f6c2db5f5f960ba6cc148c0f8cb27","title":"Creating an Outer Dimension","path":"/ideCAD/creating-an-outer-dimension","children":[]},{"id":"ci_d261be173e9b8fd62dcfe741a90b4f045cf13a0938cd9b9c17647834f2df8570","title":"Creating an Inner Dimension","path":"/ideCAD/creating-an-inner-dimension","children":[]},{"id":"ci_73aea5f020c85e6a750aa0ee18e017c06d5ded5f1feec106f4fb3aec8af39181","title":"Creating a Free Dimension","path":"/ideCAD/creating-a-free-dimension","children":[]},{"id":"ci_bcd4a75eaebecf47192a6bb3bd8b523973abdad86b363ca9f8981e492ed46471","title":"Creating an Intersection Dimension","path":"/ideCAD/creating-a-intersection-dimension","children":[]},{"id":"ci_10f25f438af92c2d93543876e6b71ba239d3973105ad846cad9098707a40361e","title":"Creating a Level Dimension","path":"/ideCAD/creating-a-level-dimension","children":[]},{"id":"ci_be622ba7165ee4f67b66b226166824a929d14f9bb97ebe14f9abb1cac06ddbc8","title":"Creating a Section Elevation","path":"/ideCAD/creating-a-section-elevation","children":[]},{"id":"ci_ca7a5c12d8c41a2f792e021469247598bdac0a36f0ad2bcb42061ae64bb0226d","title":"Creating an Angle Dimension","path":"/ideCAD/creating-a-angle-dimension","children":[]},{"id":"ci_dac5c6aa9449dfc633e0dd5259156309c75c1aa94219ebd3ac2c6e1cacba3359","title":"Creating a Radius Dimension","path":"/ideCAD/creating-a-radius-dimension","children":[]},{"id":"ci_e861ef3c1b30bd2c22eb33885bcc8e209248f87a625dfebdaf12e6e1b12d38e0","title":"Section Dimension Group","path":"/ideCAD/section-dimension-group","children":[]},{"id":"ci_326820189fc72fe93399f0340d234a3fecf9c83e8316224581352163557e7075","title":"Section Dimension","path":"/ideCAD/section-dimension","children":[]},{"id":"ci_9930db2801fa9c052ede161c148c3f0517be41e3eb67dc53324592107ac4f0e7","title":"Creating a Label","path":"/ideCAD/creating-a-label","children":[]},{"id":"ci_e573c3983fa6c7db8ad16a3ec16309d86dc52b287adf19e05eca7dc7c04ed6a1","title":"Add/Remove Dimension Parent","path":"/ideCAD/add-remove-dimension-parent","children":[]},{"id":"ci_acda41cdaf9359300c35810862568998e6e64627d3466c27f2af2c23bb5bbcfa","title":"Move Dimension Text","path":"/ideCAD/move-dimension-text","children":[]},{"id":"ci_12dc4f0eb0b5e0f8f270c9b33b17ee86862d4971005ca6153d31a3c5e0ad4e7d","title":"Show/Hide Dimension Text","path":"/ideCAD/show-hide-dimension-text","children":[]},{"id":"ci_396593794ab94886d9097d98f1953f293f50b7d7a41429126b3d032de7262602","title":"Reset Dimension Texts","path":"/ideCAD/reset-dimension-texts","children":[]},{"id":"ci_caffe3d8b7a02d79c0230cc241c4cb17118a85e4df30164359d286e8a18f0b01","title":"Changing the Value Scale","path":"/ideCAD/changing-the-value-scale","children":[]},{"id":"ci_50ef57c78e8d61916abd3771c7a3a27c9b51a2eaecbf4f96e2c0c1ebff66e274","title":"Edit Label Text","path":"/ideCAD/edit-label-text","children":[]}]}]},{"id":"ci_ef6102585f84ffa9b531fe205d53c0220ba3da77febb01bea647fd53a799c077","title":"Text","path":"/ideCAD/text","children":[{"id":"ci_f18081a8f5032b1f28ad338b3308a8548747c4d015035ca1cff4258b285aaa65","title":"Text Settings","path":"/ideCAD/text-settings","children":[]},{"id":"ci_4268b1054e0c38a25c849d9396ab0b86b71345e5b7cbf42a8be06abeb5a6350a","title":"Creating a Text","path":"/ideCAD/creating-a-text","children":[]},{"id":"ci_0c804745baab468aefdf35127bceafb2cf13e903b9202f0e06ab719f35d2fae7","title":"Creating Formatted Text","path":"/ideCAD/creating-formatted-text","children":[]},{"id":"ci_0a8244e2aa17cf9913a35e0981001c64ad1c7838af6d7b210432f2f1cf623208","title":"Importing Text","path":"/ideCAD/importing-text","children":[]},{"id":"ci_4a9670ac14d1144622d53134241e9a3afdc8daace075ab38cdc1350772ea184f","title":"Edit Text","path":"/ideCAD/edit-text","children":[]},{"id":"ci_e3cb708a2d166edbfd5cf58de0d969394080db2c5efc595ec854c66f338c7638","title":"Texts in Dxf, Dwg Files","path":"/ideCAD/texts-in-dxf-dwg-files","children":[]}]},{"id":"ci_28841edd1f0fa52de69a8056b6ab58694a116c2d626f21a1c13991df6879aff1","title":"Line","path":"/ideCAD/line","children":[{"id":"ci_c122bd5913226357c1a3de63c82b72ebebedbe2fe8d3c67685283c2a72c7f5c7","title":"Line Settings","path":"/ideCAD/line-settings","children":[]},{"id":"ci_a2c8e9da2eddc985cbb63f8c5bd8fbce5c601ee60b1029c6fc64b820390d7010","title":"Creating Multiple Lines","path":"/ideCAD/creating-multiple-lines","children":[]},{"id":"ci_c517a3820f03b6db4055fb1171ec7a8f13bb0fc7fe5159bfc7a76464ee69eb4c","title":"Creating a Rectangle Line","path":"/ideCAD/creating-a-regtangle-line","children":[]},{"id":"ci_c01a66b84d65146e45c179f37e970bc9b5842fbbe845237db5f88575dc7b1896","title":"Creating a Path","path":"/ideCAD/creating-a-path","children":[]}]},{"id":"ci_2b166d72d96b1237bdef71be8684e019d1f3eaba26005b1c87c4222a5035c510","title":"Curve","path":"/ideCAD/curve","children":[{"id":"ci_c4164193675eec7ad09f9d9f07d16f3d8fffa095664e1678d31d20532e771568","title":"Curve Settings","path":"/ideCAD/curve-settings","children":[]},{"id":"ci_f848210aa21bf64d5057f06ccb8531620a1c886db036808a6fe64996126352e5","title":"Creating a Bezier","path":"/ideCAD/creating-a-bezier","children":[]},{"id":"ci_96cf79216d6108e40e01b0278deb3baa32aa8b8dbbd68e8dccb8402be0c5be7a","title":"Creating a Closed Bezier","path":"/ideCAD/creating-a-closed-bezier","children":[]},{"id":"ci_606570a84081be2159dcb040efe3846b1bf50aff6588a740aebd9050f0c59e92","title":"Creating a NURBS","path":"/ideCAD/creating-a-nurbs","children":[]},{"id":"ci_41e4eae822ebe70ce0fe11e2e74416534c0f95312432acc8243ff3ed80bdaa3b","title":"Creating a Closed NURBS","path":"/ideCAD/creating-a-closed-nurbs","children":[]}]},{"id":"ci_4cff6ab83bc84b5a3632efa304862d383bc7631dc5c2d9eaa044ef5648f4cfc5","title":"Freehand","path":"/ideCAD/freehand","children":[{"id":"ci_980e4bd7296ea2007a77b49818d6cc4c93a7d61f962e62a7bd12bfa9a9cff279","title":"Freehand Settings","path":"/ideCAD/freehand-settings","children":[]},{"id":"ci_3b2030a4cc85df3317ecbb867f8d9b40b1b1136b49fdc6e0d73fc8616b562ad8","title":"Creating a Freehand","path":"/ideCAD/creating-a-freehand","children":[]}]},{"id":"ci_fd57cc1dd04511e9689d55e038e27ff887a5274c920a281e87bfe7b3b2490810","title":"Circle","path":"/ideCAD/circle","children":[{"id":"ci_6f9b5d26b2da187623753f83d1e84b94d41714b9d55f08e06e4961f43c703d76","title":"Circle Settings","path":"/ideCAD/circle-settings","children":[]},{"id":"ci_d405994746e376a6e7dbf7eb350417572a5b8e354e46b7172d7c7c439dedf201","title":"Creating a Circle","path":"/ideCAD/creating-a-circle","children":[]}]},{"id":"ci_2375439f753b717e6100c7038bd549048386b6d57083530933c2de5d92e8766c","title":"Arc","path":"/ideCAD/arc","children":[{"id":"ci_fd014591bc16114abaa9b8d81e92fdc11e013475c53e80226446dac462ccbf59","title":"Arc Settings","path":"/ideCAD/arc-settings","children":[]},{"id":"ci_08cb3f5afc4344d76d0b81ac01b07ee540de70815b353bfca449e6e7ede372e5","title":"Creating an Arc Through 3 Points","path":"/ideCAD/creating-an-arc-through-3-points","children":[]},{"id":"ci_3c05f7ba503eb831a6fa32f53db0fd4fdcada23dca69acd9ed8437785387f1ad","title":"Creating an Arc (Center-Radius-Angles)","path":"/ideCAD/creating-an-arc-center-radius-angles","children":[]}]},{"id":"ci_7d698a763fa6d15c09c1fb59def80efdffadaf40238492d54e92e41ca312c2f4","title":"Ellipse and Elliptical Shapes","path":"/ideCAD/ellipse-and-elliptical-shapes","children":[{"id":"ci_7bcde181896a4bf91d5b12296cff3115fa5ec38b30ab0d99cb1eceebba68be5e","title":"Creating an Ellipse Corners","path":"/ideCAD/creating-a-ellipse-corners","children":[]},{"id":"ci_ec30dfdf38f44177919b43041968595e52858ba4e056ab53e5bd3710c4df1c0f","title":"Creating an Ellipse Center-Corners","path":"/ideCAD/creating-a-ellipse-center-corners","children":[]},{"id":"ci_eb4b98f7ce91e856ea5fc7cfa02b8b822c198cd079df9c483b038a66c678d203","title":"Creating an Ellipse Midpoint-Axis","path":"/ideCAD/creating-a-ellipse-midpoint-axis","children":[]},{"id":"ci_3d35070350d5535fde0b6adc333ab408d30135d04a1181f4ef8d11b61614ee00","title":"Creating an Elliptical Arc Corners","path":"/ideCAD/creating-an-elliptical-arc-corners","children":[]},{"id":"ci_176d99e74aae67b3d3bffb906b5a7e9f6c92b225ed431a23c0d271b5eaf657a3","title":"Creating an Elliptical Arc Center-Corners","path":"/ideCAD/creating-an-elliptical-arc-center-corners","children":[]},{"id":"ci_06fe809cdbd4af325314504808d09acc8db1928cc3121feeb3ec7c0fd8d89276","title":"Creating an Elliptical Arc Mid-Axis-Angles","path":"/ideCAD/creating-an-elliptical-arc-midpoint-axis","children":[]},{"id":"ci_a7f34a5e1bb1babe77fb2103daa20ba6be354061c4984f0e9c633b9dcdc99d44","title":"Ellipse and Elliptical Arc Settings","path":"/ideCAD/ellipse-and-elliptical-arc-settings","children":[]}]},{"id":"ci_14ec1202b7fe2d7144dacfb0ca25944facdd13b80cbdea4d06e7864c16dda128","title":"Raster Image","path":"/ideCAD/raster-image","children":[{"id":"ci_80c4afaf2a940bacc65449e1b1851b5f56ee3183c2e106e80888738c4b2324fe","title":"Adding a Raster Image","path":"/ideCAD/adding-a-raster-image","children":[]}]},{"id":"ci_1fc0bcb7e5ba9b98c3897bf8005252aac846e179d07949a0c025ed7940bfcfa2","title":"Revision Cloud","path":"/ideCAD/revision-cloud","children":[{"id":"ci_38e5a88393b3a7571bafdf779bef640fb64987e87abae7eae4fb559786b051f6","title":"Revision Cloud Settings","path":"/ideCAD/revision-cloud-settings","children":[]},{"id":"ci_067eacdc7ecae0ce1ab7f4f756ccab82bc81d7d05fbd5a45e80167cd76015890","title":"Creating a Revision Cloud","path":"/ideCAD/creating-a-revision-cloud","children":[]}]},{"id":"ci_77ddaa3a140ba3aae879dbd7559994ff5bf3c98eb3fac798e0ded1cd85fe72e7","title":"Pattern Path","path":"/ideCAD/pattern-path","children":[{"id":"ci_0cef3fa8ecc1ff8f1ec03c9b552d11da05298f21f1ab4ba5e9e232ac01591939","title":"Pattern Path Settings","path":"/ideCAD/pattern-path-settings","children":[]},{"id":"ci_940624d9e9a2c31161af2ea998f8288d307c4404e507454869a9aa75ca2eeb2f","title":"Creating a Pattern Path","path":"/ideCAD/creating-a-pattern-path","children":[]},{"id":"ci_aa9083f110a31a4b265707f127dd0ef17cab111378d053b7077f7dd0c372304f","title":"Define a New Pattern Path","path":"/ideCAD/define-a-new-pattern-path","children":[]}]},{"id":"ci_b013701dffe6a57b806193383906be232bdd5264f6a94e2b1e3860cffc1c75e1","title":"Entity From Primitives","path":"/ideCAD/entity-from-primitives","children":[]},{"id":"ci_1137ba6b9035024bf37d40c8476733e61b59cf481c72323c93b6b1fa643b76ca","title":"AS Calculator","path":"/ideCAD/as-calculator","children":[]}]},{"id":"ci_3b3ebaa713b6c7cd8cda2b83cd54fcb0d07fd56296e3967fffa86f0d4a22e0a4","title":"Editing Model","path":"/ideCAD/editing-model","children":[{"id":"ci_a884c18536b496ee81bc0547a2d4e84ac099a3522872e8d67ddf25190b2eebbf","title":"Repeat Last Command","path":"/ideCAD/repeat-last-command","children":[]},{"id":"ci_4eb147696e63ed787945fdc95347df1f981c1af2c000434d1275fce18c91b8c2","title":"Generate 2D Drawing","path":"/ideCAD/generate-2d-drawing","children":[]},{"id":"ci_80f6f9798edf409e4ddf19a0c8dbc7b7650be19994b8cdcbd4344b98f64f65c2","title":"New 2D Window","path":"/ideCAD/new-2d-window","children":[]},{"id":"ci_2e545b422240765d6a2f01cde2b45257e91b8705225ca900d39c31673df4b0fd","title":"Move","path":"/ideCAD/move","children":[]},{"id":"ci_53edef80adbbbed4e7e1ca4875e2dc34f7be0c6432d3e11a9dc5fbadbef3c2b4","title":"Rotate","path":"/ideCAD/rotate","children":[]},{"id":"ci_762fe4621241034d50cdce6f866825fd5919ebe251740e04db9781951b3f26f2","title":"Mirror","path":"/ideCAD/mirror","children":[]},{"id":"ci_880f19e8e04137b0c0d28b94f764d3cb894fd0a1a6ec3e16c7a30399219ad965","title":"Delete","path":"/ideCAD/delete","children":[]},{"id":"ci_767aa299ddb2475c2720d9e3527cde3ed5f2f2869749fc52e68be970305c1c7a","title":"Stretch Node","path":"/ideCAD/stretch-node","children":[]},{"id":"ci_db8229f279499af63a8a84c9af2655ac7511eccb1f49d48e2dabe65444ce5c84","title":"Rotate Node","path":"/ideCAD/rotate-node","children":[]},{"id":"ci_efdaeabf267dda9a8cf942c82dc8bfe6f4e8b40c8360065d3dd2bf3749818b96","title":"Fast Move","path":"/ideCAD/fast-move","children":[]},{"id":"ci_d87f3b0b180330cd7e1be334ab2649275b5cdb53c7b82c5dd58bdbad0a19ea7b","title":"Align Entities","path":"/ideCAD/align-entities","children":[]},{"id":"ci_5c9b075277359c5871087ec927a261290996034c3e6764334e155246db1cc9fe","title":"Distribute Entities","path":"/ideCAD/distribute-entities","children":[]},{"id":"ci_462eea6392d697841f736a232540ee1b5af6c4f9c2b63e39089c3f937f8088be","title":"Label Entities","path":"/ideCAD/label-entities","children":[]},{"id":"ci_a7371a97809038f30bbb9799e5b1df04042ce74c0a0f1e24b1c29274cd9f9743","title":"Auto Label Entities","path":"/ideCAD/auto-label-entities","children":[]},{"id":"ci_7b7910e0646545bfea84ae2dabadc93ca27f19291f38c928eb59ef3cef56b157","title":"Scale","path":"/ideCAD/scale","children":[]},{"id":"ci_6639a7831e0cfe4206f03e14f25f948234c4ab0bd6669a47d55246b3ed93cd91","title":"Scale by Reference","path":"/ideCAD/scale-by-reference","children":[]},{"id":"ci_6bad1bbfebb7365a438b248353b0e87f95e4ac8bc833e1fb72f0f5523bb8615e","title":"Trim","path":"/ideCAD/trim","children":[]},{"id":"ci_486329a0ede4d9b1d8d1784b280c47cfa158c7d71cf3aacb7bcb743f4cbf6fd6","title":"Extend","path":"/ideCAD/extend","children":[]},{"id":"ci_af2fc6e6364078857a4fed087b5d165c6f37538944cdec0c86f701fd0e540831","title":"Chamfer","path":"/ideCAD/chamfer","children":[]},{"id":"ci_dadde2aae74905f47cdffa62d94ae5b288b79e4f521909662c4e93e060ec4a7b","title":"Fillet","path":"/ideCAD/fillet","children":[]},{"id":"ci_d4ca887805c417e16b49e2d578235d1bbe6c915843699dbd17e823b56aa937fe","title":"Make Block","path":"/ideCAD/make-block","children":[]},{"id":"ci_dce6058c0cb2e66a740f6cda379f22c9ba7a2dfafbb30187c6f914eb7617c368","title":"Explode","path":"/ideCAD/explode","children":[]},{"id":"ci_61bbb81e4aefb7ed48b9f24fb7e4dadec664148769f61cdd3b1dc222b205397b","title":"Offset","path":"/ideCAD/offset","children":[]},{"id":"ci_e4a20a919f8fdbc5062a3a1a47870e48ab25ea03055012548731ff665cfde896","title":"Break","path":"/ideCAD/break","children":[]},{"id":"ci_09d2063c90bf9ebfa10bc0921316ffdb8eefbd14954c8d17c483d4b773c23a4d","title":"Divide","path":"/ideCAD/divide","children":[]},{"id":"ci_b3a9988725d3a43aa78322a4647a31df3f18f3a36cc81e06d829b90239785b3f","title":"Join","path":"/ideCAD/join","children":[]},{"id":"ci_aaff65f403ff726951e4736ba7f2cc2d6ae10fb1586b00144b6d941851bcac04","title":"Mirror X","path":"/ideCAD/mirror-x","children":[]},{"id":"ci_0196af9732b07c7728c5f7b3d9a26392bdd5b4736d1387207aa8d0adf3f831ec","title":"Mirror Y","path":"/ideCAD/mirror-y","children":[]},{"id":"ci_3edf8b7ec3d5179582edf29c27eb400dcc956e87037b6c721ba28efe5feb443d","title":"Delta","path":"/ideCAD/delta","children":[]},{"id":"ci_52a450e68f2ebbb629bd62399d78d27b3f20fb297a6e35398f767c231c6d806a","title":"Insertion Point","path":"/ideCAD/insertion-point","children":[]},{"id":"ci_9f5195d2e6e9c349d2350f8a713e7f730cdca8d8790c8098b01bdff0ff199c12","title":"Draw Line Weights","path":"/ideCAD/draw-line-weights","children":[]},{"id":"ci_9765d8b264cf8d42172d055595573d848ca1eb8868be27a8e44047b36afad75f","title":"Story Copy","path":"/ideCAD/story-copy","children":[]},{"id":"ci_16ae9e84cd4b97101315fb371e3df3b5785624bc8b4babd35185adfa37ca3563","title":"Rotate Building","path":"/ideCAD/rotate-building","children":[]},{"id":"ci_127c0b77c8c36a77080770dcc3404ca31a69e177e8a2556b7372d1aa599ebe0f","title":"Incline Objects","path":"/ideCAD/incline-objects","children":[]},{"id":"ci_53eaa766306dbe0db29b3dbf5a4258ddec0573011270e6e929c36f2978aae05c","title":"Set Entity Direction","path":"/ideCAD/set-entity-direction","children":[]},{"id":"ci_135d51cf923a849542deae4e66aa61e3a28e79f9457c8e7d94f7eea7f1d4cfd6","title":"Copy Contour","path":"/ideCAD/copy-contour","children":[]},{"id":"ci_5be367f7950d61837f90efe3e979b4a39cf012df12fecad79b73337992792c6c","title":"Paste Contour","path":"/ideCAD/paste-contour","children":[]},{"id":"ci_cbdb0b642eb311f8d51143d5d1d3b7fa159de0166c59934303eac5da0e23397a","title":"Get Entity Settings/Set Entity Settings","path":"/ideCAD/get-entity-settings-set-entity-settings","children":[]},{"id":"ci_0f2f07beb40ea2d91aa99d44340a83cabaeec4189f05b3a0ddb28e9e0ec076e2","title":"Draw Similar Entity","path":"/ideCAD/draw-similar-entity","children":[]},{"id":"ci_260027be5b7d9a6162ad572ab43562a456e926bbea63ca1c2e96c66e2217199f","title":"Set Trim Algorithm","path":"/ideCAD/set-trim-algorithm","children":[]},{"id":"ci_68a15abcd74a516f5adb9b89b33611bca3407cc56142c9666bcf01931316e506","title":"Set Cantilever","path":"/ideCAD/set-cantilever","children":[]},{"id":"ci_a81208ddbda054b1497bfbf6f7af08a5ac01aea80aafd61a570bb08ecde908dc","title":"Define Seismic Isolator","path":"/ideCAD/define-seismic-isolator","children":[]},{"id":"ci_759075d423ea701248359d0b6b10219b00695d10f7a4a22ec16ca61290a3c8f9","title":"Drawing Order","path":"/ideCAD/drawing-order","children":[]},{"id":"ci_99f5785ebe1c73bb837faf2f2f70d555cf674bcfd2aab0f3d41aa84e67abad70","title":"Geometry Control","path":"/ideCAD/geometry-control","children":[]},{"id":"ci_021fe671915dcd2a073f73be04c6e106118b1d07b80f7002174610672c77772e","title":"Transform","path":"/ideCAD/transform","children":[{"id":"ci_1b97a2c72506994b61071d5f5c82ced3d00db291417832818b31d23fb56df2a3","title":"Transforming a Beam to a Shearwall","path":"/ideCAD/transforming-a-beam-to-a-shearwall","children":[]},{"id":"ci_6c2876d90c1cb311445516112db9efc97f3df345bb8aa05dcef00acb6bf196dc","title":"Transforming a Shearwall to a Beam","path":"/ideCAD/transforming-a-shearwall-to-a-beam","children":[]},{"id":"ci_a6ed79b6901466104f09a654972df0446b2dcf5be5322c14ae597601716b643a","title":"Transforming a Column to a Shearwall","path":"/ideCAD/transforming-a-column-to-a-shearwall","children":[]},{"id":"ci_9073e9fd17db1b99116f5a0abb95d4475c0a72b122c8ca3ece4f76623150bfec","title":"Transforming a Shearwall to a Column","path":"/ideCAD/transforming-a-shearwall-to-a-column","children":[]},{"id":"ci_cf01d0184887b8bf3027bc88b52ade62b602850b1d018d022845139bb5cd0249","title":"Transforming Circular Column to Rectangular","path":"/ideCAD/transforming-circular-column-to-rectangular","children":[]},{"id":"ci_fae5ce94168a1ead89fb4baad3dd79e1e4c80ce7fb39a43c7abab9f8f228d287","title":"Transforming Rectangular Column to Circular","path":"/ideCAD/transforming-rectangular-column-to-circular","children":[]},{"id":"ci_a9c1ad01adf1cdb80bda4770faa17b69e197d94f716e1ff8bf5b97f2089326cb","title":"Transforming Curve to Beam","path":"/ideCAD/transforming-curve-to-beam","children":[]},{"id":"ci_1ede1328de47249e2c695732c868260f7ec9cb32665780dd07672b8fbccbd043","title":"Transforming Curve to Shearwall","path":"/ideCAD/transforming-curve-to-shearwall","children":[]},{"id":"ci_e1c5037507a2b3bbb2d5c3a40d9265eb214fc16648be93de3d43c758532d79a5","title":"Transforming Closed Polygon to Polygon Column","path":"/ideCAD/transforming-closed-polygon-to-polygon-column","children":[]},{"id":"ci_941633b48554c620b496e0e056f02f933b78193a8724a2bfed9df33284e06b43","title":"Transforming Closed Polygon to Polygon Section","path":"/ideCAD/transforming-closed-polygon-to-polygon-section","children":[]},{"id":"ci_d7d1edd92c8ad8a03d26dd3b496c761b7281c3aa08db7eab2cea7ee78029ec42","title":"Transforming Polygon to Plate Section","path":"/ideCAD/transforming-polygon-to-plate-section","children":[]},{"id":"ci_a6e4be5305824146060105b1185eaf6ba44750e5937bd3d6531eb25b6e07c8f7","title":"Transforming a Curve to a Wall","path":"/ideCAD/transforming-a-curve-to-a-wall","children":[]}]},{"id":"ci_58ce7ae27f1938d86a8b1759a1ec2f1ce6d9dcbd710570bb1fc2206bf6f97aca","title":"Determining the Eaves Types","path":"/ideCAD/determining-the-eaves-types","children":[]},{"id":"ci_9cf7ef49b42b5a959e7dd3f8e07b2ea7164402469482dc0dd236c899349ff8e9","title":"Set Steel Delta","path":"/ideCAD/set-steel-delta","children":[]},{"id":"ci_d00d601c4bcd534dacf6428dc8be7125c9c48c9c5f17cd2a9cc18a4eb29f9ea2","title":"Explode into Single Elements","path":"/ideCAD/explode-into-single-elements","children":[]},{"id":"ci_4b4b50d97e2bb3d7605d6088ad07daf143b403b0511bcde84848b3b36d1f5312","title":"Show/Hide Nodes","path":"/ideCAD/show-hide-nodes","children":[]},{"id":"ci_51ef350a7a296bb364970752638556fcd6b1d6c5c07b001d9f48f4ccbd1e6194","title":"Fill Inside the Primitive Objects","path":"/ideCAD/fill-inside-the-primitive-objects","children":[]},{"id":"ci_70190ccf6391426f7d12c41bf1994dd7d0163845b36c752efec0547f1684e2d4","title":"Undo (Ctrl + Z)","path":"/ideCAD/undo-ctrl-z","children":[]},{"id":"ci_42818f4ba0a73d68001d072ccd77fb0e3ba545578da489fbdc94f39606eb82db","title":"Redo (Ctrl + Y)","path":"/ideCAD/redo-ctrl-y","children":[]},{"id":"ci_aaa8ab41a9e554b83dcf2ebf58d62216a416b5e68e9c28f5e0e79adb4c11740a","title":"Local Undo","path":"/ideCAD/local-undo","children":[]},{"id":"ci_863845a21abfffe7b4f0d98507db69b8ba06f6859637b324c7d1b041ee28e831","title":"Configure Work Planes","path":"/ideCAD/configure-work-planes","children":[]}]},{"id":"ci_478d9b5f9b80ec245b8dc1d0866d8fd247e823f32046a7b10634ecbb9d7a6f62","title":"Have You Tried This While Modeling?","path":"/ideCAD/have-you-tried-this-while-modeling","children":[{"id":"ci_6d41a22e8307e7e822e435fa6e6ed80865d1eff5a47221bade3d613d43720e57","title":"Select Similars","path":"/ideCAD/select-similars","children":[]},{"id":"ci_49f8e6e4ce77fc986f54a249e2d3f98356402c233c7f232da034722fbf3182c7","title":"Template Projects","path":"/ideCAD/template-projects","children":[]},{"id":"ci_691bab4ebf1f65ec804ec9c900f0e7a14d1ae86b2ad0f72f3674490e11226239","title":"Customize Toolbar","path":"/ideCAD/customize-toolbar","children":[]},{"id":"ci_283a099ca2faea42431c9deaf9cd03e934df59d5846a40ddb86cb52cb3047da3","title":"Quick Move","path":"/ideCAD/quick-move","children":[]},{"id":"ci_cae20f2ccf270b2dabd3adcfc450c8f9bceeb5a227db839ec489298e0d419824","title":"Save Compact (.cde)","path":"/ideCAD/save-compact-cde","children":[]},{"id":"ci_88b886f73c3a456104bb50b479c11b26f2518d335b204d1f7ca8925e23a0848d","title":"Move Building","path":"/ideCAD/move-building","children":[]},{"id":"ci_b1566aa09937f90a850673ab28a73d426cc3fd5576eea9e1fd455315ee6dd9a3","title":"Rotate the Building","path":"/ideCAD/rotate-the-building","children":[]},{"id":"ci_dc0ef170173bea17e7f2c5fc77ab25266f0f18537e942135ccaf18a478960c85","title":"Entity Search and Finding","path":"/ideCAD/find-entity","children":[]},{"id":"ci_25ff92c9c599b3c5c879983e62da4f996b47621334474623e2ccc2b3d0bd8079","title":"Close / Lock Entity Layer","path":"/ideCAD/close-lock-entity-layer","children":[]},{"id":"ci_ea8e97c149e480160683693b7306f2cbaafce6b4c7b0309bc58d1538bf305cfb","title":"Returning the Perspective Screen to the Origin","path":"/ideCAD/returning-the-perspective-screen-to-the-origin","children":[]},{"id":"ci_1255ea9fb29cd8659b71a435dc3490b30f09e5ba6b640efaacad5d1fdc4fa413","title":"Search Command","path":"/ideCAD/search-command","children":[]},{"id":"ci_8a3c4f5ed9297f07f59e5c4f4654037a1344199bf330504acfbfc24ac1e1c840","title":"Returning to Default Settings","path":"/ideCAD/returning-to-default-settings","children":[]},{"id":"ci_e40127b35aec6125c564e2a23c87e5a0c2401e26e9ead99151ee9c579380903b","title":"Error/Warning Control","path":"/ideCAD/error-warning-control","children":[]},{"id":"ci_fbecc6320aeb145b030c1d1945ae6fc4848352c50bb75282121a112d82547091","title":"Right Button Menu","path":"/ideCAD/right-button-menu","children":[]},{"id":"ci_5958ab0e9737bc1ee3968e287c11d4c5bf8f0f13657be6c8abb453da42d50c1c","title":"Ribbon Menu/Classic Menu","path":"/ideCAD/ribbon-menu-classic-menu","children":[]},{"id":"ci_660a1adb945682dfb3ff462abbc9d01035013966a4c09e1116eeaed8d7fdc3ca","title":"Dynamic Input","path":"/ideCAD/dynamic-input","children":[]},{"id":"ci_6f0d6d95248ad4aebbf6cf485903a830a2c635b40ca0a607dd0585fd12660d81","title":"Window Selection","path":"/ideCAD/window-selection","children":[]},{"id":"ci_74a377b988902b53613440f059bba0a7c46d99d692670d293afffb040a2baeed","title":"Show Active Story","path":"/ideCAD/show-active-story","children":[]},{"id":"ci_7cbb64936c0b450de6adfe9b22f00860ce21ea7c8f8fb125eb969f5011e87956","title":"Adding Pictures to the Report","path":"/ideCAD/adding-pictures-to-the-report","children":[]},{"id":"ci_f48b10721460227f71937ac98ef350742deeb34e159c86ea024fcc0946055890","title":"Adding Company Logo to Report","path":"/ideCAD/adding-company-logo-to-report","children":[]},{"id":"ci_7cf41f650af5758f28cf7b7989e153d4f6a454a1a9b3db6d93d2ea9aa46c4264","title":"Copy to File / Paste From File","path":"/ideCAD/copy-to-file-paste-from-file-1","children":[]},{"id":"ci_a7187f83aa47ac2cc55220f1371ce0b414567b4caba352c3b7239fa14a5c4ae2","title":"Learning the Saved Version of the Project","path":"/ideCAD/learning-the-saved-version-of-the-project","children":[]},{"id":"ci_c233a34e7e082cc1d0c19b2689243c332d877d54c90dd2f9682fc424868df11b","title":"Dividing the Working Screen","path":"/ideCAD/dividing-the-working-screen","children":[]},{"id":"ci_a97f4ec7f333eb5695b9a0c41e93cdf63a01358a46a9fbdedc97fab1ccc6af56","title":"Switching Between Menu Titles","path":"/ideCAD/switching-between-menu-titles","children":[]},{"id":"ci_f3ef9c256cb4f67624f9606c5a54edd9dd5502e72d1be82f5dab4d03993559bc","title":"Turning Off / On Menu Icons","path":"/ideCAD/turning-off-on-menu-icons","children":[]},{"id":"ci_aa6a9b8bc75d207ea14aa7536146c7d31b830174876f60996a57e7cd54ba6622","title":"Moving Slab Text to Another Location","path":"/ideCAD/moving-slab-text-to-another-location","children":[]},{"id":"ci_4c347183de622392d702d6145940cbd408e24f650e1abfe390f97497e92a93e0","title":"Auto Scaling of Ribbon Icons","path":"/ideCAD/auto-scaling-of-ribbon-icons","children":[]},{"id":"ci_b490c04232fcaf0ab4d11540af6bc8ee21cafa211c22e32c812291a26fdc55f9","title":"Customizing the Quick Access Toolbar","path":"/ideCAD/customizing-the-quick-access-toolbar","children":[]},{"id":"ci_064e6fe1969b72b8d873ed0c44039f2c17ec8d39f3c60025d8f1a4d2d3f2ddb6","title":"Alignment by Object","path":"/ideCAD/alignment-by-object","children":[]},{"id":"ci_d6c78c55f2417b1d517a6b0aa5aee153362adfbfa8a4e78ff3688e782cc7421d","title":"Get Settings from Object/Set Settings to Object","path":"/ideCAD/get-settings-from-object-set-settings-to-object","children":[]},{"id":"ci_b064f54cf682a54d2a6b5e44d6f43a3734f230ef11a13edbc7c2ebe1ad04842a","title":"Zoom In/Out on Drawing","path":"/ideCAD/zoom-in-out-on-drawing","children":[]},{"id":"ci_2e63eb8931b20006796b5b98b2d87f87fb7d861ccbe74246c81110391677c39a","title":"Easy Transition Between Windows","path":"/ideCAD/easy-transition-between-windows","children":[]},{"id":"ci_892b08de8189e77f7a83e87738133f4bbfe14585f4e199bb01eb57f069ff63a3","title":"Entity Information Box","path":"/ideCAD/entity-information-box","children":[]},{"id":"ci_51de2ac439e1bd27c7c9b2c3a0395c522cb9b6b30f868e618f1f8948ccb2b76e","title":"Command Line and Editor","path":"/ideCAD/command-line-and-editor","children":[]},{"id":"ci_a32ba993d96b11dcba84a122a2e34e765d965708e76b4350e4a7d800da902b87","title":"Alias Editor","path":"/ideCAD/alias-editor","children":[]},{"id":"ci_6fed4206d401363dfa5e67d20b1527156eb7b51e5264e0d9a89b2c0921cd3d37","title":"Panning the Drawing","path":"/ideCAD/panning-the-drawing","children":[]},{"id":"ci_8fcb259cedf56aaac9c765fdb17d23c0ef369404457aa51224ce038805c7536e","title":"Forward/Undoing the Last Process","path":"/ideCAD/forward-undoing-the-last-process","children":[]},{"id":"ci_74d5b39acf84775c3bf52d887f4d3be458c127bb5b927d55314c02f88b41862f","title":"Memorizing the Selected Objects","path":"/ideCAD/memorizing-the-selected-objects","children":[]},{"id":"ci_ea78bc894a3d658b0d2e1f58f1fd903c478e18d01f1f6af1d7ffc7fe31243061","title":"Movement in the Perspective Window","path":"/ideCAD/movement-in-the-perspective-window","children":[]},{"id":"ci_324e1b1a87bd072dc9e27a8d18b4c2c8ad8a82f045d2e840887076421d37af12","title":"Selection Groups","path":"/ideCAD/selection-groups","children":[]},{"id":"ci_f1e82390cc36e0994c111b7a3d6559edc271bc85437a4058e66874d82e664c78","title":"Selecting/Deselecting All Elements","path":"/ideCAD/selecting-deselecting-all-elements","children":[]},{"id":"ci_6bd68aac5b9977936ccf26ccba5ccab4a293d7246715b7f63435aa1dce26d7c2","title":"Working in Drafting Mode","path":"/ideCAD/working-in-drafting-mode","children":[]},{"id":"ci_d9c9e7143bc57279119c9d7a75ddb558566d67eb6e8409f66a2db9fc944d6624","title":"Zoom Window","path":"/ideCAD/zoom-window","children":[]},{"id":"ci_81a0d28f409a50a56ef6771ea8ae7bc1d72904bc8a69bb122dae2bbc12f6eda1","title":"Copying/Pasting","path":"/ideCAD/copying-pasting","children":[]},{"id":"ci_a72d5b869c72fbd5779424b1ef0c3f10048851e0c172cd6fd42eab8de5ec7156","title":"Enlarging as a Single Window","path":"/ideCAD/enlarging-as-a-single-window","children":[]},{"id":"ci_98784e84b188094ea16d801ada651d53b7706ae6b3bde7802a6522fa51f0fe3e","title":"Snapping the Midpoint","path":"/ideCAD/snapping-the-midpoint","children":[]},{"id":"ci_3809adb8b63cb37beb6f0177ca0b124b7c0afa864152b63f63e42c8477591150","title":"Parallel Copy with Offset","path":"/ideCAD/parallel-copy-with-offset","children":[]},{"id":"ci_998966a56f0cdb5e176a895486582c77669a9ed7deced466fe33a652a58a0a82","title":"Run with a Graphics Processor","path":"/ideCAD/run-with-a-graphics-processor","children":[]},{"id":"ci_e17ed62abae97e4fd946f064b7e911942659a426dff7a005fd234ce3f1e5f7fa","title":"Activating Advanced Snap","path":"/ideCAD/activating-advanced-snap","children":[]},{"id":"ci_00e59f174fd65b06d1e005b719bb36d0268fba67c2fad4f6073b242ee77efa4e","title":"Visibility of Objects on the Active Story","path":"/ideCAD/visibility-of-objects-on-the-active-story","children":[]},{"id":"ci_8086cfbee97b3c95bc7f99e11f9ba5d3342b13efd4c2b56a068f7e09bbe562dc","title":"Save Project Old Version","path":"/ideCAD/save-project-old-version","children":[]},{"id":"ci_9c1ab37d5afb6fce5ef42995f7cdbbe6895e6ea89425aa81dcea12369240b77c","title":"Draw Similar Object","path":"/ideCAD/draw-similar-object","children":[]},{"id":"ci_62c2759004ef7622527f795854bf0e6f0fd83971bda0f50487c0f1303d2a15d3","title":"Change Drawing Order","path":"/ideCAD/change-drawing-order","children":[]},{"id":"ci_eb0e28339593a52c1b6276a7ed9f7828f99405c8fd62335ecd4535d5e5a3a533","title":"Column Trimming","path":"/ideCAD/column-trimming","children":[]},{"id":"ci_6be0240b0586c40cb2a6d7d41ce90a6ac94618c88b39598ddeb68abea7127b67","title":"Select in All Stories","path":"/ideCAD/select-in-all-stories","children":[]},{"id":"ci_71a701b6d29574452a8b339e88e5e3e426f2dbb5e61e4d87d73a4de2bc3f225e","title":"Filtering Building Elements in the Perspective Window","path":"/ideCAD/filtering-building-elements-in-the-perspective-win","children":[]},{"id":"ci_50457e45dbf6fee792a01b80daad8dfb797aa0b0d11ec7f011d644ec5a8eb04e","title":"Straighten Oblique Axes Out of Contour Polygon","path":"/ideCAD/straighten-oblique-axes-out-of-contour-polygon","children":[]},{"id":"ci_405637e2cdcfb303bc83658934d403e74a174c9a3f48bd08e006ec72a1397381","title":"Change the Objects Name","path":"/ideCAD/change-the-objects-name","children":[]},{"id":"ci_7b6e7dd70a57ceffc4cf3daceb28cae425f89b38bf5f0d91f550ad0814963834","title":"Changing the Stair Travel Direction","path":"/ideCAD/changing-the-stair-travel-direction","children":[]},{"id":"ci_69ddc44ff350f046a5db5365983ad87b688b8f16b196ba3a2c966c818696c97f","title":"Incline the Objects","path":"/ideCAD/incline-the-objects","children":[]},{"id":"ci_10b667b01041e3163f2cbcb3e9a3cd435533298ed3497cefdc0275b4d929d7ae","title":"Block Drawings","path":"/ideCAD/block-drawings","children":[]},{"id":"ci_e178ba3095f7e623d621afef8fe53b473c3f853ac2c1af8aa49e0c34d1767495","title":"Setting the last step of the stair to the same elevation as the landing.","path":"/ideCAD/setting-the-last-step-of-the-stair-to-the-same-ele","children":[]},{"id":"ci_6a9f6720ea357adec67894f8650f07df2ac17ea70a95b2b98161ea2a049ba988","title":"Saving a Screenshot","path":"/ideCAD/saving-a-screenshot","children":[]},{"id":"ci_2ca925d778b6f9d31086b8dc335ef3501df2029d13c82b38c56028c53b748dc4","title":"Inclined Column","path":"/ideCAD/inclined-column","children":[]},{"id":"ci_9500e6df4be4457ddb8b6fd498ad9f8366c3da3bbe95386a3fca68afad4cb9df","title":"Transition Between Architectural Plan and Structural Plan","path":"/ideCAD/transition-between-architectural-plan-and-structur","children":[]},{"id":"ci_26e539fdbed878e37608f35ed15fc73ad6bf0507d886c52cbbda7dc51fa2fb3c","title":"Creating Slab Hole","path":"/ideCAD/creating-slab-hole","children":[]},{"id":"ci_3c1831784767985fc2f6267b4c1837ffd19e807684438db4c6090259076619e1","title":"Axis Information Text","path":"/ideCAD/axis-information-text","children":[]},{"id":"ci_86e494e2eb9e6755ad94023d212855b5de3f9f7a2f86612913686fe856692ab1","title":"Changing Input Units","path":"/ideCAD/changing-input-units","children":[]},{"id":"ci_8fa91519e9e488e51facd5445e655392baa40279b859852c1f09295a6c8a9e0b","title":"Finding Element Angle","path":"/ideCAD/finding-element-angle","children":[]},{"id":"ci_eda8ef87822165a48628bed83dbf52ddd9b014a81682b5f4942ec8446da14ab8","title":"Changing the Entity Layer","path":"/ideCAD/changing-the-entity-layer","children":[]},{"id":"ci_ce2774cceb708cbb5135f455b5907c9a1a60e0896e5bc3a85ef7fc74156f1009","title":"Creating a Slab with Free Mode","path":"/ideCAD/creating-a-slab-with-free-mode","children":[]},{"id":"ci_2bb810d650841692fe5c4441aaadce3351f4b42397aa6f4e78113581fc6d9bd9","title":"Autosave","path":"/ideCAD/autosave","children":[]},{"id":"ci_b7ac325c409e9564b09d7937d1187735575d1feeeeba9a13ab8904ca486bd98e","title":"Nearest Point Mode","path":"/ideCAD/nearest-point-mode","children":[]},{"id":"ci_3e641d8c0b4e0da7d54a64f2f14692a5c92f4cf478bad94f52fffcc265993bd4","title":"Command Information Box","path":"/ideCAD/command-information-box","children":[]},{"id":"ci_bc39f2f4fd020558954a45c985c623297d33047fa6ef0f0f0d81fbf23685910f","title":"Removed Unused Layers","path":"/ideCAD/removed-unused-layers","children":[]},{"id":"ci_4be7f81a984a5654cfd4d912eaa43c7f321c5ee8da235d96c3acab10c3b2aa17","title":"View Techniques","path":"/ideCAD/view-techniques","children":[]},{"id":"ci_9d8628e86f41c381eda02147bc761bb547134bc8278ff0f8d42eac772d234882","title":"Changing the Working Unit In Dialogue","path":"/ideCAD/changing-the-working-unit-in-dialogue","children":[]},{"id":"ci_94cbffb26f0dd97ee5b4418d83bf23ac1f78eb28fa8e537403294b672d8e769a","title":"Entering Object Settings","path":"/ideCAD/entering-object-settings","children":[]},{"id":"ci_8eac1cd0562d0c8b0b30d14d67ab690a30e4ad323b8d61e8745939c3e90294b5","title":"Vertical Frame View","path":"/ideCAD/vertical-frame-view","children":[]},{"id":"ci_713299e3de9082176b28544b926186a493139872c8308a1012da52839af2454d","title":"Nodes in the Perspective Window","path":"/ideCAD/nodes-in-the-perspective-window","children":[]},{"id":"ci_e6307538f08898c87b23003b9c55eef563a89ce5f43c46af46b0ec083bec8117","title":"Finding ideCAD Version","path":"/ideCAD/finding-program-version","children":[]},{"id":"ci_458de7b2f020e7a1bc8ce7b6c53e882ddecbef7d6038e426c839ccbf040a6bbf","title":"Check for Updates","path":"/ideCAD/check-for-updates","children":[]},{"id":"ci_6490a79768e40c58cad8c7f752ffc9d56dca6658941835adb89e499b788aa2ee","title":"Opening the Start Page","path":"/ideCAD/opening-the-start-page","children":[]},{"id":"ci_153effbc71bcba9ded2463f3f1944538e4cd770f24a4080647d8d202ce20684f","title":"Apply Settings to All Drawing Windows","path":"/ideCAD/apply-settings-to-all-drawing-windows","children":[]},{"id":"ci_0dc75fcb02228fd6576b8138854ea3f00026c5b42204d89ba151afb4337b1b2e","title":"Backup While Saving","path":"/ideCAD/backup-while-saving","children":[]},{"id":"ci_bd1d7fb704034b16bfed363aef23877b5297c106cdb0794d3c773d0cc5bd211f","title":"Saving as a PDF","path":"/ideCAD/saving-as-a-pdf","children":[]},{"id":"ci_8dfc2544719b6bf5395d5b70b9b09fa2baff00c06032699e302e0a8014d5f54e","title":"Show Toolbars","path":"/ideCAD/show-toolbars","children":[]},{"id":"ci_2b619b25b110c401aa768824f229657b6d4b4b7e2554ff5c725a745de471468b","title":"Show Coordinate Box","path":"/ideCAD/show-coordinate-box","children":[]},{"id":"ci_f2949db715be15a3fa781f36ee070b0f0df8a7f4e9f4298b96e4818bf3c4db82","title":"Calculation of Excavation","path":"/ideCAD/calculation-of-excavation","children":[]},{"id":"ci_9ae349af0d7cc92c17a622e99592566db79e4962657f1f84a1721f24675f4a86","title":"Take Elevation from the Terrain with the Elevation Point","path":"/ideCAD/take-elevation-from-the-terrain-with-the-elevation","children":[]},{"id":"ci_57fa5498342b8a7c4cfe02f48de67633edd83b73429a1d61313b1e0b203a3e44","title":"Sub Region in Terrain","path":"/ideCAD/sub-region-in-terrain","children":[]},{"id":"ci_c6665a6582d068065ff5901376eb9984f0f09ce9924c2b5dfa7ec8fd51f18041","title":"Terrain Quality","path":"/ideCAD/terrain-quality","children":[]},{"id":"ci_3cb197cb304f48f7e434638266db210fe8a0e99ee0152a50ac81804f4728e3ad","title":"Curved Wall's Chord Count","path":"/ideCAD/curved-wall-s-chord-count","children":[]},{"id":"ci_4d14dd2a41ccdb982217f546373263f0d103c65d2f2b807f2f7b14704c7a2db4","title":"Changing the Form of the Roof","path":"/ideCAD/changing-the-form-of-the-roof","children":[]},{"id":"ci_f242aed6b923ff5d1aebee4a22f414c13270d16b2678bc4b4b19855d11b9dbb8","title":"Saving Quantitiy Report as PDF","path":"/ideCAD/saving-quantitiy-report-as-pdf","children":[]},{"id":"ci_91cb87839dc602f7ceb9d6ff9073fdbdd3f81d2db505c0541024de2421254481","title":"Find in Perspective/Find in Plan","path":"/ideCAD/find-in-perspective-find-in-plan","children":[]},{"id":"ci_1a785c954f6ae892b4e254161af42e91e731a337e2d3cce5fbbb261308163292","title":"Changing the Insertion Point","path":"/ideCAD/changing-the-insertion-point","children":[]},{"id":"ci_c3467a26371203ba2a5ddd8ca3206c7a033837c9c8f1baf2263e1b1df138b485","title":"Creating the Vault Form","path":"/ideCAD/creating-the-vault-form","children":[]}]}]},{"id":"ci_14206107409e9975e4ec40e9ba7f9e60dcf46b9d192105cfa94949f86d5ae903","title":"Integrated Building Design","path":"/ideCAD/building-modelling","children":[{"id":"ci_e7e354b21330503d4c6285a500762ea5295a3ea2ab8ed8cc886072aa8d90dc14","title":"Integrated Design for Architecture","path":"/ideCAD/architectural-design","children":[{"id":"ci_a16e5db8cc9c5f7e375d78b7069683a197344854c20b82075c506ea8eee22671","title":"Wall","path":"/ideCAD/wall","children":[{"id":"ci_cab948cf14743769e96697faa80565e47df8b465e09ce890c1d22513f24d4d47","title":"Wall Settings","path":"/ideCAD/wall-settings","children":[]},{"id":"ci_2ad65cd0dfd8df29e7c1589638afb225fc5371476e19986be8fd756c92208a29","title":"Creating a Wall","path":"/ideCAD/creating-a-wall","children":[]},{"id":"ci_aee4d997648272fc9f6466ae2d9fe49b0b3148463cd4f3e3cbdb084d1afd4681","title":"Creating a Curve Wall","path":"/ideCAD/creating-a-curve-wall","children":[]},{"id":"ci_1e78c64c08f98d21d68d6b5b231f13c9258e2ae62ff1d4c195106723e024a392","title":"Creating an Arc Wall","path":"/ideCAD/creating-an-arc-wall","children":[]},{"id":"ci_2300446c8b79c8d011af2e85d3f844af7910d318d1e3249847952220ef97c7b0","title":"Creating a Circle Wall","path":"/ideCAD/creating-a-circle-wall","children":[]},{"id":"ci_232f793e1f855ff6310328211a16628e2fcbc9e414af3dbd214d5a784891eda2","title":"Creating a Continuous Arc Wall","path":"/ideCAD/creating-a-continuous-arc-wall","children":[]},{"id":"ci_2990205d201ea656976265c159b533fae62bc3bc0447a0183ad90660c08be224","title":"Chord Count of Curved Walls","path":"/ideCAD/chord-count-of-curved-walls","children":[]},{"id":"ci_e360e338402d313ef2672440ca586172cbf201d82eb40136416de7568bdd771d","title":"Creating a Rectangular Wall","path":"/ideCAD/creating-a-rectangular-wall","children":[]},{"id":"ci_8de0c128b46fa828802ae598ea7ba5610764b99c3cdff2bbbbef687ab5b6213e","title":"Set Automatic Wall Height","path":"/ideCAD/set-automatic-wall-height","children":[]},{"id":"ci_a8a44114bbd2a990370451e5c9db193ee5a7ee3c0883a8dd466758810f5f9154","title":"Giving Elevation to Wall Corners","path":"/ideCAD/giving-elevation-to-wall-corners","children":[]},{"id":"ci_4b1a51183cf255fb6b45dd1b0097ba2e4b515a2eb772553f26abb24daaba5f7d","title":"Break a Wall","path":"/ideCAD/break-a-wall","children":[]},{"id":"ci_28d8c4ee89dbf89a49a4412cc4d6102fba248532b2f9c639a4c5a649b857e2ff","title":"Join Wall","path":"/ideCAD/join-wall","children":[]},{"id":"ci_e0cf1fca769c05968382c7efa460f79945cac3e7ded2d2c4f4a0568ae123b9da","title":"Trim/Extend Wall","path":"/ideCAD/trim-extend-wall","children":[]},{"id":"ci_20bf66849863211fe3714041cd8d81a9742a314f620dee3afd26213d679c5bbf","title":"Set Wall Priority","path":"/ideCAD/set-wall-priority","children":[]},{"id":"ci_99fc7b709b2e522d425f5d89ce22d0f4175afbd99f81d8fc7506b39d4b1c2d87","title":"Edit Walls","path":"/ideCAD/edit-walls","children":[]}]},{"id":"ci_2aae7059fa24ddba210f86aa3d41d5cdc9bc59fda6b019a144eab133493c8d93","title":"Door / Window","path":"/ideCAD/door-window","children":[{"id":"ci_41931dc2d30add85b679814bd2ef88cf113c9a21ef1a40da356d457c2509ccbf","title":"Door/Window Settings","path":"/ideCAD/door-window-settings","children":[]},{"id":"ci_5fda20438b44123ab73c7bf21f11aa381d854104464900c59c03db9018847217","title":"Creating a Door/Window","path":"/ideCAD/creating-a-door-window","children":[]},{"id":"ci_4d693286a3db345bfa97551ea68bfaf660760251d2092b00b4dceb360c1fb3fa","title":"Creating a Roof Window","path":"/ideCAD/creating-a-roof-window","children":[]},{"id":"ci_039cff4bc57d7be93f684f5017c8cf42f3dbcfe96e2ab8b3b60dfa406ed917ba","title":"Creating a Corner Window","path":"/ideCAD/creating-a-corner-window","children":[]},{"id":"ci_6b82dad511833bda747d7b63997346e608b2e5958bb3fafac8246c9f414d08b0","title":"Changing Door/Window Opening Angles","path":"/ideCAD/changing-door-window-opening-angles","children":[]},{"id":"ci_ec0a6a31e7d64f3175ab01afd38c7d2384a549a7d1f58eb639e5caf8900ea9da","title":"3D Section Feature on Doors/Windows","path":"/ideCAD/3d-section-feature-on-doors-windows","children":[]},{"id":"ci_0b12a52d91ec874cf09d8d1ad763716027784159d7fdfa3c1c2a967f3d9de13c","title":"Breast Lines of Door/Window","path":"/ideCAD/breast-lines-of-door-window","children":[]},{"id":"ci_6df6fa476509a8a03b10f770afd93ff0bd29d6efb0dfa15c7032a076551552d2","title":"Door/Window Mirror Processes","path":"/ideCAD/door-window-mirror-processes","children":[]},{"id":"ci_4118eab4c25e3b389e3f15e370cd151c8a30a0531a7c685394f57060208252e8","title":"Distance Setting","path":"/ideCAD/distance-setting","children":[]},{"id":"ci_b221358b0b95dc6e9fef4dae85e601be4e8ef8cd5ddf90b6ff60d9c18902e844","title":"Change Distance Point","path":"/ideCAD/change-distance-point","children":[]}]},{"id":"ci_c74041dc91bf845c6d072693ebf6ce240b18c9f0052987b26b04237cd80f2995","title":"Creating a New Door and Window Type","path":"/ideCAD/creating-a-new-door-and-window-type","children":[{"id":"ci_44cb2d13417599bdeb64c15b08367c89cd8805967a4cc29fae7d3ae5a32e132d","title":"ODT Project","path":"/ideCAD/odt-project","children":[{"id":"ci_39c173fe598fa168bb582ce3713a7eb40c7331bed58d5b32c452444025705296","title":"Opening Dio Files","path":"/ideCAD/opening-dio-files","children":[]},{"id":"ci_d90dd53b13117b500b9cc342879b574a9595e1dd936b5e1aae751aad9139763e","title":"Creating a New Dio File","path":"/ideCAD/creating-a-new-dio-file","children":[]},{"id":"ci_a03be54f1d6262fc0e1368139d2998936eddf4b901ff5d8c25bc62b9d027e1ea","title":"Saving Dio Files","path":"/ideCAD/saving-dio-files","children":[]},{"id":"ci_8de57bb948e334baf90277e5d63197a526362c6dce14a05b682993bb2ea1e465","title":"Saving Dio Files with a New Name","path":"/ideCAD/saving-dio-files-with-a-new-name","children":[]}]},{"id":"ci_8a357da6a4f7ffba8d1b5aa38c172de0e505270e385a177c68c7919a210227b1","title":"ODT Design Settings","path":"/ideCAD/odt-design-settings","children":[]},{"id":"ci_00dc26681f149405c67d5d6f10f44f77d66035c11ccc0c9df82e0d85e6f015b1","title":"ODT Snapper","path":"/ideCAD/odt-snapper","children":[]},{"id":"ci_e4cb5a8c230dcb57c21d2589ab325f5d5b184d0a6ca52dd17453d811623749f8","title":"ODT Interface","path":"/ideCAD/odt-interface","children":[]},{"id":"ci_09fc46456ed2e6d64c219f13a39d3c6b01a4d67bd804961f9d41c8c944ab5bac","title":"ODT Object Drawings","path":"/ideCAD/odt-object-drawings","children":[{"id":"ci_c65f4139f2776962aab32cd330440467b7f5d68aeba535e12a2f1a70bd93143a","title":"Creating a Circle Case / Wing","path":"/ideCAD/creating-a-circle-case-wing","children":[]},{"id":"ci_0ae4c82c5451e7642dbed5d4ad97691d724e7d7d7182762f6cf923743db0cee7","title":"Creating a Rectangular Box / Wing","path":"/ideCAD/creating-a-rectangular-box-wing","children":[]},{"id":"ci_e1acfb87ee53344f6e0d8c0239e71936d042a5423a3354816f307d7e1b740ac1","title":"Polygon Creation","path":"/ideCAD/polygon-creation","children":[]},{"id":"ci_f1ae0b0a8d664616169c58b110a7b78f41f803d4c0fdff7f7bbce505cd601187","title":"Spline Creation","path":"/ideCAD/spline-creation","children":[]},{"id":"ci_16ee5204817ec5758a5d1f4addc3951d484be6c70f4a570efbe6898a09632105","title":"Creating a Separator","path":"/ideCAD/creating-a-separator","children":[]},{"id":"ci_9f37a0038d0fa633e2a0e5254ac40c5cc5050702f0c62c8199434d4c8a8bd10d","title":"Creating a Cavity Polygon","path":"/ideCAD/creating-a-cavity-polygon","children":[]},{"id":"ci_97b3166a4b78c183be5938c04760ce4e243c8e7849a5dc8deafadb25efe04d23","title":"Creating the Opening Spring","path":"/ideCAD/creating-the-opening-spring","children":[]},{"id":"ci_2efa3a00533615de1ba72244065b2f34f30b542c2cf5233d4ea5470687eee21d","title":"Creating Lines","path":"/ideCAD/creating-lines","children":[]},{"id":"ci_a65dde25b21d52066aa2cdb930a6736cef753daf071b7978dcef6e8e9ee6a4d3","title":"Creating Circles","path":"/ideCAD/creating-circles","children":[]},{"id":"ci_55979264391d1cf7d2ff3ff65a12f5241c5fa8b03556302cfa9ba5ab7451a05c","title":"Creating a Square Bar","path":"/ideCAD/creating-a-square-bar","children":[]},{"id":"ci_cb76a32f5221bdb841d91a00342626f470c87c125d8763d006f3da6249767b32","title":"Creating Case / Wing from Polygon","path":"/ideCAD/creating-case-wing-from-polygon","children":[]},{"id":"ci_8b9e43e632c4ced1771dd5bfd1864b862dab29ee6889b515dab181c995cf328b","title":"Creating Spaces in Polygon Cases","path":"/ideCAD/creating-spaces-in-polygon-cases","children":[]},{"id":"ci_d7506583c4ac37bb4bc7b538d3371198b07e695f82f1bd33a2e8ce85e6d09ffb","title":"Creating a Door / Window Handle","path":"/ideCAD/creating-a-door-window-handle","children":[]}]},{"id":"ci_182e1c77b8950b2d8b3b0eb53408b32889e7f72e59463990ca1c7d1b2afed373","title":"ODT Object Edit","path":"/ideCAD/odt-object-edit","children":[]},{"id":"ci_8e3a7b00f173a9ecbf17abceaccefd4d6086c366b548cc8e4cf9a8cfaa04e605","title":"ODT Transformations","path":"/ideCAD/odt-transformations","children":[]},{"id":"ci_3dc568ad5d8f46e430a29ce4327cf83cf186157973d566ff1deaa435c2ec66ea","title":"ODT Cases","path":"/ideCAD/odt-cases","children":[{"id":"ci_9cfebd19ae0cdd18ff865aecd3d978613ef42a16231672df7d1e2fee6d6e5db1","title":"Determining the Wing Rotation Axis","path":"/ideCAD/determining-the-wing-rotation-axis","children":[]},{"id":"ci_7c0e10d1e720ceb100753383e40052720f0212c672906c498b9b9410b127594e","title":"Keep the Case / Wing Edges","path":"/ideCAD/storing-the-case-wing-edges","children":[]},{"id":"ci_7ed70e3e18162dd68f07cd1216b79b3bb390fa2881aa5be5b5f73e5acccbf053","title":"Case / Wing Enlargement / Shrink","path":"/ideCAD/case-wing-enlargement-shrink","children":[]},{"id":"ci_5f6cf2c04f16a5716882e818363e27a1e620674adcaf0b3680220dfe76faaeb2","title":"Reverse the Direction of the Case Polygon","path":"/ideCAD/reverse-the-direction-of-the-case-polygon","children":[]},{"id":"ci_10a3ae4e3064b96eb6e61f4ec634f36831c7e7c88fc31f27a98ca2b0f7ff0479","title":"Opening a Space in the Box (For a New Wing)","path":"/ideCAD/opening-a-space-in-the-box-for-a-new-wing","children":[]},{"id":"ci_34e7e369ecbff47e5da6d947af324e84f9bbdbde277a9711e18ea99dcaf2e345","title":"Drawing Sashes in the Void in the Case","path":"/ideCAD/drawing-sashes-in-the-void-in-the-case","children":[]},{"id":"ci_d33bd5df30bd97127db3cf8737820239f52efcaa882d2cceb946aa566f01881e","title":"Establishing the Frame / Wing-Object Connection","path":"/ideCAD/establishing-the-frame-wing-object-connection","children":[]}]},{"id":"ci_f4d931be8c617f479ea2390e1606fd05d49f6521558b48d2a2202b55ba437db7","title":"ODT Materials","path":"/ideCAD/odt-materials","children":[]},{"id":"ci_e47b49f7016375b9af7840892bea25a78a025a637832073f0fa332f0025aa7ed","title":"ODT Parameters","path":"/ideCAD/odt-parameters","children":[]},{"id":"ci_9cdd8bd891280f9869b593bd82ca1fbb3e0d89605d18889d650daf8a5437f747","title":"ODT Profiles","path":"/ideCAD/odt-profiles","children":[]},{"id":"ci_05a5274e10ef36cf4ea4ae52ea5324c13eed12a1179fa18fdb4a3cd7be761836","title":"Creating an ODT Step by Step Window","path":"/ideCAD/creating-an-odt-step-by-step-window","children":[{"id":"ci_eead192bccbcec58b44e5533515c027dda0be5555fb0310b7f342bb296bb7777","title":"Creating Window 1","path":"/ideCAD/creating-window-1","children":[]},{"id":"ci_0ff62436ba87e4382745ee057f65ee8ccb7dcc0bc55c3129abf0a6771c8f7c6d","title":"Creating Window 2","path":"/ideCAD/creating-window-2","children":[]}]},{"id":"ci_89a4ee54e54cb387ec8797f7d3f285a148db197ce9f3eaa904c8d6acbcf81857","title":"ODT Step-by-Step Door Creation","path":"/ideCAD/odt-step-by-step-door-creation","children":[]}]},{"id":"ci_390f9985c06fed8cf66e247a3e8c6dbfb8b8024bb71c46f9fbd633857bde2165","title":"Stairs/Ramp","path":"/ideCAD/stairs-ramp","children":[{"id":"ci_c56078b95982b7ad0ad3755737d2fc959c149f9af88a83c5e84b9d4aaae67c14","title":"Stair Settings","path":"/ideCAD/stair-settings","children":[]},{"id":"ci_3f92d596dd2c0b5fe86bb7eeaf1e4d1b86800121df2b1b7eb3f0dc45fb56c07d","title":"Creating a Stair","path":"/ideCAD/creating-a-stair","children":[]},{"id":"ci_dddbbc2af40c2248ab98f83b26f07a643b40c50daa0227d208e204c6122dfc76","title":"Editing the Stair Settings","path":"/ideCAD/editing-the-stair-settings","children":[]},{"id":"ci_7ce41a9de0cf1e10c434606206be2220eb8478e2af1c11a109c8a23a9bebed54","title":"Draw the Stair Section Line at Plan","path":"/ideCAD/draw-the-stair-section-line-at-plan","children":[]},{"id":"ci_588462a0984fc9184adec863ed680de3912be022d43d81edb0881143bd239603","title":"Editing Stair Coating Thicknesses","path":"/ideCAD/editing-stair-coating-thicknesses","children":[]},{"id":"ci_a171d383e4e5b920e07bc37258acfd48ba9cb7d8969f567bc2aa01b991a71655","title":"Create a New Stair","path":"/ideCAD/create-a-new-stair","children":[]},{"id":"ci_31f65a72c86b473711992290a816475f135be731459b323c81dea9e7c314bdd4","title":"Add Stair Area","path":"/ideCAD/add-stair-area","children":[]},{"id":"ci_0170ff8760bfa4d5050f0d88cffd43c66b3e874c3d3acb03b9938adaef87ad43","title":"Deforming the Stair","path":"/ideCAD/deforming-the-stair","children":[]},{"id":"ci_dde8a2fbefca51ab235e240063c6a3a1ac76197dee82b0b4b063e9f096196ed8","title":"Secondary Stair Deformation","path":"/ideCAD/secondary-stair-deformation","children":[]},{"id":"ci_aed884ecf7d8679d652231b36b09a1628fd2ddbf8d1c43193b51e9f7b0e9df7f","title":"Inverted Stair","path":"/ideCAD/inverted-stair","children":[]},{"id":"ci_d4ecbbf9620460833c0616956aca071b58ec29f0717490bfc5b4a3eafb428cf4","title":"Step Balancing on a Stair","path":"/ideCAD/step-balancing-on-a-stair","children":[]},{"id":"ci_b0037c80797dd3b7d5362474a4dce94722f543a03fe0d7b942269441b0239bd7","title":"Locating Riser Numbers","path":"/ideCAD/locating-riser-numbers","children":[]},{"id":"ci_6668071e526d11ac2959f85e49dc107f098bded9205dff3a4ae74554dc1cc633","title":"Top Tread is at Ceiling","path":"/ideCAD/top-tread-is-at-ceiling","children":[]},{"id":"ci_b6cc3d8b61a9e9d922a0992bfbf46f2552db272ca3206477ac152baa7fe12e22","title":"Stair Construction Method","path":"/ideCAD/stair-construction-method","children":[]},{"id":"ci_14a7a43378310049514faa831bbc20923c6ba894fdbe040728744238fb0f6f28","title":"Show/Hide Railing","path":"/ideCAD/show-hide-railing","children":[]},{"id":"ci_ce47b37df0b23349495f8e1431fd7cc4b264865ec5668ee2a16adc509363d612","title":"Changing Baluster Count","path":"/ideCAD/changing-baluster-count","children":[]},{"id":"ci_8ba3ee2a9bef8f6d848e08e0248c10aa45c673a6ef89e00c1a33cb3ba351f7a0","title":"Saving Stairs","path":"/ideCAD/saving-stairs","children":[]},{"id":"ci_acf40a84b9d2dae71a0b5a240317c1faf256bcc2fd22ba9a2df20446126efe0d","title":"Move Stair Text","path":"/ideCAD/move-stair-text","children":[]}]},{"id":"ci_447cc54c68b0d686f2fb74ced9dd6c2ddc39fb34332ecc7c3c6978a777677f63","title":"Creating a New Stair Type","path":"/ideCAD/creating-a-new-stair-type","children":[{"id":"ci_3bfad734a49a465329f74ce96f779878551751037faba28bb633726b1bf868a9","title":"Creating the First Stair Flight","path":"/ideCAD/creating-the-first-stair-flight","children":[]},{"id":"ci_4986ac1708ad67122826c1d5fbe58ba89ec16da58a7ace17c9a2861d63bc439f","title":"Creating the Stair Landing","path":"/ideCAD/creating-the-stair-landing","children":[]},{"id":"ci_b691df2988410063cb4288f80b6ff1813943cd07d40676e763477117181ddd01","title":"Creating the Second Stair Flight","path":"/ideCAD/creating-the-second-stair-flight","children":[]}]},{"id":"ci_077702d7332d758aa0f7333d8521f0539ff7da5b2a7bba8147a120af6cd4af23","title":"Creating a New Ramp Type","path":"/ideCAD/creating-a-new-ramp-type","children":[{"id":"ci_4294d3f0ac469e58c4cc64782fb51bac226a53c4113864c9c8bf39b2b7ead4a8","title":"Creating the First Ramp Area","path":"/ideCAD/creating-the-first-ramp-area","children":[]},{"id":"ci_3530e222fa7d315fe12c234cc2683760554175060dd7ab057fc31ec1e7aa730a","title":"Creating the Ramp Landing","path":"/ideCAD/creating-the-ramp-landing","children":[]},{"id":"ci_9273119c13155dcc53ce98f3cc51341f6e6fbcc83a384721a85a7aa38a445349","title":"Creating the Second Ramp Area","path":"/ideCAD/creating-the-second-ramp-area","children":[]}]},{"id":"ci_f4a7026330509ad7b95b0dfef0c8bfddbf5ac43a1312a627eff3269abd6faeb6","title":"Zone","path":"/ideCAD/zone","children":[{"id":"ci_d05e1eb73c9c1b9f4f9e302e3d37119d4f0ece9ad72c9f19203fcedb693bccfe","title":"Zone Settings","path":"/ideCAD/zone-settings","children":[]},{"id":"ci_8b8acfcdc65cc43cae538fa7031ce43dc790f2178303b6712216e12abb991551","title":"Creating a Zone","path":"/ideCAD/creating-a-zone","children":[]},{"id":"ci_b70593e5bbb598243cc0c8d4a524382cba2a3d20490aa42e297c442367b6a3cb","title":"Creating a Free Mode Zone","path":"/ideCAD/creating-a-free-mode-zone","children":[]},{"id":"ci_b1dc34f84669fb129687af7273774bb670b46606998e3ca0f12e752d82eb4de2","title":"Zone Coating Material Texts","path":"/ideCAD/zone-coating-material-texts","children":[]},{"id":"ci_5212be59ff2d5e6ebc0e7ea6b40faf64ca08abf9e822fa744c2a1a3aa2cec2d4","title":"Distance Between Texts and Angle","path":"/ideCAD/distance-between-texts-and-angle","children":[]},{"id":"ci_4da92b95808b372b9dada00b827340cd4e85a1c447b2769ae45b0f1ac586f097","title":"Zone Hole Settings","path":"/ideCAD/zone-hole-settings","children":[]},{"id":"ci_c0a20f240886dfccecb23318ac6ded3d81c567eaf0f3dd00dea9aedf2ceb9f6b","title":"Creating a Zone Hole","path":"/ideCAD/creating-a-zone-hole","children":[]},{"id":"ci_4df0e57533b2289df1829508a613809fa8f6cc37d1996b002c3cf45c3b84cbd2","title":"Moving Zone Text","path":"/ideCAD/moving-zone-text","children":[]},{"id":"ci_ac6f20a06d920a615927b4d0a4facca30b7d149aaf1451aac1a33f034232d77c","title":"Use Plasters for Area Calculation","path":"/ideCAD/use-plasters-for-area-calculation","children":[]}]},{"id":"ci_6b548a139c1afe5e3e0af2c99a54bb801407c6848cdc4336429c4da0ab99c65b","title":"Zone Edge","path":"/ideCAD/zone-edge","children":[{"id":"ci_5fe9d5964f5e36e91948a514626adfe1ff864cd94ff6e856c5b8a9c3124f6484","title":"Zone Edge Settings","path":"/ideCAD/zone-edge-settings","children":[]},{"id":"ci_9defa130cfec5755a82a1297ed3022b161f70c18cc8fcca2f61ed9f3d6ac628f","title":"Creating a Zone Edge","path":"/ideCAD/creating-a-zone-edge","children":[]},{"id":"ci_105b932f52eff796daf42cffe1cf7f362acd7e458cbc5d038ffdcd9bc69478ec","title":"Creating a Curve Zone Edge","path":"/ideCAD/creating-a-curve-zone-edge","children":[]},{"id":"ci_e390bc83ba79c01b93478658adfe223e808c3a318f1dc35fa884debbd70f5e94","title":"Create a Arc Zone Edge","path":"/ideCAD/create-a-arc-zone-edge","children":[]},{"id":"ci_360da6b7bd17e02133be3f3fdd2aaeaa6b9879885ddc7c347c64503aae7ef210","title":"Create a Circle Zone Edge","path":"/ideCAD/create-a-circle-zone-edge","children":[]},{"id":"ci_859c9cb1901a62b6285aa90368bdc20845879a927dcb2f6217a256f080babe88","title":"Create a Continuous Zone Edge","path":"/ideCAD/create-a-continuous-zone-edge","children":[]}]},{"id":"ci_b9dc6210434bca6bb67f2d49f3c6db081886a5fe011e9867fbafb8bbcd92c495","title":"Zone List","path":"/ideCAD/zone-list","children":[{"id":"ci_af271b47ed630709e07a2e3905ccc0ca776f7a4e462fb5583408b51b54a371f2","title":"Zone List Settings","path":"/ideCAD/zone-list-settings","children":[]},{"id":"ci_a797f7633a92315865c4dc01554a16f8b28a1a209aca63c487a3c3bf2583ecd6","title":"Creating a Zone List","path":"/ideCAD/creating-a-zone-list","children":[]},{"id":"ci_5ebb90404e81dac812a0548699dfc5b9ec5c6d16d7392c3eaa1e3b5617e67f97","title":"Determination of Fields in the Zone List","path":"/ideCAD/determination-of-fields-in-the-zone-list","children":[]}]},{"id":"ci_6497e533ba003e64a58e2545b1d162c7467f604f473445851ada8b06301a9ff6","title":"Jamb","path":"/ideCAD/jamb","children":[{"id":"ci_7ef73d1ce87c497b8e4089d189b9ea594d872e89427e64b588c6a09d4e2c72c0","title":"Jamb Settings","path":"/ideCAD/jamb-settings","children":[]},{"id":"ci_839072f675c3c8fef6e480a677e7430784baac46bff900b7d25bb5b5d93c333a","title":"Creating a Jamb","path":"/ideCAD/creating-a-jamb","children":[]},{"id":"ci_f2afb3d5a7aa54c396d968cfe27f043e4c8c1f8b448cc839075bf528b4735cdf","title":"Offset on Jamb","path":"/ideCAD/offset-on-jamb","children":[]},{"id":"ci_eabea6e5c7362116c81350dd147129b5969e0057bf5fefa1f21a5d1c23ec3fed","title":"Creating a Jamb Profile","path":"/ideCAD/creating-a-jamb-profile","children":[]},{"id":"ci_e2d70e328da00014ad2034ede471dc958a96fef76327ee03a0f60cfbed5cb16e","title":"Selecting Jamb Profile from Profile Archive","path":"/ideCAD/selecting-jamb-profile-from-profile-archive","children":[]}]},{"id":"ci_8175733200fc82e8c0896ca5a8ec2c416ba17b3c1f88957c884bc022b1fb7a7c","title":"Curtain Wall","path":"/ideCAD/curtain-wall","children":[{"id":"ci_546f6fc8321a6909c783231f359ca9fb70c58d619b3aabe205b0761376641191","title":"Curtain Wall Settings","path":"/ideCAD/curtain-wall-settings","children":[]},{"id":"ci_93cdac5342e9317c2c6821feeff8a0048b4178b387e71a698ee1cfd83b2cbe1e","title":"Designing the Curtain Wall Model","path":"/ideCAD/designing-the-curtain-wall-model","children":[]},{"id":"ci_b66f3a6dd34260ecfc7fd0b9533e910bcaed2c92d935690c1b1f4cb8b1d13d74","title":"Creating a Curtain Wall","path":"/ideCAD/creating-a-curtain-wall","children":[]},{"id":"ci_87f8a2b965dec92d893131350be6c7bd958c7b6ef783359fe0cadbbb2c35e651","title":"Curtain Wall Drawing Detail","path":"/ideCAD/curtain-wall-drawing-detail","children":[]},{"id":"ci_f6f9961285d6ad3a4393b7dc52de659df8b567a25f0eadc8d058f53ac14bb5da","title":"Defining a Door/Window on the Curtain Wall","path":"/ideCAD/defining-a-door-window-on-the-curtain-wall","children":[]},{"id":"ci_5a907177bfe0d87d5b7e4a30ede5c46f25bd0168beaf57e42a0077d90bac7017","title":"Creating an Inclined Curtain Wall","path":"/ideCAD/creating-a-inclined-curtain-wall","children":[]},{"id":"ci_5ac97bbf7d0c7d465bd4d2cedef9320f8fee3e9c44b105d4233226391992128c","title":"Rotating the Curtain Wall Panel","path":"/ideCAD/rotating-the-curtain-wall-panel","children":[]},{"id":"ci_8745626a7964277b97b037ea57e49c125ceeedee4c99818f5e29d2117f8c98b9","title":"Editing Curtain Wall Item Properties","path":"/ideCAD/editing-curtain-wall-item-properties","children":[]},{"id":"ci_a24613cc1a48af02308056a496608c358844ed6322910309980a11d852111742","title":"Mullion, Transom and Boundary Element Intersection Priority Properties","path":"/ideCAD/mullion-transom-and-boundary-element-intersection-","children":[]}]},{"id":"ci_aa7883130f21c79a6d63e886ce61e6b667850579097d951bd6e6f6af35ca9d66","title":"Exterior Veneer","path":"/ideCAD/exterior-veneer","children":[{"id":"ci_ac55e70368a117cc4ff46fd90c6e805a77d648b63757b00f66c6c68ce2d94d8f","title":"Exterior Veneer Settings","path":"/ideCAD/exterior-veneer-settings","children":[]},{"id":"ci_ccb48c7febdecd311b18206f68cbb9b0453ed957de99c9d737c35288a1c0870d","title":"Determination of Unit Dimensions of Lap Siding With Gap","path":"/ideCAD/determination-of-unit-dimensions-of-lap-siding-wit","children":[]},{"id":"ci_d6bb2c02d8744e9b363abec6cc4617971b36f5149b8d1c453cd45742b21a373f","title":"Creating a Lap Siding With Gap","path":"/ideCAD/creating-a-lap-siding-with-gap","children":[]},{"id":"ci_a5a03354110c86595dc0bf8b03aa0af056a59623d7c10e2fa899e1830b815aa8","title":"Determination of Unit Dimensions of Lap Siding","path":"/ideCAD/determination-of-unit-dimensions-of-lap-siding","children":[]},{"id":"ci_232e1b1a8ab0ecfc1b1baf8a2f90a4cef8c4bf6b68753242f9677744bcf67ed2","title":"Creating a Lap Siding","path":"/ideCAD/creating-a-lap-siding","children":[]},{"id":"ci_fd7ce9df390515cc82a315f9365b79935cefa6ef8e8fc1dd44beacdabd8fceaa","title":"Determination of Unit Dimensions of Terra Cotta Siding","path":"/ideCAD/determination-of-unit-dimensions-of-terra-cotta-si","children":[]},{"id":"ci_4f57e88dde12637db75f669575843f2011eeee21a94312bdc66a25671687db06","title":"Creating a Terra Cotta Siding","path":"/ideCAD/creating-a-terra-cotta-siding","children":[]},{"id":"ci_0fed7ff262a4c7b5891702496f6f965265a2b24731460f0a32b76eaee04e45dd","title":"Show Material in 3D - Exterior Veneer Settings","path":"/ideCAD/show-material-in-3d-exterior-veneer-settings","children":[]},{"id":"ci_8d5e4f500cd8bf808b9a248446e86ab2b89a86f071f9ec00628c5351d75e0a5e","title":"Exterior Veneer Height","path":"/ideCAD/exterior-veneer-height","children":[]},{"id":"ci_0246558957b340fc897acda264226ec97ae738dabf93ddb633b2a1437ac5ec5e","title":"Jamb Under Exterior Veneer","path":"/ideCAD/jamb-under-exterior-veneer","children":[]}]},{"id":"ci_c7c5610b41b3b827f9932d8354974f0cb8f9db9592e76e8f04c75c2c7241c248","title":"Railing, Baluster and Handrail","path":"/ideCAD/railing-baluster-and-handrail","children":[{"id":"ci_688de8ce9fa36316667c34b8853eefb72966d2bad534bdd7d7d484986c8df1d2","title":"Railing Settings","path":"/ideCAD/railing-settings","children":[]},{"id":"ci_e09b015b69fa8c4fe31ea2919152feacd2a5f98db27efb21dd5444a3ee9d204e","title":"Creating a Railing","path":"/ideCAD/creating-a-railing","children":[]},{"id":"ci_31cb5be498379e60ad61433714ce420498eb55296b08a979b2ac5601db322b13","title":"Creating a 3D Railing","path":"/ideCAD/creating-a-3d-railing","children":[]},{"id":"ci_42c5ccf2f8d340e02a3014d2da1c0bde753d7a09f55dc8e0a963c60ce45ab901","title":"Creating Railing over Objects","path":"/ideCAD/creating-railing-over-objects","children":[]},{"id":"ci_b9c66e783d80f47420b2ca1975f782f8f3432a31b0880f4f15305b07d728e229","title":"Railing Path and Layout Settings","path":"/ideCAD/railing-path-and-layout-settings","children":[]},{"id":"ci_80f9d0def908bfcef4d54192e765b93ed49abd78901152366ad9612124f852b6","title":"Editing Railing Elevations","path":"/ideCAD/editing-railing-elevations","children":[]},{"id":"ci_35838c46a42e3165086bf0f3e668378da0f7dfff69ebda1b48a4b8e144c36aba","title":"Updating Railing 3D","path":"/ideCAD/updating-railing-3d","children":[]},{"id":"ci_45ccc69e41ce40b9f01af50eb88133b2585a159d1e801ecaacdc3c37fbaf4594","title":"Saving a Profile to the Archive","path":"/ideCAD/saving-a-profile-to-the-archive","children":[]},{"id":"ci_7b7a0b0f0a44f7296885cac559a0b4c13dd0bee45e00ec2fee85673abd05146b","title":"Loading Profile From Archive","path":"/ideCAD/loading-profile-from-archive","children":[]},{"id":"ci_e0802e03b9c8391bb8726e2820d03f94e99dd353221dd6d4665f8c4671184d84","title":"Creating a New Railing Type","path":"/ideCAD/creating-a-new-railing-type","children":[]},{"id":"ci_a868c199f5e1bf2744cc836f310e7c83b6b7e4b20b135a9fc47e6741cfc37ad1","title":"Saving Railing to Library","path":"/ideCAD/saving-railing-to-library","children":[]},{"id":"ci_bc8c882ea65c9a27def5ad7898ebe6611c43b9039fb528cecc0d10070a02269f","title":"Loading Railing from Library","path":"/ideCAD/loading-railing-from-library","children":[]}]},{"id":"ci_9430bcba36df17a3e7922507e79bf2890c26efb5afa4e3599c86aeb70c4c9dd7","title":"Sweep","path":"/ideCAD/sweep","children":[{"id":"ci_1ddb73578c8119eba0d2ad1896e52ebe5540a2af3fe40dbdf4c22fc754f43f54","title":"Sweep Settings","path":"/ideCAD/sweep-settings","children":[]},{"id":"ci_250bf1b922844e98b9cf52ceb86b11848692a8829b223cb70062eb96ef2ea3bc","title":"Creating a Sweep","path":"/ideCAD/creating-a-sweep","children":[]},{"id":"ci_ea1d916cf9080b506deb4f8f958cbb38274ac7f5751afd30c4405fcad64a77af","title":"Ceiling Cornice Settings","path":"/ideCAD/cartonpierre-settings","children":[]},{"id":"ci_d307e58422cf64faa6382a8f5876e92a36f34d3e335a2b4b523a1646034eb369","title":"Creating a Ceiling Cornice","path":"/ideCAD/creating-a-cartonpierre","children":[]},{"id":"ci_2791936dd0488984ad0d048309a05dea282ff0ff02ca0148901ea72999774bd7","title":"Baseboard Settings","path":"/ideCAD/baseboard-settings","children":[]},{"id":"ci_a375619eb9905f1521d6b773de51f8048e02724d694ec74fc39af6ab62e4846a","title":"Creating a Baseboard","path":"/ideCAD/creating-a-baseboard","children":[]},{"id":"ci_c308511ed0666277a61a5267f32ca10db49726484373d0c635d2e28a644e4378","title":"Border on Wall Settings","path":"/ideCAD/border-on-wall-settings","children":[]},{"id":"ci_c2cfe28f1a5490937019437399e7d2f0e598bb434db1d0944f8443b076dd0b41","title":"Creating a Border on Wall","path":"/ideCAD/creating-a-border-on-wall","children":[]},{"id":"ci_0b027d4cd932277e5e82be13230a3e806838b6821e8d0a7d7e14d3ad16ef2eb3","title":"Cordon Settings","path":"/ideCAD/cordon-settings","children":[]},{"id":"ci_d4b4ec497278a7d6a58e4e08edf0b9d62e52502824874b1af6c96ab33fbce90f","title":"Creating a Cordon","path":"/ideCAD/creating-a-cordon","children":[]},{"id":"ci_2374cac45113b0ba104663d8eb31bd22816cf4bea74872642c1c6cc61baee7d3","title":"Roof Gutter Settings","path":"/ideCAD/roof-gutter-settings","children":[]},{"id":"ci_4808971a42cef1b05865bff9cdc7b42d92f1097f29eb5dfe33daf63917845dd7","title":"Creating a Roof Gutter","path":"/ideCAD/creating-a-roof-gutter","children":[]},{"id":"ci_88cf309c6ccb8134abd9529ed9f4d6be4733bf2241243f28e3fb1294a557b576","title":"Dome Gutter Settings","path":"/ideCAD/dome-gutter-settings","children":[]},{"id":"ci_7b21754a6c3c2b2ebb7275d3c25059d39801ff2c3f967d2315b1ca433f9590ab","title":"Creating a Dome Gutter","path":"/ideCAD/creating-a-dome-gutter","children":[]},{"id":"ci_5aabb18f0352f75c8888c489124cf642a71085ca3cd4daf269da0942ca63a4f2","title":"Sweeps Drawing Modes","path":"/ideCAD/sweeps-drawing-modes","children":[]},{"id":"ci_bc96ac2dcf1331efeb832458784fa6212ef96c23f4bda0f0331989d0b72b4023","title":"Sweep Operations","path":"/ideCAD/sweep-operations","children":[{"id":"ci_9c9929647a36af75d890c52b63cbd6292ee70919086530cc9ab556782077f8dc","title":"Define Local Offset to Edge","path":"/ideCAD/define-local-offset-to-edge","children":[]},{"id":"ci_5869d9c927d2fb21ded2d8d3d7117a58e3bf374595849ed94e4f9ce03814ed93","title":"Remove Local Offset of Edge","path":"/ideCAD/remove-local-offset-of-edge","children":[]},{"id":"ci_0dba944818e0a4d8ae4c0f845b20b0c104eace5e74fd4d9d7711228dc3ce52c0","title":"Define Offset to Edge","path":"/ideCAD/define-offset-to-edge","children":[]},{"id":"ci_5dc4a7119a3fe6a3a28675e87e7feb7e3ab9d55b621949c2dba4b259ad8309ce","title":"Remove Offset of Edge","path":"/ideCAD/remove-offset-of-edge","children":[]},{"id":"ci_3a42f6bbb0230760d74cbdcb47a601756892751e48c9c64d8e5ea6aaa156e1ba","title":"Define Inner Cut to Edge","path":"/ideCAD/define-inner-cut-to-edge","children":[]},{"id":"ci_557a18c881db1f836673e77f01419e8cad9505b0494bd54fdd07b499993f00ea","title":"Remove Inner Cut of Edge","path":"/ideCAD/remove-inner-cut-of-edge","children":[]},{"id":"ci_b22b9d1786e2fff53f4d315b5d052d279d5fff474d0335d0f9d54c95c2171c4f","title":"Define End Cut to Edge","path":"/ideCAD/define-end-cut-to-edge","children":[]},{"id":"ci_003e858cce1599d5ebe5dd826b78dc1274383f723393300bfd4fbd4887a2e9ec","title":"Remove End Cut of Edge","path":"/ideCAD/remove-end-cut-of-edge","children":[]},{"id":"ci_ac3633024fc33952c59482f223f3284fe311d33cf6ea7bc4410ff47b8c50e702","title":"Hide/Show Edge","path":"/ideCAD/hide-show-edge","children":[]},{"id":"ci_6dcf54036349b22d025ee39e35f3e8afd76ac9874b8733985eb6e4828d1f183a","title":"Hide/Show Edge Part","path":"/ideCAD/hide-show-edge-part","children":[]},{"id":"ci_e5822f58a46673b99a90f4150fc426928ade4ef8b0ad218f8520e8e35dc84381","title":"Change Edge Part End Angles","path":"/ideCAD/change-edge-part-end-angles","children":[]}]},{"id":"ci_02e4d712e1dc7d3e77b7dbfd2c5d3c95bcc7303744a72d839039187bfac935b5","title":"Transforming a Closed Polygon to a Polygon Profile","path":"/ideCAD/transforming-a-closed-polygon-to-a-polygon-profile","children":[]},{"id":"ci_8a6b3c62a5f632e91501cd8e7e4c232767d378b28e6a0406a5ce2c385cc4c17a","title":"Profiles","path":"/ideCAD/profiles","children":[]}]},{"id":"ci_b4adba0bd66d210d9b4022ae26845b1ad69d60ca62ef719b046111b06fbb0a44","title":"Terrain","path":"/ideCAD/terrain","children":[{"id":"ci_84ec7d89df38b9b8144b4699d61e11b81add717c68610ad7136d4ed735064192","title":"Terrain Settings","path":"/ideCAD/terrain-settings","children":[]},{"id":"ci_0cadc0682843ee11b501681e171d36420ca8f2111e6ee93402b43b98a2bdfe42","title":"Creating a Terrain","path":"/ideCAD/creating-a-terrain","children":[]},{"id":"ci_1261f586116534918a2647ff4f9e3e2c7ef636f3bce89d35c5034fa1171818bb","title":"Creating an Elevation Point","path":"/ideCAD/creating-a-elevation-point","children":[]},{"id":"ci_d91195b8ffdc9c1270d3f2350da4e4e8922d8cfcd8e902a81eed5c6707b811eb","title":"Creating an Elevation Line","path":"/ideCAD/creating-an-elevation-line","children":[]},{"id":"ci_685e349ab1e9926842fe9a86111d7620f19dd6fcb8b6874657845e0641657bcc","title":"Creating a Plateau","path":"/ideCAD/creating-a-plateau","children":[]},{"id":"ci_951d4089d2c5ca162390c4aa57ae5963b7f96f32c8819f3b48a4e44edf97ca82","title":"Creating a Hole (Terrain)","path":"/ideCAD/creating-a-hole-terrain","children":[]},{"id":"ci_bca2ba282f4067c2fff34a0460f2f69ec33f9b8e361adca055d32652122dc067","title":"Creating a Sub Region","path":"/ideCAD/creating-a-sub-region","children":[]},{"id":"ci_1e847af89ba53800c197a41dfc9f98d6f53952e8b20d154737819db35e58ff81","title":"Get Elevation From Terrain","path":"/ideCAD/get-elevation-from-terrain","children":[]},{"id":"ci_dae40bfa15dbcddc1878a8ef9d5ea6cd7f006c5875a1cc1a2a8481d2f38cbcc4","title":"Adding Depth to the Terrain","path":"/ideCAD/adding-depth-to-the-terrain","children":[]},{"id":"ci_348da23ae406300eac3d7c836740b85c7af861288d6453c4201bc8813c142415","title":"Editing Terrain Settings","path":"/ideCAD/editing-terrain-settings","children":[]},{"id":"ci_08cedf4b833c49817a9e323b52ea982dee09ad51c75be775b86ab709a65b9926","title":"Elevation Adjustment in the Terrain Sub-region","path":"/ideCAD/elevation-adjustment-in-the-terrain-sub-region","children":[]},{"id":"ci_abe3f42ba1e711d6dab319be0e5e6c3a59b5de1376e0c0016a59520771fe7ab1","title":"The Detail Level of the Terrain","path":"/ideCAD/the-detail-level-of-the-terrain","children":[]},{"id":"ci_da25c091021a73b8856c7109299a414ea37b518bbe25bdf83fff457dcc7d9108","title":"Excavation Calculation","path":"/ideCAD/excavation-calculation","children":[]},{"id":"ci_24fcc2e6109d5be88bff964500e0ce80a60631d1b2929e1084f440bcdc9590ce","title":"Select Terrain and Child Entities","path":"/ideCAD/select-terrain-and-child-entities","children":[]}]},{"id":"ci_cdc76bb8d4793484eac5646eeabe613150861d015cd5740f197ee1410e3b5b84","title":"Library","path":"/ideCAD/library","children":[{"id":"ci_ade95b0b9655d95b125eb0e5c3c9d41fd7cadc325c9da0cde7ffd3f396d4746d","title":"Library Settings","path":"/ideCAD/library-settings","children":[]},{"id":"ci_c7f0192fefb4223808d436e3485d92d751ed5d83ef5ab5b72f06d4ac29193ef8","title":"Creating an Object for Library","path":"/ideCAD/creating-a-library","children":[]},{"id":"ci_7a8b8ef6dcb0eb45e5859572444806fb0656f05f3d75fab6b99a05bc66b56472","title":"Set Auto Elevation","path":"/ideCAD/set-auto-elevation","children":[]},{"id":"ci_058cbaaa58a88e351eeb890c4453607526fd623d39ebc2c6e8bd671daf77fea7","title":"Angled Library Placement","path":"/ideCAD/angled-library-placement","children":[]},{"id":"ci_68ce71b6958c8fe24c1700fd69c08dabedb504fdc8e04d4413457a6599160eaf","title":"Update Library Elevation","path":"/ideCAD/update-library-elevation","children":[]},{"id":"ci_32ca19d0de955ab5b4c382f35f6d7f922206d712f5623e7bfe20387bc820198d","title":"Show Materials in 3D Preview in Library Settings","path":"/ideCAD/show-materials-in-3d-preview-in-library-settings","children":[]},{"id":"ci_f4ab62d763eeb7e90c9d50a4a5cac143e8c4f9b9f37b117aa4047f57012232c8","title":"Draw as Bounding Box in 3D","path":"/ideCAD/draw-as-bounding-box-in-3d","children":[]},{"id":"ci_355ccf6a7dd9e40df9a9e5bd8ae3ab4247f4843bd5ec991db705d5cb7d0e8fea","title":"Library-Hatch Relation","path":"/ideCAD/library-hatch-relation","children":[]}]},{"id":"ci_081f4215a509ef09d4c293823e00eea18508c8ac2316c84e6aa826c8a0b8ea64","title":"Roof","path":"/ideCAD/roof","children":[{"id":"ci_e82f16e2465014a7bbc6481aebe3b2ef1f81848a1e682a51b5f24e7ed965b04b","title":"Roof Settings","path":"/ideCAD/roof-settings","children":[]},{"id":"ci_73c09cb43f9b056e8c39e127bed05fd185c0babe77604432762b1a86b4dcb9b2","title":"Creating a Roof","path":"/ideCAD/creating-a-roof","children":[]},{"id":"ci_32e683aef3ea11474736af4e04e1af2cb21971dcb079dbc4da40f10e2fa6db6c","title":"Changing the Roof Edge Properties","path":"/ideCAD/changing-the-roof-edge-properties","children":[]},{"id":"ci_ce26834547f192e622f25fcc5596c279e0df094fd0cd892a8227988555a01753","title":"Creating a Gable Roof","path":"/ideCAD/creating-a-gable-roof","children":[]},{"id":"ci_b8b888dd3144e7fb34045bd9be7c77cf1a26c18fa0e536065ca2bc2708a0eb6f","title":"Roof Plane Settings","path":"/ideCAD/roof-plane-settings","children":[]},{"id":"ci_7994068ac252b6262e5f307a4fc1ede5dca712679f08d9cf9a2ae3107d374c38","title":"Creating a Roof Plane","path":"/ideCAD/creating-a-roof-plane","children":[]},{"id":"ci_56ab59e93fb579fba78130acd3c2d9fdb4e7e07b595debfacf8e32bc82c65e9f","title":"Creating a Roof Hole","path":"/ideCAD/creating-a-roof-hole","children":[]},{"id":"ci_ed08b84830cc63c70935c3eb9d44e96ee7ff556b1041c366561af45406830e3d","title":"Creating Roof Details","path":"/ideCAD/creating-roof-details","children":[{"id":"ci_f60397c693e9f545086b463e21d527bc11a371556332905269f7e17e618be946","title":"Rafter","path":"/ideCAD/rafter","children":[]},{"id":"ci_d41a0d20b90add0ccd2170604c27b5d223581179316712a7a6a9905241485c69","title":"Purlin","path":"/ideCAD/purlin","children":[]},{"id":"ci_cc61d868eb36279fe148afb517e463d2abfca1fd79d930056f3d124bfebb75aa","title":"Fascia Board","path":"/ideCAD/fascia-board","children":[]},{"id":"ci_2f2f5e266484d8596bc1dc877b2886afa236d30f9b487574b6a0c5f59ba79ad2","title":"Lath","path":"/ideCAD/lath","children":[]},{"id":"ci_d87447b25e96ce9c02dacf8571f2bfc08303eae8de65053e12caff77996df4af","title":"Hip/Valley Rafter","path":"/ideCAD/hip-valley-rafter","children":[]},{"id":"ci_1df168c12be50fe556122ac1ca7303790fae9e63480f78575bf16ce377af41f9","title":"Post","path":"/ideCAD/post","children":[]},{"id":"ci_5e801af32200f0d2ad7fcc4677768938b5117b44d887283d73fa1d8dde65c128","title":"Strut","path":"/ideCAD/strut","children":[]},{"id":"ci_6ca69ed36058470aef27141d92d966b7f2a7652f503b122653aeb999035bd27e","title":"Collar Beam","path":"/ideCAD/collar-beam","children":[]},{"id":"ci_4e04c17e3a9d24e1b7ed1ac5165207c32bf2d85499d877aad1b5b9ee91e986c6","title":"Trimmer","path":"/ideCAD/trimmer","children":[]}]},{"id":"ci_418eb739908746c7f1bf83560c22376ce8b52a3a9535c76129e81ce3b616ea17","title":"Trim to Roof","path":"/ideCAD/trim-to-roof","children":[]},{"id":"ci_ec86830e2daa91ad10776529d2b10c8f5f8545d46877f09927f012ccc76fac40","title":"Creating Roof Surfaces in 2D and 3D","path":"/ideCAD/creating-roof-surfaces-in-2d-and-3d","children":[]},{"id":"ci_7f07b29a6b57db5b29a2847ed69ef31561f5761b0346dc5c8b988b96db8e6bd8","title":"Exploding Roof","path":"/ideCAD/exploding-roof","children":[]},{"id":"ci_fc46d2b7a6e4205a88c988bcd44c10841e7fff1d9a90ee86acb9482f3122cea7","title":"Determination of Rafter Starting Point","path":"/ideCAD/determination-of-rafter-starting-point","children":[]},{"id":"ci_07d04cb024b104aa71249a0990715554e13c414b9a5c79342ca4845986312cf5","title":"Change Rafter Dimensions","path":"/ideCAD/change-rafter-dimensions","children":[]},{"id":"ci_b287c52ecef4f865003ebb01f4126bc62b5514df2e5e41fa18bae964a7b15ea0","title":"Delete Roof Element","path":"/ideCAD/delete-roof-element","children":[]}]},{"id":"ci_96341f373d2e558ef7564a893670a32b1ce92afba0804a375363281b1af59855","title":"Rainwater Pipe","path":"/ideCAD/rainwater-pipe","children":[{"id":"ci_b407a0ae4d756c26dafd5d79eac68120586f55b99c42fb949fa058c9e89a23c7","title":"Rainwater Pipe Settings","path":"/ideCAD/rainwater-pipe-settings","children":[]},{"id":"ci_e518ad7778b0deec443396da89e2e243a245a98ca928f503383e07a7c761beac","title":"Creating a Rainwater Pipe","path":"/ideCAD/creating-a-rainwater-pipe","children":[]},{"id":"ci_71edd7cae6ef3ee93054bd915f261701657971a4f9c8ab9139bfed176b17e1ba","title":"Direction of Rainwater Pipe Fitting","path":"/ideCAD/direction-of-rainwater-pipe-fitting","children":[]},{"id":"ci_98d3e7fcee90215a2f21ff30d2de2c1391994dd5f8279d4dcc764c446b192969","title":"Locating Rainwater Pipe Connectors","path":"/ideCAD/locating-rainwater-pipe-connectors","children":[]}]},{"id":"ci_8a8eb739d7c4ec535d6aaafca36ce47a8b26e57f3da5f6dabacb1ee2d98e4798","title":"Dormer","path":"/ideCAD/dormer","children":[{"id":"ci_080e49051cb4b94127876c6b82701e76302f7a4c7d82552642a3c90c0a1356a4","title":"Dormer Settings","path":"/ideCAD/dormer-settings","children":[]},{"id":"ci_e08f53995bd7b9576f9b06487bb326a697dff9416f443d8e99e5cda8fd0a9aaf","title":"Creating a Dormer","path":"/ideCAD/creating-a-dormer","children":[]},{"id":"ci_ff161bfc02d2605a0ef92f3dde3b5b6eb44e4da28198a95545fa78d2dcd21a8e","title":"Creating a Dormer Window","path":"/ideCAD/creating-a-dormer-window","children":[]},{"id":"ci_3b6cf1189d885c53199f6f21e94589fa9f0914af57c97f45fb1f54e77c65bbfd","title":"Changing Dormer Roof Angles","path":"/ideCAD/changing-dormer-roof-angles","children":[]}]},{"id":"ci_0dce1dc67ab6f9ffbe13bb96dfa91395b8dc267fa166ae6bdf54224135059c30","title":"3D Geometric Objects","path":"/ideCAD/3d-geometric-objects","children":[{"id":"ci_16c304de62766397e88266dc94def4817938917348c405441bdfde5882801b32","title":"Box Settings","path":"/ideCAD/box-settings","children":[]},{"id":"ci_41cac3be46a8b79c7814360a028443f455e7882d4fca9182719468df09f5ff96","title":"Creating a Box","path":"/ideCAD/creating-a-box","children":[]},{"id":"ci_511d6e6bc8ad41d9a2435655ae9dad8d8f9994af5b802474482bcfb1c9cac3dd","title":"Fillet in Box Object","path":"/ideCAD/fillet-in-box-object","children":[]},{"id":"ci_9ee06aaf9e77091cbbe1ddefb27198fb04a1aadf46e5ff5e82cdbabf6e8f66e9","title":"Extruded Object Settings","path":"/ideCAD/extruded-object-settings","children":[]},{"id":"ci_da1b649968a59b70f3d76671e9496dc0175609b8c3393de5acff3d91830d3948","title":"Creating an Extruded Object","path":"/ideCAD/creating-a-extruded-object","children":[]},{"id":"ci_b21c3d50677c3df5ced11f2b4705b6d8a0c63168150e5cc06d3402e312d57e47","title":"Rotating Extruded Object","path":"/ideCAD/rotating-extruded-object","children":[]},{"id":"ci_250265744ef1cd92dade528850f5a30c013bacaa81324b702fd667f4bc300565","title":"Sphere Settings","path":"/ideCAD/sphere-settings","children":[]},{"id":"ci_ce6241d1482fddc5af97f6398988585c610247fb50a67cb696af65765a5e4198","title":"Creating a Sphere","path":"/ideCAD/creating-a-sphere","children":[]},{"id":"ci_84693420bb92fad1e8dfb7bee25d2bd56a110c5297c7af34657c9aeb7f4771ed","title":"Sphere Object Arc Angle and Surface Adjustment","path":"/ideCAD/sphere-object-arc-angle-and-surface-adjustment","children":[]},{"id":"ci_bccf3903845fc33190213386d428dc5e6e743dcb7efee54e932f7475f0d4c499","title":"Revolved Object Settings","path":"/ideCAD/revolved-object-settings","children":[]},{"id":"ci_3cadd6381aa8d78ede9540501c8f5a61ea05d7a228311f492a3c50603f559071","title":"Creating a Revolved Object","path":"/ideCAD/creating-a-revolved-object","children":[]},{"id":"ci_e2225d3dc985c665283cf8282255e89f99fb6244a6842cf279b85ac0506c8705","title":"Setting Revolved Object Angles and Surfaces","path":"/ideCAD/setting-revolved-object-angles-and-surfaces","children":[]},{"id":"ci_7b968faa3d37f348996ef5dccf7d89460359b26c54bb514e77a55a57bd4300ae","title":"Tube/Cylinder/Cone-Pyramid/User Defined Tubes","path":"/ideCAD/tube-cylinder-cone-pyramid-user-defined-tubes","children":[{"id":"ci_79ba94f17afe485e97671b4f0bbda1a86a8785a69f7c1b5df64318b0ab0de30f","title":"Tube Object Settings","path":"/ideCAD/tube-object-settings","children":[]},{"id":"ci_010edf79d9e858716a244d340e7e34a71e994aed6a96f35992e79217025510d5","title":"Creating a Tube","path":"/ideCAD/creating-a-tube","children":[]},{"id":"ci_ef1cbb176a63e267cf5feff4555bf66a8ccb8fbd62a3a926c8c83dc8b91e8c59","title":"Tube Object Cover Options","path":"/ideCAD/tube-object-cover-options","children":[]},{"id":"ci_6d52faf605ce6c4f76fac483906232a05de756cf95160ea0f20c71019e381f66","title":"Cylinder Object Settings","path":"/ideCAD/cylinder-object-settings","children":[]},{"id":"ci_8e84203b3f332e0ee84ec833b6ecc3993c642c8e0fccf38d06f6879a79d03b19","title":"Creating a Cylinder","path":"/ideCAD/creating-a-cylinder","children":[]},{"id":"ci_578d097e884afa6922a71945d370d5197f004a35c2e1f891b036df59baa57b4e","title":"Cone-Pyramid Settings","path":"/ideCAD/cone-pyramid-settings","children":[]},{"id":"ci_2e9ebcfcf2d49cc41403255be4c94da7c3ed8343b56da4ed8c9bb8b139671753","title":"Creating a Cone-Creating Pyramids","path":"/ideCAD/creating-a-cone-creating-pyramids","children":[]},{"id":"ci_41800b5a93a3102607377ce36abea862821664dc3348dc56e69efd82924c5a04","title":"User Defined Tube Object Settings","path":"/ideCAD/user-defined-tube-object-settings","children":[]},{"id":"ci_12a9f94a627d841e9c2115536d1b6e218c7bba1e9ca35048085469e48661cb76","title":"Creating an User Defined Tube","path":"/ideCAD/creating-a-user-defined-tube","children":[]},{"id":"ci_4e69d240fc1a6e20a6b0c21ae82b4dba29a4d36d9f12cd6beec0b46e8e3a925b","title":"Segment Count of Tube/Cylinder/Cone-Pyramid Objects","path":"/ideCAD/segment-count-of-tube-cylinder-cone-pyramid-object","children":[]}]}]},{"id":"ci_46187f91db2c64467ba8ee10b8e42dcf5cf0ba570064ab51e209ca9c0b75591f","title":"Text (3D Text) Modeling","path":"/ideCAD/text-3d-text-modeling","children":[{"id":"ci_81bb62b7e3dd9d639d49cda6f90d86e993b26cc2aab1deb637c552cce5a55a6f","title":"Creating a 3D Text","path":"/ideCAD/creating-a-3d-text","children":[]},{"id":"ci_14c6ebfd8eeb821955f259dba2e9041faf1363d8fd77e7049777c13df06ada4b","title":"3D Text Settings","path":"/ideCAD/3d-text-settings","children":[]}]},{"id":"ci_e560f46c35f89eb9131bf578fa1ebc71e0547e0e99769f2984a1d785f39fe269","title":"Have You Tried This While Modeling Architecture?","path":"/ideCAD/have-you-tried-this-while-modeling-architecture","children":[{"id":"ci_3214655e637f0dfa1ef4cc51d4732723e66bb54170074931ca58d70bb1487547","title":"Automatic Wall Height","path":"/ideCAD/automatic-wall-height","children":[]},{"id":"ci_2d245cbd05dd48cde50d3eba9273078ebbaecaa396f41bdd6b21d90f2ac8ee6d","title":"Transforming into 3D with Extruded Object","path":"/ideCAD/transforming-into-3d-with-extruded-object","children":[]},{"id":"ci_0fa1283ae8e2666952d5abec1d94aef53f889b0a20b6ecc82711e6dfca75cabb","title":"Profile Section with Transform Command","path":"/ideCAD/profile-section-with-transform-command","children":[]},{"id":"ci_9d13456d82698535fbd20962f8ea9e175bdba64449e19d45f6910a999cadec5b","title":"Adding Door/Window Dimensions to Inner Dimension","path":"/ideCAD/adding-door-window-dimensions-to-inner-dimension","children":[]},{"id":"ci_81973a0546a5abdf1357a9be67b14994f2c30e4943e10275290ef2e471b3f579","title":"Rainwater Pipe, Body and Collar","path":"/ideCAD/rainwater-pipe-body-and-collar","children":[]},{"id":"ci_c4dfac2edbc1e90203af0811faa94dd25a44eac396fa25340326e23c4d1a22ed","title":"Location of the Zone Text","path":"/ideCAD/location-of-the-zone-text","children":[]},{"id":"ci_4526b9bec3c533f71b25615b930266fad63958cac7538b1dee6feed979baa333","title":"Taking Door/Window Symmetries","path":"/ideCAD/taking-door-window-symmetries","children":[]},{"id":"ci_bafa4d282e760ae6aefe7be9004cec0e6288d5aca759f5ba35a4dde96adcf892","title":"Method of Creating a Zone by Choosing a Contour","path":"/ideCAD/method-of-creating-a-zone-by-choosing-a-contour","children":[]},{"id":"ci_7701058f5289ae9e1c071778c1e3041a875cabeb94a84826f0f103a83c339a87","title":"Taking the Symmetry of the Jamb","path":"/ideCAD/taking-the-symmetry-of-the-jamb","children":[]},{"id":"ci_5fb32b24249ea624ea80da20e388fc54dea792c096ad7e0fc1b72dc11a6b4958","title":"Create Two Different Zones by Dividing a Zone","path":"/ideCAD/create-two-different-zones-by-dividing-a-zone","children":[]},{"id":"ci_d9560bca10bdf33e129dd5a66a18ec87b2837f944e8d765a107e38a6e0ecf76e","title":"Creating a Corner Window with Curve Wall","path":"/ideCAD/creating-a-corner-window-with-curve-wall","children":[]},{"id":"ci_1cdc1b1d0363f1f0f6a49ac85d0915cb585a130ce9cb54e907c1c8a1f54db66f","title":"Multiple Copy on Curves or Lines","path":"/ideCAD/multiple-copy-on-curves-or-lines","children":[]},{"id":"ci_748ae9631f9304292a02b28f9770b584ef0aa53d004ce14d98356e63c26e9457","title":"Creating a Hole in the Zones","path":"/ideCAD/creating-a-hole-in-the-zones","children":[]},{"id":"ci_fb46049108e193cda63b4ee884438f7397e82d70811cf9c73de062ee8ba31378","title":"Gable Wall with Trim to Roof Command","path":"/ideCAD/gable-wall-with-trim-to-roof-command","children":[]},{"id":"ci_5d6e3370000789ad9d3e5538803dca98868a0a5f2f5d1d941908a620aa324021","title":"Show/Hide Column Names and Sizes","path":"/ideCAD/show-hide-column-names-and-sizes","children":[]},{"id":"ci_569189f6a82b0b18b53ea8d5ca7f1eab9b4fabe43ec8edaf05215b217935a9c7","title":"Creating 3D Text","path":"/ideCAD/creating-3d-text","children":[]},{"id":"ci_cb0448d7068f0ce1d80387e0c63f9448ae49a440b58bb3f4500ade76c022ad62","title":"Adding Elevation and Height to Wall Corners","path":"/ideCAD/adding-elevation-and-height-to-wall-corners","children":[]},{"id":"ci_2eb7cf762d1219d0c1a72b66f3cdcc7a55450db86ed99e8c1c714c63960aae8d","title":"Removing Unused Materials","path":"/ideCAD/removing-unused-materials","children":[]},{"id":"ci_bb9b03400d0722743d813a723e065dc20dfd1f23b70485acf13f2f09498005b9","title":"Drawing Libraries as Bounding Box","path":"/ideCAD/drawing-libraries-as-bounding-box","children":[]},{"id":"ci_54bad6887975a1698724ef2a807bd25b7e3a7ef770b3364beb6b49abaf4a78bc","title":"Changing the Baluster Count","path":"/ideCAD/changing-the-baluster-count","children":[]},{"id":"ci_78b4b33a847bba694f3b8279f2e7f3e004937aa47dcac3d191f1d3d8a707a330","title":"Show Material in Exterior Veneer Settings","path":"/ideCAD/show-material-in-exterior-veneer-settings","children":[]},{"id":"ci_d10406f9ff38426f28e9907a22a7ed7e93061600bc8f1eca4754b717dadd882b","title":"Jamb on the Exterior Veneer","path":"/ideCAD/jamb-on-the-exterior-veneer","children":[]},{"id":"ci_6dcceeaf2a2e8c25f096b0d5efbd9d5563eef7cef804dac3b2dcc64d00b26900","title":"Railing Types in Library","path":"/ideCAD/railing-types-in-library","children":[]},{"id":"ci_bfd3c442435ad0ef53b2780a73c3d22c5364eb31b0241cfc20246024ab037d90","title":"Placing the Library Objects Compatible with the Slope","path":"/ideCAD/placing-the-library-objects-compatible-with-the-sl","children":[]},{"id":"ci_6156233a84fdc7f0f30b5890db33761df435be5c4313919c1d2f373c71b3e6df","title":"Automatic Gutter Creation","path":"/ideCAD/automatic-gutter-creation","children":[]},{"id":"ci_9314497c26d3365fe4fb48e18ed1c1ac7143503cc6ad5831690aca50754e1cb4","title":"Automatic Zone List Creation","path":"/ideCAD/automatic-zone-list-creation","children":[]},{"id":"ci_5f1396fa0cb34e2e5b6173e04832c8572f0024f588b15e836cef583211450aba","title":"Updating the Library Elevation","path":"/ideCAD/updating-the-library-elevation","children":[]},{"id":"ci_76cbb8a8f13fc553044b74e3ff413d534385af737e86166cd833be36f81b5210","title":"Showing Render Limits","path":"/ideCAD/showing-render-limits","children":[]},{"id":"ci_8feaeb92736e1ee348291e427b5bdb9475735894473acb3b43a2d0ddc20fbfe0","title":"Editing Texture","path":"/ideCAD/editing-texture","children":[]},{"id":"ci_745d5fe75b17f47752326272eba7aab210e93dd51a2fb831e3dfa0dc96e585ba","title":"Eave Types","path":"/ideCAD/eave-types","children":[]},{"id":"ci_e7e979a1e6fa4b35b7156fb9bae5897e11966540c6df69ed5f29b45d9b28d766","title":"Changing the Material of the Curtain Wall Panels","path":"/ideCAD/changing-the-material-of-the-curtain-wall-panels","children":[]},{"id":"ci_5bb0aca1b4be68d0e00b27a338ce77e5e4f33c243c9f1efa8d0306bdb6dbfe41","title":"Searching in the Menus","path":"/ideCAD/searching-in-the-menus","children":[]},{"id":"ci_18c966975ef5032bf21870671ecba9d417ff7dc52fbeefa24abcc75bf9abee3b","title":"Use/Do Not Use Plasters for Area Calculation","path":"/ideCAD/use-do-not-use-plasters-for-area-calculation","children":[]},{"id":"ci_390a5332df67f1a88afa66d9ea8937e0c73d456247e21eea8c30718d2e9d7c26","title":"Constrain the Section","path":"/ideCAD/constrain-the-section","children":[]}]}]},{"id":"ci_cf73111e549ccdb4ca68f085119115fe3673d70d059fda13870c7939ae5a5437","title":"Integrated Design for Concrete Building Structures","path":"/ideCAD/concrete-building-modeling","children":[{"id":"ci_c1b422306148980408704498030c30c96c302e8d29623e4a4f77ed4427f74377","title":"Column","path":"/ideCAD/column","children":[{"id":"ci_8445b16c2f74fb598dccdab2dcab29ea087f29c81d3fc63032cda2bd5355adc9","title":"Column Settings","path":"/ideCAD/column-settings","children":[]},{"id":"ci_9692be1493ce9ea84ee8348a2cc79d07378147247ccbf720d33c0544dc3f55cd","title":"Creating a Column","path":"/ideCAD/creating-a-column","children":[]},{"id":"ci_f1f38364d1da44f9bd4ff59a8c407ab2f3242b7ccae04a512aef378c5ad4416e","title":"Creating a New Polygon Column","path":"/ideCAD/creating-a-new-polygon-column","children":[]},{"id":"ci_d75a37822c25ac6c8aa0224a467c9cea441fbf81b1641c6de2527ad6be467140","title":"Defining an Arc-Shaped Polygon Column","path":"/ideCAD/defining-an-arc-shaped-polygon-column","children":[]},{"id":"ci_50c664bd59763a8bf0423450228ea50fa63f3c0b0bf9b8fbb9da11b2d7850c1c","title":"Creating an Inclined Column","path":"/ideCAD/creating-an-inclined-column","children":[]},{"id":"ci_73b651c84f3efc0c02a19a2729cadcce5a4d211b6ed0b8ca4bd1a6f2296b342a","title":"Colomn Growing Limits","path":"/ideCAD/colomn-growing-limits","children":[]},{"id":"ci_dfcdaba476b323b55fc07da8be5a7da8c3a1e22eab8e3306e9b7e109a86df1ac","title":"Draw Column Axis","path":"/ideCAD/draw-column-axis","children":[]},{"id":"ci_d42532900038b33d6ca89fb302f3a708929aa33e7aecd071c14b048f77695674","title":"Trimming Column","path":"/ideCAD/trimming-column","children":[]},{"id":"ci_0ff9f1db6f43cb5b0f5046fa077a9f9247fef62bb159443526243d99cae68d4d","title":"Change Column Dimension","path":"/ideCAD/change-column-dimension","children":[]},{"id":"ci_c9727fb1a32291fb496644fd0822bcf5b4e31e564416c660a9396b7105ab0d39","title":"Changing Column Alignment","path":"/ideCAD/changing-column-alignment","children":[]},{"id":"ci_8d46de5dc042691105cb809fe9030f27427e187b9a2bfb03540f5ce7f93badfa","title":"Set Short Columns","path":"/ideCAD/set-short-columns","children":[]},{"id":"ci_b1d5d2caa744dca571a5723a4f8410ec6ba7bbd7123428601aa10fe177f095c7","title":"Change Jacket Edge","path":"/ideCAD/change-jacket-edge","children":[]},{"id":"ci_5240f6b48891f0582817d8fb86fd97fc38dcd3c9de32be5ec9d6a47e9e4c0165","title":"Reset Jacket Edge","path":"/ideCAD/reset-jacket-edge","children":[]}]},{"id":"ci_451b9814af00238d81d925c125031573c90365d67d846b2d56435655735c9f9b","title":"Drop Panel/Pedestal (Column Support)","path":"/ideCAD/column-support","children":[{"id":"ci_960a9c60b0ca8cd81aeb2ce8cb91f5a870b1a35b6aeadeb03331f418049a98b7","title":"Drop Panel/Pedestal Settings","path":"/ideCAD/column-support-settings","children":[]},{"id":"ci_c08baa75bde400a4f6b7d5b9bfba7e626934f2cfeb4b318bf3041c986970df5b","title":"Drawing a Drop Panel/Pedestal","path":"/ideCAD/drawing-a-column-support","children":[]}]},{"id":"ci_2ae594d33f844ab85c5a5772f8167120ee73a6b4cea2d8e546af59bac2a81478","title":"Beam","path":"/ideCAD/beam","children":[{"id":"ci_5ab1d8e12966317fb0dc429d25f3a0255d74329021787bdd71e3d3258ce0424c","title":"Beam Settings","path":"/ideCAD/beam-settings","children":[]},{"id":"ci_b64a04a2c1d2c73cb6e435d93d686c61173d893052ae990217b00588a0f33c9f","title":"Creating a Beam","path":"/ideCAD/creating-a-beam","children":[]},{"id":"ci_4fd8044daa56e4077c2c2b7118d5e96b265f56746807f3ed88790fc1a3e2ca94","title":"Creating a Curve Beam","path":"/ideCAD/creating-a-curve-beam","children":[]},{"id":"ci_1a27fd47c77f8de8850c33b1a7f9ba0991e00e5a1576a2932daf290cbb8e2910","title":"Creating an Arc Beam","path":"/ideCAD/creating-a-arc-beam","children":[]},{"id":"ci_efefc2d2febed8e957c6864167f3a3ec5f60081bd334b6f80558ab067659333a","title":"Creating a Continuous Arc Beam","path":"/ideCAD/creating-a-continuous-arc-beam","children":[]},{"id":"ci_e1ee59d381874f42e033efcd78c165ccec6c90431316ead73f76b7815f480afe","title":"Create a Circle Beam","path":"/ideCAD/create-a-circle-beam","children":[]},{"id":"ci_e9ad25bf5aab6dca1b07b270114f29ec358f1faa679070d98e62fb0b79b32072","title":"Creating an Inclined Beam","path":"/ideCAD/creating-an-inclined-beam","children":[]}]},{"id":"ci_e6cf03662a93e83157b0cfc156ec998d006c2825749735370c83923d25c1d72d","title":"Shearwall","path":"/ideCAD/shearwall","children":[{"id":"ci_04cea35323d6399482ed64c274b347322ac9e2d90ebd06a74b3cce2f5754ccd8","title":"Shearwall Settings","path":"/ideCAD/shearwall-settings","children":[]},{"id":"ci_d89fac39e492dead736b42ae2f21048d2f836598b9dd59a4b93b79658131f0c6","title":"Drawing a Shearwall","path":"/ideCAD/drawing-a-shearwall","children":[]},{"id":"ci_4f330894ec1bc146103b9bd68da5ef02859c170aa9dfc9b643e90b36f4a5f749","title":"Defining a Shearwall Group","path":"/ideCAD/defining-a-shearwall-group","children":[]},{"id":"ci_4ee26feb4a12bfb6a79b2105618ac2ff2e45484adb3829cb47ab3c187475307b","title":"Drawing a Sub-basement Shearwall","path":"/ideCAD/drawing-a-sub-basement-shearwall","children":[]},{"id":"ci_555b133a9645ae6dc9c0c0caf61cb3bcfd68ec8904122afc4d0d7e3a7b6107f3","title":"Describing Short/Head Shearwall","path":"/ideCAD/describing-short-head-shearwall","children":[]},{"id":"ci_ef08fdf6536a315597b15e504ff352cc361f21c08c94c41b5b819e41a1b08935","title":"Changing Shearwall Length","path":"/ideCAD/changing-shearwall-length","children":[]},{"id":"ci_f2e3ba4a2d452352ce375147c3a670db19c7f0b14bca3f75dc66c15fc50f9491","title":"Creaiting a Reinforcement Shearwall","path":"/ideCAD/creaiting-a-reinforcement-shearwall","children":[]},{"id":"ci_4ccc2e8a982ec011d8f4c7c3aa5e0e7ee7153eec403f111ba32c8476a8911d74","title":"Opening the Shearwall Space","path":"/ideCAD/opening-the-shearwall-space","children":[]}]},{"id":"ci_19b8cd64841d74de7edbfc99eaae3b8cf58e7ec7c11a1c033212ac46fd8bc043","title":"Slab","path":"/ideCAD/slab","children":[{"id":"ci_eabc38ede4712dc96d4bf17ca550ff288debc76679c94b6c6385dc6535af52d7","title":"Slab Settings","path":"/ideCAD/slab-settings","children":[]},{"id":"ci_2cd74d1e3b4c7c4d82aa14c7ce39386461ee80021bcde7f376cbc246b0a9b0be","title":"Creating a Slab","path":"/ideCAD/creating-a-slab","children":[]},{"id":"ci_4c7789cdb9845c42a4454833b35bd81f08a1029831cf5885d2f76aa8fd0f39da","title":"Creating a Slab by Free Mode Slab","path":"/ideCAD/creating-a-slab-by-free-mode-slab","children":[]},{"id":"ci_d6c6f15757852383557ca248731fb1989328ecff0d44eaf7c86c1fb40ee41875","title":"Creating a Ribbed Slab","path":"/ideCAD/creating-a-ribbed-slab","children":[]},{"id":"ci_eda74f7034343a51821ee70b10f7fbe236f368f05b1020babf57738ca0f9d745","title":"Creating a Waffle Slab","path":"/ideCAD/creating-a-waffle-slab","children":[]},{"id":"ci_7f1fe62c848275c5273158113dc598b1215a832310f1692ab016d03e478e8a59","title":"Setting Typical Rib","path":"/ideCAD/setting-typical-rib","children":[]},{"id":"ci_540292489b8a08be353769cf5b4088ec9ca45dc7590df46c66f3029d1a82c6bc","title":"Creating a Slab Hole","path":"/ideCAD/creating-a-slab-hole","children":[]},{"id":"ci_85432aa420ef3403dec61f7e7e1a97c925bf458a162a9e61fc7199e4ebffa719","title":"Editing Slab Hole Rebar","path":"/ideCAD/editing-slab-hole-rebar","children":[]},{"id":"ci_fb9bfb56d09a85c5365dd29d3feb9c927a1d3ee9b1f7c331fd4f83eec6c110ed","title":"Creating a Line Slab Band","path":"/ideCAD/creating-a-line-slab-band","children":[]},{"id":"ci_e3ea6cda514eb3da124aca03f0b470b0c32b349509cedd8cd70ecdeff0d44678","title":"Creating an Arc Slab Band","path":"/ideCAD/creating-a-arc-slab-band","children":[]},{"id":"ci_0487fb536d4af23bfd28b0e5424f7cd4c71183c97bb7019807fafdcc5f74b4b1","title":"Slab Band Settings","path":"/ideCAD/slab-band-settings","children":[]},{"id":"ci_6ff7673bea3357fd71ebd57253b72d09c9e8e22d2f66be64d74f4f02c4ca630e","title":"Moving a Slab Text","path":"/ideCAD/moving-a-slab-text","children":[]},{"id":"ci_bfec948e3abff10c5b899abd9b9ea8f7ecd846cc6f605348ed38e3ff70125a18","title":"Draw Concrete Calculation Line on the Slab","path":"/ideCAD/draw-concrete-calculation-line-on-the-slab","children":[]},{"id":"ci_79872a7609b1071cc2bac1bdd373ecd6bed5cb4939122cd270d4ef1df7fb1c25","title":"Remove Concrete Calculation Line on the Slab","path":"/ideCAD/remove-concrete-calculation-line-on-the-slab","children":[]},{"id":"ci_318a7f7e15324e67435b2baf0d38fb7a9c106db144c6c46a5f4cf5b2ae938a1c","title":"Changing Concrete Calculation Line Geometry on the Slab","path":"/ideCAD/changing-concrete-calculation-line-geometry-on-the","children":[]},{"id":"ci_80850c4a194812493f78973a1a74ac1f1ad482ace8f8048e29b91ff84b2e525d","title":"Editing Concrete Calculation Line on the Slab","path":"/ideCAD/editing-concrete-calculation-line-on-the-slab","children":[]},{"id":"ci_718c3bf7ff6fc06b2a3a0dcd2cc33f6fcd697ab793723900eee1a494e08da0ea","title":"Defining Linear Slab Load","path":"/ideCAD/defining-linear-slab-load","children":[]},{"id":"ci_687435966d2986fcbcd98fe84a9c61553f728788d10c13f6646ead03e013bb47","title":"Defining Point Slab Load","path":"/ideCAD/defining-point-slab-load","children":[]}]},{"id":"ci_9d28e99e85dcaa99209619ed061eb601196150ae91b701cb8eabd5716a1764d3","title":"Slab Edge","path":"/ideCAD/slab-edge","children":[{"id":"ci_94a30c530000040b84c35c130d39599c78f94c559062b1cfa966fd1d22002b15","title":"Slab Edge Settings","path":"/ideCAD/slab-edge-settings","children":[]},{"id":"ci_bc0b6201376cd14544ef9cd7ff8695d9f2f714a07655cf07f0395f85db61dbab","title":"Drawing a Slab Edge","path":"/ideCAD/drawing-a-slab-edge","children":[]},{"id":"ci_2b13fad173fd141c5ede3e87ff876b8e6f99cc5f05da5cef346b61281f8b2bdf","title":"Drawing a Curve Slab Edge","path":"/ideCAD/drawing-a-curve-slab-edge","children":[]},{"id":"ci_24697605f050c40803abab326a6f734bc47e92dd2a0d7f5a441b745ed63b9133","title":"Drawing a Arc Slab Edge","path":"/ideCAD/drawing-a-arc-slab-edge","children":[]},{"id":"ci_8b1a6a861b06fa74ed72e68cb1a9208e62cc997c745b7317453fb0a8173dce5c","title":"Drawing a Circle Slab Edge","path":"/ideCAD/drawing-a-circle-slab-edge","children":[]},{"id":"ci_8b72efe81fa467b2b90add407e358aa83c5149b98681e1dd36f057aaee8f7502","title":"Drawing a Continuous Slab Edge","path":"/ideCAD/drawing-a-continuous-slab-edge","children":[]}]},{"id":"ci_4a48be38b3254582476e22d7f2639b87e0c28677b3cc8e575f56861ccff4f1d6","title":"Stairs Concrete Design","path":"/ideCAD/stairs-concrete-design","children":[{"id":"ci_e483eab81d20d2dfe31b786e802f872309e6a530ca9d7da9306ca65b5b998ab0","title":"Setting Stair Boundary Conditions","path":"/ideCAD/setting-stair-boundary-conditions","children":[]},{"id":"ci_b5e233d08ca86c1eaddce5e6e1bc86729b8bcf7fca7e1d81a8535af5ce153245","title":"Draw New Stair Concrete Calculation Line","path":"/ideCAD/draw-new-stair-concrete-calculation-line","children":[]},{"id":"ci_fba502dd59fede48efbf7f485f755930d9ecec122e9783dd943ff740798997e0","title":"Remove Stair Concrete Calculation Line","path":"/ideCAD/remove-stair-concrete-calculation-line","children":[]},{"id":"ci_621dcd2ca260c11bc9035a3dfa0041d97e1972aa19dbd1346a7de829f63f7c0d","title":"Editing Stair Concrete Calculation Line","path":"/ideCAD/editing-stair-concrete-calculation-line","children":[]}]},{"id":"ci_3f51baa00430c9032f6f1437fc571f6ed6c2dbbd8233f27a8f1a72985d0c7276","title":"Raft Foundation","path":"/ideCAD/raft-foundation","children":[{"id":"ci_e3125944ce4dc6e54582a8e25564e739a9e60a13209b020635e1da6976b638f9","title":"Raft Foundation Settings","path":"/ideCAD/raft-foundation-settings","children":[]},{"id":"ci_db259c4d4e3e38067b4a6747dc0b32559efa00dea514cd2624dc102f2ede51a3","title":"Creating a Raft Foundation","path":"/ideCAD/creating-a-raft-foundation","children":[]},{"id":"ci_c4132be97c3c2f5abefb60c926ded93cae6b9511c769041bc044faee5fe59eed","title":"Creating a Raft Foundation Hole","path":"/ideCAD/creating-a-raft-foundation-hole","children":[]},{"id":"ci_a10cff99b0beeab98e61dcff06f0c11de759527f834ef02761dbffb221ba756f","title":"Moving a Raft Foundation Text","path":"/ideCAD/moving-a-raft-foundation-text","children":[]},{"id":"ci_3f439d8c305d606e13f1f59ff72af33c643f8039a7ce3cebaa7ee562d4d0eead","title":"Draw Concrete Calculation Line on the Raft Foundation","path":"/ideCAD/draw-concrete-calculation-line-on-the-raft-foundat","children":[]},{"id":"ci_17f4ec2483033bc672575a92bf85fda12050b01ab4a026be7ef73754e3ff68af","title":"Remove Concrete Calculation Line on the Raft Foundation","path":"/ideCAD/remove-concrete-calculation-line-on-the-raft-found","children":[]},{"id":"ci_75c606c07e49931e0af0998298bd8730225b458def359413204454008914cac6","title":"Changing Concrete Calculation Line Geometry on the Raft Foundation","path":"/ideCAD/changing-concrete-calculation-line-geometry-on-t-1","children":[]},{"id":"ci_596c0b3ec71ba5c87eea69f5a2dd5f3730c8693370ac21b7ed5187357b370ebd","title":"Editing Concrete Calculation Line on the Raft Foundation","path":"/ideCAD/editing-concrete-calculation-line-on-the-raft-foun","children":[]},{"id":"ci_cbae4b8f8690b4fd55088208655610b78eeaaaa3d943b3d8470f296cc535ad6c","title":"Defining Linear Raft Foundation Load","path":"/ideCAD/defining-linear-raft-foundation-load","children":[]},{"id":"ci_59b1ae161ff8342f38461c975d69b56162bb6c1dd3005515386f7ec55e259dcd","title":"Defining Point Raft Foundation Load","path":"/ideCAD/defining-point-raft-foundation-load","children":[]}]},{"id":"ci_a6a2c641256795992f0b850e2b3ab7e3e39266206e71a8dc9ae186a0da9565ff","title":"Raft Edge","path":"/ideCAD/raft-edge","children":[{"id":"ci_ba508ff1a33c0596e80e794a3fac0b5a98565d17636b996e927e3f3380bcd29c","title":"Raft Edge Settings","path":"/ideCAD/raft-edge-settings","children":[]},{"id":"ci_e22d6b6a6b9ca32d130208d8021971d22995cc245af0df59a8487509ec85a44d","title":"Creating a Raft Edge","path":"/ideCAD/creating-a-raft-edge","children":[]}]},{"id":"ci_e3b9a0ff388519857158d99db00f131be18ac3c1e0be56bda37e3ce40da2f54f","title":"Pile","path":"/ideCAD/pile","children":[{"id":"ci_cc86c5adfb31d67c53673d9695f4344ea0f192eae109b4422f145cf67bdfa1d3","title":"Pile Settings","path":"/ideCAD/pile-settings","children":[]},{"id":"ci_ec31f7e0d6436ce7f7a00da36be6f1a8d8c10db076a6820ef5bb7e37641ce0ad","title":"Creating a Pile","path":"/ideCAD/creating-a-pile","children":[]}]},{"id":"ci_822a270f4c18d96b761e0cb9490a7a49314053fb344214d220453e884f2d1d80","title":"Single Footing","path":"/ideCAD/single-footing","children":[{"id":"ci_b0289f89013a31ce064fd4c6ac6a191ec9bf311ce62be0a33915182aaa442141","title":"Single Footing Settings","path":"/ideCAD/single-footing-settings","children":[]},{"id":"ci_373d08de30d0520f239f2686b7b1bb6392ab28ad514bd3ffb16b55cf8de27da1","title":"Creating a Single Footing","path":"/ideCAD/creating-a-single-footing","children":[]},{"id":"ci_f1fc208c751b4fb1eb94c68c6db22a64cf0312114699c60c54cd92c91e08d8ce","title":"Exchange Coordinates for Single Footing","path":"/ideCAD/exchange-coordinates-for-single-footing","children":[]}]},{"id":"ci_3e07094aef111a401a712cd8f394bb3491a02422a46eb2592f5752ba12697ed3","title":"Strip Footing","path":"/ideCAD/strip-footing","children":[{"id":"ci_67881754ea36041c5777b344220cae2b7adb2a07e0f061c5d5304f8d5c5bc680","title":"Strip Footing Settings","path":"/ideCAD/strip-footing-settings","children":[]},{"id":"ci_d3fe05505bb9d8ce6eaf0b1ee6429fb2434255298b4bae624817a1c1b355a096","title":"Creating a Strip Footing","path":"/ideCAD/creating-a-strip-footing","children":[]}]},{"id":"ci_e4a68582f5e245beba05bd204455fa16b611ca150ad8c9ae25d6cf7b8d73dbeb","title":"Foundation Tie (Connection Beam)","path":"/ideCAD/coupling-beam","children":[{"id":"ci_02d172c390ea2ca88c2a0980d5efc4436d3c07a3e934c2b161716fa993a49d5f","title":"Foundation Tie Settings","path":"/ideCAD/coupling-beam-settings","children":[]},{"id":"ci_bfbfd2cd87ca3627a4f32d65a2155f85e01c869c75f69cf933fe71a6abcc496f","title":"Creating a Foundation Tie","path":"/ideCAD/creating-a-coupling-beam","children":[]}]},{"id":"ci_b7d1f26a628f9bd7b8d37135bfefc5d0786d610b5ad7dd81fab11ff3c7c8b2ed","title":"Dome","path":"/ideCAD/dome","children":[{"id":"ci_611bad69bee1383d75e12dac2514dfeda57d4fa17c6df1815a527a6bde61af74","title":"Dome Settings","path":"/ideCAD/dome-settings","children":[]},{"id":"ci_e6da1302895415d8409c95162bea791dd6d562a3b840278316c66955f4b10a84","title":"Creating a Dome","path":"/ideCAD/creating-a-dome","children":[]},{"id":"ci_768041d6683aa9b136f61c45f11438db5fd21536b433658292f4d2ea7d659e7a","title":"Creating an Arc Dome","path":"/ideCAD/creating-a-arc-dome","children":[]},{"id":"ci_04e1d6399f2baa7acdd1f8a52d3bbd4354cc0a9b868af91b8d0fc6e3c71eeac4","title":"Creating an Arc Dome 3P","path":"/ideCAD/creating-an-arc-dome-3p","children":[]},{"id":"ci_d47e2aca2fd9306a73db772c31b7e1dce1a55518730d830d440520edf2d433f3","title":"Chord Count of Dome","path":"/ideCAD/chord-count-of-dome","children":[]},{"id":"ci_e68907adb4457cb4956ce2a0fe6ffb1e9ed42135888f000abcfca5ec0809cac5","title":"Setting Dome Restraints","path":"/ideCAD/setting-dome-restraints","children":[]}]},{"id":"ci_24168eef2322372cc86d1bc902b34caa4d0d179d50113e8b510422c8f4e9969c","title":"Vault","path":"/ideCAD/vault","children":[{"id":"ci_987d877054468b02fdd9f1e48c03ab99b006f695eaf2d62769b4192fcbc0ea04","title":"Vault Settings","path":"/ideCAD/vault-settings","children":[]},{"id":"ci_c4c59ec992d3ccf697b0dbce336b55b5b2f484d2f00a2d95f11e107c872a57cc","title":"Creating a Vault","path":"/ideCAD/creating-a-vault","children":[]},{"id":"ci_44d31e16b126b1cc40dbb98c862030db9918009a2e4c6417fc16a7a68f78855c","title":"Creating a Border Vault","path":"/ideCAD/creating-a-border-vault","children":[]},{"id":"ci_21d1912b4e7b00922577219974430dd938d38f8ff3f2bde716eb10f6ea9b39e4","title":"Chord Count of Vault","path":"/ideCAD/chord-count-of-vault","children":[]},{"id":"ci_698888cc8489da7cb4cd08c99f016507d7b3a8754002ff8e02fb250eb402b5ae","title":"Setting Vault Restraints","path":"/ideCAD/setting-vault-restraints","children":[]}]},{"id":"ci_6f42af27db4da4abb3ba9ca892769e25a6497269b0010c444d9e92c4bc3a0d86","title":"Pool","path":"/ideCAD/pool","children":[{"id":"ci_800feba2dec7ba4e295878c2565543dd415b39a606ae6408ab8a231a821dc019","title":"Pool Settings","path":"/ideCAD/pool-settings","children":[]},{"id":"ci_96d909279dd4363b7efbce2a9753b1fb65fd5c3a8ef640f6dac6be5809e2d8f7","title":"Creating a Swimming Pool","path":"/ideCAD/creating-a-swimming-pool","children":[]},{"id":"ci_6266c9b29549c8ea8d698b51ab021f44953b02413933e829acd1a21e31083f40","title":"Setting the Swimming Pool Surface Slope","path":"/ideCAD/setting-the-swimming-pool-surface-slope","children":[]},{"id":"ci_fa7ab4d71476490f56ed56591699f2ef59c3b32d1bdb671d5262e0a389ba522f","title":"Setting the Swimming Pool Surface Properties","path":"/ideCAD/setting-the-swimming-pool-surface-properties","children":[]},{"id":"ci_9ceff444b64535c6d480068b0666aa68658a5a8bd1b14a5265db4e3ede125362","title":"Setting the Swimming Pool Wall Properties","path":"/ideCAD/setting-the-swimming-pool-wall-properties","children":[]},{"id":"ci_acb02b87a1e3c2407fb4c5dbdccab48ad8cc853ec535aab9dcbd065401ff6d21","title":"Setting the Swimming Pool Cantilever Slab Properties","path":"/ideCAD/setting-the-swimming-pool-cantilever-slab-properti","children":[]},{"id":"ci_d2ae1dcb46f59b7c73bf17df283083bb2049070149ac9f7594dca168ddab07b4","title":"Delete Primitives","path":"/ideCAD/delete-primitives","children":[]}]},{"id":"ci_51500246eda22a40156202b8a79f3b0ba129345ff71b7d517596099fce98d582","title":"Retaining Wall","path":"/ideCAD/retaining-wall","children":[{"id":"ci_c74c472d43dc73f6273a50fe5611b4c1be87002afb0001c1567c086bc69e2006","title":"Retaining Wall Settings","path":"/ideCAD/retaining-wall-settings","children":[]},{"id":"ci_20ec4f34540acb2ce9b09e33dfc37e2db40d6ae9c12a66cc6b50bf8efe8b240b","title":"Creating a Retaining Wall","path":"/ideCAD/creating-a-retaining-wall","children":[]}]},{"id":"ci_cd922505a7daf5325382dbc4e87c74b5bc809901bc011897e15a860487631f45","title":"Well Foundation","path":"/ideCAD/well-foundation","children":[{"id":"ci_2e119557c75fac94eb777208aa7ba59d97ece4befed454f0950fd8eaff3d5780","title":"Well Foundation Settings","path":"/ideCAD/well-foundation-settings","children":[]},{"id":"ci_7f4f2a57d9d8661aeebe1448854cf907acd3890968d1b29c521db6c02bcbaa8a","title":"Creating a Well Foundation","path":"/ideCAD/creating-a-well-foundation","children":[]}]}]},{"id":"ci_abe2e33593558303ac0dbec9caa7fb6030d42ec8b32c1d4ee69c2195c1dcd07c","title":"Integrated Design for Steel Building Structures","path":"/ideCAD/steel-building-modeling","children":[{"id":"ci_3eb573ec5e46e3c0f47022a1c0dc6d6a39a087046bc3c5b31b8bfa54ef9c3848","title":"Steel Column","path":"/ideCAD/steel-column","children":[{"id":"ci_c94794fb5f7881e7d35184a34dc86a6a56bd05c446f90191f1a7bf6e4677f135","title":"Steel Column Settings","path":"/ideCAD/steel-column-settings","children":[]},{"id":"ci_a9822ff922fbec8c670fe9e2939d72e643042884bb27dcdf0a62f1742bf0127b","title":"Creating Steel Column","path":"/ideCAD/creating-steel-column","children":[]},{"id":"ci_c86dfc4b369acfb00aa3e1ebcbda557a650eeb93216c493c1114e0abe18c3719","title":"Creating a Steel Column 2 Points","path":"/ideCAD/creating-a-steel-column-2-points","children":[]}]},{"id":"ci_a903b3452090452287ae0e07a69ec3297124674b2c43c415a9d38a3d8f9589e6","title":"Steel Beam","path":"/ideCAD/steel-beam","children":[{"id":"ci_b39d46d2f556f5148aa55b130f5d81844e0bbc319ae2e1162d5f63cb964bd2d7","title":"Steel Beam Settings","path":"/ideCAD/steel-beam-settings","children":[]},{"id":"ci_1f604e94eb57a2f05d9aed8070668a865ba168c7955ab9284d62bc152b47a379","title":"Creating Steel Beam","path":"/ideCAD/creating-steel-beam","children":[]}]},{"id":"ci_be175d4f8376b9809762beec4f07576f6b9028feedfd972d0cad28a7f52126b4","title":"Secondary Steel Beam","path":"/ideCAD/secondary-steel-beam","children":[{"id":"ci_b38e7e1d61af3a7b781193bf17a983d5e7186e040d782b083ae565e476e60855","title":"Secondary Beam Settings","path":"/ideCAD/secondary-beam-settings","children":[]},{"id":"ci_8d0b23e13969342209e269629ef73ba2a8fe8c1ab6985cc2e27dad8e4777dcb4","title":"Creating a Secondary Steel Beams","path":"/ideCAD/creating-a-secondary-steel-beams","children":[]},{"id":"ci_b23fa18aae980a83c843cb06508cd2d4222c9cc004c7d78367b17cd0867f12e0","title":"Single Secondary Steel Beam Settings","path":"/ideCAD/single-secondary-steel-beam-settings","children":[]},{"id":"ci_9631f3eea704a560e3bbe09e00485c2305bc971cb9af4b8c57971a11b0365424","title":"Creating a Single Secondary Steel Beam","path":"/ideCAD/creating-a-single-secondary-steel-beam","children":[]}]},{"id":"ci_12d3d494caea1f3b040b805ac4fe7843c07a0f53b1028e70092ffcb7e8145994","title":"Steel Purlin","path":"/ideCAD/steel-purlin","children":[{"id":"ci_2f5f02b8b23d3dbd82b13cace1be274feda9b0738e3cdb047dea012ef5acca79","title":"Steel Purlin Settings","path":"/ideCAD/steel-purlin-settings","children":[]},{"id":"ci_49236f049e99ed4dc33383b42d983f70b08254f56cc5c5f50c8156969b5aa225","title":"Creating Steel Purlin","path":"/ideCAD/creating-steel-purlin","children":[]},{"id":"ci_08d0576954ecf956fe9e731bbae5d246bf9cef4733beab575b66a23bceafc24f","title":"Steel Tie Settings","path":"/ideCAD/steel-tie-settings","children":[]},{"id":"ci_20b6222e6d84eefb355b13cbf1da4758d6e2b2e4263cfe6a88449b80baa694f4","title":"Creating a Steel Tie","path":"/ideCAD/creating-a-steel-tie","children":[]},{"id":"ci_01983db4baafb093b0404bf0209df98930b0a562897a79c61b77c00895b6e36f","title":"Single Purlin Settings","path":"/ideCAD/single-purlin-settings","children":[]},{"id":"ci_5ab48da527c6185c9b61e20c687a8e0644651fd23f7417c561fce4931a773e79","title":"Creating a Single Purlin","path":"/ideCAD/creating-a-single-purlin","children":[]},{"id":"ci_59a77042c2e8f6c590a6fe222703d8d81eeeccf3d58275667b4dd3fd3c8dd090","title":"Space Purlin Settings","path":"/ideCAD/space-purlin-settings","children":[]},{"id":"ci_4a7a41da99503f4ca749b717aea67379e6ef47c1a67663be309bb36fa907436a","title":"Creating a Space Purlin","path":"/ideCAD/creating-a-space-purlin","children":[]},{"id":"ci_ae4623f174c67a98433d3d71635ec512ee69e99a6ac1ac8a6c3cab549d985357","title":"Steel Joist Settings","path":"/ideCAD/r-purlin-settings","children":[]},{"id":"ci_5f0a568cb24d191f5c01c27000e22c50fe400f9497c2b9cf0ef4b89ec9657417","title":"Creating a Steel Joist","path":"/ideCAD/creating-a-r-purlin","children":[]},{"id":"ci_7c878d439e9762a664a75ca08cf08e248b6e10766d0c4974c701ff104a8207f4","title":"Selecting Analysis Parts","path":"/ideCAD/selecting-analysis-parts","children":[]},{"id":"ci_0fa18a3eba2f481510f3c7ef5a51bfadf4dbafb0c4dcee932c0c4119869e4208","title":"Divide-Combine All Intersections","path":"/ideCAD/divide-combine-all-intersections","children":[]},{"id":"ci_8d1f4abab76b92d06c435c57900b3f7e0a6200d32a63fca60688c8701d45fde0","title":"Divide-Combine Single Intersections","path":"/ideCAD/divide-combine-single-intersections","children":[]}]},{"id":"ci_316f613c6a2feffdbe1c6e9af5bc5803fadde2f73c57013c1f15521b0a274cb2","title":"Sag Rod","path":"/ideCAD/sag-rod","children":[{"id":"ci_6363d620bc4728c5e361d6ae5542721bb3cddc1e9dedd615548e6e2a3a55efb2","title":"Sagrod Settings","path":"/ideCAD/sagrod-settings","children":[]},{"id":"ci_2c19d3eb6ed4a11022a27c5f0cbcfd4793ca20d55a475c685e42d3e558351c4c","title":"Creating a Sagrod on Purlin Group","path":"/ideCAD/creating-a-sagrod-on-purlin-group","children":[]},{"id":"ci_2bb829b8b78e665f9a3b8ee1b04b81e773a48e0529c80d911d7fbd90d4f97f59","title":"Creating a Sagrod on Single Purlins","path":"/ideCAD/creating-a-sagrod-on-single-purlins","children":[]},{"id":"ci_6cbc231f9f6a4b475f0b5e1d9a37199f687bc1060a64e74d47a6154cbb5a1957","title":"Creating a Sagrod for Roof Purlins","path":"/ideCAD/creating-a-sagrod-for-roof-purlins","children":[]}]},{"id":"ci_fd76bf613b07b125ef4d98aeb3a360102e97a850f8fc458a88957d8f0e7f2f65","title":"Steel Brace","path":"/ideCAD/steel-brace","children":[{"id":"ci_22a033b68e36641bbe407904808f40b161aff41cfd887678c3eb3cc06ae69516","title":"Steel Brace Settings","path":"/ideCAD/steel-brace-settings","children":[]},{"id":"ci_ac061e66221d4cb65affb5aa3858070dbd3ebe25558e6d7f5e369b22a31d3a68","title":"Creating Steel Brace","path":"/ideCAD/creating-steel-brace","children":[]},{"id":"ci_1cccae1c3f05dae45e2044fa83dd16f98e7ed3582beae01b99b72b0033bd77e9","title":"Creating Steel Brace Multiple Elements","path":"/ideCAD/creating-steel-brace-multiple-elements","children":[]},{"id":"ci_9dbf457fba2532816ac9d0caa64e5b135fcc519e78c9fb61801efb5c57ed8c39","title":"Single Steel Brace Settings","path":"/ideCAD/single-steel-brace-settings","children":[]},{"id":"ci_edb242f1fa34efcf32c69b8bf511606f0547a3db8dfe911e28cfdb0c802c46ce","title":"Creating a Single Steel Brace","path":"/ideCAD/creating-a-single-steel-brace","children":[]}]},{"id":"ci_d7b81f893544b2b6485e07cc3e7919837a6630412578de9a6f6089affc5213f3","title":"Truss","path":"/ideCAD/truss","children":[{"id":"ci_b0d241df4a035a99cc3507f4d229ceb60960d3fa1360a930889a77a356966a56","title":"Truss Settings","path":"/ideCAD/truss-settings","children":[{"id":"ci_54d3519da6f078bf5d55859fa1d535ea342999a98c0def81ef48077b05107550","title":"Setting Truss Pattern and Count","path":"/ideCAD/setting-truss-pattern-and-count","children":[]},{"id":"ci_00d6ca5f022d2edeef93340cefd78cf53783057def78104e57ea45474d903e42","title":"Setting Form of Header and Footer","path":"/ideCAD/setting-form-of-header-and-footer","children":[]},{"id":"ci_ca0f367f8359d00d1d932021f0da77b9c9765e9ad4f3836c27594b8b242cceef","title":"Setting Elevations and Heights of Truss","path":"/ideCAD/setting-elevations-and-heights-of-truss","children":[]},{"id":"ci_dadff36a25ff99ebe7447a9a2e389b4478bcd2d8d7b6e8bda0c8691a456157dd","title":"Setting Length and Alignment","path":"/ideCAD/setting-length-and-alignment","children":[]},{"id":"ci_7c1a86612fb0d01991c687b33675804c962a634cecd1a8c0116176da87b9cb1f","title":"Editing Footer and Adding Additional Elements","path":"/ideCAD/editing-footer-and-adding-additional-elements","children":[]},{"id":"ci_3f414a3eb204fae69c275934071de3a59fb006bc446194e288ccd3ef13b1440e","title":"Adding Console and Groove Distance to the Truss","path":"/ideCAD/adding-console-and-groove-distance-to-the-truss","children":[]},{"id":"ci_842b45481379d068978d88088f918fceeb82007e0a1e7be6befa860c721a77b3","title":"Editing Last Dioganal and Mid Vertical Element","path":"/ideCAD/editing-last-dioganal-and-mid-vertical-element","children":[]},{"id":"ci_ecb00480e1661d55c7de49bec35fc9aa7aeb118c9e6e0047d264f84084bb26c1","title":"Setting the Profile of Truss Elements","path":"/ideCAD/setting-the-profile-of-truss-elements","children":[]},{"id":"ci_43b139e6a9cdf38f74abff5c7b37dd252177139be035ff3dec4c7a621957ef64","title":"Editing Truss Drawing Properties","path":"/ideCAD/editing-truss-drawing-properties","children":[]},{"id":"ci_f269d0336e0d68dd8093278b22c388bd66bf1d85f9ba26cae334d2d027b73f68","title":"Modifying Truss Elements","path":"/ideCAD/modifying-truss-elements","children":[]}]},{"id":"ci_7ff6e774fc803137278e6b7a4da87d673855d2c077e4531d31538c83fbebe224","title":"Creating a Truss","path":"/ideCAD/creating-a-truss","children":[]},{"id":"ci_9aa8bfddf036f944d1f95dd4553fb840cbd2f9c9d0cf578118c56f399379ef04","title":"Prepared Truss Type","path":"/ideCAD/prepared-truss-type","children":[{"id":"ci_85d196f7ddeb5a017dc76e56764be8bfe1e2efdea7263930bef79dfdced6cb0f","title":"Trapezoid Type 1 Truss","path":"/ideCAD/trapezoid-type-1-truss","children":[]},{"id":"ci_a8e397fc18fbb563e01508a6f421ae47fd9d69204db1b1b7b4c1c0bb031e46da","title":"Trapezoid Type 2 Truss","path":"/ideCAD/trapezoid-type-2-truss","children":[]},{"id":"ci_953461921eb9b73b4b2e456e534eb51b8b03e61a560e87a179b0a915db636061","title":"Trapezoid Sloping Left Truss","path":"/ideCAD/trapezoid-sloping-left-truss","children":[]},{"id":"ci_91b2cc9d04e48f64cd7f5a049bd65716efdc111e2b741794bcef3bde5707d760","title":"Trapezoid Sloping Right Truss","path":"/ideCAD/trapezoid-sloping-right-truss","children":[]},{"id":"ci_da0fbace2a0f0da970c0fffe15bef715257bf934df7d7c5698534bdfd1af3856","title":"Triangular Symmetric Truss","path":"/ideCAD/triangular-symmetric-truss","children":[]},{"id":"ci_513af6bad60b252907cc7dd1c02305369a5122e28b5220610bf482b2754984fe","title":"Triangular Asymmetric Truss","path":"/ideCAD/triangular-asymmetric-truss","children":[]},{"id":"ci_32598705ec9938f7c7c0197b04ec5159a660e796c75a826fd282b463041d3974","title":"Triangular Sloping Left Truss","path":"/ideCAD/triangular-sloping-left-truss","children":[]},{"id":"ci_571c63cd17872a0d2b0c035cb4ae736844195b587b27ae782620040b58653e10","title":"Triangular Sloping Right Truss","path":"/ideCAD/triangular-sloping-right-truss","children":[]},{"id":"ci_ed389347b17eb6e0b6dda12910ccbbef5b2e09232b602a8fb6813949a974d270","title":"Trapezoid Sloping Symmetric Truss","path":"/ideCAD/trapezoid-sloping-symmetric-truss","children":[]},{"id":"ci_8b2848d2110d69da3cff3655a2b2b9b525f19cd28e18ed4ada9eea2c156ae6dc","title":"Trapezoid Sloping Asymmetric Truss","path":"/ideCAD/trapezoid-sloping-asymmetric-truss","children":[]},{"id":"ci_95685277552f9d1febd80caf00c4915fb2e0c1c4fb7122309187569ab1be785f","title":"Flat Truss","path":"/ideCAD/flat-truss","children":[]},{"id":"ci_d658eb2261aa6ff4fdf1a11800688c4dfb79bb84dbbf28a33bdd7c0595955834","title":"Sloping Flat Truss","path":"/ideCAD/sloping-flat-truss","children":[]},{"id":"ci_c3889449f91277367f2d2716ed67cf2eb4ebb2b2601a467d3d1cbedfc900d36c","title":"Trapezoid Vault Truss","path":"/ideCAD/trapezoid-vault-truss","children":[]},{"id":"ci_0dc5a612f6019936f455d9eb53fd33a9a03949904bdc8aa1de7457fd7e3ebf35","title":"Vault Truss","path":"/ideCAD/vault-truss","children":[]},{"id":"ci_04b1f8a24c34a9b3a7a7944b51c3ec6720491f0f53cb222f5a491685d52093ea","title":"Double Vault Truss","path":"/ideCAD/double-vault-truss","children":[]},{"id":"ci_099272dade7ec3b600df461d345d3a27c99f5d227cd940a84fa77d1ba73bd30d","title":"Sloping Vault Truss","path":"/ideCAD/sloping-vault-truss","children":[]}]}]},{"id":"ci_7b7e00a34fef4b2c08dba0979ecd3af75ae7d928620bb8ded02411ee33b6f6c0","title":"Steel Slab","path":"/ideCAD/steel-slab","children":[{"id":"ci_68a3af836e02252133639bc307d9f1bee22355c9cb249756c1fbb44ecdb380a7","title":"Composite Deck Slab Settings","path":"/ideCAD/composite-deck-slab-settings","children":[]},{"id":"ci_99b7702b341c43a048081123745ed63cdc5a61fe56de856a133f8da8c9d23925","title":"Creating a Composite Deck Slab","path":"/ideCAD/creating-a-composite-deck-slab","children":[]},{"id":"ci_72e537e4da7ff6e7a36bd5ccdb8a6326412ca3a1b32f87ac899b68e1b2cd013f","title":"Composite Solid Slab Settings","path":"/ideCAD/composite-solid-slab-settings","children":[]},{"id":"ci_f1009a0c2c81baa86f22a0a305d0ac409be208fdb9a33e3e9f82bbba5ff3cb4b","title":"Creating a Composite Solid Slab","path":"/ideCAD/creating-a-composite-solid-slab","children":[]},{"id":"ci_b9ece12d2bc668629adb538e0c27f777f4f4fcadb5fe266424fa3a465324189a","title":"Concrete Slab Settings","path":"/ideCAD/concrete-slab-settings","children":[]},{"id":"ci_5dbb3c31be9f7cc05c5d9830ac3b6eae1caa395eddc6cf2f1f54a4b58badbfae","title":"Creating a Concrete Slab","path":"/ideCAD/creating-a-concrete-slab","children":[]},{"id":"ci_cf4f8f6c6ba01f19ec7c9c855e85a89289cbf472fb13b00558ea3563ab88cff5","title":"Metal Slab Settings","path":"/ideCAD/metal-slab-settings","children":[]},{"id":"ci_c3adb74a6088efc02f0054fc2a2d5efe366d537903f150c02be66e6ab639a0d6","title":"Creating a Metal Slab","path":"/ideCAD/creating-a-metal-slab","children":[]},{"id":"ci_fe9253e32f2e0aaab16df36289f476a7809430b3625fa68564780d217cf0886a","title":"Steel Slab Edge","path":"/ideCAD/steel-slab-edge","children":[]},{"id":"ci_34664fdfc8a9f004c309533a1af64ebe387f9340282844ae9468df59087f4aa4","title":"Editing Slab Edge","path":"/ideCAD/editing-slab-edge","children":[]},{"id":"ci_01bc066de9ff25daabadd07ba940dc8b93d549a7ade88836cd88a900916dcf84","title":"Creating a Steel Slab Hole","path":"/ideCAD/creating-a-steel-slab-hole","children":[]},{"id":"ci_9fee5c241604d159f0306650ff4438886fb3ab3c83cf89722a41047f6134e18f","title":"Delete Slab Hole","path":"/ideCAD/delete-slab-hole","children":[]}]},{"id":"ci_466ee799cb2f9a296329deb76316ced8d74e1190edede083e131b81caf8cf006","title":"Sheeting","path":"/ideCAD/sheeting","children":[{"id":"ci_03205f360b142bec2005f6e825c8e47d7f63674154248f758d5b8b69154afb5c","title":"Sheeting Settings","path":"/ideCAD/sheeting-settings","children":[]},{"id":"ci_ee1871c1c286c09cb942493f201c74309b933ae63d33f6dd4fff4748814892d4","title":"Creating a Purlin Sheeting","path":"/ideCAD/creating-a-purlin-sheeting","children":[]},{"id":"ci_43d65aa24a6086ff320d13c9ab23770bfae822802eaee53cb2e70ff87b5b9a11","title":"Creating a Polygonal Sheeting","path":"/ideCAD/creating-a-polygonal-sheeting","children":[]},{"id":"ci_be7e79456b6a19f9909481d6ad39a17c54267d56a83feee3fbcc30d817d51c77","title":"Creating a Sheeting Between Elements","path":"/ideCAD/creating-a-sheeting-between-elements","children":[]}]},{"id":"ci_066d9b96b874525d89599a012818f9dcbca039f4268833b17de6db298c2c82d6","title":"Space Truss","path":"/ideCAD/space-truss","children":[{"id":"ci_4cb25aaf642cabb39d1918d285c08630686451bc013309a1dfa8d113968a99f4","title":"Space Truss Settings","path":"/ideCAD/space-truss-settings","children":[]},{"id":"ci_1ddfabd99f59d78d3665c5ef47691d6a73aa29ccebcdd6ce3eea41495283f2df","title":"Creating a Space Truss","path":"/ideCAD/creating-a-space-truss","children":[]},{"id":"ci_bbb15d60b831d9dc95e0791366561d8d8bb049b1c12be61cb78d1fa07054fc2d","title":"Remove a Nodule","path":"/ideCAD/remove-a-nodule","children":[]}]},{"id":"ci_9761ebe3823763ecc1437e2fe63be2567412012159c7b016edfca80ab852d108","title":"Crane","path":"/ideCAD/crane","children":[{"id":"ci_7bf8e95c8d9860671d7fc6f549b8bdc69db2f78a03b73fb7ffd82cd20bff0738","title":"Crane Settings","path":"/ideCAD/crane-settings","children":[]},{"id":"ci_20f5df59a57bb10994f765cf40b1ccda0df79fe83c939d3ed45250f804e3ac09","title":"Creating a Crane","path":"/ideCAD/creating-a-crane","children":[]}]},{"id":"ci_35f182bf64cf61557a63443645c304655efa32c7f18a575e940f245a18ca6925","title":"Steel Connection Modeling","path":"/ideCAD/steel-connection-modeling","children":[{"id":"ci_4b4f7fc1cc16d109573879c5af47914b4c847d18af31d25877f87bf03b7b13c3","title":"Weld Electrodes","path":"/ideCAD/weld-electrodes","children":[]},{"id":"ci_bc318abe2be65c6a6b69a4946152833965cc1e322ce1b8a4f4fe7c03ab91a13d","title":"Connections Overview","path":"/ideCAD/connections-overview","children":[]},{"id":"ci_9d7a2b4283d5529a91538f8b57631517b49ddb4e29c3f6fa01e72c30ee9c3fb9","title":"Hole and Bolt Parameters","path":"/ideCAD/hole-and-bolt-parameters","children":[]},{"id":"ci_3bc8e21b36b6e44c20a8bdc492b2c0e714bce5b84df2415566bf68c3f6f3f5fe","title":"Draw in Fast Mode (Connections)","path":"/ideCAD/draw-in-fast-mode-connections","children":[]},{"id":"ci_3559f309e6e54ab4f4ccdf70380f546c2c2cf9633a19f5e20af350b7d5ad07d8","title":"Designed Connections","path":"/ideCAD/designed-connections","children":[{"id":"ci_481ba2d2c97059c02c833c9d80c2c3d4a5ee677d89dfbd0410020553b40c0831","title":"Defining Shear Connections","path":"/ideCAD/defining-shear-connections","children":[{"id":"ci_796f6389354a35f14f3d285ad080919595333f7678380330c800e35eeb0810c0","title":"Defining Double Angle Connection","path":"/ideCAD/defining-double-angle-connection","children":[]},{"id":"ci_2e147e272dd735daf4c43686c410cd4beed39c68560c63a5a3f67e99ae80a404","title":"Defining a Single Plate Connection","path":"/ideCAD/defining-a-single-plate-connection","children":[]},{"id":"ci_a8bb4995891a0c3abc6db55ac38934ac80a046bf9600b0ce9aa724850e75d7d7","title":"Defining a Unstiffened Seated Connection","path":"/ideCAD/defining-a-unstiffened-seated-connection","children":[]},{"id":"ci_8a988930ecc9347f6c0e648f9c981e80cbce66c922d8300ebdb5fd45f05e4245","title":"Defining a End Plate Shear Connection","path":"/ideCAD/defining-a-end-plate-shear-connection","children":[]},{"id":"ci_f2c79bc02c2790147c07656f1358ef27ecbc8f53cc9e395d9864f51f007acf27","title":"Defining a Single Angle Connection","path":"/ideCAD/defining-a-single-angle-connection","children":[]},{"id":"ci_84f552923a5f0df3a355f14ed0248b53011806cdc13ade3156a1fd6a94c77383","title":"Defining a T Plate Connection","path":"/ideCAD/defining-a-t-plate-connection","children":[]}]},{"id":"ci_49d297dcb9afcd0aec8fd75599adfd97244f078be4053fe53323232d2685f653","title":"Defining Moment Resisting Connections","path":"/ideCAD/defining-moment-resisting-connections","children":[{"id":"ci_9951b3cf4648247ca561d2d460da6db24ba75a1aeffe5359600ede5ad7b648ec","title":"Defining a 4 Bolts Unstiffened End Plate Connection","path":"/ideCAD/defining-a-4-bolts-unstiffened-end-plate-connectio","children":[]},{"id":"ci_a2569f321de59de9fd86462524b2e2b754eab111f365835fe47c7bc0644d9cb5","title":"Defining a 4 Bolts Stiffened End Plate Connection","path":"/ideCAD/defining-a-4-bolts-stiffened-end-plate-connection","children":[]},{"id":"ci_d81fa7b56c1cd1be74e7dc836331ebcc63d2773c5fa20fc9aa61d4e5c0919638","title":"Defining a 8 Bolts Stiffened End Plate Connection","path":"/ideCAD/defining-a-8-bolts-stiffened-end-plate-connection","children":[]},{"id":"ci_40a1e501c11d359a5a43ef2db2cdda860cb4197b546cfee289e02dc332471324","title":"Defining a Bolted Flange Plate Connection","path":"/ideCAD/defining-a-bolted-flange-plate-connection","children":[]},{"id":"ci_544cf835b3e2f8cbc3351a9c49aae7200ba72e6a88c8c0d0f7bc501a76e27381","title":"Defining a Welded Web Connection","path":"/ideCAD/defining-a-welded-web-connection","children":[]},{"id":"ci_dc598151b95831e9ea1c680b5938fcc504edb870084d6d67e4388325baa8564b","title":"Defining a Welded Flange Plate Connection","path":"/ideCAD/defining-a-welded-flange-plate-connection","children":[]}]},{"id":"ci_c78ff7d53f91f194ce9068446eabb74f6ea080369135a99e4fb996ad6cad19ef","title":"Defining Splice Connections","path":"/ideCAD/defining-splice-connections","children":[{"id":"ci_0f124383ce6b5e547e13d5c76f21e670acf1640446e0c97f4aa9ff4ebd82a0e4","title":"Defining a Splice Connection","path":"/ideCAD/defining-a-splice-connection","children":[]},{"id":"ci_b13d7af47369c1d859999263c27b08171200f90cab48a3f2e4654ba294c44dc0","title":"Defining a Joining Plates Connection","path":"/ideCAD/defining-a-joining-plates-connection","children":[]}]},{"id":"ci_e2be66e024d8d096422d0b524352be294f77adb347b8363f72f40ae78f888895","title":"Defining Brace Connections","path":"/ideCAD/defining-brace-connections","children":[{"id":"ci_ea2289a0d7e6e811e30d747930adcaae721eea7da466eed3a1594a9e288e8ecc","title":"Defining a Brace Center Connection","path":"/ideCAD/defining-a-brace-center-connection","children":[]},{"id":"ci_f21d4e0d5c228457ddbc4f9686eccbe9ca383e4cfc805982a57db0a5392127d3","title":"Defining a Brace Corner Connection","path":"/ideCAD/defining-a-brace-corner-connection","children":[]}]},{"id":"ci_9be2a9ca06dc284caf59a2ebbd722ab2260dab7c23a1d751642c3d4da354d300","title":"Defining Foundation Connections","path":"/ideCAD/defining-foundation-connections","children":[{"id":"ci_97ed7b9db40a30b26f73fb8b395801f42c2be475e42036cfa6333955f386fdf8","title":"Defining a Column-Foundation Connection (Stiffened Baseplate)","path":"/ideCAD/defining-a-column-foundation-connection-stiffened-","children":[]}]}]},{"id":"ci_bd5cbc6e45f7879352f8e64931ad1776dfd57cc7dde233954d1f8719c1fd555b","title":"Experimentals Connections","path":"/ideCAD/experimentals-connections","children":[{"id":"ci_1789192063faa07263d1938fa928107548e9cbe7ddb224711a1bdc9a782e6e52","title":"Defining a Haunch Connection","path":"/ideCAD/defining-a-haunch-connection","children":[]},{"id":"ci_ca67376e1ce580b74e04e3df6f9b45b43b80b621c8f3d4241a81a6b699a3b701","title":"Defining a Flange Plate Connection","path":"/ideCAD/defining-a-flange-plate-connection","children":[]},{"id":"ci_60ca2af30ac0ef57e57ce5cd74b8cf43e6c278f643ff6afecd5c224f6ee3e8ce","title":"Defining a Stiffened Shear Plate Connection","path":"/ideCAD/defining-a-stiffened-shear-plate-connection","children":[]},{"id":"ci_850c07a033b92bbaff9966703bf5cc75b32f53c9f22acc35500a09db01991cc0","title":"Defining a Stiffened End Plate Connection","path":"/ideCAD/defining-a-stiffened-end-plate-connection","children":[]},{"id":"ci_4b835426b528831a167692b5f231f509784c2b5247724e8d1914d6bcdfba7a1d","title":"Eaves Haunch Connection","path":"/ideCAD/eaves-haunch-connection","children":[]},{"id":"ci_837c523294ebac31319562769bcb775ccd4e9c79f82ef4432d375bc6c9177e2e","title":"Defining a Multi Stiffener Plate Connection","path":"/ideCAD/defining-a-multi-stiffener-plate-connection","children":[]},{"id":"ci_e9f9255d3ec16885103f6ec2df86532b0f9c8f4bbb7efa6ad1d3ef69b6cd2eb5","title":"Defining a Quad Stiffener Plate","path":"/ideCAD/defining-a-quad-stiffener-plate","children":[]},{"id":"ci_7ef040d410f990b85bff843fee0b39427a5587a527f806c7386f98fe3b2537d3","title":"Defining a Multi Stiffener Plate (Horizontal) Connection","path":"/ideCAD/defining-a-multi-stiffener-plate-horizontal-connec","children":[]},{"id":"ci_eef10ad59dc7e63c1f4a45da26e89f9804e10dfa8dfeea1abbaf3d51bcc4c2e5","title":"Defining a Welded Box/Tube Connection","path":"/ideCAD/defining-a-welded-box-tube-connection","children":[]},{"id":"ci_fb67dad8c1465d27640ed953ba1e1beabdf99729808807fbf88a7a51feb45db9","title":"Defining a Seating Support Connection","path":"/ideCAD/defining-a-seating-support-connection","children":[]},{"id":"ci_6dcd6cc72925392af7dbb480af9f50d6ab6f27c8289a43b214a54cb116abdf49","title":"Defining a Stub","path":"/ideCAD/defining-a-stub","children":[]},{"id":"ci_d0f25863cb761452d8693540c6a2f3e4e1cfc6860cdfcaffd6a88144b12b3817","title":"Defining a Notched Seating Connection","path":"/ideCAD/defining-a-notched-seating-connection","children":[]},{"id":"ci_3486588e9e9243334e3851b2dee64369f90794f3c416a689165ce767ef4700ac","title":"Defining a Spacer Plate Connection","path":"/ideCAD/defining-a-spacer-plate-connection","children":[]},{"id":"ci_22cae2246dea7e6a65cccebe33935eeca855d0461aec90f0d68f28cbf13f4055","title":"Defining a Wind Connection","path":"/ideCAD/defining-a-wind-connection","children":[]},{"id":"ci_6f4ba96b42e3fbc8d7ff2843b9dd97891c369bf3e814f2319989a8450c7bf3b8","title":"Defining a Stay Connection","path":"/ideCAD/defining-a-stay-connection","children":[]},{"id":"ci_86f016cbc41a3186fcbd07bb57a4fbc9571af31ecdffa331acc021cb695722f7","title":"Defining a Stay Connection (Secondary Beam)","path":"/ideCAD/defining-a-stay-connection-secondary-beam","children":[]},{"id":"ci_d3a99b759075ec40ea3121472150bbda03a7e934ca6a27273ecf436beca5ac85","title":"Defining a Box/Tube End Plate Connection","path":"/ideCAD/defining-a-box-tube-end-plate-connection","children":[]},{"id":"ci_86135158c90a27f925a18a3e3c216dd53dfd921a141d6d4e4d1689a39db49380","title":"Defining a Box/Tube Splice Connection","path":"/ideCAD/defining-a-box-tube-splice-connection","children":[]},{"id":"ci_3b5afac16ad1731dd4918a0f055f6b989785beeee34cf7e4b3799b98d57581f5","title":"Defining a Continuous Beam Connection","path":"/ideCAD/defining-a-continuous-beam-connection","children":[]},{"id":"ci_047cf5317273cac80352fb6b657c631c45710dc65b61ca3e65a1bf97ba9bdc29","title":"Defining a Column-Column End Plate Splice Connection","path":"/ideCAD/defining-a-column-column-end-plate-splice-connecti","children":[]},{"id":"ci_8c2a93c4404d55c4d34bb6d61e34a47acebc69ad383b4e3b3f2c12da320e4692","title":"Defining a Seating Weld Connection","path":"/ideCAD/defining-a-seating-weld-connection","children":[]},{"id":"ci_83c003883007de66fc93886e6d0cddee3ec3dde1c55ef70a20c3ee7a0cf0b2b5","title":"Defining a Single Plate Seating Connection","path":"/ideCAD/defining-a-single-plate-seating-connection","children":[]},{"id":"ci_ffd524bc58bee32e72f25a1778b0fb396363ea07227db3334e6d6ca251d53997","title":"Defining a Double Plate Seating Connection","path":"/ideCAD/defining-a-double-plate-seating-connection","children":[]},{"id":"ci_422456e08222b29181e34eda9c6065f400d12ab6e56a5a0cf3f394de8a1637ab","title":"Defining a Box/Tube Seating Connection","path":"/ideCAD/defining-a-box-tube-seating-connection","children":[]},{"id":"ci_ec59e14a184bdfafbdba108058341e575949896e3f7542ac563cca32d713435c","title":"Defining a Truss Connection","path":"/ideCAD/defining-a-truss-connection","children":[]},{"id":"ci_8762af506e52f451fd18cd11681e3a7e541cacfdd6c03a2a84fb91cb6aa5be20","title":"Defining a Apex Type Connection","path":"/ideCAD/defining-a-apex-type-connection","children":[]},{"id":"ci_af868ca661678ae151a458598a1aae4c5934b00563dcc183596644dbc87d2b22","title":"Defining a Purlin Connection","path":"/ideCAD/defining-a-purlin-connection","children":[]},{"id":"ci_6a6eab3d5dfce3514deb9308631936c530edee2e7db6ae37c2c00f49b1540366","title":"Defining a Girt Connection","path":"/ideCAD/defining-a-girt-connection","children":[]},{"id":"ci_947da57c8bc446e8a0ae6bec4945135eb8f98ffdbc98176dc305e061f3eafe9e","title":"Defining a Column-Column Connection (Built Up Column)","path":"/ideCAD/defining-a-column-column-connection-built-up-colum","children":[]},{"id":"ci_e104b32a9bae64c0abefc8248df1f27d727de99fc66540d316d4dffdf8c4a66f","title":"Defining a Simple Base Plate","path":"/ideCAD/defining-a-simple-base-plate","children":[]},{"id":"ci_af02ae6a7a7c1b224fe3784f589b3e5ee0d88faa25bbad44bd1cf24f02a2e7af","title":"Defining a Rigid on Strong Axis Base Plate","path":"/ideCAD/defining-a-rigid-on-strong-axis-base-plate","children":[]},{"id":"ci_76c6bbc8f4cecd86c5f5287edd84aafe98f5a196796c2c25573a5a889c2c6423","title":"Defining a Rigid on Both Axis Base Plate","path":"/ideCAD/defining-a-rigid-on-both-axis-base-plate","children":[]},{"id":"ci_f8c168ce69698b80841ebf2cf28f436fe954fd8ca02ee247bdeae2accd19cd0d","title":"Defining a Tube Base Plate","path":"/ideCAD/defining-a-tube-base-plate","children":[]},{"id":"ci_40a2b27a8314627661f430d82e245f8fdd8c073e8aa419c97db8fd8dd8e0adf9","title":"Defining a Round Plate Tube Base Plate","path":"/ideCAD/defining-a-round-plate-tube-base-plate","children":[]},{"id":"ci_414c586b3693fa8975450cba5c75d5cb79ac808233eaace5905d96a3b53a4435","title":"Defining a Welded Connection","path":"/ideCAD/defining-a-welded-connection","children":[]},{"id":"ci_62db7cbf2ecf391a7a1cdbdc1ff8acf23abee7beb10594497d0a0a3763010a45","title":"Defining a Box/Tube Cap Plate","path":"/ideCAD/defining-a-box-tube-cap-plate","children":[]},{"id":"ci_562c144abc3cc4bd89e8581fd3cefdfd84ed8ff8ee12e2abce6d06d4e87141fc","title":"Defining a Column-Beam Stiffened End Plate Connection","path":"/ideCAD/defining-a-column-beam-stiffened-end-plate-connect","children":[]},{"id":"ci_b1420b550aa3522053680b1aa70d1effc04e8eb7369f5eaff9380389d473d9cc","title":"Defining a End Plate Truss Connection","path":"/ideCAD/defining-a-end-plate-truss-connection","children":[]},{"id":"ci_40f31cd52de0c2e141b922404c761753b7c40a8fa88f6d526a849d292309fb68","title":"Defining End Plate Truss Connection For Box/Tube","path":"/ideCAD/defining-end-plate-truss-connection-for-box-tube","children":[]},{"id":"ci_f01dd7660e5f14c48d5a3c2d5d24e275f14bf63fac4fae8852ce1231e936ccae","title":"Defining a Seating Truss Connection","path":"/ideCAD/defining-a-seating-truss-connection","children":[]},{"id":"ci_a1aab408f279e94b53b8e7e511f25aba64835072bb78b55569fa3ce0e208cbcf","title":"Defining a Crane Connection","path":"/ideCAD/defining-a-crane-connection","children":[]}]}]},{"id":"ci_700aeebfab37df59b82b0533eb40d7ec7820a1d7ac6bee21cbced375c2a52b14","title":"Steel Stair Macro","path":"/ideCAD/steel-stair-macro","children":[{"id":"ci_2ca5bbd3aab98b126814e3010720133c69b6c4398218ae2ddf9c2b5a1c98f3c0","title":"Steel Stair Macro Settings","path":"/ideCAD/steel-stair-macro-settings","children":[]},{"id":"ci_1e9163cb10b70d1ea4f1bdb306a0db0b79bb3aa24101926083d36069a18267dc","title":"Creating a Steel Stair","path":"/ideCAD/creating-a-steel-stair","children":[]}]},{"id":"ci_063729b916c9f657005d375f3c376d7261bcc59aec7029c68662397eb8f51024","title":"Steel Hand Rail Macro","path":"/ideCAD/steel-hand-rail-macro","children":[{"id":"ci_53744dab8897b0e005a4406cf92badf0f29372d4ef4a6891ad9528166c958e15","title":"Steel Hand Rail Macro Settings","path":"/ideCAD/steel-hand-rail-macro-settings","children":[]},{"id":"ci_543a10074a4197efa0de10193acec95529ec8351382d16ee4fa4f3f3eb8a3b60","title":"Creating a Steel Hand Rail","path":"/ideCAD/creating-a-steel-hand-rail","children":[]},{"id":"ci_5a9e168f07ded4f587992ad09189fb97f56c606a7f366a9b564bcd3b47f0dbf2","title":"Creating a Steel Hand Rail on Line","path":"/ideCAD/creating-a-steel-hand-rail-on-line","children":[]},{"id":"ci_422a40e8b7b368f8ba4e1f0b4656135d20c54c8aaa5c497cf57c6a439448fe0a","title":"Creating a Steel Hand Rail on Arc","path":"/ideCAD/creating-a-steel-hand-rail-on-arc","children":[]}]},{"id":"ci_5e480c4f7fa74d11cb0610567ef9e7a94a0ece6330125217d48f84cd76cb6536","title":"Scaffolding Macro","path":"/ideCAD/scaffolding-macro","children":[{"id":"ci_f74b722133a3970540ed32e5f1f7ec13a528de0213e3dda84820054ffe02bb5e","title":"Working Principles","path":"/ideCAD/working-principles","children":[]},{"id":"ci_b4a4885ad4c9cd9e7b0562b9b158c0b9b2cdc3ef8cb5392158e123382c3e1180","title":"Adding/Deleting Partitions","path":"/ideCAD/adding-deleting-partitions","children":[]},{"id":"ci_7d992b778f75b6d89adf9d1f3db6a74b8bc3361a16cb0d6d239688e0188df04d","title":"Adding/Deleting Stories","path":"/ideCAD/adding-deleting-stories","children":[]},{"id":"ci_1cf484e46b85a9f3ff46408cb2b74dcd4a6915e39c5fae348dacc2c7ba1e1273","title":"Editing Height and Elevation Settings","path":"/ideCAD/editing-height-and-elevation-settings","children":[]},{"id":"ci_0c82414db2dca0b12ffcd312cee61877dd07a0b79e731c4bbeac57693099d5b7","title":"Editing Partition Format Settings","path":"/ideCAD/editing-partition-format-settings","children":[{"id":"ci_535bab4c8a12c0933faf5597ac8744a03b1f34b179c4849d891c7aabac6e7760","title":"Setting Partition Height","path":"/ideCAD/setting-partition-height","children":[]},{"id":"ci_801f064e8bd8412a272078c012172f449ae09d2e1b6ce7df8fb011326fecad22","title":"Setting Partition Width","path":"/ideCAD/setting-partition-width","children":[]},{"id":"ci_fb70d5ab7f394bda4eb0228407bad9bf446aaf41f78a3e05d9591d99efb1f520","title":"Setting Walk Way Width","path":"/ideCAD/setting-walk-way-width","children":[]},{"id":"ci_332b436dc56416a983e01e17bb3e5511e39ae9380122f93a2b911359325d6eec","title":"Setting Partition Length","path":"/ideCAD/setting-partition-length","children":[]},{"id":"ci_a6c683036b61dd66f153116b37cbacd4ce8e1d6b924f0abb3cf43a47efacf163","title":"Setting Footer Height","path":"/ideCAD/setting-footer-height","children":[]},{"id":"ci_8411313e3237d599bde7d490e3f1642cfe3ae108f295d9d32425f68469e8b251","title":"Setting Location of Beam","path":"/ideCAD/setting-location-of-beam","children":[]},{"id":"ci_aa14969bce4d5575fb8412d74952d82396873c193e267befe1f7422b1ec63306","title":"Setting Brace Corner Points","path":"/ideCAD/setting-brace-corner-points","children":[]}]},{"id":"ci_65e7f6534629b8a3beea1bfad269db816821de5f93214055c81fa05ff44e2743","title":"Scaffolding Element and Section Settings","path":"/ideCAD/scaffolding-element-and-section-settings","children":[{"id":"ci_dd6d32467af2912024ba7b233f60fbbadd1563ccf893406e197d120d318de639","title":"Scaffolding Column Settings","path":"/ideCAD/scaffolding-column-settings","children":[]},{"id":"ci_762bf18743b31dc880bdbeae63a350ccef6ef956f223d25bd0af4bdbc3b747ad","title":"Scaffolding Beam Settings","path":"/ideCAD/scaffolding-beam-settings","children":[]},{"id":"ci_b728360977ad92b9c7ea6e8bf52c3623e9b6796251b8d95a2e1ff186c7be17ab","title":"Scaffolding Single Brace Settings","path":"/ideCAD/scaffolding-single-brace-settings","children":[]},{"id":"ci_ce8d8d04f36dd6292dda5fd3a1092af0c50ee548c624c059e24f17ab612dbd88","title":"Scaffolding Slab Settings","path":"/ideCAD/scaffolding-slab-settings","children":[]},{"id":"ci_2ab0cd3f41909ad784dce7acefad1a01fd49d9d35ce01710dc32dc9331df06fb","title":"Scaffolding Walk Way Settings","path":"/ideCAD/scaffolding-walk-way-settings","children":[]},{"id":"ci_e278fee9bd97d7bc6707bd500a9d5006576187c16db8b060c6eb586a84a2ce93","title":"Scaffolding Footer Settings","path":"/ideCAD/scaffolding-footer-settings","children":[]}]},{"id":"ci_c7d9bbfd1720d85504927d8e71887af93f0779b2a8544c9282c51442936e68d7","title":"Editing Wind Settings","path":"/ideCAD/editing-wind-settings","children":[]},{"id":"ci_c45507ce14a3f50034ec485a34d8b5a6ddca8b2cff7663df9444c2c7d9149592","title":"Editing Anchor Length and Section","path":"/ideCAD/editing-anchor-length-and-section","children":[]},{"id":"ci_e1ef07300bebc99f494ca1ef07130b8e0bdf2ac51e9aef21f7ddba1a5c7e375b","title":"Determination of Anchor Layout","path":"/ideCAD/determination-of-anchor-layout","children":[]},{"id":"ci_34a6d4d74d3e8534f0007ca65590b0d36534af935442f6106a988b3dc61ec608","title":"Choosing the Brace Type","path":"/ideCAD/choosing-the-brace-type","children":[]},{"id":"ci_ef0faba2cb3691f52415ca233f54f5ab18a436b4dcaad6270fcfc0c252f4bffb","title":"Editing Scaffolding Banister","path":"/ideCAD/editing-scaffolding-banister","children":[]},{"id":"ci_bfad192f5b0166b69b1cdb76ae3861ef3c79435e81a5067592dd2c9026e56f57","title":"Editing Stair Settings","path":"/ideCAD/editing-stair-settings","children":[]},{"id":"ci_da0dfc5e65db44f7d0691aa9a28229211a684ed136d7b5474c7766905cab3979","title":"Creating a Scaffolding","path":"/ideCAD/creating-a-scaffolding","children":[]},{"id":"ci_6bdf355f9a36180e9480c4a0bd446c0a7f6a208c5203485c58f11035932a8c17","title":"Creating a Arc Scaffolding","path":"/ideCAD/creating-a-arc-scaffolding","children":[]},{"id":"ci_f5809dcb08233c69bf9013b912e83c878db616e3fe5c8c477392c48944087221","title":"Creating Scaffolding in Stepped Structures","path":"/ideCAD/creating-scaffolding-in-stepped-structures","children":[]},{"id":"ci_7bebc02f6cf05904029a6eef78c8fd55f88bf293419609e1f14fb5f2aa16d28d","title":"Disassembling a Scaffolding Macro","path":"/ideCAD/disassembling-a-scaffolding-macro","children":[]}]},{"id":"ci_ded01a6b23112d4385546100ba66ba9d2267a8853f8afecba5049697c4486757","title":"Industrial Building Modeling","path":"/ideCAD/industrial-building-modeling","children":[{"id":"ci_152bdb37e610376189cb830d45997083d488550af4b2393eeebc4a6bd03d3c8d","title":"Industrial Building Structures Overview","path":"/ideCAD/overview-1","children":[{"id":"ci_e6f2f29beb9b07a27df2e75d5646b4937aee74ab04666458c5b407504602cc35","title":"Hall Macro Working Principles","path":"/ideCAD/hall-macro-working-principles","children":[]},{"id":"ci_756d12ac8c7c0c197675ae933d66b79799ba8f4dcf71fe488fd02545601a44ad","title":"Hall Creation","path":"/ideCAD/hall-creation","children":[]},{"id":"ci_6a5843aa42343a2ccf4cedb2b2c781775866a64b5344425bd4bad5e6bc1e2f7a","title":"Making Story Settings","path":"/ideCAD/making-story-settings","children":[]}]},{"id":"ci_7f209b5ac41e75563cf842269b67440dcb9bb4d0db45232b6583f9884bc6f1d7","title":"Hall and Partition Editing","path":"/ideCAD/hall-and-partition-editing","children":[{"id":"ci_a858121dc1b4c6c303261e48b9b51af3e30308e4579cf5d0b4e980e924abc205","title":"Add Hall Left","path":"/ideCAD/add-hall-left","children":[]},{"id":"ci_71e2b473a2e33efcaeb03f4af8b2feb18506fb56a16bcfa0d25e1a2ebbd721ec","title":"Add Hall Right","path":"/ideCAD/add-hall-right","children":[]},{"id":"ci_fc691e9a55cd36acca93e9b4d1148bb2b5f3e6205e3247335c3f8e4291baceb3","title":"Hall Deletion","path":"/ideCAD/hall-deletion","children":[]},{"id":"ci_5d18adf92d6270c12f4d8bbe72f051600b479a9fd93f045b7360f405bb5a9762","title":"Shift Hall Left","path":"/ideCAD/shift-hall-left","children":[]},{"id":"ci_e13f2b7b95e95df8ccb30c64f4cd6ecc357472dbee58eea655ed81d31f4ad058","title":"Shift Hall Right","path":"/ideCAD/shift-hall-right","children":[]},{"id":"ci_50aa91000174e9d68b2c74b569aacc88b851eceeb08af367ef93f4a1b9124c26","title":"Shift Hall Up","path":"/ideCAD/shift-hall-up","children":[]},{"id":"ci_ee5afdfbe3edf47999c6c3cba24347feedb54de622fe003e9e7d0c19a32f414a","title":"Shift the Hall Down","path":"/ideCAD/shift-the-hall-down","children":[]},{"id":"ci_785158bd4c82e03f7a05c3cafb843d76eaaa3f5da11e97e29889e1b93bd14f9d","title":"Changing the Count of Partitions","path":"/ideCAD/changing-the-count-of-partitions","children":[]},{"id":"ci_6fd8c7df50cb3ab8c25f40975d92b29ff500426d5089e514935dbc562c568db8","title":"Changing the Partition Length","path":"/ideCAD/changing-the-partition-length","children":[]},{"id":"ci_5cecb42710672c7795b6890bd037365a575a32ebd447879da04004c8a7436c73","title":"Brace Adding to Partitions","path":"/ideCAD/brace-adding-to-partitions","children":[]}]},{"id":"ci_fa85c87fcf884e0bc7d2e80ac169ba35798bf450ce0d55c08cca95a91be9a63c","title":"Making Hall Form Settings","path":"/ideCAD/making-hall-form-settings","children":[{"id":"ci_380426749e228f1295b10f540c99ae18267ac1310ab6cae64c175d2001fc41a4","title":"Column Height","path":"/ideCAD/column-height","children":[]},{"id":"ci_c5ac87b123a2db39e079b7a0a40aadc4ba08f20b89f07849fa2bbcb1010f85ae","title":"Wall Height","path":"/ideCAD/wall-height","children":[]},{"id":"ci_1f8465ada4f6254b7f228434c0f427a5fbeaa1f7745ff8f4a5154fc668012667","title":"Hall Width","path":"/ideCAD/hall-width","children":[]},{"id":"ci_aae04a1cdaf4e409a565d8244d3f82db83021c77acb164222d314d907f38a633","title":"Roof Height","path":"/ideCAD/roof-height","children":[]},{"id":"ci_748d2d0a083eacbed03d30ab954ec5ee29ee50cce7f936ca09aade3c75c93f53","title":"Roof Slope","path":"/ideCAD/roof-slope","children":[]},{"id":"ci_5437f544a9cdc6d8a92c3aeea4adbb3feb95e5ac56ea519a8b9fbd556033c454","title":"Wind Column Count Setting","path":"/ideCAD/wind-column-count-setting","children":[]},{"id":"ci_5aa4898dd16b5e44b948096e369fb4948d6fb8cd7acd912ee7f743d469899f25","title":"Concrete Column Height Adjustment","path":"/ideCAD/concrete-column-height-adjustment","children":[]}]},{"id":"ci_22dd6685fef9a1da46f2fe75ba7a3ef7d97325e5a786df55dc4a296726dbd2e9","title":"Choosing the Building Type","path":"/ideCAD/choosing-the-building-type","children":[{"id":"ci_e67b30a1f4232db87430fe2b409b1b404850f8d567907c2cbbf29cdbb184d528","title":"Triangular Hall Type","path":"/ideCAD/triangular-hall-type","children":[]},{"id":"ci_06bcc0ca63cc182ba228688e985f1b112d8fe2a187445218ace15aac90f5ffcc","title":"Rectangular Hall Type","path":"/ideCAD/rectangular-hall-type","children":[]},{"id":"ci_a6ab6733757331ff15ebb4122dc55114226d9e81a163d52abe98f44929ff9cad","title":"Arc Form Type","path":"/ideCAD/arc-form-type","children":[]},{"id":"ci_785f39dadf76794a3cabf91369965c088825128b9808cfa2c930d9e3b7605b98","title":"Portal and Truss Selection","path":"/ideCAD/portal-and-truss-selection","children":[]}]},{"id":"ci_4e2cd37f6a226f4f79c3a9708ea542a36ce0e7c07b026596d923a3b563dc2800","title":"Hall Steel Element Settings","path":"/ideCAD/hall-steel-element-settings","children":[{"id":"ci_dfc78f4c549489e3ae06029e92011522c304e1d2bd7f6212fe232bb7a52faf80","title":"Hall Steel Column Settings","path":"/ideCAD/hall-steel-column-settings","children":[]},{"id":"ci_8d1684d2b1ae8fc8895fe09c37f44d17a219008a1f44abcc0bad351a7d1932c6","title":"Hall Steel Beam Settings","path":"/ideCAD/hall-steel-beam-settings","children":[]},{"id":"ci_38b5443ed08607a1261665343d4d3e665b1c5adf50bdb9262fa308441400cc0a","title":"Hall Steel Tie Settings","path":"/ideCAD/hall-steel-tie-settings","children":[]},{"id":"ci_defaa713156284880d07081685a9690a8ba78d7350e704d6aa83f141caf9cdeb","title":"Hall Steel Purlin Settings","path":"/ideCAD/hall-steel-purlin-settings","children":[]},{"id":"ci_a70d89459097510ad6102857ce4b410870db8fea7cf2659418446d67f84b572f","title":"Hall Steel Brace Settings","path":"/ideCAD/hall-steel-brace-settings","children":[]},{"id":"ci_4012fbd10163784483ddea13857e04d58abb8c0ad33bf1850a7f392baeef28c8","title":"Hall Sheeting Settings","path":"/ideCAD/hall-sheeting-settings","children":[]},{"id":"ci_74dddc1edbd6b599ca4059b0b0f0b459f1fb7ff09ae9f779115e676cccb4437b","title":"Hall Steel Truss Settings","path":"/ideCAD/hall-steel-truss-settings","children":[]},{"id":"ci_93202bd3d6f7054fe4fceb6d1a3a9c2253c11a47ef971d6ea62d893a7a9d0dc7","title":"Hall Steel Wind Column Settings","path":"/ideCAD/hall-steel-wind-column-settings","children":[]}]},{"id":"ci_d4f227d055c0ac9c57c9d8e3b9fa5916470691d597b69c1507e82ff1be8b4a95","title":"Hall Concrete Elements Settings","path":"/ideCAD/hall-concrete-elements-settings","children":[{"id":"ci_ad3f8e4bf0996fdbcf56b33f43c18debb95a7252b67cbc082ea13c1967ae2789","title":"Hall Concrete Column Settings","path":"/ideCAD/hall-concrete-column-settings","children":[]},{"id":"ci_2f6cba39e3022173d0577384ab2a7367a142dd6db211478d1278f93543255906","title":"Hall Foundation Settings","path":"/ideCAD/hall-foundation-settings","children":[]},{"id":"ci_7196ec50c91f32949f601c00080bf32bffd6098b7c8fbeef57edbf73e52afc77","title":"Hall Foundation Tie Settings","path":"/ideCAD/hall-coupling-beam-settings","children":[]},{"id":"ci_03fdddb02d2182aad14e12feb1c67624d4f2c18b9128b64898b9a7cb7dd0cb9e","title":"Hall Wall Settings","path":"/ideCAD/hall-wall-settings","children":[]}]}]}]}]},{"id":"ci_2734105cb4b5397e48ff2e0be9fc4fe7f2498a1af5102bc0487d702ce2505693","title":"Visualization","path":"/ideCAD/visualization","children":[{"id":"ci_02de59794318b9f25bb5dec07480894329320eab8a5ded7d77021e8bc71ac287","title":"Materials","path":"/ideCAD/materials","children":[{"id":"ci_819184acbd1ff12eefe65417fee437fc4ba4f570aaa8dd7f34b613d7621f72dd","title":"Material List","path":"/ideCAD/material-list","children":[]},{"id":"ci_7c7bd9b65c2b6b96e26b977276fba0e1212ec6fa9c6ffa60e0db2f896d84f934","title":"Material Editor","path":"/ideCAD/material-editor","children":[]},{"id":"ci_396ee5e9ce54238358e7f348650029060f578ac6c52484a8492b3126e0b8f5e7","title":"Creating a New Material","path":"/ideCAD/creating-a-new-material","children":[]},{"id":"ci_487832a4875aeb7d5f477b81129a72966c220c51d72f3d2234188bb0afcdc146","title":"Edit Material","path":"/ideCAD/edit-material","children":[]},{"id":"ci_53c7a04558b2c4c4898278820c810cbcbd8eded5b783e808d111686f7b7ebf01","title":"Grass & Fur Effect on Materials","path":"/ideCAD/grass-fur-effect-on-materials","children":[]},{"id":"ci_ad39459a791c5082e2d28bedc0b8905efd28a75932535b0a3ee015857fe3d96b","title":"Ligthing Effect in Materials","path":"/ideCAD/ligthing-effect-in-materials","children":[]},{"id":"ci_9590296ec37f47c0b41abffad52b593643c3bc78327fea6a9f1625a78fdc2f53","title":"Creating Landscape Material","path":"/ideCAD/creating-landscape-material","children":[]},{"id":"ci_401035f8d345149802d7095d9e767fc1374d6601429c56613cad6b77da907a54","title":"Creating a Frosted Glass Material","path":"/ideCAD/creating-a-frosted-glass-material","children":[]},{"id":"ci_83cb83d334e616941a2b34cc5072c691f9dff4784520d9483fecf3f79371ca34","title":"Creating Mirror Material","path":"/ideCAD/creating-mirror-material","children":[]},{"id":"ci_5d8ade9332224c77fcbe2736ba3a354c9f863ec76cdd8fe85b3f1702c66a2181","title":"Packaging of Project Textures","path":"/ideCAD/packaging-of-project-textures","children":[]},{"id":"ci_9430b62773cadc1c701ca3c78b6bba74ee0739198189beea79ef77c4d2c0c475","title":"Planar Texture Mapper","path":"/ideCAD/planar-texture-mapper","children":[]},{"id":"ci_feefdb1a34e88d34aa23d7c91cb1c427b4e440b08bdfee549845d00ea668f747","title":"New Origin Determination in Planar Texture Mapper","path":"/ideCAD/new-origin-determination-in-planar-texture-mapper","children":[]},{"id":"ci_83f03cb5311fe0cc4b0b29f1fa37a80730a8d912310e08f4b540e3e3dc6a9c0d","title":"Editing the Selection in Planar Texture Mapper","path":"/ideCAD/editing-the-selection-in-planar-texture-mapper","children":[]},{"id":"ci_33b6c0ebbc69335eb78c3a2cfeca9829dd114521f0f3cd9345a6261b72187557","title":"Edit Surface Mapping","path":"/ideCAD/edit-surface-mapping","children":[]},{"id":"ci_9c1f83110b15dd1547969b3a1a1bcae6f86b92b464997b153b0c70b434e5794e","title":"Surface Texture Mapping Methods","path":"/ideCAD/surface-texture-mapping-methods","children":[]},{"id":"ci_f751eb937ead21e1e5a3bf50906979277912f4210fa7435ad0e7492af6e24441","title":"Changing Material with the Edit Surface Mapping Command","path":"/ideCAD/changing-material-with-the-edit-surface-mapping-co","children":[]},{"id":"ci_2ae0ba728d7ecf0a0236411108a6c738c0eadacdb6639cb3aee5939169dc20e2","title":"Assign Material","path":"/ideCAD/assign-material","children":[]},{"id":"ci_68c98cde86c22f9bb79883840ad967f13d5fd00f1af25577ec784fd45aa0a2b3","title":"Material Conflict","path":"/ideCAD/material-conflict","children":[]}]},{"id":"ci_437569e0899cdc6373bd18f8f503da72ef902cc66ea516d49c81226c3e4227c1","title":"Camera","path":"/ideCAD/camera","children":[{"id":"ci_1d5123c8b3897442eb876a38514642376e3e00c489252d6ea48e5e23b8f44332","title":"Camera Settings","path":"/ideCAD/camera-settings","children":[]},{"id":"ci_8f3a439c3b248bfb36925006fed40f4c9410424fc8e994e400ba2dfae83175e0","title":"Defining a Camera","path":"/ideCAD/defining-a-camera","children":[]}]},{"id":"ci_1c223c19e855e18685dc21c24d10a6e37019d952cfb8b997847ee6e3039cfa0f","title":"Render","path":"/ideCAD/render","children":[{"id":"ci_56da6bd7ddd4fbde371c4bb98829c833957e1db6eb5a71fb11f0cc3e338197e7","title":"Render Settings","path":"/ideCAD/render-settings","children":[]},{"id":"ci_f0ad1e12a58b104a38694bf390a20ea8e20a23311ce196b810bdafb77cd07c23","title":"Creating Render","path":"/ideCAD/creating-render","children":[]},{"id":"ci_ec54adc530f087bd62ada700ea4c7ebd0f7d9c1682da67330b9bccc00868f2a4","title":"Temporarily Disable Grass and Emission Effects When Rendering","path":"/ideCAD/temporarily-disable-grass-and-emission-effects-whe","children":[]},{"id":"ci_7c9d762df5f9a1378e11ff23291e803455be21680cb7f233aaf9947ca149815e","title":"Furnished Story Plan Presentation","path":"/ideCAD/furnished-story-plan-presentation","children":[]},{"id":"ci_2af2e6b468bccbc2c8ea06bee9ad416b0634089d9e19ea00f8a6f5448b8b741b","title":"Recall Last Render","path":"/ideCAD/recall-last-render","children":[]},{"id":"ci_78dbf7f38ee3cb16166cfc1dafbdffd9bdea7e06d6d5070e1954dab38ec6936e","title":"Show Safe Frame","path":"/ideCAD/show-safe-frame","children":[]},{"id":"ci_63700459e40db09c82467eb6677fad861ecb9f1f054e6f21b297a1aa525f173e","title":"Post Process","path":"/ideCAD/post-process","children":[]}]},{"id":"ci_3b13f5ccb81d48172f94214745d01470d3b1c898a6462d8cfe5a0ce0428e0c91","title":"Animation","path":"/ideCAD/animation","children":[{"id":"ci_edd7eff0b324f59b7be1ea76c0dfde47cdbcff5d398721e693b256bf283e7fda","title":"Creating a Camera Path","path":"/ideCAD/creating-a-camera-path","children":[]},{"id":"ci_f1688dec4795dcd370987d7157e8302c878f528b2bf1e07787abe037cc6b1eec","title":"Editing Camera Path","path":"/ideCAD/editing-camera-path","children":[]},{"id":"ci_a4b5b744f886b0bc466b8d4a592dd609f8a33e70de465b126c445e3e1329230d","title":"Camera Animation","path":"/ideCAD/camera-animation","children":[]}]},{"id":"ci_c5c19f15bd0ae04e2b1f68906e234dcb9d3053a4982db5b9fb453c63c3a88f4f","title":"Source of Light","path":"/ideCAD/source-of-light","children":[{"id":"ci_5f88ce3e2c1aa7f38c63c38c63f49e7ab6dc93c6409e788e032ad500ad71f44b","title":"Photometric Light Settings","path":"/ideCAD/photometric-light-settings","children":[]},{"id":"ci_5b1d7292db951803cd2eaad7cf212fde87251f66fe4aae0283e0a59cb6958081","title":"Defining a Photometric Light","path":"/ideCAD/defining-a-photometric-light","children":[]},{"id":"ci_76b53944c3e1f52f29d8a7430a2e9890a7b2def3e7e584192b5718e7d121748d","title":"Point Light Settings","path":"/ideCAD/point-light-settings","children":[]},{"id":"ci_5b79290c93cc82ba85e23086ab6bc263670a3dc29c1b523d0050d3ab72397a13","title":"Defining a Point Light","path":"/ideCAD/defining-a-point-light","children":[]},{"id":"ci_d91d004dee11a186e7e43bc1e5b1ed8b651bc5613f4dd7c7f650b3067d33753e","title":"Spot Light Settings","path":"/ideCAD/spot-light-settings","children":[]},{"id":"ci_3a3a732d705f0857b1910691c045f17ec99ff7083d4000655ae4f36d63c492af","title":"Defining a Spot Light","path":"/ideCAD/defining-a-spot-light","children":[]},{"id":"ci_9519fbf254b2f783ffbdd5dec2412fb201a5e381c3175577bf3007795a901eec","title":"Directional Light Settings","path":"/ideCAD/directional-light-settings","children":[]},{"id":"ci_341b1d95b987fdc0d09f8e34c5cf1ef0b97aa81ba65de2b91fb60df19fad208c","title":"Defining a Directional Light","path":"/ideCAD/defining-a-directional-light","children":[]}]}]},{"id":"ci_111890ea3f947559cbb3f7d9287bd65fc7a7390a7abd2ffeb99e8f0cc79bdb23","title":"Integrated Structural Engineering","path":"/ideCAD/structural-engineering","children":[{"id":"ci_1acf73f8c7885883ba2c461b7ab7b8da346b94ce9f51d5ddec49affd5b488775","title":"International Design Codes","path":"/ideCAD/international-design-codes","children":[{"id":"ci_94760bb2571e0cc736bfe30650494f60b3d9d96fc3b045919e5228d2570b7aef","title":"ASCE 7-16 Seismic Design","path":"/ideCAD/asce-7-16-seismic-design","children":[{"id":"ci_09be6a5285e7b1d9d41d66f95f50f64844309f7813ae16848d1e2831b82f1254","title":"ASCE 7-16 Earthquake Ground Motion...","path":"/ideCAD/asce-7-16-earthquake-ground-motion","children":[{"id":"ci_77a3a2bf2fba53366660f95a5f4558fe69312a55080f170c193d6cca64080541","title":"Ground Motion Levels per ASCE 7-16 with ideCAD","path":"/ideCAD/earthquake-ground-motion-levels-1","children":[]},{"id":"ci_d77ba491eadd0008d5e159799bba3f127ad87cd28897fcdf7e0b53e10210cf6e","title":"Spectral Response Acceleration Parameters and Design Spectral Acceleration Parameters per ASCE 7-16 with ideCAD","path":"/ideCAD/11-4-4-11-4-5-spectral-response-acceleration-param","children":[]},{"id":"ci_940c7b8c3cfa40ce82a412af928a47c98b91446d2b428d6812d85440ffaf7e45","title":"Site Coefficients per ASCE 7-16 with ideCAD","path":"/ideCAD/11-4-4-site-coefficients","children":[]},{"id":"ci_078be0440a4c0c67a54abee44d6df4ad033943a07673d34a4adb4de39b80d195","title":"Horizontal Elastic Design Spectrum per ASCE 7-16 with ideCAD","path":"/ideCAD/11-4-6-horizontal-elastic-design-spectrum","children":[]},{"id":"ci_a86cca3e8941663efb8b54b549c3b0d125595fd9bc4fb91742c9c86709b85325","title":"Site-Specific Ground Motion Procedures per ASCE 7-16 with ideCAD","path":"/ideCAD/11-4-8-site-specific-ground-motion-procedures","children":[]},{"id":"ci_ed734a8424b5b11d76f02618b6a08eb8fe340e4eb010641439ffb6afe82dc4b3","title":"Vertical Elastic Design Spectrum per ASCE 7-16 with ideCAD","path":"/ideCAD/11-9-2-vertical-elastic-design-spectrum","children":[]}]},{"id":"ci_8bafbab862192bb474237fc32f6f7f5bdee10631fafed194909dd5da694e2416","title":"ASCE 7-16 Seismic Design Code General Principles.","path":"/ideCAD/seismic-design-codes-general-principles","children":[{"id":"ci_e3ffa077f762e51074faee557ac8b5e21c0b3989a10ce815c20f71554317a8c0","title":"Risk Category of Building and Importance Factors per ASCE 7-16 with ideCAD","path":"/ideCAD/1-5-1-1-5-2-risk-category-of-building-and-importan","children":[]},{"id":"ci_751af99fe00008e6cb113fc4ffb3d9b4cb7fa57217943eff4e5bcb9fa7552c54","title":"Seismic Design Category (SDC) per ASCE 7-16 §11.6","path":"/ideCAD/11-6-seismic-design-category-sdc","children":[{"id":"ci_e8b24b9e6d2d7db1f20f4dd9feb2534e2243f226062340890278e37235412fd9","title":"Seismic Design Category (SDC) per ASCE 7-16 with ideCAD","path":"/ideCAD/determining-seismic-design-category-sdc","children":[]}]},{"id":"ci_52d5a5d91d2f8b86ef235bce3ef95341a49f7e42a6c9b9549815f651687046ad","title":"Building Performance Levels per ASCE 7-16","path":"/ideCAD/11-2-building-performance-levels","children":[]},{"id":"ci_59e4b39db5ff380070e302be857daedee1d04b53bd6b294d9930057ab56fe436","title":"Building Base and Building Height Limitation According to Structural System per ASCE 7-16 with ideCAD","path":"/ideCAD/building-base-and-building-height-limitation-accor","children":[]},{"id":"ci_ed8c16388bf58228242488c1db157d6487772414f29f35eb87f533006ee346a5","title":"Building Performance Targets per ASCE 7-16, FEMA P-695, and NIST","path":"/ideCAD/building-performance-targets-according-to-asce-7-1","children":[]},{"id":"ci_d52bdbbe8bf72bf36228a913a7040155105fd9604863816dea707a7de8e2c2ef","title":"Evaluation / Design Approaches to be Applied per ASCE 7-16","path":"/ideCAD/evaluation-design-approaches-to-be-applied-accordi","children":[]},{"id":"ci_33daaa7de0fd2e47e1e07cfbea013ac68eb442d16ec92ffbc40c7722df840ee0","title":"Irregular and Regular Classification per ASCE 7-16","path":"/ideCAD/asce-12-3-2-irregular-and-regular-classification","children":[{"id":"ci_95c9bebaf6171768cc96eeafe75b1e417e95184a1d7ad59b5889c285ac971a51","title":"Horizontal Structural Irregularities per ASCE 7-16 §12.3.2.1","path":"/ideCAD/asce-12-3-2-1-horizontal-structural-irregularities","children":[{"id":"ci_d11fc2e4b1373796e1a2dc2cf2cf565e68b0501611571a259248354efe1f8970","title":"1a and 1b Torsional Irregularities per ASCE 7-16","path":"/ideCAD/asce-1a-and-1b-torsional-irregularities","children":[{"id":"ci_3109a0059602e8cf7a84c8134d17abdd1b01a54a9fc23e0b60809890c781c2fa","title":"Torsional Irregularities per ASCE 7-16 with ideCAD","path":"/ideCAD/asce-earthquake-code-statement-for-torsional-irreg","children":[]}]},{"id":"ci_fa6bc274b47f2dc96d0cc371eaaa1d01c0f6c085577795083644ee28297a34a2","title":"Reentrant Corner Irregularity per ASCE 7-16","path":"/ideCAD/reentrant-corner-irregularity-asce","children":[{"id":"ci_dc676595b878253641f3f204e81f05e7a6b6401070da6a4b224e1739fd87b859","title":"Reentrant Corner Irregularity per ASCE 7-16 with ideCAD","path":"/ideCAD/asce-earthquake-regulation-statement-reentrant-cor","children":[]}]},{"id":"ci_d5b94c8b6b7487c2897578ac5e5577f2b4edb7ed5c131e012318c183f5cdb1de","title":"Diaphragm Discontinuity Irregularity, ASCE 7-16","path":"/ideCAD/asce-diaphragm-discontinuity-irregularity","children":[{"id":"ci_d9b06e60e5d614bc171d6bc7d0bc2a07260ab3328969fba2d8e9ce34bdf718e9","title":"Diaphragm Discontinuity Irregularity per ASCE 7-16 with ideCAD","path":"/ideCAD/asce-earthquake-code-statement-diaphragm-discontin","children":[]}]},{"id":"ci_f7a4dbfcc5a67e0b47efec0912e5e3588443d42d0774e14a094d36fb827834d1","title":"Out-of-plane Offset Irregularity per ASCE 7-16","path":"/ideCAD/asce-out-of-plane-offset-irregularity","children":[]},{"id":"ci_b21c1d2e11fc748a88ee884dae261d94595b9c0398c8260a251dd0cd36acc4e6","title":"Nonparallel System Irregularity per ASCE 7-16","path":"/ideCAD/asce-nonparallel-system-irregularity","children":[]}]},{"id":"ci_d98e9665883f8b85c8062d85d0f1ebb7a6184897c3edebbdd328cd9bd127c261","title":"Vertical Structural Irregularities per ASCE 7-16 §12.3.2.2","path":"/ideCAD/asce-12-3-2-2-vertical-structural-irregularities","children":[{"id":"ci_b3fa73074a32731c1a6ca922984c5d7b50a2553aa0743e3aa7c9877257a50582","title":"Stiffness–Soft Story Irregularity and Extreme Soft Story Irregularity per ASCE 7-16","path":"/ideCAD/stiffnesssoft-story-irregularity-and-extreme-soft-","children":[{"id":"ci_d9fdf7dd1c97f727abb274b61294bd78fa30986fc81c09d14a45625307110ff6","title":"Soft Story Irregularity, ASCE 7-16","path":"/ideCAD/asce-earthquake-regulation-statement-soft-story-ir","children":[]}]},{"id":"ci_43da1d59e55aa8d0f2656305e999c6389c0395dbba729c1bc9dabf407428df21","title":"Weight (Mass) Irregularity per ASCE 7-16","path":"/ideCAD/asce-weight-mass-irregularity","children":[]},{"id":"ci_0b08eb1184079178876adec801252652e4929e8043817321e1ac24408fa6ed25","title":"Vertical Geometric Irregularity per ASCE 7-16","path":"/ideCAD/asce-vertical-geometric-irregularity","children":[]},{"id":"ci_13555e00a1327e86186e5075873a860ed4e4049bdccbc4aaca397273aac3147d","title":"In-Plane Discontinuity in Vertical Lateral Force-Resisting Element Irregularity per ASCE 7-16","path":"/ideCAD/asce-in-plane-discontinuity-in-vertical-lateral-fo","children":[]},{"id":"ci_c8c6ab6f5195d83a403b38f793d65f9c262e5dce9564e0bcdd3a5a212d063f57","title":"Discontinuity in Lateral Strength–Weak Story Irregularity per ASCE 7-16","path":"/ideCAD/asce-discontinuity-in-lateral-strengthweak-story-i","children":[{"id":"ci_bc1dff296bfbdd5009fd17f58c24a851e120ff2d667c17133c9f8951e039d3d1","title":"Weak Story Irregularity per ASCE 7-16","path":"/ideCAD/asce-earthquake-regulation-statement-weak-story-ir","children":[]}]}]}]}]}]},{"id":"ci_6d39e47aaeb789c503cf1ac6b43420cdc873052fd0c83d746915b981849cab95","title":"ASCE 7-16 Strength-Based Design","path":"/ideCAD/asce-7-16-strength-based-design","children":[{"id":"ci_c9cbe0868ce9ef3b41a36160ccc6889e0b0a08dbfe8059e591b40aacbc2bd70d","title":"Design Coefficients and Factors for Seismic Force-Resisting System per ASCE 7-16 §11.2","path":"/ideCAD/according-to-section-12-2-design-coefficients-and-","children":[{"id":"ci_6ed00b7d57e4534802b8d59ab07cd87541b835498c9f07cd97deffd5f538ba13","title":"Structural System Selection per ASCE 7-16 with ideCAD","path":"/ideCAD/12-2-structural-system-selection","children":[]},{"id":"ci_986556bd85527bc1bbaf8cdf39f553e2e17210946fb989e13fd2d3a80e1e0795","title":"Increased Structural Height Limit per ASCE 7-16 with ideCAD","path":"/ideCAD/12-2-5-4-increased-structural-height-limit","children":[]},{"id":"ci_544216b9b6ba349120bf8a6460e68e0bcbff61fb01e5ee7429e2240775f87211","title":"Shear Wall–Frame Interactive Systems per ASCE 7-16 with ideCAD","path":"/ideCAD/12-2-5-8-shear-wallframe-interactive-systems","children":[]}]},{"id":"ci_b2aaa64dd056af6aa0922e5ecb13243ea6767a687800523869d327462342ce8c","title":"Conditions Regarding Ductility Levels of Structural Systems per ASCE 7-16 §11.2","path":"/ideCAD/conditions-regarding-ductility-levels-of-structu-1","children":[{"id":"ci_7215a83e9f596ed54b5d6b3405d01e62281cd820c98c231f51d2c6f28481ed28","title":"Tipping Shear Force Range Control of Shearwalls per ASCE 7-16 with ideCAD","path":"/ideCAD/tipping-shear-force-range-control-of-shearwalls","children":[]},{"id":"ci_1de3894c0c7331451e4d4198df7a35458282b1d99ada30d8b94e17e3694ebb88","title":"Structural Systems in Different Directions per ASCE 7-16 with ideCAD","path":"/ideCAD/12-2-2-structural-systems-perpendicular-to-each-ot","children":[]},{"id":"ci_60c644ee0bf4c669778763183a7bcd159dad1a51b3afc5a224c1fa85db6b4df9","title":"Structural Systems in the Same Direction per ASCE 7-16 with ideCAD","path":"/ideCAD/12-2-3-structural-systems-in-same-direction","children":[]}]},{"id":"ci_41fc30ed3932ab6e4d0c2bf82674b8558222327fe85a3a50d82bf0166cd06b8a","title":"Application of Overstrength Factor per ASCE 7-16 §12.2.1","path":"/ideCAD/12-2-1-application-of-overstrength-factor","children":[{"id":"ci_fbf2fe036e682c2855f1d89d775e4a9147c7ab6d5b020ac6c88f6cd0b1997a19","title":"The Overstrength Factor per ASCE 7-16 with ideCAD","path":"/ideCAD/the-overstrength-factor","children":[]},{"id":"ci_585bf8ddd7dde3c2d521919f20c0a55a663992887ee44c1aa9cff9227e17e3b4","title":"Ductile Forces per ASCE 7-16 with ideCAD","path":"/ideCAD/ductile-forces","children":[]},{"id":"ci_501c9fd1c49e8018c46fada8f2dd40d9366e967c5895861f819923ce8dff8282","title":"Non-Ductile Internal Forces per ASCE 7-16 with ideCAD","path":"/ideCAD/non-ductile-internal-forces","children":[]}]},{"id":"ci_4dd376fb4ca9782a41ca70b1ea4f3591273d7471f826e796c0a799c6244ccf7c","title":"Application of Deflection Amplification Factor per ASCE 7-16 §11.2.1","path":"/ideCAD/application-of-deflection-amplification-factor","children":[{"id":"ci_b29282f8a6b2572541b37151dfe9abf816ee1a74efc54dca7634392f3c7ff895","title":"Deflection Amplification Factor per ASCE 7-16 with ideCAD","path":"/ideCAD/deflection-amplification-factor","children":[]}]},{"id":"ci_421e6aa9a10f3685e6da3ddcb2bc27d634830646083ef72a64aecb2af7e32df5","title":"Redundancy Factor per ASCE 7-16 §12.3.4","path":"/ideCAD/redundancy-factor-asce-7-16-section-12-3-4","children":[{"id":"ci_ded9de6db6b198f8e68f5f3494eea1de08781bfb69e4b1a93990092735bd8c53","title":"Redundancy Factor per ASCE 7-16 with ideCAD","path":"/ideCAD/detailed-explanation-of-redundancy-factor","children":[]}]},{"id":"ci_c367333aac3af27a32a9d7b3a372509affadef8109041664b90e047d62f86d2f","title":"Reduced Design Response Spectrum for Modal Analysis per ASCE 7-16 §12.9.1.2","path":"/ideCAD/reduced-design-acceleration-spectrum-for-modal-ana","children":[{"id":"ci_196627afcf674babcb8b89053bf387afc96fc5f525efe00fdfbea917dce71932","title":"Response Modification Coefficient for Modal Analysis per ASCE 7-16 with ideCAD","path":"/ideCAD/seismic-reduction-for-modal-analysis","children":[]},{"id":"ci_81e61bcd3746e7a8019f8512d1460307f4e5967f4d01cff5226f9b679ab1dece","title":"Design Response Spectrum for Horizontal Earthquake Effects per ASCE 7-16 with ideCAD","path":"/ideCAD/the-reduced-design-acceleration-spectrum-for-horiz","children":[]}]},{"id":"ci_76ca0df8add67c41667b897ce8d4921ed2b4351ec8a66ce694c855a3a5188049","title":"Seismic Load Effects and Combination per ASCE 7-16 §12.4","path":"/ideCAD/seismic-load-effects-and-combination-per-asce-7-16","children":[{"id":"ci_5d8a8d1f39d602d634d48a4e736688c28edf3e3a272e7a1caa4ec8531d951d65","title":"The Direction Combination of Horizontal Seismic Load Effect per ASCE 7-16 with ideCAD","path":"/ideCAD/the-direction-combination-of-horizontal-earthquake","children":[]},{"id":"ci_1f6274f51738945bef9049d650b98a6cd625b24a2bf6b02c8a64b93048db09ec","title":"Combining Horizontal and Vertical Earthquake Effects per ASCE 7-16 with ideCAD","path":"/ideCAD/combining-horizontal-and-vertical-earthquake-effec","children":[]},{"id":"ci_217ed395ca75e4c0f9cab1e460518e9429d36a32fb46857fe89de3037bdacc9d","title":"Vertical Seismic Load Effect per ASCE 7-16 §12.4.2.2","path":"/ideCAD/12-4-2-2-vertical-earthquake-impact","children":[{"id":"ci_01ac9c8c95665fdb82518463cce1dbd11e649380337e5f0d2056d24c7cf6cced","title":"Vertical Earthquake Modal Response Spectrum Analysis per ASCE 7-16 with ideCAD","path":"/ideCAD/vertical-earthquake-analysis-with-local-vertical-v","children":[]},{"id":"ci_8b588308b5546aa4445a76a03eb1994afebb0a3e4ee651766070b083a1e0176a","title":"Vertical Earthquake Effect per ASCE 7-16 with ideCAD","path":"/ideCAD/12-4-4a-vertical-earthquake-calculation","children":[]}]}]},{"id":"ci_8dac37b8a86c7e99aa379d3516d1589a249b6ba686eea1a9e6f0d434f053847a","title":"Load Combination and Strength Design per ASCE 7-16 §2.3","path":"/ideCAD/load-combination-and-strength-design","children":[{"id":"ci_6298209f62335fd3dd2fbc59e8d5e38a802c97abad563c723ed5c420847d6f35","title":"Application of Combining Earthquake Impact with Other Impacts per ASCE 7-16 with ideCAD","path":"/ideCAD/application-of-combining-earthquake-impact-with-ot","children":[]}]},{"id":"ci_ec13f76421972fd624e319213e56b3bf87d241b653892ad53dcd0e02778cc6c0","title":"Analysis Procedure Selection per ASCE 7-16 §12.6","path":"/ideCAD/12-6-analysis-procedure-selection","children":[{"id":"ci_13de0b218040a0a4a06c1a8f125067a8b9a8018737b0e84b0396855b0096cbfb","title":"Equivalent Lateral Load Application Limits per ASCE 7-16 with ideCAD","path":"/ideCAD/equivalent-seismic-load-application-limits","children":[]},{"id":"ci_8cce7fd07feb3da1eb574aeaf39ff7ef69a7998b26e1eba48cad73915687b0cd","title":"Linear Dynamic Analysis per ASCE 7-16 with ideCAD","path":"/ideCAD/12-9-linear-dynamic-analysis","children":[]}]},{"id":"ci_7ec5c274a9ed74075d465f7046708b7b1a965fb40fcd582b5ca64866b7c1eb7d","title":"Modeling Criteria per ASCE 7-16 §12.7","path":"/ideCAD/12-7-modeling-criteria","children":[{"id":"ci_f2eaef8ac6cbb743bc64a95611250c72641fb2364d956d8b8ed4e1a9c505df07","title":"Foundation Modeling per ASCE 7-16 §12.7.1","path":"/ideCAD/12-7-1-foundation-modeling","children":[{"id":"ci_daf43bd49191126ed5688f5ef13f91408a1cdc9bffcb0a3cb8ee047fe4ba7d2a","title":"Foundation Modeling Application per ASCE 7-16 with ideCAD","path":"/ideCAD/application-of-foundation-modeling","children":[]}]},{"id":"ci_575e8c264923f49ea088eeaa0f853236017bdd1624e40ee8509ed7172f7df4e9","title":"Effective Seismic Weight per ASCE 7-16 §12.7.2","path":"/ideCAD/12-7-2-effective-seismic-weight","children":[{"id":"ci_68fe07e11cea14395696702bf24b36be0db43015590b4bf4f44dbc3fd38d020e","title":"Effective Seismic Weight Definition per ASCE 7-16 with ideCAD","path":"/ideCAD/defining-masses-of-singular-node-points","children":[]}]},{"id":"ci_95add81d7c113fd778b75b3f053ec4bec9c7eff56840e734a71024d80ba335a7","title":"Structural Modeling per ASCE 7-16 §12.7.2","path":"/ideCAD/12-7-3-structural-modeling","children":[{"id":"ci_67cb2fbc9bf3c6f220df5e0c2d6ac502523acb63779a47cc48131b368e255530","title":"Structural Modeling with Finite Element Method per ASCE 7-16","path":"/ideCAD/structural-modeling-with-finite-element-method","children":[]},{"id":"ci_5fa1b55e94431551567ea27b81dfbad64aa4ecd6670ecbde6286d927931ba338","title":"Modeling of Shearwalls per ASCE 7-16 with ideCAD","path":"/ideCAD/modeling-of-shearwalls-asce-7-16","children":[]},{"id":"ci_aa975833da5e1c39f8ae229937367d0090ca7ff09b0738ae2a91c31790a6cc74","title":"Modeling Story Slabs per ASCE 7-16 with ideCAD","path":"/ideCAD/modeling-story-slabs","children":[]}]},{"id":"ci_4babf32df5f5846ea2a66ddddab84d08c90e67395bc9d0e441410e75a7dbde63","title":"Interaction Effects per ASCE 7-16 §12.7.2","path":"/ideCAD/12-7-4-interaction-effects","children":[]},{"id":"ci_9452bd7704e53be84ced2afae915347fc8d9f1afb789dac68afe883ef92df7d6","title":"Damping Ratio per ASCE 7-16 with ideCAD","path":"/ideCAD/damping-ratio","children":[]}]},{"id":"ci_48e2646f46569d40d36fd0cdb53fc087a573c0fb8983f50e8a0c178684b002d1","title":"Modeling of Masses per ASCE 7-16 with ideCAD","path":"/ideCAD/12-7-2-modeling-of-masses","children":[]},{"id":"ci_7279cea87415b3b0c132bfd44ce1c8b9b5015c24757d126e55072ffde09b88be","title":"Effective Section Stiffness per ASCE 7-16 §12.7.3","path":"/ideCAD/12-7-3-effective-section-stiffness","children":[{"id":"ci_6b5d877ce14f9d1eed51132c008d29faa2bf2b9ce71da5f418456d5778687846","title":"Effective Section Stiffness Modifier per ASCE 7-16 with ideCAD","path":"/ideCAD/using-the-multipliers-given-in-table-6-6-3-1-1-a","children":[]}]},{"id":"ci_875a8bce5fc4e14ad0b550b6494268d49d4660183e63bfc53ad7b906cea21b03","title":"Equivalent Lateral Force Method (ELF) per ASCE 7-16 §12.8","path":"/ideCAD/12-8-equivalent-lateral-force-method-elf","children":[{"id":"ci_e0a3f8a541184b94981dfa02ccfdc3f418050dbec271edb5220b9e376beefa5d","title":"Seismic Base Shear Determination per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-1-determination-of-seismic-base-shear","children":[]},{"id":"ci_1d9ae4cb1abbcd0681e0824b7164fc01cc8bd2d015b1dcbf9fa18ab566ea02a8","title":"Determination of the Building's Fundamental Period per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-2-determination-of-the-building-s-fundamental","children":[]},{"id":"ci_a144a20b0f7735a0825783b9f1d3b46ea4629110d49394bb0de78c182f5b7ee9","title":"Determination of Equivalent Lateral Force Acting on Stories per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-3-determination-of-equivalent-lateral-force-a","children":[]},{"id":"ci_7e5bfed0d145b292198a1a97e907b7c88c73c78032df4426e3f8083b5b7d7f3f","title":"Seismic Response Coefficient for Equivalent Lateral Force Method per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-1-1-seismic-response-coefficient-for-equivale","children":[{"id":"ci_a192403b05c5ba6cfb09682e30932af3702655fdb8b9ffdf34fa5ddb0cebe2f6","title":"Detailed Explanation of Seismic Response Coefficient","path":"/ideCAD/detailed-explanation","children":[]}]}]},{"id":"ci_35a4677635779560a9f4ab018f392415f230cbc8b3d94bd4bf3c6efe2e14e459","title":"Inherent Torsion per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-4-1-inherent-torsion","children":[]},{"id":"ci_9d14e52741331f3dcd18d8e2f99cfd38821cc1335a68d1dde485b6e9225d8baf","title":"Accidental Torsion per ASCE 7-16 §12.8.4.2","path":"/ideCAD/12-8-4-2-accidental-torsion","children":[{"id":"ci_22331ec17f45274391b7f4c640293d3ba034934f8bc564723c17a1a541294907","title":"Accidental Torsion per ASCE 7-16 with ideCAD","path":"/ideCAD/application-of-accidental-torsion","children":[]}]},{"id":"ci_a5f1c16e81740941c5b451b053918a8f12d80e15d9478dc3f4a512022220cb49","title":"P-Delta Effects per ASCE 7-16 with ideCAD","path":"/ideCAD/12-8-7-p-delta-effects","children":[]},{"id":"ci_3ce9df9f6b899a87e251764b0e30a6b9b5e3b5f6e9a974d68399b04d531a1d6b","title":"Linear Dynamic Analysis Methods per ASCE 7-16 with ideCAD","path":"/ideCAD/12-9-linear-dynamic-analysis-methods","children":[]},{"id":"ci_7ef5f12e8bea82c9d186475686cd6d63d47aa3277cfe8179fa405b6b2cfd6c93","title":"Modal Response Spectrum Analysis per ASCE 7-16 §12.9.1","path":"/ideCAD/12-9-1-modal-response-spectrum-analysis","children":[{"id":"ci_cffa1a3f3629dd054a0182c1f290f1d43dcd43ee127e0899cbb2effa44ad0154","title":"Modal Response Spectrum Analysis and Parameters per ASCE 7-16 with ideCAD","path":"/ideCAD/calculation-of-modal-response-parameters","children":[]}]},{"id":"ci_232ae3b67ce0eddbb70f4af98418bda509bf02680a661680899a3f0f77d3dcfd","title":"Scaling Design Values of Combined Response per ASCE 7-16 §12.9.1.4","path":"/ideCAD/12-9-1-4-scaling-design-values-of-combined-respons","children":[{"id":"ci_67ebe52ece7a5facf3f2ed16fc0fa6840e0223c6b7fd7847daceef7b1cc40961","title":"Scaling Design Values of Combined Response per ASCE 7-16 with ideCAD","path":"/ideCAD/scaling-design-values-of-combined-response","children":[]}]},{"id":"ci_ee66a17412c763e7bf15e54a01bb92c8ba7be7f9e232cdd6f495266a0c4a5034","title":"Diaphragms, Chords, and Collectors per ASCE 7-17 with ideCAD","path":"/ideCAD/12-10-diaphragms-chords-and-collectors","children":[]},{"id":"ci_59499b92f67c3635cdc2489588cd5c5c24c1496e481d1b59478d8948b0a68db2","title":"Determination and Limitation of Story Drifts per ASCE 7-16 §12.12","path":"/ideCAD/12-12-determination-and-limitation-of-story-drifts","children":[{"id":"ci_ed8c0f75e8d398aea40accd4f54744822870c799dc4a561f2a2b51e3d4b2084e","title":"Determination of Story Drifts per ASCE 7-16 with ideCAD","path":"/ideCAD/determination-of-story-drifts","children":[]},{"id":"ci_b5a3e0c55a75f3c5516e4e3785c542cc7ff70b4442358385c4ffe3ba4726305f","title":"Story Drifts Control Reports per ASCE 7-16 with ideCAD","path":"/ideCAD/story-drifts-control-reports","children":[]},{"id":"ci_e3666b4c1cb31055d2bc6b0d3731a891bd9f5c451a3f6b298c1f6aa7ea7004d5","title":"Story Drifts Control Example Calculation","path":"/ideCAD/story-drifts-control-example-calculation","children":[]}]},{"id":"ci_b7eec72adbbf440c66bef127c4c906372f33969306101d43219f6559bbd13e6e","title":"Foundation Design per ASCE 7-16 §12.13","path":"/ideCAD/12-13-foundation-design","children":[{"id":"ci_9fd376f232c647bdc7c698981ccf43552fc04c5ab66255bceac5896a71f9f2e6","title":"Determining the Forces to be Transferred to Foundation per ASCE 7-16 with ideCAD","path":"/ideCAD/determining-the-forces-to-be-transferred-to-founda","children":[]}]}]},{"id":"ci_c2d11016ff818fc0ac3eafea195165db999eea6b7aa50deb7491ad531e626d7d","title":"ACI 318-19 Reinforced Concrete Design for American Standard","path":"/ideCAD/aci-318-19-concrete-design-for-american-standard","children":[{"id":"ci_d7d76920e4a208081918b74c4ee15a762a4b089689a6f407798239ee9e746779","title":"Materials and Reduction Factors per ACI 318-19 §19, §20, and §21","path":"/ideCAD/materials-and-reduction-factors","children":[{"id":"ci_129ff683f24a0360c03811c6bfea0cca3e9738d85de5834147abb5cb482ed309","title":"Concrete and Reinforcement Materials per ACI 318-19 with ideCAD","path":"/ideCAD/concrete-reinforcement-materials","children":[]},{"id":"ci_a1a333e84617c3ee4ec24724e6feee518b1e72cebd2814603ead1de677fda0b7","title":"Strength Reduction Factors per ACI 318-19 with ideCAD","path":"/ideCAD/strength-reduction-factors","children":[]}]},{"id":"ci_4337ce1460485e9b5dbf0ce23e1740921f12732833d6a4a4cf2411f447b7dfe2","title":"Load Factors and Combinations per ACI 318-19 with ideCAD","path":"/ideCAD/load-factors-and-combinations","children":[]},{"id":"ci_576b9cfbf987a118c882e109cb77d0991d3e5acc62d271416ef248db16b8dced","title":"Structural Analysis per ACI 318-19 §6.3 §6.6","path":"/ideCAD/structural-analysis-per-aci-318-19","children":[{"id":"ci_5342ca309fb2ba546e38ff5325ea8ed549b743a501aa72156ad042b5d4b9b33a","title":"T-Beam Geometry per ACI 318-19 with ideCAD","path":"/ideCAD/t-beam-geometry","children":[]},{"id":"ci_d9eed42de7192c5017650a7d4fcc46f18e2c90b00466d90c37d5fd2076553dd6","title":"Effective Section Properties per ACI 318-19 with ideCAD","path":"/ideCAD/effective-section-properties","children":[]}]},{"id":"ci_3f1a3bf7019e9d8c3197e104d42420e52fe827948f6ff707b212906243b280a6","title":"Sectional Strength per ACI 318-19 §22","path":"/ideCAD/sectional-strength","children":[{"id":"ci_e8904501be7d21ddc8f65e1675d8174e65246c30eb097cdf8f73ddb7374c5f55","title":"Flexural Strength per ACI 318-19 with ideCAD","path":"/ideCAD/flexural-strength","children":[]},{"id":"ci_617be83421cf1196592729a1e90b8edb1c02978468ee993192b5bb3697e324c0","title":"Axial strength or Combined Flexural and Axial Strength per ACI 318-19 with ideCAD","path":"/ideCAD/axial-strength-or-combined-flexural-and-axial-stre","children":[]},{"id":"ci_d63848ab282acfd34608a9c009add0c98f618609e0b8104f29eed2d23a0f2ac0","title":"One-Way Shear Strength per ACI 318-19 with ideCAD","path":"/ideCAD/one-way-shear-strength","children":[]},{"id":"ci_1ad055f1897bed0d4b40df8e01e6882fc93b48bcc4cdf303cab26f245af75bb1","title":"Two-Way Shear Strength per ACI 318-19 with ideCAD","path":"/ideCAD/two-way-shear-strength","children":[]},{"id":"ci_79a963e1395f5e114c9d74bfb1da187f38b5eac0597a6815bf1dc280a2412dda","title":"Torsional Strength per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/torsional-strength","children":[]}]},{"id":"ci_4ed48c3058aed38ed41d83ce92d5c7f1a33ff6f0a2d9e9abafac01ff765b751c","title":"Reinforcement Details per ACI 318-19 §25","path":"/ideCAD/reinforcement-details","children":[{"id":"ci_472b83f73121b5adaa38a8362d0220e0911809464d35155913c569bcd4f8d5be","title":"Minimum Spacing of Reinforcement per ACI 318-19 with ideCAD","path":"/ideCAD/minimum-spacing-of-reinforcement","children":[]},{"id":"ci_9e833b3cf0b59af36f27382b3da779e6ef300b2ddba22e1610a76fc71e7ab7bc","title":"Standard Hooks, Seismic Hooks, Crossties, and Minimum Inside Bend Diameters per ACI 318-19 with ideCAD","path":"/ideCAD/standard-hooks-seismic-hooks-crossties-and-minimum","children":[]},{"id":"ci_5b0bef580dc16af2e7fdcdfc55ce055318dc81d357e72740ec7fbca2f738b997","title":"Development of Reinforcement per ACI 318-19 with ideCAD","path":"/ideCAD/development-of-reinforcement","children":[]},{"id":"ci_11458f6d85e3dbd4a1544bc0bce938059362003cb5e9559e4b9e0c0ce96d46a9","title":"Splices per ACI 318-19 with ideCAD","path":"/ideCAD/splices","children":[]},{"id":"ci_e4005735d19388cd1857200194677403da7925c1bb4f8642eb02855d7f946fa8","title":"Stirrups per ACI 318-19 with ideCAD","path":"/ideCAD/stirrups","children":[]},{"id":"ci_d8b1f3013bd0577ecdffdb429b458dd11762e603d3bf04428cf9898e2ad556f6","title":"Transverse Reinforcement per ACI 318-19 with ideCAD","path":"/ideCAD/transverse-reinforcement","children":[]}]},{"id":"ci_3fee28dcd8bd9bb9511332e5ef8c12e0f799f1035deed1678bb41a4dc573df0d","title":"Reinforced Concrete Column Design per ACI 318-19 §10, §18","path":"/ideCAD/reinforced-concrete-column-design-per-aci-318-19","children":[{"id":"ci_00bd3b393ff29ec353603f2b1b271f4b5f45e763f49cdd2d86e413889b9c166b","title":"Reinforced Concrete Column Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/reinforced-concrete-column-design-limits-per-aci","children":[]},{"id":"ci_158aced47c2e21632796667fe7ba9a0059648e63aaa8a25c802a7bceef297a22","title":"Column Required and Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/column-required-and-design-strength","children":[{"id":"ci_4e2dd8dc96bf8f1bd79a830bba5be3576f355ac9614427a42e3dbd1f55875c4f","title":"Column Combined Flexural and Axial Design per ACI 318-19 with ideCAD","path":"/ideCAD/column-combined-flexural-and-axial-design","children":[]},{"id":"ci_412609333dbbc750600322fbff2bc223dc941e8f628502f84c9aef06cc40ec78","title":"Column Shear Design per ACI 318-19 with ideCAD","path":"/ideCAD/column-shear-design","children":[]},{"id":"ci_0d223b45765b48d6075a17ee8a45fc115865c6850543648bf25547045ce862a6","title":"Minimum Flexural Strength of Columns per ACI 318-19 with ideCAD","path":"/ideCAD/minimum-flexural-strength-of-columns","children":[]}]},{"id":"ci_76c7639456472e76e1c820a9915b6fd18612a31e0e23a64c8da9bae8fd8674dc","title":"Column Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/column-reinforcement-limits","children":[]},{"id":"ci_313e5b21c6e726b16dc2b5e5715f31c8868a93f8042b2611168d1b8ffabd84e5","title":"Column Reinforcement Detailing per ACI 318-19 with ideCAD","path":"/ideCAD/column-reinforcement-detailing","children":[{"id":"ci_704c9988e8551cded37db34edcb3140f855fa8722a57a68b252957e8722fb64c","title":"Longitudinal Reinforcement (CRD) per ACI 318-19 with ideCAD","path":"/ideCAD/longitudinal-reinforcement-crd","children":[]},{"id":"ci_4590eebc501011f6da66f9b2169fb8a003f2532310f6708368b0d0d13fe214fe","title":"Transverse Reinforcement (CRD) per ACI 318-19 with ideCAD","path":"/ideCAD/transverse-reinforcement-crd","children":[]}]},{"id":"ci_37b129037a25885a8c62a7efd41b5f70194f519e3314f279a8db6edc80c4b307","title":"Application of Load Combinations to Modal Response Spectrum Analysis","path":"/ideCAD/application-of-load-combinations-to-modal-response","children":[]}]},{"id":"ci_7307d137610c7df0963aa47f28cba581189919d3f60b467a193533272d3a5f40","title":"Reinforced Concrete Beam Design per ACI 318-19 per ACI 318-19 §9, §18","path":"/ideCAD/reinforced-concrete-beam-design-per-aci-318-19","children":[{"id":"ci_0c5e4e799a26cf91409b60181e9658cbf4f9addb0e34854099798ad7d39aed51","title":"Beam Stability per ACI 318-19 with ideCAD","path":"/ideCAD/beam-stability","children":[]},{"id":"ci_9c40f7b794d963f7673a7c4702c48e21df853b3afac1fe0a5ff50056c22ccdf1","title":"Beam Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/beam-design-limits","children":[]},{"id":"ci_e3eaff68b57890ec67ec51150f1481ee94cd60a15fa867936924f90e23836f52","title":"Beam Required and Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/beam-required-and-design-strength","children":[{"id":"ci_7f7fd8c885f0a712f1f4e373fab23cd750c1363c0a62447d9f0a21b439c7b42a","title":"Beam Flexural Design per ACI 318-19 with ideCAD","path":"/ideCAD/beam-flexural-design","children":[]},{"id":"ci_6bce20c83722643f42e29f7afdf94d8af4be2e523c484ad7a84922e11c1a63ff","title":"Beam Shear Design per ACI 318-19 with ideCAD","path":"/ideCAD/beam-shear-design","children":[]}]},{"id":"ci_6ff7f61848a451053f78e4d1cb6c38247c2b6dc9be9d188b482f2f79b20ff3c6","title":"Beam Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/beam-reinforcement-limits","children":[]},{"id":"ci_740b43aeb3ba4d4c370c4d2d51865dbd340962b1fe11e7ff1aa8af3c5939745b","title":"Beam Reinforcement Detailing per ACI 318-19 with ideCAD","path":"/ideCAD/beam-reinforcement-detailing","children":[{"id":"ci_7856abf29681e478d3541827278a1d0818c907a95200b2401d88c7b91f64ba8c","title":"Flexural Reinforcement (BRD) per ACI 318-19 with ideCAD","path":"/ideCAD/flexural-reinforcement-brd","children":[]},{"id":"ci_38244091a33966a951d8a22df9bdabf9b23e6515924442e5538e762f4951b116","title":"Transverse Reinforcement (BRD) per ACI 318-19 with ideCAD","path":"/ideCAD/transverse-reinforcement-brd","children":[]}]}]},{"id":"ci_6b29ee49bcef5d127d1ea1e7ddd8c37c14a0e251a538eb6cb876574ddfd03819","title":"Concrete Beam-Column Joint Shear Design per ACI 318-19 §15, §18.8","path":"/ideCAD/reinforced-concrete-beam-column-joint-design","children":[{"id":"ci_6ddd430dd1458549e607454059b06bdb2fbb21e61262c1e0cccaa1a1279a528e","title":"Joint Shear Strength per ACI 318-19 with ideCAD","path":"/ideCAD/joint-shear-strength","children":[]},{"id":"ci_d3d7d7ce57f12e26d11ef9cbd604d506e1c2671fe1ce877266a1582a5167eacd","title":"Reinforcement Detailing of Joints per ACI 318-19 with ideCAD","path":"/ideCAD/reinforcement-detailing-of-joints","children":[]},{"id":"ci_014994dd8a2e7996472ea1f6c781d95e09f3e6ad3a2ad81a3e7d08f10b6f28fe","title":"Beam-Column Flexural Capacity Ratios per ACI 318-19 with ideCAD","path":"/ideCAD/beam-column-flexural-capacity-ratios","children":[]}]},{"id":"ci_d1c75010718bf622aee194de45a29a62c465f0b02de63ce597b4f5f7a9405604","title":"Concrete Shear Wall Design per ACI 318-19 §11, §18.10","path":"/ideCAD/concrete-shear-wall-design","children":[{"id":"ci_4d5f9c415b55ba31547bdebde5bf922d5c28ac1f5a46ccd5a352f4d7ee818d70","title":"Shear Wall Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-design-limits","children":[]},{"id":"ci_5f8b1ca90c50c3f7d51d7bf6f2f54b53581465d39fd41f4c83e66f9fe8eb7db8","title":"Shear Wall Required and Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-required-and-design-strength","children":[{"id":"ci_f183e362c7e0d33198a2a40b2636a7b4785fe15c3c7cab9b579639fd388310cc","title":"Shear Wall Combined Flexural and Axial Design per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-combined-flexural-and-axial-design","children":[]},{"id":"ci_c5100ebaf2084cee7d80f94c01ce80d49c0f46c6bcd64d466cf0821d57d7157b","title":"Shear Wall Shear Design per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-shear-design","children":[]}]},{"id":"ci_0552533ed7204360b9b9f3b5715faa04f1a39c8999af26fcd4c640b240842867","title":"Shear Wall Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-reinforcement-limits","children":[]},{"id":"ci_59d7a43c461181c804aa3c9ce68ad4bf4c743a54899836901f4606c9e9929c05","title":"Shear Wall Reinforcement Detailing per ACI 318-19 with ideCAD","path":"/ideCAD/shear-wall-reinforcement-detailing","children":[{"id":"ci_5994760aa3f4ac7587d4bd962509dbc73cef0ae3e5fb0f31f405fc0f02848bd7","title":"Longitudinal Reinforcement (SwRD) per ACI 318-19 with ideCAD","path":"/ideCAD/longitudinal-reinforcement-swrd","children":[]},{"id":"ci_a2d5fc2c8610ad0ce7e9b5f9b908cace537e60d5a8b9a12ec6ee401726d3848c","title":"Transverse Reinforcement (SwRD) per ACI 318-19 with ideCAD","path":"/ideCAD/transverse-reinforcement-swrd","children":[]}]},{"id":"ci_6f983ca75dd4a0db1ef76d5430a902a43b765b0262bfce8dac4baf1c77c5fdf5","title":"Boundary Elements of Special Structural Walls per ACI 318-19 with ideCAD","path":"/ideCAD/boundary-elements-of-special-structural-walls","children":[]},{"id":"ci_271e4ff411b829be581008538256ad45010d5596377a9fa9b69f3b1653a7919f","title":"Coupling Beam Design per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/coupling-beam-design","children":[]}]},{"id":"ci_bb65e930f3e52da659c1e9f66ec1685cdb99430866d6dc6f5d3df59a9c138531","title":"Concrete Slab Design per ACI 318-19 §7, §8","path":"/ideCAD/concrete-slab-design","children":[{"id":"ci_24a805b1618dbe75fddd4a5787e6c6b830f5f1693ce9c647e6ed256ab9a61050","title":"One-Way Slab Design per ACI 318-19 §7","path":"/ideCAD/one-way-slab-design","children":[{"id":"ci_cf8439c243b79f8d216f582e7904d60a107eb91cc4454e2b87fedb83d797d09a","title":"One-Way Slab Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/one-way-slab-design-limits","children":[]},{"id":"ci_5687f1616d36670d9816262cc300e947780400c4fc1fade037888c333474db90","title":"One-Way Slab Required Strength per ACI 318-19 with ideCAD","path":"/ideCAD/one-way-slab-required-strength","children":[]},{"id":"ci_c673cab80e04003941efcf54138aa85f6536b7271813c875c63ecb2a8fef6f5d","title":"One-Way Slab Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/one-way-slab-design-strength","children":[]},{"id":"ci_2df6af5ccf31c7e6e6bb931ff1c53e33427a96f54bff39559baac7ff7ea69710","title":"One-Way Slab Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/one-way-slab-reinforcement-limits","children":[]},{"id":"ci_8e155538fd5d0202e0604304448b9a4ac695eee54f9bd6863ea99a69303c0f62","title":"One-Way Slab Reinforcement Detailing per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/one-way-slab-reinforcement-detailing","children":[]}]},{"id":"ci_4401f1281ae0954ce000a70cc83f6879b8ec5ecd65af19687dc0c6a975fdd54e","title":"Two-Way Slab Design per ACI 318-19 §8","path":"/ideCAD/two-way-slab-design","children":[{"id":"ci_941834b1ce65fb35a79de75f7b237004f5d8b726ee20a38a8c7dfdd50e754455","title":"Two-Way Slab Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/two-way-slab-design-limits","children":[]},{"id":"ci_98f0abcedf12c3f1849b22889a96a251b4279e68cfd3fc64f15c99a726291d18","title":"Two-Way Slab Required Strength per ACI 318-19 with ideCAD","path":"/ideCAD/two-way-slab-required-strength","children":[]},{"id":"ci_a381f8fb1fc8bffc7729dcd2e29bf5e9bce9f47ce50e79323744c3f9384a5d3e","title":"Two-Way Slab Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/two-way-slab-design-strength","children":[]},{"id":"ci_688ad0ef79ca7a02d4890c331dcf532998ac984887ae9997c72ad5988496a730","title":"Two-Way Slab Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/two-way-slab-reinforcement-limits","children":[]},{"id":"ci_22fe9c013636f9ca1066d3ed905232c9feff5bde33558ad0ff99d5bb5ea0671b","title":"Two-Way Slab Reinforcement Detailing per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/two-way-slab-reinforcement-detailing","children":[]}]},{"id":"ci_fd778f14a81f8b6bb0783e68b2d48c2b44f056b8309c0692dcbaf2ddbe059453","title":"Nonprestressed two-way joist systems (Waffle Slabs) per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/nonprestressed-two-way-joist-systems-waffle-slabs","children":[]},{"id":"ci_8df81ca684b44a887f813ae3e7b0cb9505b7da51b58e04a9f5856d69209858cb","title":"Punching Shear Design per ACI 318-19 with ideCAD","path":"/ideCAD/punching-shear-design","children":[]},{"id":"ci_740dcf65806ad9f0d9725ab172df13ce80d2777e8b066c33797b0d2575f3c7f5","title":"Diaphragm Design of the Seismic-Force-Resisting System per ACI 318-19 with ideCAD (v12)","path":"/ideCAD/diaphragm-design-of-the-seismic-force-resisting-sy","children":[{"id":"ci_2984eb7ed51013df849274fc4fa7f85d0f97b096e2e0fde2755ec0d3bf2f9ee0","title":"Diaphragm Design Limits per ACI 318-19 with ideCAD","path":"/ideCAD/design-limits","children":[]},{"id":"ci_cc08da231ffcd7b85efed6362a89a244fde129134f877907670add5971168627","title":"Diaphragm Required Strength per ACI 318-19 with ideCAD","path":"/ideCAD/required-strength","children":[]},{"id":"ci_3883b52345e8cc66cc49dd09b469940e67f4f9739e0859afb34a3b7f919ba9fe","title":"Diaphragm Design Strength per ACI 318-19 with ideCAD","path":"/ideCAD/design-strength","children":[]},{"id":"ci_40e98f5e9c33a32d2ad152876d456159a0351c323c6e1fb78450d4a5bb0c85f6","title":"Diaphragm Reinforcement Limits per ACI 318-19 with ideCAD","path":"/ideCAD/reinforcement-limits","children":[]},{"id":"ci_3e1a0e8546c05cf1f1a1216aca215ff22af1f70cee2fb0486e7e8fd35d1ec456","title":"Diaphragm Reinforcement Detailing per ACI 318-19 with ideCAD","path":"/ideCAD/reinforcement-detailing","children":[]}]}]},{"id":"ci_366d8c2b0b30d4dd765e5309b28a8611f22a08323e1d982f77b386911defc076","title":"Concrete Foundation Design per ACI 318-19 §13","path":"/ideCAD/concrete-foundation-design","children":[{"id":"ci_ed818a7f5b5427bd8e2aaf8aa6b5538cb843cbf61b9c6a242d6c0fb5f1ebf4f1","title":"Shallow Foundation per ACI 318-19 with ideCAD","path":"/ideCAD/shallow-foundation","children":[]},{"id":"ci_eee1892502ad565c897cb1fc3f8be20fb61f4a8d1c08846452b0ed6f446035f9","title":"Deep Foundation per ACI 318-19 with ideCAD","path":"/ideCAD/deep-foundation","children":[]},{"id":"ci_6ab276c4d05071a42d22ab8e7ee01e7faf6de9445a658b718c90286d6ace7e0c","title":"Foundations of Earthquake-Resistant Structures per ACI 318-19 with ideCAD","path":"/ideCAD/foundations-of-earthquake-resistant-structures","children":[]}]},{"id":"ci_437cf1fa6a035260846cf6d5a4e2d50af54419e2f02a45771be40e62895e4c4e","title":"Serviceability per ACI 318-19 §24","path":"/ideCAD/serviceability","children":[{"id":"ci_feb1fdbad209b15d8761d9ae1485fe049a38bb1d6c1ef392fadf7f2bd7919054","title":"Maximum Permissible Calculated Deflections per ACI 318-19 with ideCAD","path":"/ideCAD/maximum-permissible-calculated-deflections","children":[]},{"id":"ci_4fe0dfda88b886627b03a5eed8a9bea07c27b257e1954a6bd41ae485dee1b5d0","title":"Calculation of Immediate Deflections per ACI 318-19 with ideCAD","path":"/ideCAD/calculation-of-immediate-deflections","children":[]},{"id":"ci_63ce3cb98e5ce66d98b24d6d767f431fe0d6362f2ecdd9104bf2fb90ea9fda3d","title":"Calculation of Time-Dependent Deflections per ACI 318-19 with ideCAD","path":"/ideCAD/calculation-of-time-dependent-deflections","children":[]}]}]},{"id":"ci_251339338ce652c123b92285ece2561193cabc397651031076316c0dbd40a893","title":"AISC 360-16 and AISC 341-16 Steel Design","path":"/ideCAD/ansi-aisc-341-16-steel-design","children":[{"id":"ci_d728ca374023d59cbfaeaaff004268f7ece39107ef7cb702f557181fe566c79c","title":"US Materials per AISC 341-16 §A.3","path":"/ideCAD/us-materials","children":[{"id":"ci_baed521c24ea53e0940c6e2e7bf339aa96b4e1fde6e355b399fb880ebbced8b4","title":"Commentary of Expected Strength per AISC 341-16 with ideCAD","path":"/ideCAD/commentary-of-expected-strength","children":[]}]},{"id":"ci_124d3c9e9dd1999979b6d4d89bad1c72be9806797f22b6a6f862e0897b394ff1","title":"General Member and Connection Design Requirements per AISC 341-16 §D1","path":"/ideCAD/general-member-and-connection-design-requirements","children":[{"id":"ci_5843af2b198cc93a7b7c1ea60a815adc18f80497db15e4d1bbbf7ecaed4aa3f4","title":"Classification of Sections for Ductility per AISC 341-16 with ideCAD","path":"/ideCAD/classification-of-sections-for-ductility","children":[{"id":"ci_43e42c3544cf68a9461067058d44ef681ea6d1997ab02b3ce620506f58ea095f","title":"Commentary of Width-to-Thickness Limitations per AISC 341-16 with ideCAD","path":"/ideCAD/commentary-of-width-to-thickness-limitations","children":[]}]},{"id":"ci_4bfe4576414783220bea42c7492cf1c4acb3f3f1d365b5065f715cba9779c13d","title":"Stability Bracing of Beams AISC 341-16 §D2","path":"/ideCAD/stability-bracing-of-beams","children":[{"id":"ci_f76c1483c49bee43389ae3926734bd52b2dc5862ae568b3d77d96e3d5858b9ae","title":"2a. Moderately Ductile Members per AISC 341-16 with ideCAD","path":"/ideCAD/2a-moderately-ductile-members","children":[{"id":"ci_0542c99c65519a201e1978fcbc002fcbe9d6bcd074f80d159571977be7878d02","title":"Commentary of Moderately Ductile Members per AISC 341-16 with ideCAD","path":"/ideCAD/commentary-of-moderately-ductile-members","children":[]}]},{"id":"ci_e2570daaf13da67dfe4ce6cce58bd16522d8b775da75fb9910f44ef40c0c299b","title":"2b. Highly Ductile Members per AISC 341-16 with ideCAD","path":"/ideCAD/2b-highly-ductile-members","children":[{"id":"ci_d8949f9406f85ea67057697fbfe8cffe59edbf29dcbb7e364820a8ce0d0db0b6","title":"Commentary of Highly Ductile Members","path":"/ideCAD/commentary-of-highly-ductile-members","children":[]}]}]}]},{"id":"ci_0a896fb8f04dddde28a4360a3efb31a25911c1af20e81b3bd23f8164082fbe30","title":"Moment Resisting Frame per AISC 341-16 §E","path":"/ideCAD/moment-resisting-frame","children":[{"id":"ci_51cfb00ddb74484c5c22a6a205fe1114dd00e339f29c484ac49b1e7797a82ace","title":"Ordinary Moment Frames (OMF) per AISC 341-16 §E1","path":"/ideCAD/e1-ordinary-moment-frames-omf","children":[]},{"id":"ci_30979866af8429e5a3aad6da6a0a948549c680b5a9551218538ad173cf979a9a","title":"Intermediate Moment Frames (IMF) per AISC 341-16 §E2","path":"/ideCAD/e2-intermediate-moment-frames-imf","children":[{"id":"ci_26ce3a7bd8d4281a6953f1c1d7420ec0aa401610c719f009a74b98fd593d2f2f","title":"Limiting Width-to-Thickness Ratios for Compression Elements for Moderately Ductile Members per AISC 341-16 with ideCAD","path":"/ideCAD/table-d1-1-limiting-width-to-thickness-ratios-for-","children":[{"id":"ci_090a9d31f8c94195916be9b3fec2383d901e3d638bb1ba51159cccd99e7b3753","title":"Width-to-Thickness Ratios for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/width-to-thickness-ratios","children":[]}]},{"id":"ci_802502071ba48df44d956276d8d75013a1c71df0dc5a2cb409c6bad9b78a9ab2","title":"Stability Bracing for Columns and Beams for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/stability-bracing-for-columns-and-beams","children":[{"id":"ci_081ce2b9874149464ed0d02699a19e45b251f71a31651abcfc17e54d76d0fde1","title":"Stability Bracing Control Report for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/stability-bracing-control-report","children":[]}]},{"id":"ci_4b1fa74539de8d0cb05beef742fef46f7b826ec60bc792dc0c6f0570b2010404","title":"Column and Beam Design for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/imf-column-and-beam-design","children":[]},{"id":"ci_f71d5f15ddee397b0110d8a4a55674c457e0916808f59d0a6d6aadc2f1276f8c","title":"Column-Beam Moment Ratio Check for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/strong-column-and-weak-beam-sc-wb-for-imf","children":[]},{"id":"ci_ba67f4a3737ab79527f19ec2618eefcc816519dcbb60e28d2293a5077394401e","title":"Beam-to-Column Connection Requirements for IMF per AISC 341-16 with ideCAD","path":"/ideCAD/beam-to-column-connection-requirements-for-imf","children":[]}]},{"id":"ci_64096399c1a12201eb9c5760c2f0a656b90e6a6d03724bffcb8e4fd32e828ef2","title":"Special Moment Frames (SMF) per AISC 341-16 §E3","path":"/ideCAD/e3-special-moment-frames-smf","children":[{"id":"ci_abdac0f40d2e072c7a22285d45411031585a71bd8e60563d66748768bd5466d8","title":"Width-to-Thickness Ratios for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/width-to-thickness-ratios-for-smf","children":[]},{"id":"ci_1c5e2f77d9588c3bc29c65128386463b83759235630c64dc2bce78dc5763be0c","title":"Stability Bracing for Columns and Beam for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/stability-bracing-for-columns-and-beam-for-smf","children":[{"id":"ci_3ff9044eddbc0866c8fd6bbdbe06fa748945d245d2d457545f7c02a1bc7ff16e","title":"Stability Bracing Control Report for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/stability-bracing-control-report-for-smf","children":[]}]},{"id":"ci_5ae2553ed3ae0d438ba51da1b799658f870d1beba29549b951e9ef6183b4a7ef","title":"Column Required Strength for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/d1-4-column-required-strength-for-smf","children":[{"id":"ci_1b8b73880cd665947b888fe3ac196cdc7e7c7ad6b50bdbb641a954239962cbc5","title":"Column Axial Capacity Control Report for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/column-axial-capacity-control-report","children":[]}]},{"id":"ci_ca9b449f54ad6f0941a16eb6e7febedd72429daa47bfc7c4085cbf7323be99bc","title":"Column and Beam Design for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/internal-forces","children":[]},{"id":"ci_29bffd1cc48ab7dcf845d6cc64e0db90217b1a44a3b5ce787d7df2676ef748d4","title":"Column-Beam Moment Ratio Check for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/4a-moment-ratios","children":[{"id":"ci_1a12ec47cc073b1bfb22b539d9a9151fa65566f985043502d23d7942c097e0e4","title":"Strong-Column and Weak-Beam (SC/WB) Frame Mechanism per AISC 341-16 with ideCAD","path":"/ideCAD/strong-column-and-weak-beam-sc-wb-frame-mechanism","children":[]}]},{"id":"ci_e1fa2bc6b7e5285961208c7ed682eb75da50ba28905c10bc5816be5709808c98","title":"Beam-to-Column Connection Requirements for SMF per AISC 341-16 with ideCAD","path":"/ideCAD/beam-to-column-connection-requirements-for-smf","children":[]}]}]},{"id":"ci_25666cf4f0facee8b4e8da828f6d3bd8df71daa26fc5c5daac8064628706cc96","title":"Concentrically Braced Frames (CBF) per AISC 341-16 §F","path":"/ideCAD/concentrically-braced-frames-cbf","children":[{"id":"ci_1164fb0005b3645c169ebdfc1705f5536ff91f9ea0935cc98784f803e5a6577f","title":"Ordinary Concentrically Braced Frames (OCBF) per AISC 341-16 §F1","path":"/ideCAD/f1-ordinary-concentrically-braced-frames-ocbf","children":[{"id":"ci_9c7ffe785c136d6dcebd6cc7298456a456d449a78146c42f737ede6e480fbc1e","title":"Width-to-Thickness Ratios for OCBF per AISC 341-16 with ideCAD","path":"/ideCAD/width-to-thickness-ratios-report","children":[]},{"id":"ci_33af9a98ad687293c9927f1def9c6ee296b8f8372b45b811da1b70ae4550546a","title":"Column and Beam Design for OCBF per AISC 341-16 with ideCAD","path":"/ideCAD/ocbf-beam-design","children":[]},{"id":"ci_e0e2b66a08d1cabe74a0ba1b7b99d186470fc6c31ebb191c5b8cf36f411ed1a7","title":"Load Combinations for OCBF design per AISC 341-16 with ideCAD","path":"/ideCAD/load-combinations","children":[]},{"id":"ci_cafed08a8f42bb337ace4c609d7040cd2da10d8c37534062bbe892096c6bee9f","title":"Brace Requirements for OCBF per AISC 341-16 with ideCAD","path":"/ideCAD/brace-requirements","children":[{"id":"ci_5269f9f99960bad5b111d21773bfcbb931383c0ba5709b37a77ce4adce46199d","title":"Slenderness Ratio Report for OCBF design per AISC 341-16 with ideCAD","path":"/ideCAD/slenderness-ratio-report","children":[]}]}]},{"id":"ci_b65012a874462f0696d08299ed035abdb1353e2962f05a7a9c5f472324571ebf","title":"Special Concentrically Braced Frames (SCBF) per AISC 341-16 F2","path":"/ideCAD/f2-special-concentrically-braced-frames-scbf","children":[{"id":"ci_36a2a1605f55b55c38307734cb8b0573a47d9b6828b00f451e3e3b65d4c49405","title":"Width-to-Thickness Ratios Report for SCBF per AISC 341-16 with ideCAD","path":"/ideCAD/width-to-thickness-ratios-report-for-scbf","children":[]},{"id":"ci_64e994199fd6989ea80ea66ec8323fc5a46586e06596aebfa3257856ba4de2a2","title":"Analysis for SCBF per AISC 341-16 with ideCAD","path":"/ideCAD/f2-3-analysis","children":[]},{"id":"ci_0c113b1d45acf78404113b9e8a78e4361df37ba4a984158ac7949f373bfb9f40","title":"Internal Forces for SCBF per AISC 341-16 with ideCAD","path":"/ideCAD/internal-forces-for-scbf","children":[]},{"id":"ci_a069e482ebc9d84f3871ea4624e1f123eb2c4443140e4411f3df5043c7b28907","title":"Brace Requirements for SCBF per AISC 341-16 with ideCAD","path":"/ideCAD/concentracialy-brace-frames-requirements","children":[{"id":"ci_477e95418c1e5e3c210f4e099862e5059ed93b7f0d32aa762958046585e5f275","title":"Slenderness Ratio Report for SCBF design per AISC 341-16 with ideCAD","path":"/ideCAD/slenderness-ratio-report-for-scbf","children":[]},{"id":"ci_050fcc0793fd4807487fcba34137d2066b306e1347e2bf1cd87d34cbde05cdde","title":"Ductility Control Report for SCBF design per AISC 341-16 with ideCAD","path":"/ideCAD/ductility-control-report-for-scbf","children":[]}]}]}]},{"id":"ci_5670906248c609b33ebcc2cf31ca06bfd247d67c7b2041733feac1e7f7799f92","title":"Steel Element Design per AISC 360-16","path":"/ideCAD/steel-element-design-according-to-aisc-360-16","children":[{"id":"ci_55ff0cd06c194a57b33b1175983d09184f9cb1139e81a6aa35b13b5ab75efcb4","title":"Design of Steel Members per AISC 360-16","path":"/ideCAD/design-of-steel-members-per-aisc-360-16","children":[{"id":"ci_0c3845ff0c27de504a3488f07ebbcf498ab4304857f81378542c9dd1732b8fc0","title":"Design of Steel Members for Tension per AISC 360-16 §D","path":"/ideCAD/design-of-steel-members-for-tension-per-aisc-360-1","children":[]},{"id":"ci_01a199787c207b3803264fde2de42a54b200e8d3bc76dfea2334cb53eb23e82c","title":"Design of Steel Members for Compression per AISC 360-16 §E","path":"/ideCAD/design-of-steel-members-for-compression-per-aisc-3","children":[{"id":"ci_cfa89a15ee1b98557aae88d97521b3adc8cb618707b3e24fdae4e5010747762e","title":"Flexural Buckling Members without Slender Elements per AISC 360-16 with ideCAD","path":"/ideCAD/flexural-buckling","children":[]},{"id":"ci_1c24b19e947693ade0dca40c75e8c045d73c8f3d016d5cf5ccd423b62a0cb199","title":"Torsional and Flexural-Torsional Buckling of Members without Slender Elements per AISC 360-16 with ideCAD","path":"/ideCAD/torsional-buckling","children":[]},{"id":"ci_47018ca07a4f111e04027ad33640673d1c139771b630fe198fb68b3bfa566842","title":"Steel Members with Slender Elements per AISC 360-16 with ideCAD","path":"/ideCAD/steel-members-with-slender-elements-per-aisc-360-1","children":[]},{"id":"ci_9b1359f87913cc7e7f5d358c496221f3624d79fae74e66782548747ab3e19a8f","title":"Effective Length and Effective Length Factor per AISC 360-16 with ideCAD","path":"/ideCAD/flexural-torsional-buckling","children":[]}]},{"id":"ci_02f16d82df33859dcbae3fb3496141781d69cdf1e9cf78a6ec790201090886a0","title":"Design of Steel Members for Flexure per AISC 360-16 §F","path":"/ideCAD/design-of-steel-members-for-flexure-per-aisc-360-1","children":[{"id":"ci_394dd54788c5ba19955e41570ec7cfa0d379af4b527631dae1e82d200eb48a7d","title":"Doubly Symmetric Compact I-Shaped Members and Channels Flexural Design Bent About Their Major Axis per AISC 360-16 with ideCAD","path":"/ideCAD/i-shaped-members-and-channels-flexural-design-bent","children":[]},{"id":"ci_1082010555db3eaa8d217bfdc34eef3436e527246cf3ddf4eac2e390a1bc1379","title":"Doubly Symmetric I-Shaped Members with Compact Webs and Noncompact or Slender Flanges Bent About Their Major Axis per AISC 360-16 with ideCAD","path":"/ideCAD/doubly-symmetric-i-shaped-members-with-compact-web","children":[]},{"id":"ci_6f3df67bc98527642200a24bffefb85677a9bc6413a8ecff278062bb4a40beb2","title":"I-shaped Members And Channels Bent About Their Minor Axis per AISC 360-16 with ideCAD","path":"/ideCAD/i-shaped-members-and-channels-bent-about-their-min","children":[]},{"id":"ci_c2063b142733259da96bd992b90e362ac4b6eef13b171627ea8d49708ee266d4","title":"Square And Rectangular HSS and Box Sections Flexural Design per AISC 360-16 with ideCAD","path":"/ideCAD/square-and-rectangular-hss-and-box-sections-flexur","children":[]},{"id":"ci_5a471159b7ea98f6a7405ff03787c08c4cf50ad16230f080845262e83448ee54","title":"Round HSS Flexural Design per AISC 360-16 with ideCAD","path":"/ideCAD/round-hss-flexural-design-per-aisc-360-16-with-ide","children":[]},{"id":"ci_7fe96e2a677fae67dfdbe9ba943b293fc35cac04d3e1f9a89af0d115df29cefe","title":"Tees and Double Angles Flexural Design per AISC 360-16 with ideCAD","path":"/ideCAD/tees-and-double-angles-flexural-design-per-aisc-36","children":[]},{"id":"ci_918713c7f6e2ec2d92a1a12863fe585d8ecc739b6536baa415bfc0a272bcf341","title":"Single Angles Flexural Design per AISC 360-16 with ideCAD","path":"/ideCAD/single-angles-flexural-design-per-aisc-360-16-with","children":[]}]},{"id":"ci_30e07b06ad092331ca0fff4650f92460d105c2053d6425145ec338e5bd053428","title":"Design of Steel Members for Shear per AISC 360-16 §G","path":"/ideCAD/design-of-steel-members-for-shear-per-aisc-360-16-","children":[{"id":"ci_ebb74950c5a779bf304d133b00391629ef9bbc0fc2cc7ce279584e8b60f3fafa","title":"I-Shaped Members and Channels Shear Design per AISC 360-16 with ideCAD","path":"/ideCAD/i-shaped-members-and-channels-shear-design-per-ais","children":[]},{"id":"ci_06ce040571df2cdd8defd2270dff49da7f61b4fcbb3cafefeb1bfad3a1fc113c","title":"Single Angles, Tees, Rectangular HSS, Box sections, and other Singly and Doubly Symmetric Members' Shear Design per AISC 360-16 with ideCAD","path":"/ideCAD/single-angles-and-tees-shear-design-per-aisc-360-1","children":[]},{"id":"ci_d2c6f85911d5d54577b32c95dca7a6c139cb63357b223cb94cc0ddbf519f9514","title":"Weak-Axis Shear Design in Doubly Symmetric and Singly Symmetric Shapes per AISC 360-16 with ideCAD","path":"/ideCAD/rectangular-hss-box-sectons-and-other-sngly-and-do","children":[]}]},{"id":"ci_4330699e0ec8f359975e2ff254335d56854331361dc093fb7c9a2c4606bf228b","title":"Design of Steel Members for Combined Forces per AISC 360-16 §H","path":"/ideCAD/design-of-steel-members-for-combined-forces-per-ai","children":[]}]},{"id":"ci_7ac6c249224fc08ae0b336dd206dc166a5fb8ea93a2835fc2ca67f0eec8f5ce2","title":"Structural Steel Column Design per AISC 360-16","path":"/ideCAD/structural-steel-column-design","children":[{"id":"ci_4fa9f96b9f10eef6e623ab4cb29e17de9b79a9c32a2168642c2e12f240262e54","title":"Steel Column Design Settings","path":"/ideCAD/steel-column-design-settings","children":[]},{"id":"ci_10965c6ea4c979b81611ee9a4cfe2e5bfb14380cffb8328bd34abba8759a8fed","title":"Steel Column Design per AISC 360-16","path":"/ideCAD/steel-column-design-aisc-360-16","children":[{"id":"ci_59eeb4f4a943f58cc3f3e0b52a3bc9dc12d5fa0e7c4f84be9a5d8a5fa51b330a","title":"Design of Steel Columns for Combined Forces per AISC 360-16","path":"/ideCAD/design-of-members-for-combined-forces","children":[]},{"id":"ci_0a60194e325c7b24f6ebf8c83135a95d368303dbd302bc2a43afa23264f40ec4","title":"Steel Column Design Example per AISC 360-16","path":"/ideCAD/example-of-column-design-with-aisc-360-16","children":[]}]}]},{"id":"ci_ad242311ba58edde4deac92741f8ff3d152acf9876a335307c8131cf329b03e0","title":"Structural Steel Beam Design per AISC 360-16","path":"/ideCAD/structural-steel-beam-design","children":[{"id":"ci_d88ad2454cea66510cc8851631f3d0f29e538085f94ffba6472eb53bd510b265","title":"Steel Beam Design Settings","path":"/ideCAD/steel-beam-design-settings","children":[]},{"id":"ci_9c93af3080b9b9a257369363efa2ccbd9f2713cae04e9c12a267909b42034c66","title":"Steel Beam Design per AISC 360-16","path":"/ideCAD/steel-beam-design-aisc-360-16","children":[]},{"id":"ci_a6f225ddf51651428ba3da4563469d6d930daaea0e0929ffffa1125b9df648a0","title":"Composite Beams with Steel Headed Stud Design per AISC 360-16","path":"/ideCAD/composite-beams-with-steel-stud-design","children":[{"id":"ci_6a6ca3741e4a0a529f3f476f449444af5832766fe728458e0aa7b81a40a93c9c","title":"Composite Beam Design Example per AISC 360-16","path":"/ideCAD/composite-beam-example-with-aisc-360-16","children":[]}]},{"id":"ci_e61088d20846c574c5f8802d8c7468cc6f872d97b2b9be030af00e36951d3cbe","title":"Castellated Beam Design per AISC 360-16","path":"/ideCAD/castellated-beam-design-with-aisc-360-16","children":[{"id":"ci_671888b5ea5686b3c5ecfb83bd8fa677968e53623c8e0a01b50f4bdf3fbd3843","title":"Castellated Beam Example with AISC 360-16","path":"/ideCAD/castellated-beam-example-with-aisc-360-16","children":[]}]},{"id":"ci_a85c4dae9f7d880cdef3998c48495153156ec863ef4fea160d091128ba056c2e","title":"Composite Castellated Beam Design per AISC 360-16","path":"/ideCAD/composite-castellated-beam-design-with-aisc-360-16","children":[]},{"id":"ci_01db157c08c8a80e1aceb8493fd4fd057a3484823737a007c0cd8f5996cf929e","title":"Crane Beam Design per AISC 360-16","path":"/ideCAD/crane-beam-design-with-aisc-360-16","children":[{"id":"ci_1b0363a986ef0ee71cca4bd4ff56cb57bc5cd7100e1b664346de5c60e6e1b92a","title":"Crane Beam Design Example per AISC 360-16","path":"/ideCAD/crane-beam-design-example-with-aisc-360-16","children":[]}]}]},{"id":"ci_f95d1316224e7e6c00a01c3790383efc539108f1a655eb45722886ab65b7bb7f","title":"Secondary Beam Design per AISC 360-16","path":"/ideCAD/secondary-beam-design-with-aisc-360-16","children":[{"id":"ci_0334799eccaf7085bcf0104195090d14cbba8dcd651433f6fa523d114c5492c7","title":"Steel Secondary Beam Design Settings","path":"/ideCAD/steel-secondary-beam-design-settings","children":[]}]},{"id":"ci_ba83023e3baabfb765ff6575487331feeadce5d6762e6f8a4a50ff812d6d5def","title":"Steel Purlin Design per AISC 360-16","path":"/ideCAD/steel-purlin-design","children":[{"id":"ci_a1a53c2df148d796ade3e5650c6651c04def18445cc00a8bab66f50aaf2e18c7","title":"Steel Purlin Design Settings","path":"/ideCAD/steel-purlin-design-settings","children":[]}]},{"id":"ci_32edc754e20942d5ccceb8f6a35faaca5d2dcab87b24ded697d1efee67c7ece9","title":"Steel Braced Frame Design per AISC 360-16","path":"/ideCAD/steel-concentrically-braced-frames","children":[{"id":"ci_46a09a6bd1c92d5483f91b05808516501375df804fb0e5400e436cbe62254ab3","title":"Braced Frames Design Basis","path":"/ideCAD/concentrically-braced-frames-design","children":[]},{"id":"ci_54b5fe6e2b697034bf6598e7620ada3526ecd5c3117d1d1bac1f535499742852","title":"Design of Braces for Tension per AISC 360-16","path":"/ideCAD/design-of-tension-member-with-aisc-360-16","children":[]},{"id":"ci_7d75b0ae69f253ebd50f4bbb1ca91098d978b2ff5faee943496453721f5e0a98","title":"Design of Braces for Compression per AISC 360-16","path":"/ideCAD/design-with-axial-compressive-force","children":[]}]},{"id":"ci_155497122546ceca4d56040d6dbca7e2f3b5aefb0aa54b64470fd234b28d140b","title":"Structural Steel Truss Design per AISC 360-16","path":"/ideCAD/structural-steel-truss-design","children":[{"id":"ci_62bef66f2b2ecd07d5fde9651d1c23c86479eb4447168afb6815b1b519c90474","title":"Design of Tension Members in Trusses per AISC 360-16","path":"/ideCAD/design-of-tension-members-in-trusses","children":[]},{"id":"ci_3172e259eaa510c411b3d7a2da57c55627044cbed78d5229096f9e8fda39275f","title":"Design of Compression Members in Trusses per AISC 360-16","path":"/ideCAD/design-with-axial-compressive-force-in-trusses","children":[]}]}]}]},{"id":"ci_451e43d01f72ebea24f42d166803970dc5dc8b9ba13b6cc37ec95699681f26bc","title":"Eurocode 3: Steel Design per EN 1993-1-1","path":"/ideCAD/ec-3-steel-design","children":[{"id":"ci_32c5cd2420436ee5b092d0c673f2db7166227bca4d56f49f85a764bbe24368e2","title":"Steel Design per EN 1993-1-1","path":"/ideCAD/steel-design","children":[]},{"id":"ci_92a24a76226d387464a9b20a1a19188ab37469a214c74674d33bdf40c0c61bc7","title":"Classification of cross sections per EN 1993-1-1","path":"/ideCAD/classification-of-cross-sections","children":[]},{"id":"ci_7096b2e2ab4013ff9eb4e1b8ef5b4185a35a8c9d38622f786030898e5c77a8ef","title":"Elastic and Plastic Analysis per EN 1993-1-1","path":"/ideCAD/elastic-and-plastic-analysis","children":[]},{"id":"ci_29f0c7e8015e2404b6db11d5fc74babb9aeacbc2b3d4f630b6c05cb2a7a7fcce","title":"Design of Compression Elements per EN 1993-1-1","path":"/ideCAD/design-of-compression-elements","children":[{"id":"ci_bc6eec80512099c13171c77171e1984ea51650b0f9240b728c8cced375351cc0","title":"Slenderness for Flexural Buckling per EN 1993-1-1","path":"/ideCAD/slenderness-for-flexural-buckling","children":[]},{"id":"ci_5d79cca86fdef9cc995e69e763297efdcc8c356eb1778bf4ac8039ec57a08cfc","title":"Slenderness for Torsional Buckling per EN 1993-1-1","path":"/ideCAD/slenderness-for-torsional-buckling","children":[]}]},{"id":"ci_aae1041749b2abab0feb63fbf8dee0981feceec56f89e7ca11ee6690de86be61","title":"Design of Tension Elements per EN 1993-1-1","path":"/ideCAD/design-of-tension-elements","children":[]},{"id":"ci_fe94ebab0f2e7baf8a3a2b65644fe8c6d00d3633ce4bd5bec9f5602665c5a7ca","title":"Flexural Design per EN 1993-1-1","path":"/ideCAD/flexural-design","children":[]},{"id":"ci_8dfd4155aff0577cc8d367d00a92e76fb24eaf013d53c5ccc8ea4113bd83e72e","title":"Axial Force and Bending Moment Interaction Design per EN 1993-1-1","path":"/ideCAD/design-of-members-for-bending-moment-and-axial-for","children":[]},{"id":"ci_4f03bb21fa4ef47dfb4f5c9c5d9f80859233e74214853d33cd2241a19f3ddc86","title":"Shear Design per EN 1993-1-1","path":"/ideCAD/shear-design","children":[]}]},{"id":"ci_da1b18e983dcc09a7c76fd5b5d3def5b9710b201aa036cf635f5edd63a19f348","title":"EN 1991-1-4 - Wind Actions","path":"/ideCAD/en-1991-1-4-wind-actions","children":[{"id":"ci_7c909eee1d6afd22a8da42a77cee0d564f4e7d1088baea942346c6339a2a759a","title":"Wind Velocity and Velocity Pressure","path":"/ideCAD/wind-velocity-and-velocity-pressure","children":[{"id":"ci_94bdd324589580b679c8355b9fbac89b125f5fb6d85f880b7c5774969cfd6402","title":"Basic Values","path":"/ideCAD/basic-values","children":[]},{"id":"ci_cc9c204db90850cfc94b93526d743380f13ffaf6d103d1bfdc8972af7297a76c","title":"Mean Wind","path":"/ideCAD/mean-wind","children":[]},{"id":"ci_d3a937855de558bc83e354998129d484eb9ed169b5b0977ea0e952e2ce928082","title":"Wind Turbulence","path":"/ideCAD/wind-turbulence","children":[]},{"id":"ci_840093b17d9cca691a12540f4a66acc0dcb3662cc4dbbf4b0dcb2bdb31d52f90","title":"Peak Velocity Pressure","path":"/ideCAD/peak-velocity-pressure","children":[]}]},{"id":"ci_150aeb8927c8a3167eb1c7ef4074096cc6e0e16899d9623edfb87561e6569609","title":"Wind Actions","path":"/ideCAD/wind-actions","children":[{"id":"ci_93af5ba6c5c230bf69127675c2a19de192a7a3b1cc04bb5a708632d2d14184ad","title":"Wind Pressure and Wind Forces","path":"/ideCAD/wind-pressure-on-surfaces","children":[]}]},{"id":"ci_d480222ee2ed40e25f9e830a23abecc7dc3591777fbec6fa90eebfd9f0226eb9","title":"Pressure and Force Coefficients","path":"/ideCAD/pressure-and-force-coefficients","children":[{"id":"ci_ad9350e9fdba3c645eb11af83fc5ae5c4b8305de367d120e4bdd835d0f258a36","title":"Vertical Walls of Rectangular Plan Buildings","path":"/ideCAD/vertical-walls-of-rectangular-plan-buildings","children":[]},{"id":"ci_aced0f91e1d75299804ac5f47c79b8d5e721368ea328016502f999f9e200b3df","title":"Monopitch Roofs - Wind Pressure Coefficients","path":"/ideCAD/monopitch-roofs-wind-pressure-coefficients","children":[]},{"id":"ci_e48c04b30ed34fe0adec19eef6ca34e629ef6589539e0cd6c7e52c0bf047cd00","title":"Duopitch Roofs - Wind Pressure Coefficients","path":"/ideCAD/duopitch-roofs-wind-pressure-coefficients","children":[]}]}]},{"id":"ci_89c4a75429a5eda25d0ac2ef8e8f3dfee8a122a826389c9903baacde036504bb","title":"Connection Design per AISC 360-16 & AISC 358-16","path":"/ideCAD/aisc-360-16-connection-design","children":[{"id":"ci_93214cb95d365b347d5402881dd384db60bfa5f8a286c9f519a79fe8130875b3","title":"Geometry Control for Connection Design per AISC 360-16","path":"/ideCAD/geometry-control-for-connection-design-with-aisc-3","children":[]},{"id":"ci_17fea191406333adc7500f3784750c759e98901ee91b02e0f29b1830481a465c","title":"Shear Connections per AISC 360-16","path":"/ideCAD/shear-connections-with-aisc-360-16","children":[{"id":"ci_ff391d7a2981586ff8e1573b6f488b11f6fac0faa6780d27cc14156b98e93378","title":"Connection Design Subject to Shear per AISC 360-16","path":"/ideCAD/connection-design-under-shear","children":[]},{"id":"ci_dae9614b4812a5b9d79645d6aedbddfdd03eebf2b93fce92e8f00813209e3128","title":"Single Plate Connection Design per AISC 360-16","path":"/ideCAD/single-plate-connection-with-aisc-360-16","children":[{"id":"ci_4ece30f05177fa4ec5b56712a9be7d268cf13be0b284d6e2b7781136375688bb","title":"Single Plate Design Report","path":"/ideCAD/single-plate-design-report","children":[]}]},{"id":"ci_8c4ea3243a9260a59ac6470f9050b4f47abca9b08292d89541b90e5935c916fb","title":"Single Angle Connection Design per AISC 360-16","path":"/ideCAD/single-angle-connection-with-aisc-360-16","children":[{"id":"ci_02d4c0d14778d2924a6321e5314c0b06146872248fafec4c54315f6ba885fe6d","title":"Single Angle Design Report","path":"/ideCAD/single-angle-design-report","children":[]}]},{"id":"ci_53c081463db2d2d75ec59d571fff0ecb8fd4674b4064123f1a533abad410ccff","title":"Double Angle Connection Design per AISC 360-16","path":"/ideCAD/double-angle-connection-with-aisc-360-16","children":[{"id":"ci_478551627931999ba968affb8ddfa58354ee5001d43436ca9af83ba41c36bac3","title":"Double Angle Connection Design Report with AISC 360-16","path":"/ideCAD/double-angle-connection-design-report-with-aisc-36","children":[]}]},{"id":"ci_71c446b5c50d1288e2df83b5127111ab9e56a5ef8f66a9f371adaf5d3f007a3f","title":"T-Plate Connection Design per AISC 360-16","path":"/ideCAD/t-plate-connection-1","children":[{"id":"ci_f9e11ebbe41daa730358534ce9c569438765b594a5f3baed7b5673407c10aaf6","title":"T-Plate Connection Design Report","path":"/ideCAD/t-plate-connection-design-report","children":[]}]},{"id":"ci_839aec71ba4eba0cc4d489b5bb413c6a57e8e928ff49984067b4e08daa897aef","title":"End Plate Shear Connection Design per AISC 360-16","path":"/ideCAD/end-plate-shear-connection-with-aisc-360-16","children":[{"id":"ci_d0dd96c3d87cf75fb60a53376e479091277a492e794bbd42815cacdf3389b6d0","title":"End Plate Shear Connection Design Report","path":"/ideCAD/end-plate-shear-connection-design-report","children":[]}]},{"id":"ci_8bd1324172bd7de06a02019a04d1835e2538c95e385b1f04c8dc6cb6e79a63f3","title":"Unstiffened Seated Connection Design per AISC 360-16","path":"/ideCAD/unstiffened-seated-connection-with-aisc-360-16","children":[{"id":"ci_58d24dedbfdc26c2f3f8bb986ce88e9ebfe843699985e4e8489227f232b98535","title":"Unstiffened Seated Connection Design Report","path":"/ideCAD/unstiffened-seated-connection-design-report","children":[]}]}]},{"id":"ci_c280620b6f752d4a843445aef26c8add53f6169be6808b32ba2192d0584f51cf","title":"Moment Connections Design per AISC 360-16 & AISC 358-16","path":"/ideCAD/moment-connections-design","children":[{"id":"ci_51717895b825beb4aa5657dc40b83a6f424cccdabea32a7da05e320948b5b08a","title":"Design Rules of Moment Connections per AISC 358-16 & AISC 360-16","path":"/ideCAD/design-rules-of-moment-connections","children":[]},{"id":"ci_b15f720829d8148d32b559a5e52ddaadc0065ad5137e5f5be8b160b4b214caf4","title":"End Plate Connections per AISC 358-16 & AISC 360-16","path":"/ideCAD/end-plate-connections-with-aisc-358-16","children":[{"id":"ci_fc3c630a6eafd8b8105c65d380b9db701c4858c90099673bad09bc10c93ccb8e","title":"4 Bolts Unstiffened End Plate Connection per AISC 358-16 & AISC 360-16","path":"/ideCAD/4-bolts-unstiffened-end-plate-connection-1","children":[{"id":"ci_64cc57f737970aab584d1ff048a2390f1801f0b41b38b38fa41bfb02a41e169e","title":"4 Bolts Unstiffened End Plate Connection Design per AISC 358-16 & AISC 360-16","path":"/ideCAD/4-bolts-unstiffened-end-plate-connection-design","children":[]},{"id":"ci_8bc9e8999bddffe0605ad78677fe08a77b19cc653d4460ebe9786010389ff8f8","title":"4 Bolts Unstiffened End Plate Connection Report","path":"/ideCAD/4-bolts-unstiffened-end-plate-connection-report-1","children":[]}]},{"id":"ci_fc3151473934611c78d7c3c163275fbd6126447ed0dfac5e62e4f1fa361917ec","title":"4 Bolts Stiffened End Plate Connection per AISC 358-16 & AISC 360-16","path":"/ideCAD/4-bolts-stiffened-end-plate-connection","children":[{"id":"ci_9d8c9e9cf39587dbbe36a887b493288db61840b4189c0e45c1f8d9993f80c2ac","title":"4-Bolts Stiffened End Plate Connection Design per AISC 358-16 & AISC 360-16","path":"/ideCAD/4-bolts-stiffened-end-plate-connection-design-1","children":[]},{"id":"ci_89c01ed010b310dd79cdc3b1798c2f330e4fe7dc514b311964f075bd213616ba","title":"4-Bolts Stiffened End Plate Design Report","path":"/ideCAD/4-bolts-stiffened-end-plate-design-report","children":[]}]},{"id":"ci_c3b266f3b092ab55d3b05e8779ae9cc589189f41c8e7ae3008cf916e1f6f5376","title":"8-Bolts Stiffened End Plate Connection per AISC 358-16 & AISC 360-16","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-1","children":[{"id":"ci_adeb7177638e835f13c7af7bac155347ddc8527f491a3764dbbf677128787933","title":"8-Bolts Stiffened End Plate Connection Design per AISC 358-16 & AISC 360-16","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-design-1","children":[]},{"id":"ci_fa7e29aa9f6b2ee8877d380bbc6a65d1d1d7ce35326b7fb02800c7f193cd2343","title":"8-Bolts Stiffened End Plate Connection Report 1","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-report-1-1","children":[]}]}]},{"id":"ci_35332fb8f465bdb277d22cef9360b732abae4cce6e6a53a3065a0fb453da7884","title":"Bolted Flange Plate Connections per AISC 358-16 & AISC 360-16","path":"/ideCAD/bolted-flange-plate-connections","children":[{"id":"ci_39797fb062a51a477679e0bb4045f9e10bc9f3a4521e5f0c3b34861ce80de6b4","title":"Bolted Flange Plate Connection Design per AISC 358-16 & AISC 360-16","path":"/ideCAD/bolted-flange-plate-connection-design-with-aisc-35","children":[]},{"id":"ci_8d7a835e4256c6b58a7f5be61d24fc0f9a696a93ee8b4957a973933b05fe72f7","title":"Bolted Flange Plate Connection Design Report 1","path":"/ideCAD/bolted-flange-plate-connection-design-report-1","children":[]}]},{"id":"ci_1e7dc3b2988d7d2437dbe6988668a69f0371b2a6e02200c3be956018c8678b3d","title":"Welded Flange Plate Connection per AISC 360-16","path":"/ideCAD/welded-flange-plate-connection-with-aisc-360-16","children":[{"id":"ci_0c8bad66a1a3f2c0ed265bd6bca5da4823c9316a823975375cc995f2456a7239","title":"Welded Flange Plate Connection Design per AISC 360-16","path":"/ideCAD/welded-flange-plate-connection-design-with-aisc-36","children":[]},{"id":"ci_264773d6163b97e1e6768521eaf67e94f61ae7bedf38d799a6de7d7fbf6fc62a","title":"Welded Flange Plate Connection Design Report","path":"/ideCAD/welded-flange-plate-connection-design-report","children":[]}]},{"id":"ci_0eadb05f464329a6fa5d797ff4e709f1c40445e92723b12b027254764fc056f6","title":"Welded Web Connection (WUF-W Moment Connection) per AISC 358-16 & AISC 360-16","path":"/ideCAD/welded-web-connection-wuf-w-moment-connection","children":[{"id":"ci_8097e28e834b466e54ca282bde6169370677a7541de78fb6884955c17f49ba37","title":"Welded Web Moment (WUF-W) Connection Design per AISC 358-16 & AISC 360-16","path":"/ideCAD/welded-web-wuf-w-moment-connection","children":[]},{"id":"ci_18075103a620f5d5a2987bbc339646a5059aca1f70671d50f829148fafeb414c","title":"Welded Web Connection (WUF-W Moment Connection) Design Report","path":"/ideCAD/welded-web-connection-wuf-w-moment-connection-desi","children":[]}]},{"id":"ci_2da425d8c85516753d0852a39c0ef9344a8df3f448c8e83280f5b65a8d53a9ae","title":"Joining Plates Design per AISC 360-16","path":"/ideCAD/joining-plates-design","children":[{"id":"ci_2a4459c065c801e6e02fad2e434a2181420955a4ad8828c36572af23bc4d59ba","title":"Joining Plates Design Report","path":"/ideCAD/joining-plates-design-report","children":[]}]},{"id":"ci_04a14b6778e49a40768fa7a3f9107aba0f3356eaa6c28b5074e262146aa88940","title":"Splice Connection per AISC 360-16","path":"/ideCAD/splice-connection-with-aisc-360-16","children":[{"id":"ci_21e6e152f4f03f89672f22095f245303a6c1877db6e7ebd0f553fefcf9f24998","title":"Splice Connection Design per AISC 360-16","path":"/ideCAD/splice-connection-design-with-aisc-360-16","children":[]},{"id":"ci_218287215375155aa3efcae01219c5f6ea5c9ebdedf37db1e7bde1eee5a447d5","title":"Splice Connection Design Report","path":"/ideCAD/splice-connection-design-report","children":[]}]}]},{"id":"ci_83e7488e6c24735366e61c89ecc92d5960cf71dfa503679d4922527e46852ef5","title":"Brace Connection Design per AISC 360-16","path":"/ideCAD/brace-connections","children":[{"id":"ci_0decd8ec8c5aa06c3d0dac055c06eb927197c3be65e53cfbf768d2458200d23f","title":"Brace-Corner Connections","path":"/ideCAD/brace-corner-connection-1","children":[{"id":"ci_6da0379897571db0ea4d7e016dfb582cc24bca17f959cd42354dab50d123dfcf","title":"Brace-Corner Connection Design per AISC 360-16","path":"/ideCAD/brace-corner-connection-design-1","children":[]},{"id":"ci_709fe975880612864661005b5078162968dc1365330526cfc61e0fe76fae79e1","title":"Brace-Corner Connection Design Report","path":"/ideCAD/brace-corner-connection-design-report","children":[]}]},{"id":"ci_fd0adf2808a219684190f124406e06ac9c542dc909335f96d5ed33805c784ade","title":"Brace-Center Connection","path":"/ideCAD/brace-center-connection-1","children":[{"id":"ci_c3146b34f69cf7d41c1e89b8924053690ba699a53abc4b51e74f090e7f7a70dd","title":"Brace-Center Connection Design per AISC 360-16","path":"/ideCAD/brace-center-connection-design-1","children":[]},{"id":"ci_ae22afe4a6ca00528b122907a11c5e927bc90d3612b099434fbf51c3ba956984","title":"Brace-Center Connection Design Report","path":"/ideCAD/brace-center-connection-design-report","children":[]}]}]},{"id":"ci_12ccc04b8206f683f95f4882fae5cfba0af80a4ce0acb4550a48fc024e121282","title":"Column-Foundation Connection (Stiffened Baseplate) per AISC 360-16","path":"/ideCAD/column-foundation-connection-stiffened-baseplate","children":[{"id":"ci_c5e34f3a604ad8eeae28a07e265bf569e8e865d35287d347c318742389a81bb6","title":"Column-Foundation Connection (Stiffened Baseplate) Design per AISC 360-16 & Design Guide 1","path":"/ideCAD/column-foundation-connection-stiffened-baseplate-d","children":[]},{"id":"ci_46da5accb73928b4d5741bce0570d73c3186e65b915ebe6eb4f2d60f875b1f54","title":"Column - Foundation Connection (Stiffened Baseplate) Report","path":"/ideCAD/column-foundation-connection-stiffened-baseplate-r","children":[]}]}]},{"id":"ci_3c4bc986a235a5d4193d2587749eaf67d68de289bf1aee4a72b65731ee225a25","title":"TSC 2018","path":"/ideCAD/tsc-2018","children":[{"id":"ci_7d6399717da57894f2c644a4611bc898460afdedb156f6b66b1b3c04b2a988c7","title":"Earthquake Ground Motion","path":"/ideCAD/earthquake-ground-motion","children":[{"id":"ci_baf02b1b569f18289d7d209ddf2b87071e1124ae77ad175f48b594f4a04d96c0","title":"Earthquake Ground Motion Levels","path":"/ideCAD/earthquake-ground-motion-levels","children":[]},{"id":"ci_13bd0b409459608d60d3d5653eb87b6655d492937ef0785f576deb1af76e65b1","title":"Spectral Response Acceleration Parameters.","path":"/ideCAD/spectral-response-acceleration-parameters","children":[]},{"id":"ci_6060cfba1b595a770ec759b35c55d0f7603e448165fef437fca2e74ff8840f98","title":"Site Class and Site Coefficients","path":"/ideCAD/site-class-and-site-coefficients","children":[]},{"id":"ci_ce67001daec34ca1f317c1759a25fdbb711a08128c2d01a638016beead3d1630","title":"Horizontal Design Response Spectrum","path":"/ideCAD/horizontal-design-response-spectrum","children":[]},{"id":"ci_4a8fc73ece23853d887f5b9edc89874c983b1112afced1e935843dc83d8ee6ff","title":"Vertical Design Response Spectrum","path":"/ideCAD/vertical-design-response-spectrum","children":[]},{"id":"ci_86c8d50466ac17a8dbd824d3de791b9009bd6e018b7d7e3626de8a90b9f8dc9a","title":"Design Spectrum for Site-Specific Ground Motion","path":"/ideCAD/design-spectrum-for-site-specific-ground-motion","children":[]},{"id":"ci_8ac8a9fe68fe709e6cd1f1de3dfcc22bf03c42a824a652db58f098027d699806","title":"Earthquake Ground Motion Records in Time History","path":"/ideCAD/earthquake-ground-motion-records-in-time-history","children":[]}]},{"id":"ci_57570c5a6741ec53b92faa4f2972ee6d218c91b28a71d2f273ee45a306b1315c","title":"General","path":"/ideCAD/general","children":[{"id":"ci_6049e00c4998f07f5212b55b2fe869d4ec763db71db9ff62465b99aae5692b30","title":"TSC-2018 Building Importance Categories and Building Importance Factors","path":"/ideCAD/tsc-2018-building-importance-categories-and-buildi","children":[{"id":"ci_2803810258fc560217b598dc16a0201b9e05e01bc095972c2e924a1b2b44995a","title":"Building Importance Category Selection  (3.1.2)","path":"/ideCAD/building-importance-category-selection-3-1-2-1","children":[]}]},{"id":"ci_b82956a5b9c440cab4644dc66e7d6028e39dcb421d1f9fcee282740f7f3c24d9","title":"TSC-2018 Seismic Design Category","path":"/ideCAD/tsc-2018-seismic-design-category","children":[]},{"id":"ci_f91b05d791b7a60217a50eb24783f6f2c530171181450dd38f3015a353542f9a","title":"TSC-2018 - Building Base and Building Height","path":"/ideCAD/tsc-2018-building-base-and-building-height","children":[{"id":"ci_2e51c33d9a0a0a653b75479ef5cc3aa2b3a84b975eddf1342ee7e4a11bb5cd20","title":"TSC-2018 - Period Requirement for Structures Including Rigid-Basement Floors (3.3.1)","path":"/ideCAD/tsc-2018-period-requirement-for-structures-includi","children":[]}]},{"id":"ci_7a8e900a6111f544deec5fde5f4874beee5093694dc64c2dbef29b3735e58aab","title":"TSC-2018 - Building Height Category","path":"/ideCAD/tsc-2018-building-height-category","children":[]},{"id":"ci_54950fed5b6b5a3e8d14f52efb0bf64e21b0dfa0c604d7093f2192481f7e8c29","title":"TSC-2018 - Building Performance Levels","path":"/ideCAD/tsc-2018-building-performance-levels","children":[{"id":"ci_9736d16d6e86db72c6fadbd5d5241ab09fc32ec4e265ccc06739ef84add7993e","title":"TSC-2018 - Building Performance Levels (3.4)","path":"/ideCAD/tsc-2018-building-performance-levels-3-4","children":[]}]},{"id":"ci_a9881672e20891ff0bdebe65244ab3fcd9315f1a68a0e8cc373e371f4b35d880","title":"TSC-2018 - Building Performance Requirements","path":"/ideCAD/tsc-2018-building-performance-requirements","children":[{"id":"ci_f4acf9ac9c43025939847108575a8396365aa4d8d7df8ac97a6584b52a61e569","title":"TSC-2018 - Building Performance Requirements (3.5.1)","path":"/ideCAD/tsc-2018-building-performance-requirements-3-5-1","children":[]}]},{"id":"ci_6ff9a07584bdd8fc2a120eaccf9a2b432c2222af993667136e31fa69ce8a167c","title":"TSC-2018 - Requirement / Design Assumptions","path":"/ideCAD/tsc-2018-requirement-design-assumptions","children":[{"id":"ci_3d185209258849a750d23f7513fb6e96140d3dbd0ffc5d4ce53311fbd2a034a1","title":"TSC-2018 - Requirement / Design Assumptions (3.5.2)","path":"/ideCAD/tsc-2018-requirement-design-assumptions-3-5-2","children":[]}]}]},{"id":"ci_dc9cec8d647ca4e84e836cd5afbe0535f2182373c0103ee001094fc907e8a534","title":"Ultimate Strength Design Principles (USD)","path":"/ideCAD/ultimate-strength-design-principles-usd","children":[{"id":"ci_eb0d09200c78fe2b0d1ac3efeb9a1e7ec2356d48d5e05c99a270d09c2ec53501","title":"Response Modification Coefficient (R)","path":"/ideCAD/response-modification-coefficient-r","children":[{"id":"ci_bfbc453f49f38cc0facc042b9db975f611aa81110656a4bd586067b133161119","title":"Appendix-4A Explanation","path":"/ideCAD/appendix-4a-explanation","children":[{"id":"ci_70f4725df4c0a6a790a8208acb49ce6125ff0768df17b4be26831c2f0ec4124c","title":"Detailed Explanation (Appendix-4A)","path":"/ideCAD/detailed-explanation-appendix-4a","children":[]}]}]},{"id":"ci_7fc67076470424bca1a52300200d09173f283e296cde5ac3fd11cc822afd21bb","title":"R and D Coefficients For Seismic Force-Resisting Systems","path":"/ideCAD/r-and-d-coefficients-for-seismic-force-resisting-s","children":[{"id":"ci_8e3c71435934bdfa55819b915f16cd8c8eca418f55a058ee96a81b64e7035625","title":"Seismic Force-Resisting System Selection (4.3.2.1)","path":"/ideCAD/seismic-force-resisting-system-selection-4-3-2-1","children":[]},{"id":"ci_fe28f7b0f0ab5aba38a601a94eaced33cd135aecbc228eeb2961d75dd22dd563","title":"Structures with Basement (4.3.2.3)","path":"/ideCAD/structures-with-basement-4-3-2-3","children":[]},{"id":"ci_efed2ed8f056008011e8e8f03351104895f7aebdbda46d065c0a55a15517d9b8","title":"For DTS = 1, 1a, 2, 2a (4.3.2.4) Structures with Reinforced Concrete Shearwalls and/or Steel Braced Frames","path":"/ideCAD/for-dts-1-1a-2-2a-4-3-2-4-structures-with-reinforc","children":[]}]},{"id":"ci_b239f647b15ec032aa088c7a159cf204e858d5e6cb0d12f5c1187812cd8c6a3a","title":"Conditions Regarding Ductility Levels of Structural Systems","path":"/ideCAD/conditions-regarding-ductility-levels-of-structura","children":[{"id":"ci_a4b3dd58fa39883107bcef527098c435568ad9b21d3aac88e316c273f791e2a5","title":"Nominal Ductility Level and Mixed Ductility Level (4.3.4.1)","path":"/ideCAD/nominal-ductility-level-and-mixed-ductility-level-","children":[]},{"id":"ci_466ada1798d9373f25e6d0c546942c52a5cb83533cee0f9fcc62bad31fa880e0","title":"Structural Systems for Perpendicular Directions (4.3.4.2)","path":"/ideCAD/structural-systems-for-perpendicular-directions-4-","children":[]},{"id":"ci_56a8d213cfe63e4bdfadada4ead23be3097f85ee1ddebfe47ccec167e54294ed","title":"Ribbed Slab Type Systems (4.3.4.3)","path":"/ideCAD/ribbed-slab-type-systems-4-3-4-3","children":[]},{"id":"ci_d94d07ff5c323335aae9cc654a2331eada6c406c9af69b6bcf4346d93649fa75","title":"Structural Systems Including Non-beam Slabs (4.3.4.4)","path":"/ideCAD/structural-systems-including-non-beam-slabs-4-3-4-","children":[]},{"id":"ci_7702a13ebf19fde1af46b9c83b45c28e5929b93d131fbd4246a6f4eb716e6521","title":"Overturning Moment Condition for Shearwalls (4.3.4.5)","path":"/ideCAD/overturning-moment-condition-for-shearwalls-4-3-4-","children":[]},{"id":"ci_09fe40da0abad5a5c2d9b237cd2ce1633950fcd6a3fffa4308ed46b47ce8ce01","title":"Overturning Moment Condition (0.75) for Shearwalls (4.3.4.6)","path":"/ideCAD/overturning-moment-condition-0-75-for-shearwalls-4","children":[]},{"id":"ci_e0472818330b8b4190e2e2f2a38d0d89648ac1a00987ddb959c9e1ac5a2c3319","title":"Structural Systems with Nominal Ductiliy Level Shearwall and Moment Frames (4.3.4.7)","path":"/ideCAD/structural-systems-with-nominal-ductiliy-level-she","children":[]},{"id":"ci_7756d6fa9398c18396738227bf234311d3dc6818b2e87d82c02048641244183a","title":"Overturning Moment of Shearwalls (4.3.4.8)","path":"/ideCAD/overturning-moment-of-shearwalls-4-3-4-8","children":[]},{"id":"ci_4dd81b1447c6a96144df833129da2cdfeebe00190a4daeb3c75452fb10761123","title":"Shearwall Length of Vertical Wall Segment / Wall Thickness (Hw/lw ≤ 2.0) Condition (4.3.4.9)","path":"/ideCAD/shearwall-length-of-vertical-wall-segment-wall-thi","children":[]},{"id":"ci_1c6ff26c84d490be100d4fb70887857fbcb9582fae50cd3475521b714c0419eb","title":"Reinforced Concrete Shearwalls in Basement Stories (4.3.4.10)","path":"/ideCAD/reinforced-concrete-shearwalls-in-basement-stories","children":[]}]},{"id":"ci_2db6da2513cb4aa13d9bd4f9136ef2117677bcb3ad305178917e3cd6edc1aa0f","title":"Application of Overstrength Factor","path":"/ideCAD/application-of-overstrength-factor","children":[{"id":"ci_2f18aad9dfe1a59f2830249ba7bdfd5a14d4dfc8a8f69b6581429e4f565b1396","title":"Overstrength Factor (4.3.5.1)","path":"/ideCAD/overstrength-factor-4-3-5-1","children":[]},{"id":"ci_767ca701755382b520d5f9321328d2317581e8820b4cf043279bdd9c78b3061a","title":"Internal Force Corresponding to Ductile Behavior (4.3.5.2)","path":"/ideCAD/internal-force-corresponding-to-ductile-behavior-4","children":[]},{"id":"ci_975ee2b0898bbd84885da6d65694468f8b818b03cdae7e6f2752dfc4dd191f6a","title":"Internal Force Corresponding to Brittle Behavior (4.3.5.3)","path":"/ideCAD/internal-force-corresponding-to-brittle-behavior-4","children":[]},{"id":"ci_4ba0f5fcae58b3887da4d67e6a6fd7717b37b8b79f48c37b797207372590d582","title":"Application of Overstrength Factor (4.3.5.4)","path":"/ideCAD/application-of-overstrength-factor-4-3-5-4","children":[]},{"id":"ci_a6de63975dec83a229201e6610bc16940b7f668510c537c0b5defabd3bddd02c","title":"Application of Overstrength Factor for Slabs (4.3.5.5)","path":"/ideCAD/application-of-overstrength-factor-for-slabs-4-3-5","children":[]},{"id":"ci_2fb7faafe6f4930c0717eadbbc7ef6594339ac4ae69c38b70ae6e85f0c0a05b1","title":"Overstrength Factor for Exterior Basement Walls in Structural System Elements (4.3.5.6)","path":"/ideCAD/overstrength-factor-for-exterior-basement-walls-in","children":[]},{"id":"ci_a808f704697d99f60df3555fe8ff273a801d14dae5a8e125b1da8a38d4f25222","title":"Overstrength Factor for Internal Forces Acting on Foundations  (4.3.5.7)","path":"/ideCAD/overstrength-factor-for-internal-forces-acting-on-","children":[]}]},{"id":"ci_943e8413e3f8b83ce53a8b3459f965d28cd1851df02c58808c44be46c52a012f","title":"Use of Different R and D Coefficients for Upper and Lower Pats of Structures with Basement","path":"/ideCAD/use-of-different-r-and-d-coefficients-for-upper-an","children":[{"id":"ci_24fd8947cf7adeb3b1db532ac36edd4ef4656fc5f26349b3dac1048d3f26ed3a","title":"Modal Response Spectrum Analysis of Structures with Basement (4.3.6.2)","path":"/ideCAD/modal-response-spectrum-analysis-of-structures-wit","children":[]}]},{"id":"ci_2386fc7dab618788a8e77fc6f6b2140bee7b2481e452220652c5f62386cdc9fd","title":"Reduced Design Response Spectrum","path":"/ideCAD/reduced-design-response-spectrum","children":[{"id":"ci_e5a88ec02c5d267cbe52f21411cad96e5a7afc3cd75489429fa0045304383c21","title":"Design Spectrum Reduced by Respose Modification (4.4.1)","path":"/ideCAD/design-spectrum-reduced-by-respose-modification-4-","children":[]}]},{"id":"ci_325debb7282cd297f2bd71ef89c8da7b2f80431f3b76282f911ced18ece51095","title":"Combination of Earthquake Effects for Perpendicular Directions","path":"/ideCAD/combination-of-earthquake-effects-for-perpendicula","children":[{"id":"ci_7570d7a225543bf7ac0a0d490c03a052e3e844551a4bfd730bbecd4dc805d4ba","title":"Load Combinations of Earthquake Effects for Perpendicular Directions (4.4.2.1)","path":"/ideCAD/load-combinations-of-earthquake-effects-for-perpen","children":[]},{"id":"ci_cc6d28274264c54012dd944a8d675168368b790ae6b054f9fd91f54f39f709c3","title":"Combination of Perpendicular Directions for Time History Analysis (4.4.2.2)","path":"/ideCAD/combination-of-perpendicular-directions-for-time-h","children":[]}]},{"id":"ci_69cdfe44807aaf0105bd722849b87f13d2cb8f531f5aa843af6b50aa573be65e","title":"Vertical Earthquake Effects","path":"/ideCAD/vertical-earthquake-effects","children":[{"id":"ci_29d9c94d322309aca0b6d11ad20bf6d4ab36feae93caaa12bcf010de406d623d","title":"Vertical Seismic Response Spectrum Analysis (4.4.3.1)","path":"/ideCAD/vertical-seismic-response-spectrum-analysis-4-4-3-","children":[]},{"id":"ci_f78f71ac2d03c1a2aee7a6021e95ae55413549d5cfcdcbfe29b23a006d12f645","title":"Approximate Vertical Earthquake Effects","path":"/ideCAD/approximate-vertical-earthquake-effects","children":[]}]},{"id":"ci_31a234bc7e62b575045953c9a7f4138c70aa78dce3b151bc430465548947398f","title":"Basic Combinations (Dead, live or other loads) with Seismic Load Effects.","path":"/ideCAD/basic-combinations-dead-live-or-other-loads-with-s","children":[{"id":"ci_117f11fc4bd515c24d6b9882e47b3dc08d4c9412c283861d3d740ca739a6fc40","title":"Load Combinations with Seismic Load Effects (4.4.4.1)","path":"/ideCAD/load-combinations-with-seismic-load-effects-4-4-4-","children":[]},{"id":"ci_c673becc6c1299cc5b067578aae2486d65f70e71c6dbe442ed0268f79dc29091","title":"Load Combinations for Steel and Cold-Formed Steel Buildings (4.4.4.2)","path":"/ideCAD/load-combinations-for-steel-and-cold-formed-steel-","children":[]}]},{"id":"ci_c70eeaf935eabf24e3f62f520925cd3f36a2168637a697117bf479bc407cf200","title":"Structural Modeling Criteria for USD","path":"/ideCAD/structural-modeling-criteria-for-usd","children":[{"id":"ci_106c239d0b5710f1b9a81117813d9681e9dfae745b0bc2282b2787901608c1d5","title":"Structural Modeling (4.5.1.1)","path":"/ideCAD/structural-modeling-4-5-1-1","children":[]},{"id":"ci_bf348507b9ca02e6248fd0ad87838c86c0361a490d6aced9c90e5f9578e43508","title":"Earthquake Effects on Perpendicular Horizontal Directions (4.5.1.2)","path":"/ideCAD/earthquake-effects-on-perpendicular-horizontal-dir","children":[]},{"id":"ci_b5f651878ae8b0c0401495cec8d47ca6ef9cff3edfd9262fd95f5b0ff98b07e7","title":"Damping ratio (4.5.1.3)","path":"/ideCAD/damping-ratio-4-5-1-3","children":[]},{"id":"ci_69f500e109714d36a62a527855f65c2554f590b34799d07ddd284d5137286afc","title":"Structural Modeling for Non-Seismic Effects (4.5.1.4)","path":"/ideCAD/structural-modeling-for-non-seismic-effects-4-5-1-","children":[]}]},{"id":"ci_558ff7f90715a57362e2d7e96049184469b27af4df8863c6d452d17a08f127f9","title":"Beam and Column Modeling","path":"/ideCAD/beam-and-column-modeling","children":[{"id":"ci_dcd0a1bc8d349887f0805688475c85d7045eaed20e07a9bab13f0b73a8fbdcdd","title":"Finite Elements - Frame Element (4.5.2.1)","path":"/ideCAD/finite-elements-frame-element-4-5-2-1","children":[]},{"id":"ci_642ac29f9561a92089cce0abea518caa1b0d10d5d0013bea2b3523e870db3ae0","title":"Effective Stiffness for Reinforced Concrete Columns and Beams (4.5.2.2)","path":"/ideCAD/effective-stiffness-for-reinforced-concrete-column","children":[]}]},{"id":"ci_3591f3653ae9f740b66bef8ab7265497e7f62fbeead669c22630c238da736631","title":"Shearwall Modeling","path":"/ideCAD/shearwall-modeling","children":[{"id":"ci_027b6dcb12703301900eaf48624f6b9fb0abdf4074f2a31649f499614b5fbe89","title":"Rectangular Cross-section Walls (4.5.3.2)","path":"/ideCAD/rectangular-cross-section-walls-4-5-3-2","children":[]},{"id":"ci_fac5abf9eebbb810ca753a8e7d05dbcf12847a4d2fae80272261ecd4bcdc50b4","title":"Polygonal Cross-Section Walls (4.5.3.3)","path":"/ideCAD/polygonal-cross-section-walls-4-5-3-3","children":[]},{"id":"ci_51767cba5e0e331e8d9d532f74b4058ecd5ffdcdeaeb34b15d755e26c27f29cb","title":"Shear Wall Modeling with Finite Elements Mesh (4.5.3.4)","path":"/ideCAD/shear-wall-modeling-with-finite-elements-mesh-4-5-","children":[]},{"id":"ci_9aae185f0d06930ea6a5f313f8136908aea3579327adf4f6eac120cbfa0428b1","title":"Finite Element Mesh Modeling of Polygonal Cross-section Shear Walls as a Whole (4.5.3.5)","path":"/ideCAD/finite-element-mesh-modeling-of-polygonal-cross-se","children":[]},{"id":"ci_8155009d1408dca276b2d9f76a527d2e17d3ea3b98d4101c0a06002d97037d00","title":"Finite Element Meshes of Shear Wall (Shell Elements) (4.5.3.6)","path":"/ideCAD/finite-element-meshes-of-shear-wall-shell-elements","children":[]},{"id":"ci_fb13cdb8b8fa04a89cbfc25768afdab5c88fdabce4d6f3cf42ae45b36897d026","title":"Finite Element Meshes of Polygonal Cross-section Shear Wall (Shell Elements) (4.5.3.7)","path":"/ideCAD/finite-element-meshes-of-polygonal-cross-section-s","children":[]},{"id":"ci_af428b88ab153532c4b7218f6329be64ca12cee1e8fe2954a632251a2f8138cc","title":"Equivalent Internal Forces of Polygonal Cross-section Walls (4.5.3.7 (d))","path":"/ideCAD/equivalent-internal-forces-of-polygonal-cross-sect","children":[]},{"id":"ci_ad636486efeac314cc7151ea98db86cd3fac7c5ccdd741f45fa059f98d6d9341","title":"Shear Wall Modelling with Frame Elements  (4.5.3.8)","path":"/ideCAD/shear-wall-modelling-with-frame-elements-4-5-3-8","children":[]}]},{"id":"ci_1a2ece4460095dc3c3cc7970da4c0d72aa03d798e6403d8428aab86865bb4ffd","title":"Coupling Beam and Coupled Shearwall Modelling","path":"/ideCAD/coupling-beam-and-coupled-shearwall-modelling","children":[{"id":"ci_08f476951cb14da67f5e949a3f75bb3e6ec9c9fdbcfc7a71e2a122d7951b69aa","title":"Definition of Walls with Coupling Beam (4.5.4.1)","path":"/ideCAD/definition-of-walls-with-coupling-beam-4-5-4-1","children":[]},{"id":"ci_0bda5ebe0c10b68dfbae140a898c417edc90b21f9edbd0bb8c5a514368b86c28","title":"Overturning Moment of Walls with Coupling Beam (with Space) (4.5.4.3)","path":"/ideCAD/overturning-moment-of-walls-with-coupling-beam-wit","children":[]},{"id":"ci_794952bfec0c921be685d1570e7b7f4748b5a705916b436dd80683b82ad95772","title":"Coupling Ratio of Coupled Walls (4.5.4.4)","path":"/ideCAD/coupling-ratio-of-coupled-walls-4-5-4-4","children":[]},{"id":"ci_24fcf2ff7d1858cdc9284845ff9ca4c07775361f31e008c1295bf0d64c051d0b","title":"Coupled Wall Criteria (4.5.4.5)","path":"/ideCAD/coupled-wall-criteria-4-5-4-5","children":[]},{"id":"ci_fe821aded9373a911c907d0f26f4197d49b0db13ecfd0e1bdce8673f18956fce","title":"Coupled Walls Modeling Criteria  (4.5.4.6)","path":"/ideCAD/coupled-walls-modeling-criteria-4-5-4-6","children":[]},{"id":"ci_56b9432b9936adf6a8cb6103cdbf660f6034ce8a5a946c0fbd242bb98ecab7da","title":"Coupling Beam Modeling Criteria (4.5.4.7)","path":"/ideCAD/coupling-beam-modeling-criteria-4-5-4-7","children":[]}]},{"id":"ci_ba74418b6b1885572e4443e577d165b75103dee5a13a96afb9c643db96f7f5b0","title":"Basement Wall Modeling","path":"/ideCAD/basement-wall-modeling","children":[{"id":"ci_6459cec23cf32ec25ae4f33b870a24d3f05fafc11746af08431753a6bf2919d7","title":"Basement Wall Modeling Criteria (4.5.5.2)","path":"/ideCAD/basement-wall-modeling-criteria-4-5-5-2","children":[]}]},{"id":"ci_a8eb553795b2aa70ac43d02555b1741726851e43a414d75ff0855b370e74b8cf","title":"Slab Modelling","path":"/ideCAD/slab-modelling","children":[{"id":"ci_21b85f3d9ceaa2f4530e3492164b0011a70031d79d6f71b5b844b48dde262a77","title":"Slabs (4.5.6.1)","path":"/ideCAD/slabs-4-5-6-1","children":[]},{"id":"ci_13c0950af8750745e63ed9cfe86e2738a1d8a68a0cd8d8964666002e34abb831","title":"Irregularitiy Types A2 and A3 (4.5.6.2)","path":"/ideCAD/irregularitiy-types-a2-and-a3-4-5-6-2","children":[]},{"id":"ci_a5a473a75822ac50601504ec30f491b7de447caa61fe53bf0cbc4cc25791db62","title":"Rigid Diaphragm Conditions (4.5.6.3)","path":"/ideCAD/rigid-diaphragm-conditions-4-5-6-3","children":[]},{"id":"ci_ddd511c2080b0bf723b03b6a91037eac18ea25f85bdfe3fe96b19d9ac6b8a7b4","title":"Transfer of In-Plane Diaphragm Forces to Seismic-Force-Resisting Elements (4.5.6.5)","path":"/ideCAD/transfer-of-in-plane-diaphragm-forces-to-seismic-f","children":[]}]},{"id":"ci_dbf856dfd788f39f564d4578abb9c54f7fc79482d52833061c517bc454d3f2d7","title":"Slabs Modelling of Basement Transfer Stories","path":"/ideCAD/slabs-modelling-of-basement-transfer-stories","children":[{"id":"ci_6c1e6bedc08769e55f92406cbae3b92c052106230749983acf952734f83bb87d","title":"Slabs Modelling of Basement Transfer Stories (4.5.7.2)","path":"/ideCAD/slabs-modelling-of-basement-transfer-stories-4-5-7","children":[]},{"id":"ci_c0856563a048ce7e0b16942b6251b9e6544bdab80b49cad01c5df9a8da13b836","title":"Forces Acting on Basement Shear Walls (4.5.7.3)","path":"/ideCAD/forces-acting-on-basement-shear-walls-4-5-7-3","children":[]}]},{"id":"ci_89dbcc73f4ce4c96c09291799b41cbaf33b5a4f64b53b1a5c054249ba9f05ef9","title":"Effective Section Stiffness","path":"/ideCAD/effective-section-stiffness","children":[{"id":"ci_64384442f2fc3b9858080561598f23c2a289d3d1f183cd287d65f6401a79e3e8","title":"Stiffness Multipliers Usage in Accordance Table 4.2 (4.5.8)","path":"/ideCAD/stiffness-multipliers-usage-in-accordance-table-4-","children":[]}]},{"id":"ci_a8c383d96fb522b01fc2ff9a841354ff04a728616607958c55f66eaf6e63f20a","title":"Mass Definition in Structural Modelling","path":"/ideCAD/mass-definition-in-structural-modelling","children":[{"id":"ci_f1063c5071ef01b7bc002b51f05d5c031eabf120c1c2b9281a6dc5ac924e8504","title":"Mass Definition at Joints (4.5.9)","path":"/ideCAD/mass-definition-at-joints-4-5-9","children":[]}]},{"id":"ci_86759d3e72d2e05e729427e886f88d5cf5aabc9159eb8d88d5660d3d1d3924fb","title":"Additional Eccentricity Modelling","path":"/ideCAD/additional-eccentricity-modelling","children":[{"id":"ci_1dc44110d869771a0cfbca846225ca86815c6bfcebfbafbff4dc9630f12cef7b","title":"Offsetting the Center of Mass (4.5.10)","path":"/ideCAD/offsetting-the-center-of-mass-4-5-10","children":[]}]},{"id":"ci_1cb4e1115b2804a1f14996219cdf6e2b02a14759cad15b201fd3a6e440c2e00a","title":"Linear Earthquake Analysis Procedure Selection","path":"/ideCAD/linear-earthquake-analysis-procedure-selection","children":[{"id":"ci_fde8f62b49ea741ec8eb86fd4bbf15518e957e58fb0b39f16d89218c4e529fc1","title":"Modal Response Spectrum Analysis and Linear Response History Analysis (4.6.2.1)","path":"/ideCAD/modal-response-spectrum-analysis-and-linear-respon","children":[]},{"id":"ci_30903011c962b14bfb0421f6eabef07edb1d37332bf837e47f05e0acf1e87fb5","title":"Equivalent Lateral Force Conditions (4.6.2.2)","path":"/ideCAD/equivalent-lateral-force-conditions-4-6-2-2","children":[]}]},{"id":"ci_f3cb5dc665f7adf81d7bdcb81880723bfcd7fa36febc36f2185f310ae1d598ea","title":"Equivalent Lateral Force Method","path":"/ideCAD/equivalent-lateral-force-method","children":[{"id":"ci_9cf6a0d51e3a0d47a7361d33646d1520867dbde2c437765b5636b6c2ebdaa417","title":"Determination of Total Equivalent Seismic Base Shear (4.7.1)","path":"/ideCAD/determination-of-total-equivalent-seismic-base-she","children":[]},{"id":"ci_0bfca7418434c0c93b6a789759dc965d9e9e7dc1a0d119316a7c9ec05c01f61a","title":"Vertical Distribution of Seismic Forces (4.7.2)","path":"/ideCAD/vertical-distribution-of-seismic-forces-4-7-2","children":[]},{"id":"ci_ae2c68c6ee51a33d57dcaf9b41a8fb1aebf764c0b9de8e9592a86f441acf70dd","title":"Natural Fundemantal Period Determination  (4.7.3)","path":"/ideCAD/natural-fundemantal-period-determination-4-7-3","children":[]},{"id":"ci_37c80327de7eea0e43d85a74beaebce8b85daa45e13cc868fc7bdabf9f7e9767","title":"Seismic Analysis Using Equivalent Lateral Force Method for Structures with Basement (4.7.5)","path":"/ideCAD/seismic-analysis-using-equivalent-lateral-force-me","children":[]}]},{"id":"ci_e4f6c31e70602d4777ae0ea3abd0babe024aaafed4064e49524370a2c0720aa1","title":"Linear Dynamic Analysis","path":"/ideCAD/linear-dynamic-analysis","children":[{"id":"ci_5a83cfbb750c83658a65d50b61aec7468c29b26f0d0692f1be39a33ddc9f44f3","title":"Combined Response Parameters / Enveloping of Force Response Quantities (4.8.1)","path":"/ideCAD/combined-response-parameters-enveloping-of-force-r","children":[]}]},{"id":"ci_1998a6b046219b39875fee34e5e47d6d65d6c1c4ceb623a2579aa9a10d2ece47","title":"Modal Response Spectrum Analysis","path":"/ideCAD/modal-response-spectrum-analysis","children":[{"id":"ci_6fada1704189fe0abfca120aa9ce95f6d42abfe3841d85b597465ca9b788599a","title":"Calculation of Combined Response Parameters and Scaling Design Values of Combined Response (4.8.2.1)","path":"/ideCAD/calculation-of-combined-response-parameters-and-sc","children":[]},{"id":"ci_2d7896f24caca7c25d120e02eeac634ef2ba087feca3fd005ee6daea937fff96","title":"Mode Shapes and Modal Vibration Periods","path":"/ideCAD/mode-shapes-and-modal-vibration-periods","children":[]},{"id":"ci_bf222ce61d35c4a665490b2efe1d56b2d0a6688af4bad9efb081ec9ebce5605f","title":"Modal Additive Multiplier and Base Shear Modal Effective Mass","path":"/ideCAD/modal-additive-multiplier-and-base-shear-modal-eff","children":[]},{"id":"ci_8261c1e8751f5b53c7e77d7fecaba525172aed5e26b9acb7c1711ef238ff5b6d","title":"Modal Effective Masses and Modal Mass Participation Rates","path":"/ideCAD/modal-effective-masses-and-modal-mass-participatio","children":[]},{"id":"ci_468cc298959e7a5bc19a83eb722d38ae01f87180de091cfb62ee488fd33090cd","title":"Unit Modal Behavior and Maximum Modal Behavior Sizes","path":"/ideCAD/unit-modal-behavior-and-maximum-modal-behavior-siz","children":[]},{"id":"ci_4e7b93a59fc04c1b1ae5a134777939373b8f41c56940190decb78558b1cc99aa","title":"Mode Combination Method with Perfect Quadratic Combination (TKB, CQC)","path":"/ideCAD/mode-combination-method-with-perfect-quadratic-com","children":[]}]},{"id":"ci_6ac9114ff80d81f8377eacf8d4083024b2a102ec597aa5744bc64a8a1174e57f","title":"Mode Addition Method in Time Domain","path":"/ideCAD/mode-addition-method-in-time-domain","children":[{"id":"ci_c95a2d18feb66c83c187d089d92452bd99bb089f6c541e0118eb3db0a53c9f22","title":"Mode Addition Method Application in Time Domain (4.8.3)","path":"/ideCAD/mode-addition-method-application-in-time-domain-4-","children":[]}]},{"id":"ci_81a55c28e3cb433b4d0d81d399eadef54d745750503cd77b10d4093cd27083c5","title":"Base Shear Scale Factor","path":"/ideCAD/base-shear-scale-factor","children":[{"id":"ci_22c63796802fdff940a41f9ffc9d310947113c99184fd75090487a1154bbadfe","title":"Determination of Base Shear Scale Factor (4.8.4.1)","path":"/ideCAD/determination-of-base-shear-scale-factor-4-8-4-1","children":[]}]},{"id":"ci_fe77c85be941e574b0eab4083d7e8f8391c5f8303abc1d79add95122e73e8d65","title":"Modal Response Spectrum Analysis of Structures with Basement","path":"/ideCAD/modal-response-spectrum-analysis-of-structures-w-1","children":[{"id":"ci_1c76dbbcee00f1ab1d184477c70f274e52bf054c01a70a3c67f8f3c917e767e5","title":"Internal Forces of Upper and Lower Part Elements with Modal Response Spectrum Analysis of Structures with Basement (4.8.5)","path":"/ideCAD/internal-forces-of-upper-and-lower-part-elements-w","children":[]}]},{"id":"ci_c1a6e489ac310d9e9fc643a24cb9fead9bc076b4b59b7dba4760ddbd2183c3a0","title":"Limits of Story Dritfs","path":"/ideCAD/limits-of-story-dritfs","children":[{"id":"ci_ad832cb46b9104ef0067886f1c78dc9484cd5d3e991a86bf8455745a42e2cb48","title":"Story Dritf Determination for Columns and Walls (4.9)","path":"/ideCAD/story-dritf-determination-for-columns-and-walls-4-","children":[]},{"id":"ci_c97ea9cdd18c917fe1ca2eca18b6ee6662b11dbcdc01719253375d731cbeb44d","title":"Story Drift Limits Report","path":"/ideCAD/story-drift-limits-report","children":[]},{"id":"ci_6eb7e8f6f3fba56ef365f18a5b94e6880d0b57fb600d5dfd6133ae2b8938adc4","title":"Story Drift Example","path":"/ideCAD/story-drift-example","children":[]},{"id":"ci_ad6350743480b4cbf60390dec42623ea2851aa2312b22daf28e19b9b9537e200","title":"Example 1 for Lamda Coefficient used in Story Drift Determination","path":"/ideCAD/example-1-for-lamda-coefficient-used-in-story-drif","children":[]},{"id":"ci_1663af925726f1b731324d3759dfd11b366c1d48297dde5c2406e9b7c0ce350a","title":"Example 2 for Lamda Coefficient used in Story Drift Determination","path":"/ideCAD/example-2-for-lamda-coefficient-used-in-story-drif","children":[]},{"id":"ci_712fc1c9a2797734439b9cfc1ec8992d9e5f7f4f7568159942087d8070afe8b1","title":"Example 3 for Lamda Coefficient used in Story Drift Determination","path":"/ideCAD/example-3-for-lamda-coefficient-used-in-story-drif","children":[]}]},{"id":"ci_64d1096217e55ccff9388b42781608778d34e21af1493abfa56a19c801664a5d","title":"Second-Order Effects","path":"/ideCAD/second-order-effects","children":[{"id":"ci_cbbc5cbeb9c7d8ac2ba7051d2d8c17075ec9f0df0282329b1651e8158c58e644","title":"Second Order Effect Coefficient (4.9.2)","path":"/ideCAD/second-order-effect-coefficient-4-9-2","children":[]}]},{"id":"ci_dd8b919e22dc31f06553e2fc7716c2ec95dd89fbd3f5000675818e1df958f576","title":"Internal Design Force of Elements of Building with Basement","path":"/ideCAD/internal-design-force-of-elements-of-building-with","children":[{"id":"ci_190a6b9730d6ff0a6f688abb6fd4fb0cf9424ec7e277d8a59a25a6b8ae00a1e9","title":"Determination of Element Internal Force Upper and Lower Parts of Structures with Basement (4.10.1)","path":"/ideCAD/determination-of-element-internal-force-upper-and-","children":[]}]},{"id":"ci_ddac9a2a10c2d36cf13b47cd86dd8140c6c6471e5e17e5f40f51c3ef181f4194","title":"Internal Design Force of Elements of Building without Basement","path":"/ideCAD/internal-design-force-of-elements-of-building-wi-1","children":[{"id":"ci_94457f2af7260dbe3e55904838b77dddd8c2ae7026f2f7970d5ac16a4e2ff95f","title":"Determination of Element Internal Force of Structures without Basement","path":"/ideCAD/determination-of-element-internal-force-of-structu","children":[]}]},{"id":"ci_60543838ad8c890ce71e49368fec9528114e17f692d9d4c52da05411f8fda870","title":"Internal Forces Acting on Foundations","path":"/ideCAD/internal-forces-acting-on-foundations","children":[{"id":"ci_1b425ac8072f1265582d859ad1b91741030c5ba0c53f7d1ec4ea03813ae1c96d","title":"Determination of Internal Forces Acting on Foundations (4.10.3)","path":"/ideCAD/determination-of-internal-forces-acting-on-foundat","children":[]}]}]},{"id":"ci_43db1d5e76aa688fc24b053a3c4b81a36e98a485b5c5faf00a3023c3281daebe","title":"Concrete Element Design","path":"/ideCAD/concrete-element-design","children":[{"id":"ci_77179a20f5cf5ec421d7974d1e685b392f2beedffd5631969c85be31670ed3d7","title":"TSC Sectional Strength","path":"/ideCAD/tsc-sectional-strength","children":[{"id":"ci_27532e22ad353907070d0dab729e88bc12635e94c351a33274b28bf60474c68f","title":"TSC Flexural Strength","path":"/ideCAD/tsc-flexural-strength","children":[]},{"id":"ci_1405b1873125ac1fd06517432ad1e5b47bcd2a2a26a67b95db07ced51ad503b5","title":"TSC Axial strength or Combined Flexural and Axial Strength","path":"/ideCAD/tsc-axial-strength-or-combined-flexural-and-axial-","children":[]},{"id":"ci_4e7f8b7629ef859c663cb6c7c4ea7923a4c5876bb7aeb27a2dbb7404138b83a2","title":"TSC One-Way Shear Strength","path":"/ideCAD/tsc-one-way-shear-strength","children":[]},{"id":"ci_c9836d85c2e087c57b615f3f07fa6901cdc34c7bc4284d04af2b6ad72f24ee2f","title":"TSC Torsional Strength","path":"/ideCAD/tsc-torsional-strength","children":[]}]},{"id":"ci_ce4050ad2f3783d201fc0a885c4be03c8847d1116a452dcbfdd8a0acb08cf003","title":"TSC Reinforcement Details","path":"/ideCAD/tsc-reinforcement-details","children":[{"id":"ci_68f1b8c77588754d70920dd32001a5c55c26bcc4a238ed8267c2e1a141abf2e3","title":"TSC Minimum Spacing of Reinforcement","path":"/ideCAD/tsc-minimum-spacing-of-reinforcement","children":[]},{"id":"ci_77780fd5042326bf0fb53f70626803e79293a13df9a7b0f547a62a23cf80d1d3","title":"TSC Standard Hooks, Seismic Hooks, Crossties, and Minimum Inside Bend Diameters","path":"/ideCAD/tsc-standard-hooks-seismic-hooks-crossties-and-min","children":[]},{"id":"ci_508344e0d30103e1f51dc2c4eafdddcf2d533a6143da56c34d7fb0abcd6b9e15","title":"TSC Development of Reinforcement","path":"/ideCAD/tsc-development-of-reinforcement","children":[]},{"id":"ci_79d3e5ecd8a8b03277b62735b4bcf04d353a84215d071cbc9cdf768593ed769a","title":"TSC Splices","path":"/ideCAD/tsc-splices","children":[]}]},{"id":"ci_557b152222b7d7c1f4ad34127b037cd758198fa01353ab45ddfde1399586165a","title":"Column Design.","path":"/ideCAD/column-design-1","children":[{"id":"ci_d52c40f3ae1751f3e59190b0424c36cd051803eff03b29f3345fa85a47313d24","title":"Dimensional Limits for Columns","path":"/ideCAD/dimensional-limits-for-columns","children":[{"id":"ci_0be27c5ae81c6d7de13572129c92b11f94d1f7fadd1f037fc0d0f7f9d333701b","title":"Column Axial Force Control","path":"/ideCAD/column-axial-force-control","children":[]},{"id":"ci_533b6b7c2c31ceffba276211c8d29de47c40dab413adfd67067b14373fd5a02b","title":"TS500 - Axial Force and Moment","path":"/ideCAD/ts500-axial-force-and-moment","children":[]},{"id":"ci_a20b5d21669c555031ec35928175bfc68c6cbf6d85e64c851182836d60718d54","title":"Column Axial Force Report","path":"/ideCAD/column-axial-force-report","children":[]},{"id":"ci_8168f3fc05911554f21b3567be3bcf2fe0674469094d49214b84574bc5ab1db7","title":"Column Axial Force Control Example","path":"/ideCAD/column-axial-force-control-example","children":[]}]},{"id":"ci_30ab3c98db6a403c1819819d43872f4bfb40ad78727cb15be841e92bec689a43","title":"Longitudinal Reinforcement Detailing for Columns","path":"/ideCAD/longitudinal-reinforcement-detailing-for-columns","children":[{"id":"ci_b760af77f65460ae20436be0d51649acaf8b61c952e5bc40caefd8c2bb96385f","title":"Column Longitudinal Reinforcement Detailing","path":"/ideCAD/column-longitudinal-reinforcement-detailing","children":[]},{"id":"ci_1392fff2c281251b70556352c0f02ab217428e6c0f5cf8360cca94395721b9cc","title":"Column Longitudinal Reinforcement Reports","path":"/ideCAD/column-longitudinal-reinforcement-reports","children":[]},{"id":"ci_6afe7d838e4e8b361c9f64de1f5be5ab36492366ecfe3cd39f3dd68fc0b6ac1b","title":"Longitudinal Reinforcement Sample Calculation","path":"/ideCAD/longitudinal-reinforcement-sample-calculation","children":[]}]},{"id":"ci_012d9492a54cbc1ac05148483324689235f252f3db851c8bb51db32a610c979e","title":"Transverse Reinforcement Detailing for Columns","path":"/ideCAD/transverse-reinforcement-detailing-for-columns","children":[{"id":"ci_bce54ba433a3d0fd98640788c6b24f9a0d883f8e3a914589be650e6e9e0d8c1c","title":"Column Transverse Reinforcement Detailing and Limits","path":"/ideCAD/column-transverse-reinforcement-detailing-and-limi","children":[]},{"id":"ci_4803bcc7956e35279e713eb2008e8ef538662367dc173f9ac5b4c5ec46978030","title":"TS500 - Column Transverse Reinforcement Conditions","path":"/ideCAD/ts500-column-transverse-reinforcement-conditions","children":[]},{"id":"ci_767355525ee2819308b7d81e92129c5fdbb9905af435875715c9b51c8e5dbb7c","title":"Column Transverse Reinforcement Reports","path":"/ideCAD/column-transverse-reinforcement-reports","children":[]},{"id":"ci_09c9dfb7b650623d70d607784109176af9d68ebe43ec9932d63ec269a1ae1745","title":"Column Transverse Reinforcement Sample Calculation","path":"/ideCAD/column-transverse-reinforcement-sample-calculation","children":[]}]},{"id":"ci_05818a8985c3c6537754a820a781736d18c198671dd9f81e1f9db52737161dfb","title":"Shear Strength of Columns","path":"/ideCAD/shear-strength-of-columns","children":[{"id":"ci_e06795b24ccaead3d0119887a1165142b15d849b756d45f1117f54112de99dd4","title":"Column Shear Design Forces","path":"/ideCAD/column-shear-design-forces","children":[]},{"id":"ci_c91201fa6b8872d0b27896023ca7f3b9ead1e98d27b83dc26d0008766b5c089a","title":"TS500 - Maximum Design Shear Force Condition","path":"/ideCAD/ts500-maximum-design-shear-force-condition","children":[]},{"id":"ci_1b6fe4709ff8f2ac4a8d2bdfdc42733e49becb1d899dc323c032134993962a4b","title":"Column Shear Design Report","path":"/ideCAD/column-shear-design-report","children":[]},{"id":"ci_b2badd59942962eb800cfc079189a09853f679b14ef252c3079ca570f6818202","title":"Column Shear Design Force Example","path":"/ideCAD/column-shear-design-force-example","children":[]}]},{"id":"ci_35174fdd6694ce90a863fdd82779b7a5da65f55fc1b6130d6237418f3fc5a241","title":"Strong Column Condition","path":"/ideCAD/strong-column-condition","children":[{"id":"ci_8d9f6f0be545012cd7f35c2ed2a1507a09eaace61442574c3a4f2e248ec1e0e1","title":"Conditions for Columns to be Stronger than Beams (Strong columns)","path":"/ideCAD/conditions-for-columns-to-be-stronger-than-beams-s","children":[]},{"id":"ci_3503ed536530197c1d3075e44612a7e698837d21fd54822aad10ccdcce68b0cc","title":"Strong Column Condition Reports","path":"/ideCAD/strong-column-condition-reports","children":[]},{"id":"ci_29138d93ded0b3224f25623dcccf1c6b66312abef7002fff2dd126a00e15eca1","title":"Strong Column Condition Example","path":"/ideCAD/strong-column-condition-example","children":[]}]},{"id":"ci_c433bd3ec2711e169414eff421216d8f8687cfaca9500de1fad2001d837ac60e","title":"Axial Force Biaxial Moment Calculation for Load Combinations in Modal Response Spectrum Analysis","path":"/ideCAD/axial-force-biaxial-moment-calculation-for-load-co","children":[]},{"id":"ci_fc6a38121bb7feec226d32c5d02ab50a8543a52bc74659b4f3a976ea2e23ef88","title":"Axial Force and Biaxial Moment Interaction for Columns","path":"/ideCAD/axial-force-and-biaxial-moment-interaction-for-col","children":[]}]},{"id":"ci_fcaf350f075c20cd1ea96732cd96e1f26d5ec8914e9d09414f4dfd770258498f","title":"Beam Design.","path":"/ideCAD/beam-design-1","children":[{"id":"ci_3887d9ddf7c18800e014be44c8a08d7416d3ae52daa2d6890396f6c8e492d790","title":"Dimensional Limits for Beams","path":"/ideCAD/dimensional-limits-for-beams","children":[{"id":"ci_eb6e2bcf48adb852bf4ffe0547c5e75b53e03c490882b20a5a48b63d26d5722d","title":"Dimensional Limit Conditions for Beams","path":"/ideCAD/dimensional-limit-conditions-for-beams","children":[]}]},{"id":"ci_deb1b7fa4233155bb1cb0fb34c59ba63dbdd2de035b6e92b4291117b7ff94d5c","title":"Longitudinal Reinforcement Limits and Detailing for Beams","path":"/ideCAD/longitudinal-reinforcement-limits-and-detailing-fo","children":[{"id":"ci_e09103b875865deb28bfe224dbc27f7dcda6bff6f2103d4b7652b6d1c152c21b","title":"Longitudinal Reinforcement Limits for Beams","path":"/ideCAD/longitudinal-reinforcement-limits-for-beams","children":[]},{"id":"ci_8cad5ca494b4d00d9b28e276996788e90e29cea34983659185a2e3dbe66fa205","title":"Longitudinal Reinforcement Detailing for Beams.","path":"/ideCAD/longitudinal-reinforcement-detailing-for-beams","children":[]}]},{"id":"ci_ea0bb717b8d37f47674dde6dc34cde6da29d1ee7e9cd2f823723083a93149d68","title":"Transverse Reinforcement Detailing for Beams","path":"/ideCAD/transverse-reinforcement-detailing-for-beams","children":[{"id":"ci_fe302e5f9e71894f9cf3dd5d6a2c438d935c900f607ec085941640b765c6bf27","title":"Transverse Reinforcement Detailing for Beams.","path":"/ideCAD/transverse-reinforcement-detailing-for-beams-1","children":[]}]},{"id":"ci_d4935cda349e02047075b03d94715b4ff7505a6a786c5004d626c7e291ec565a","title":"Shear Strength of Beams","path":"/ideCAD/shear-strength-of-beams","children":[{"id":"ci_cb2e64d82c39a233d51bbac41da6feffa4c8b2d7bc1eb490dd8e305d06a0db43","title":"Beam Shear Design Force","path":"/ideCAD/beam-shear-design-force","children":[]},{"id":"ci_fa23c06ed28f81ae66f179c330f480fbe3c33a81442617a1423a647e16e81385","title":"Beam Shear Design Report","path":"/ideCAD/beam-shear-design-report","children":[]},{"id":"ci_c517ed8c7c770252ba3afbbc3ea8f5a491964137010cc925e2d820ff5dd58356","title":"Beam Shear Design Examples","path":"/ideCAD/beam-shear-design-examples","children":[{"id":"ci_1b91521702f070747ac76fce16e975f8a8bb9df615d81a05135ecb6081a1b67d","title":"Example 1.","path":"/ideCAD/example-1-1","children":[]},{"id":"ci_ecc1303c78fe00d1d437b95954dc244c27b17122072ee7c142a0b7018e78338f","title":"Example 2.","path":"/ideCAD/example-2","children":[]}]}]},{"id":"ci_c340567122b32433a745c592beeebf748505e69dc79d971ef48b9c9807a1cf50","title":"TS500 Balanced Reinforcement Ratio","path":"/ideCAD/ts500-balanced-reinforcement-ratio","children":[{"id":"ci_3b01462ce81d8bbe2efc9c61b077d4b4d3c9a5ab2b8945612a1df9d69d2652f3","title":"TS 500 - Balanced Reinforcement Ratio Condition","path":"/ideCAD/ts-500-balanced-reinforcement-ratio-condition","children":[]}]}]},{"id":"ci_41ebbe1b5874392004c981808874925777e8bb11067f6bcedde9b32cb0be0bd2","title":"Column-Beam Joint Design","path":"/ideCAD/column-beam-joint-design","children":[{"id":"ci_38ffb439361302f92bf69e171eac00e7582b0493e8cebdbc69888f2962e30cfa","title":"Column-Beam Joint Confinement Conditions (Confined and Unconfined Joints)","path":"/ideCAD/column-beam-joint-confinement-conditions-confined-","children":[]},{"id":"ci_e3729368c86377dcbbf68c5927b9a999cfb43066828e2d69f4ec4dc5b4eb6cb0","title":"Column-Beam Joint Shear Design","path":"/ideCAD/column-beam-joint-shear-design","children":[]}]},{"id":"ci_ca6661ac5de004ec4029b309435e2f95e09b6f6e7e265af6d1929124d473f9fc","title":"Shearwall Design","path":"/ideCAD/shearwall-design","children":[{"id":"ci_2b053d3f6b9104f969fede1a3227d50edc909ed0b4be52612c8a7d67db55ee82","title":"Dimensional Limits for Shearwalls","path":"/ideCAD/dimensional-limits-for-shearwalls","children":[{"id":"ci_8c7384ec2017cbe9da7f46f7f3bfdf72ed7ae31965cde63ea726c78cbf58869d","title":"Dimensional Limit Conditions for Shearwalls","path":"/ideCAD/dimensional-limit-conditions-for-shearwalls","children":[]}]},{"id":"ci_c2a4f77621e06f90ec008b409b22cf2304804d7ff501df64254a7787542ab8ff","title":"Boundary Regions and Critical Wall Section Segment","path":"/ideCAD/boundary-regions-and-critical-wall-section-segment","children":[{"id":"ci_5abbf5bec3b1dab3bd514c244bc0f92ed50a9c877fecaf7233d18058eaff066e","title":"Boundary Regions and Critical Wall Section Segment Conditions","path":"/ideCAD/boundary-regions-and-critical-wall-section-segme-1","children":[]}]},{"id":"ci_7ee75226956a5b9258cbf376bd31e142ee7e6d1ac08422d2fefdb02c060aa909","title":"Web Reinforcement Limits and Detailing for Shearwalls","path":"/ideCAD/web-reinforcement-limits-and-detailing-for-shearwa","children":[{"id":"ci_5f54aea0feaadc4c06a8a9fdd365deaa823c41af274022aeab4782ef6a940d7d","title":"Shearwall web Reinforcement Limits","path":"/ideCAD/shearwall-web-reinforcement-limits","children":[]},{"id":"ci_8d7798addd3f334535f11bd52cc0b5eea470b31b1b10594c68ab23540a687b03","title":"Shearwall Web Reinforcement Detailing","path":"/ideCAD/shearwall-web-reinforcement-detailing","children":[]}]},{"id":"ci_98803a250904aaf640f5bc1fe57ed845f1d4617e0940ea75e759683bc0ef96d7","title":"Boundary Regions Reinforcement Detiling of Shearwalls","path":"/ideCAD/boundary-regions-reinforcement-detiling-of-shearwa","children":[{"id":"ci_ff35c468c4bebc67b6c3569ab5b597a38a32fc16c36781ee2378c0f9bf23002a","title":"Boundary Regions Reinforcement Detiling Conditions","path":"/ideCAD/boundary-regions-reinforcement-detiling-conditions","children":[]}]},{"id":"ci_44218552cbd6058bef99daeddcb7170cfcbf5c5a0f0190c2f2bb57e3061dea51","title":"Shearwall Design For Flexure and Axial Force","path":"/ideCAD/shearwall-design-for-flexure-and-axial-force","children":[{"id":"ci_ee03d585516a99785f9e8b8372072481bf987a7f98d3b4a58b83663a4d4d400a","title":"Design Moment for Shearwalls","path":"/ideCAD/design-moment-for-shearwalls","children":[{"id":"ci_6bed9c53222afa08022f27e4532b3d827f2b234c9b8d41d6d2a9cedb779d0a7e","title":"Design Moment Strength for Shearwalls","path":"/ideCAD/design-moment-strength-for-shearwalls","children":[]},{"id":"ci_27ffe6d09472567ee1684f39d474d1c740aaeb7082579b1a4462ef19e166d24f","title":"Shearwall Design Moment Strength Report","path":"/ideCAD/shearwall-design-moment-strength-report","children":[]},{"id":"ci_ffa5f3b1983887026fa594bd8d3615faafb8098a0683eebe0118f6b3fa9601ff","title":"(7.6.6) Example","path":"/ideCAD/7-6-6-example","children":[]}]}]},{"id":"ci_08e53e279307f4219d1992cd49f5330847f1f81048b007efd475edc4b81ab778","title":"Shear Design of Shearwalls","path":"/ideCAD/shear-design-of-shearwalls","children":[{"id":"ci_ce436fd13054d03c7deeafbb280f31424884a3d1b92dd55c1e85055ef2455d83","title":"Shearwall Design Shear Forces","path":"/ideCAD/shearwall-design-shear-forces","children":[{"id":"ci_40e160fb2b50acaa61b98465ba218078fe185acdc3bcc456c995060899a52531","title":"Design Shear Forces for Walls","path":"/ideCAD/design-shear-forces-for-walls","children":[]},{"id":"ci_85dba43fe5dd22f61d801dce9537ec404a5957fb3dbf30b3102f285cd19345c2","title":"Wall Shear Design Report (7.6.6.3)","path":"/ideCAD/wall-shear-design-report-7-6-6-3","children":[]}]},{"id":"ci_def4a87dbf2c7def3179a4caacb826c61bf25158e88cc21e77e4d9b3efbef8ee","title":"Shear Strength for Shearwalls","path":"/ideCAD/shear-strength-for-shearwalls","children":[{"id":"ci_0e2a8b92a0a80ee9f4cba712b1a1cf258c74af0d093a89a82be48e05ae1be246","title":"Wall Design Shear Strength Calculation","path":"/ideCAD/wall-design-shear-strength-calculation","children":[]},{"id":"ci_83a11bae26a2d80a8ceebd594a0d0deca6e2be50ab1692e187edd0d30c9a9491","title":"Shearwall Design Shear Strength Report","path":"/ideCAD/shearwall-design-shear-strength-report","children":[]},{"id":"ci_729e6ca5a01f7258e3929dcb5e41b47a0a50b16055c9d84975667425706804d8","title":"7.6.7 Example","path":"/ideCAD/7-6-7-example","children":[]}]}]}]},{"id":"ci_0285205e05d7da2b401b05a1faec487daf54c6eaafdd76670ba8a23cb358c18a","title":"Polygonal Cross-Section Shearwall Design","path":"/ideCAD/polygonal-cross-section-shearwall-design","children":[{"id":"ci_f17e9a8bd329d032775616ce49ad18d2b37846dc5f2776d6a1a46ea32915d32c","title":"Dimensional Limits for Polygonal Cross-Section Shearwalls","path":"/ideCAD/dimensional-limits-for-polygonal-cross-section-she","children":[{"id":"ci_87f97e77cbe164742f7422e742af43299b4ce8148b70faaffa78d5224acc3e64","title":"Dimensional Limit Conditions for Polygonal Cross-Section Shearwalls","path":"/ideCAD/dimensional-limit-conditions-for-polygonal-cross-s","children":[]}]},{"id":"ci_89b67f5335f80672e5e6804e8bc4311b5eb005186018613ee2dcf062e26b7577","title":"Boundary Regions and Critical Wall Section Segment.","path":"/ideCAD/boundary-regions-and-critical-wall-section-segme-2","children":[{"id":"ci_a98b62e662281f3545347a80e629e6de8be8b998d3e86f49de9d7c1e5580bc1d","title":"Boundary Regions and Critical Wall Section Segment Conditions.","path":"/ideCAD/boundary-regions-and-critical-wall-section-segme-3","children":[]}]},{"id":"ci_899b574b440fa361ce74ae422a94d71f3c478666930640efc618dff93da3b8c7","title":"Web Reinforcement Limits and Detailing for Polygonal Cross-Section Shearwalls","path":"/ideCAD/web-reinforcement-limits-and-detailing-for-polygon","children":[{"id":"ci_643b8c485ad023928f9ed1b03cbb36bfe285393a18563b317ab7b67b6c0c8162","title":"Polygonal Cross-Section Shearwall Web Reinforcement Limits","path":"/ideCAD/polygonal-cross-section-shearwall-web-reinforcemen","children":[]},{"id":"ci_cf5adff1706b07cc4974991e74bdb56255f85233e48b7bbebc310f83437969b7","title":"Polygonal Cross-Section Shearwall Web Reinforcement Detailing","path":"/ideCAD/polygonal-cross-section-shearwall-web-reinforcem-1","children":[]}]},{"id":"ci_c1bb067a36b7209e424910e8420ab88d4a71f947a9852f4bc8857118c739de09","title":"Boundary Regions Reinforcement Detiling of Polygonal Cross-Section Shearwalls","path":"/ideCAD/boundary-regions-reinforcement-detiling-of-polygon","children":[{"id":"ci_daf5f931fc4c40d2a68bce39cbbcde6064195efadda4334dddf0349de3f717c6","title":"Boundary Regions Reinforcement Detiling Conditions.","path":"/ideCAD/boundary-regions-reinforcement-detiling-conditio-1","children":[]}]},{"id":"ci_c53a7fe937d0b180068220ea4b1ffeccc9d9f938b1bc80a7777a34a8a6f63451","title":"Polygonal Cross-Section Shearwall Design For Flexure and Axial Force","path":"/ideCAD/polygonal-cross-section-shearwall-design-for-flexu","children":[{"id":"ci_8843305016824fbd73285f58a1710cf3e82732868a1a487ad9e55c79011c6e53","title":"Design Moment for Polygonal Cross-Section Shearwalls","path":"/ideCAD/design-moment-for-polygonal-cross-section-shearwal","children":[{"id":"ci_bc33582a7a71ea2f9ac3683858123b0d51a3a01be7533a7e37e7d97bafe3d824","title":"Design Moment Strength for Polygonal Cross-Section Shearwalls","path":"/ideCAD/design-moment-strength-for-polygonal-cross-section","children":[]},{"id":"ci_bad894750c6a17ef2922d3b7c59bc352c4d725a356d9e42874b54e4967bcbc60","title":"Polygonal Cross-Section Shearwall Design Moment Strength Report","path":"/ideCAD/polygonal-cross-section-shearwall-design-moment-st","children":[]},{"id":"ci_34eeb2018bda0454f78a4a3423717eb4ee24a09d97baac0b30d7ef4b5a1ed846","title":"Polygonal Cross-Section Shearwall (7.6.6) Example","path":"/ideCAD/polygonal-cross-section-shearwall-7-6-6-example","children":[]}]}]},{"id":"ci_f9ce3a6d40b80fe879a8f46f5a6eb2fbc2a6e166590b93efc5aee3ac4dca860e","title":"Shear Design of Polygonal Cross-Section Shearwalls","path":"/ideCAD/shear-design-of-polygonal-cross-section-shearwalls","children":[{"id":"ci_1ffbda07c3a8db589c11f02077963117e087f035a511105d1f78cf8c7654492e","title":"Polygonal Cross-Section Shearwall Design Shear Forces","path":"/ideCAD/polygonal-cross-section-shearwall-design-shear-for","children":[{"id":"ci_d82a942283b2d17885f833b1bd0e0ac6049d507a1ae5ebec17be9e603cd267d1","title":"Design Shear Forces for Polygonal Cross-Section Walls","path":"/ideCAD/design-shear-forces-for-polygonal-cross-section-wa","children":[]},{"id":"ci_4230d876a190a4da563f99173da2f392ea173ee2dfe66a0b33ee7194ff042e0f","title":"Polygonal Cross-Section Wall Shear Design Report (7.6.6.3)","path":"/ideCAD/polygonal-cross-section-wall-shear-design-report-7","children":[]}]},{"id":"ci_22f11123a161e117d043cc0a06a127deb729129ad761796091222f4a5a5e1afc","title":"Shear Strength for Polygonal Cross-Section Shearwalls","path":"/ideCAD/shear-strength-for-polygonal-cross-section-shearwa","children":[{"id":"ci_0d98e4b2a4f736640d85d0a11e300ea3bfd3f63d1a763b74143a92dc4ad7e4e1","title":"Polygonal Cross-Section Wall Design Shear Strength Calculation","path":"/ideCAD/polygonal-cross-section-wall-design-shear-strength","children":[]},{"id":"ci_d433778c348ff575c3667b2ce1ff543951add1a9557247215e28a957577b3357","title":"Polygonal Cross-Section Shearwall Design Shear Strength Report","path":"/ideCAD/polygonal-cross-section-shearwall-design-shear-str","children":[]},{"id":"ci_fdf51ff6608e6de5ec46f48d4e7b095172e52bca5bef5145419c73f7720bf18f","title":"7.6.7 Example Polygonal Cross-Section Walls","path":"/ideCAD/7-6-7-example-polygonal-cross-section-walls","children":[]}]}]}]},{"id":"ci_024938a99e27ebd5cb5477e13c31c9694ff7d27a8bd9f2a0bc202dd5f7a5678e","title":"Slab Design","path":"/ideCAD/slab-design","children":[{"id":"ci_d2681d05c3b9de47bdec53d43dba42e326ad567724a1758e9f7b898251e5485e","title":"Slab Stress Controls","path":"/ideCAD/slab-stress-controls","children":[{"id":"ci_efc27fef3442fc8d9e673eb2704d7860407d26192fd6f58b531c7c7a4c76547d","title":"Slabs with In-Plane compressive and Shear Stresses (7.11.3)","path":"/ideCAD/slabs-with-in-plane-compressive-and-shear-stresses","children":[]},{"id":"ci_dbfd8356124ac23d5ffb72cb53cccaa28479721919778ad631763b133f3c243f","title":"Slab Stress Condition Report","path":"/ideCAD/slab-stress-condition-report","children":[]},{"id":"ci_e8c65ca3d06df287bc18f157e33b0928881de37f9d105d462143d0b7d6fec0e6","title":"(7.11.3) Example","path":"/ideCAD/7-11-3-example","children":[]}]},{"id":"ci_67f7f4d24acd2aa660af502ab6bca8faf4c917335804435f1f76079165f05a80","title":"Collector elements to Transfer Force Between Diaphram (Slab) and Shearwall","path":"/ideCAD/collector-elements-to-transfer-force-between-diaph","children":[{"id":"ci_4e04816d578109840930fbaac1b149cabc576cafdd9b0e88a7def987164b4b45","title":"Parallel and Perpendicular Reinforcement as Collector Elements (7.11.5)","path":"/ideCAD/parallel-and-perpendicular-reinforcement-as-collec","children":[]},{"id":"ci_6734271e6b96b0ca2574f257a2d6b8f7e66d7cc616a9238e9ab7f514afb9a728","title":"Transfer Force Between Diaphram (Slab) and Shearwall Report","path":"/ideCAD/transfer-force-between-diaphram-slab-and-shearwall","children":[]},{"id":"ci_22c8f6c22687b7ed662071838b0bee3bbad3b783cfb0e32b9ac5a430fd6e565a","title":"(7.11.5) Example","path":"/ideCAD/7-11-5-example","children":[]}]},{"id":"ci_146fe3021b547b6bced080754b6067ab209bd2005ff8b769999d8a5c2978af97","title":"Punching Shear Check","path":"/ideCAD/punching-shear-check","children":[{"id":"ci_c8e6f23c3eb51e8f62ff3b3b8ca8afcf410e1b7cfc49f27f4ad37782ea1ce35a","title":"Punching Shear Stress at Critical Section (7.11.8)","path":"/ideCAD/punching-shear-stress-at-critical-section-7-11-8","children":[]},{"id":"ci_2ff7b611a1800960fcc039f2621583a9c14a429d45b7bfdacccb6550d742af35","title":"(8.3.1) TS500 Puching Shear Design Conditions","path":"/ideCAD/8-3-1-ts500-puching-shear-design-conditions","children":[]},{"id":"ci_529d598b868f2b30362b4b8f15923e3693e4128acdd6d42d3200502429092c0f","title":"Punching Shear Stress Check Report","path":"/ideCAD/punching-shear-stress-check-report","children":[]},{"id":"ci_e6940c79fc15a934f1735ebdea4e4b5f5f85774d0de31fa1a4d976a451986783","title":"Punching Shear Check Example 1","path":"/ideCAD/punching-shear-check-example-1","children":[]},{"id":"ci_80f7ba8cd6f9faac2d3bfd29ce7d04ee71ecfd4a5a9b786c4b377da48d5b300b","title":"Punching Shear Check Example 2","path":"/ideCAD/punching-shear-check-example-2","children":[]}]}]},{"id":"ci_7fdb6ba57fe8709253163ca801ea14f4a695f9e641d7454e981efede9d76a15a","title":"Foundation Beam Design","path":"/ideCAD/foundation-beam-design","children":[]},{"id":"ci_793fddb453016822271a8761687a7664bd84a254d169b23e052af7973b32717b","title":"Deflection Control","path":"/ideCAD/deflection-control","children":[{"id":"ci_815d772c09e72ca4bbd0678321e473baa5e8b9fc0cbbd52588f52fe481b8e8df","title":"Instantaneous Deflections (TS500)","path":"/ideCAD/instantaneous-deflections-ts500","children":[]},{"id":"ci_dd9af1008a58d7f8d391ac289825af99b9cf212bef7d4fc98e498a32f1cbac62","title":"Time-Dependent Deflections (TS500)","path":"/ideCAD/time-dependent-deflections-ts500","children":[]},{"id":"ci_81b63aac8e5996c44ba26ed710a3ec0d3feb625c5b29777fc5ec40fb01761665","title":"Deflection Limits (TS500)","path":"/ideCAD/deflection-limits-ts500","children":[]},{"id":"ci_104c3aa0aa0edf31dd49a3fb93c91e605c8ee14228ed2ba38ec31bc486e2a92f","title":"Deflection Control Examples","path":"/ideCAD/deflection-control-examples","children":[{"id":"ci_6b8eaebdc67af2af84bc1021ba188386ccf1352f055e0368bb03f04986f7a08e","title":"Instantaneous and Time Dependent Deflection Example 1","path":"/ideCAD/instantaneous-and-time-dependent-deflection-exampl","children":[]},{"id":"ci_67e77a3cc699fa32596fe01ce5451495e7bfd0a077f9fa51cdb8642e9657bd13","title":"Instantaneous and Time Dependent Deflection Example 2","path":"/ideCAD/instantaneous-and-time-dependent-deflection-exam-1","children":[]}]}]}]},{"id":"ci_823cb587cbd17d6fafd0e5e7489dc2761367ee6de15a9eddc2abfd77fdd36baf","title":"Building Base and Building Height","path":"/ideCAD/building-base-and-building-height","children":[{"id":"ci_182eab8ecd4cbc9da3c5f79c68def128bd07a3acec4d46520a2aaa0d24d54413","title":"Period Requirement for Structures Including Rigid-Basement Floors (3.3.1)","path":"/ideCAD/period-requirement-for-structures-including-rigid-","children":[]}]},{"id":"ci_6500649e64f013d87ceb2474e92accb711364728648766b8b513e9b6a603825e","title":"Building Height Category","path":"/ideCAD/building-height-category","children":[{"id":"ci_81f8f09e0ff9f7c1d0d8aea0be651eb8e9a7c6e9e39dab8671e1e68515f0758d","title":"Building Height Category (3.3.2)","path":"/ideCAD/building-height-category-3-3-2","children":[]}]},{"id":"ci_98c4c4d2827b3c85533289de09b5725e960a5026f6e11183579ecc902da07db5","title":"Building Importance Factor","path":"/ideCAD/building-importance-factor","children":[{"id":"ci_05107d7585e664ecc9e2b191cf3a7b73865ce2693e8b5147c3e167937840f1a3","title":"Building Importance Category Selection (3.1.2)","path":"/ideCAD/building-importance-category-selection-3-1-2","children":[]}]},{"id":"ci_c4e7c001f02eca4e7afcddee2715aad095123d7319a5fcb5914e94e3dcf8b871","title":"Building Performance Levels","path":"/ideCAD/building-performance-levels","children":[{"id":"ci_4eb97d57843ac0466d0a99c7b6e6da317138eba155fee16e52b26954de8c9293","title":"Building Performance Levels (3.4)","path":"/ideCAD/building-performance-levels-3-4","children":[]}]},{"id":"ci_553131ae84027860bc2908590e7804744ef9c1429d8f51ffe9b37922923a3577","title":"Building Performance Requirements","path":"/ideCAD/building-performance-requirements","children":[{"id":"ci_f66983884a6aab0c1f7537a0a76326044f6a4e0e278b2afc73a9516b68b4b0ba","title":"Building Performance Requirements (3.5.1)","path":"/ideCAD/building-performance-requirements-3-5-1","children":[]}]},{"id":"ci_5d187b702a9b81db9b625515138673e251fced2e7786e0f6ad6393265f112214","title":"Requirement / Design Assumptions","path":"/ideCAD/requirement-design-assumptions","children":[{"id":"ci_248d6cdd34ecba2ca96f52931f392c2487559171b787f895d8a4c756a998669d","title":"Requirement / Design Assumptions (3.5.2)","path":"/ideCAD/requirement-design-assumptions-3-5-2","children":[]}]},{"id":"ci_1ffbcded1d568a830641c8774949e716c642047b5f622bee526bcecdbb864130","title":"Seismic Design Category.","path":"/ideCAD/seismic-design-category","children":[{"id":"ci_dd158f6c562e21e45b7a2f2242d5e8137cadfa9ccc0e0d8b34a5e69c7f4e7b8b","title":"Determination of Seismic Design Category (3.2)","path":"/ideCAD/determination-of-seismic-design-category-3-2","children":[]}]},{"id":"ci_e142a803c27c7aa67d4bf97161b9d20846bfd43ea94fab38f4ffd6ff3541f255","title":"Structural Irregularities from Earthquake Effect","path":"/ideCAD/structural-irregularities-from-earthquake-effect","children":[{"id":"ci_652c9b308fb1a3e473e98cc73de5ab6e0d746f6ffe8a30c15f37285d09c46e4f","title":"A1 - Torsional Irregularity","path":"/ideCAD/a1-torsional-irregularity","children":[{"id":"ci_e8bae68dbe2953109d0a5e2cc7fd9007ab96280cab331ccbabfe021bf001f350","title":"Earthquake Code Statement (3.6.2.1)","path":"/ideCAD/earthquake-code-statement-3-6-2-1","children":[]}]},{"id":"ci_da70c5ac8dd39d6758c54296e97798facebcc21bd81a35fb889ea2d8f6cf5cc5","title":"A2 - Floor Discontinuities","path":"/ideCAD/a2-floor-discontinuities","children":[{"id":"ci_124512cd9c9dbfc8ab9ad1e718e8cd6e1970d0da7c0e44d5a00e41381d78256a","title":"Earthquake Code Statement (3.6.2.2)","path":"/ideCAD/earthquake-code-statement-3-6-2-2","children":[]}]},{"id":"ci_485efae3d66359376abefca3c9a6d8d607407d9a2137f5991ad9eb676d54f261","title":"A3 - Reentrant Corner","path":"/ideCAD/a3-reentrant-corner","children":[{"id":"ci_457f2202d6a6fe9b70bfc4ffa630eb7535dee3b2e1b6cb651ebb3ebe5b9c3e37","title":"Earthquake Regulation Statement (3.6.2.2.)","path":"/ideCAD/earthquake-regulation-statement-3-6-2-2","children":[]}]},{"id":"ci_ac960423125a531400b47a080450e25466ead28480e34c72791f858a5da4bfb6","title":"B1 - Discontinuity in Lateral Strength Weak Story Irregularity (Weak Story)","path":"/ideCAD/b1-discontinuity-in-lateral-strength-weak-story-ir","children":[{"id":"ci_fd16bf40af3fbee533ddc696306e141bd7967b5d82815954aa7578188d4e23f7","title":"Earthquake Code Statement (3.6.2.3)","path":"/ideCAD/earthquake-code-statement-3-6-2-3","children":[]}]},{"id":"ci_27afe2c049ac95f5cb2ffd25f6859031ea0dfd6359b9cb6a1c04a66072dbc7e2","title":"B2 - Stiffness–Soft Story Irregularity (Soft Story)","path":"/ideCAD/b2-stiffnesssoft-story-irregularity-soft-story","children":[{"id":"ci_61dbaa885062070fcab8c74ec0c14b5e9a344d171be8ae1b0778e2b40639c846","title":"Earthquake Regulation Statement (3.6.2.1.)","path":"/ideCAD/earthquake-regulation-statement-3-6-2-1","children":[]}]},{"id":"ci_cd895167d0fc588655caffc8e825bb57132ed30355e0d472043a1d89e199a58a","title":"B3 - Discontinuity of Vertical Elements of the Structural System (Vertical Geometric Irregularity)","path":"/ideCAD/b3-discontinuity-of-vertical-elements-of-the-struc","children":[{"id":"ci_36a9d90ebe71e63dccc1d7bd0a40f550a6f417f8e82c77f0937a0c7aa141d316","title":"Earthquake Code Statement (3.6.2.4)","path":"/ideCAD/earthquake-code-statement-3-6-2-4","children":[]}]}]}]},{"id":"ci_7441fe35b094afabaf2d74e2710cd10190fe79ead2f80b26e532f4f006b639b3","title":"TSC 2018 Wizard","path":"/ideCAD/tsc-2018-wizard","children":[{"id":"ci_fcec7753ca0244ca0f173e245d60f61478159c0bb5bc5da4679e07611fcfef84","title":"Earthquake Ground Motion Level","path":"/ideCAD/earthquake-ground-motion-level","children":[]},{"id":"ci_f604b93cb9100fc9d43e6faf9abd8493ef10ba2067fe5db2fe643f9c4ad31bbd","title":"Site Class","path":"/ideCAD/site-class","children":[]},{"id":"ci_3f794eaace5fcefcbd6f9be96f5ce9633320943157c12a1732ea5e1354e9634c","title":"Design Spectra","path":"/ideCAD/design-spectra","children":[]},{"id":"ci_891df34c9f1379c8d6d2e33cd51e100c7daddae8bf8d1f26bcc18543ff267bf9","title":"Building Risk Category","path":"/ideCAD/building-risk-category","children":[]},{"id":"ci_eed44ec450558ff71f2a80b2416d6b73429ee83ff4af9962b07ab1b7cca220c9","title":"Seismic Design Category","path":"/ideCAD/seismic-design-category-1","children":[]},{"id":"ci_5744bb0b4bca48dcf282dc35dc948e96cc1afa1c08507bc13f98f04f5766f83a","title":"Stories","path":"/ideCAD/stories","children":[]},{"id":"ci_7b744a4ad631a2787848f2b72120741145e7e4aa6c3e51e241a179f3450cad91","title":"Building Height Class","path":"/ideCAD/building-height-class","children":[]},{"id":"ci_2a558b664963f1aa5172bbf1300c0bb4dac675217d0f1c47eb3225a5413b2377","title":"Performance Level","path":"/ideCAD/performance-level","children":[]},{"id":"ci_aae4472c17f21b1e420edc475e7b7eaee37339e7dca1b8b4980925e8066fb36b","title":"Structural system","path":"/ideCAD/structural-system","children":[]},{"id":"ci_ca838cb218affe5f620c8be0c2b874da51467756423154fffff76956b0fcc86d","title":"Slab Type","path":"/ideCAD/slab-type","children":[]},{"id":"ci_ae579af7c67d550c9c12768af57674786c41359b4f46e5a5243efe487944b2b2","title":"Diaphragm","path":"/ideCAD/diaphragm","children":[]},{"id":"ci_dc3ac6fc23ec8bab865723f4c071841e0537b3a91a9ea7da71edcd281b816fa7","title":"Ductility","path":"/ideCAD/ductility","children":[]},{"id":"ci_87bb5163e6d3976dba87fe48cfd57499d1c125701dcc2de0ee7371457b67dcce","title":"R Coefficient - X","path":"/ideCAD/r-coefficient-x","children":[]},{"id":"ci_1b101c9c71876018bb27c4e5d289071fa26185046cfb5998f596d98704d9931b","title":"R Coefficient - Y","path":"/ideCAD/r-coefficient-y","children":[]}]},{"id":"ci_01dfb6af9d6f64604c3033163c7ff65b85a11ffaddf6e6f73a44784b97151ec4","title":"Structural Steel Design Requirements of TSC 2018","path":"/ideCAD/structural-steel-design-requirements-of-tsc-2018","children":[{"id":"ci_ee6fc8e8cb691f9812e5fe2395396dc68669bff938659b6dce633eebb15ec910","title":"Moment Resisting Frame Systems","path":"/ideCAD/moment-resisting-frame-systems","children":[{"id":"ci_d1ceef101072e6c9dbfd8efe64d502aea5e1c18e9f9286500c191089eb731f5e","title":"High Ductile Moment Resisting Frames","path":"/ideCAD/high-ductile-moment-resisting-frames","children":[{"id":"ci_72e5466ec0a298e90eeaa2a4e9a8b630583c8fb43f05a2e32e8dda3d760c34d3","title":"9.3.1.1","path":"/ideCAD/9-3-1-1","children":[{"id":"ci_7aaea115bcacb266cf6aeed759e1096b7ac69f330d86e2ec836bea594e45647f","title":"9.3.1.1 Width-to-Thickness Ratios Report","path":"/ideCAD/9-3-1-1-dimensional-check-of-cross-sections-report","children":[]}]},{"id":"ci_ddc63594b2eb3f9efbd7db9d48e1b25de6667e170764bb8c637c63d56699dbb8","title":"9.3.1.2","path":"/ideCAD/9-3-1-2","children":[{"id":"ci_0f852cbb8739b83b9a42e398882b4feb8c1acacfdfb5eb31d13a058bc2e5c804","title":"9.3.1.2 Lateral Stability Bracing Report","path":"/ideCAD/9-3-1-2-lateral-stability-bracing-report","children":[]}]},{"id":"ci_5e5039340e3c39d93c110cc9e12b96a4721114293849e7b828a81155c227656f","title":"9.3.1.3","path":"/ideCAD/9-3-1-3","children":[{"id":"ci_61fa4aac990596a78197dcb7e04a0d6486afdd1bf1c381fa5978d25818e44f54","title":"9.3.1.3 Column Axial Capacity Control Report","path":"/ideCAD/9-3-1-3-column-axial-capacity-control-report","children":[]}]},{"id":"ci_5201b768b184b280c9b6868b7f4013a924d402de4b2a1a63378b3e0f2b2b91cb","title":"9.3.1.4","path":"/ideCAD/9-3-1-4","children":[]},{"id":"ci_08d01f9d2cacaaa5f72daf3149d83a8567a4f99793fd9424632239c46646e335","title":"Strong Column Weak Beam Conditions","path":"/ideCAD/strong-column-weak-beam-conditions","children":[{"id":"ci_c8ddca227fea314f9716fade22d67577c89e17134abe3c0a6efcfe496ccdc98c","title":"9.3.2","path":"/ideCAD/9-3-2","children":[]}]},{"id":"ci_501a8e62fa8e1e26e99556a3f7af5647ad0bbc9812158f864dc8fa54fd5db94d","title":"Beam-to-Column Connection Requirements","path":"/ideCAD/beam-to-column-connection-requirements","children":[{"id":"ci_f123d6a46b5a1ca8359c6b36c0c932d9941a3346428ad6b15fe5d01edf79b53a","title":"9.3.4","path":"/ideCAD/9-3-4","children":[]}]}]},{"id":"ci_5dac08f9f5dd16f6ea0fb2dbe2bd2bca55c7beb5c8e27df97c7f3c8e7abdae6d","title":"Moderately Ductile Level Moment Resisting Frames","path":"/ideCAD/moderately-ductile-level-moment-resisting-frames","children":[{"id":"ci_d7132a9c066f83bb79d416078bd963a51f59965ef31fa82f3f8d467e2b453f26","title":"9.4.1.1","path":"/ideCAD/9-4-1-1","children":[{"id":"ci_2c0ecaa87407afe581cebe3a45eaee610ea595fcdf507f292941f39b2ae7e6a0","title":"9.4.1.1 Dimensional Check of Cross-Sections Report","path":"/ideCAD/9-4-1-1-dimensional-check-of-cross-sections-report","children":[]}]},{"id":"ci_4e372e955276657474696d3352a2a73b33b26889feb42eefe907bce3b43453bb","title":"9.4.1.2","path":"/ideCAD/9-4-1-2","children":[{"id":"ci_1131b967e07102f1f90184f8c129a578542679231532b9e36861ed042f2ca567","title":"9.4.1.2 Lateral Stability Bracing Report","path":"/ideCAD/9-4-1-2-lateral-stability-bracing-report","children":[]}]},{"id":"ci_7008bf7f62e393476ca0fad5da0fec79437ed5dbc68f49457d0908785b85c0c8","title":"9.4.1.3","path":"/ideCAD/9-4-1-3","children":[{"id":"ci_3c9aad44c2aa28c880c5feff5a9be4b153956ff00dcd69e804f7ca8d8a1fdf76","title":"9.4.1.3 Column Axial Capacity Control Report","path":"/ideCAD/9-4-1-3-column-axial-capacity-control-report","children":[]}]},{"id":"ci_92e9c55e76bedeefd4d3b6d65aa57f73918acdf7bf9ca58b4eb3969cdd8a4347","title":"9.4.1.4","path":"/ideCAD/9-4-1-4","children":[]},{"id":"ci_f453735fe59c204a91f15d414ece94258f43db6b400a52cf16976d74e6e4771c","title":"9.4.1.5","path":"/ideCAD/9-4-1-5","children":[]},{"id":"ci_3ab03cd2c6bfb5f8c969b5aedfb12a8ef26c48078079f2ea47937296cf280f6b","title":"Beam-to-Column Connection Requirements.","path":"/ideCAD/beam-to-column-connection-requirements-1","children":[{"id":"ci_466e1ac523ab4941c55b2b00a7235127e3f720b3f4af0b8c814b62a6c47dc030","title":"9.4.2","path":"/ideCAD/9-4-2","children":[]}]}]}]},{"id":"ci_2123abbce1baec1fe03b781c85a10158d122bc2dcdbc6581729cf7f044febc88","title":"Concentrically Braced Frame (CBF)","path":"/ideCAD/concentrically-braced-frame-cbf","children":[{"id":"ci_3a706b9d288277cf3f659ec9f4a9d9bfd9e8e84f52a03e6fffbf807ac90f2a56","title":"Highly Ductile Concentrically Braced Frame","path":"/ideCAD/highly-ductile-concentrically-braced-frame","children":[{"id":"ci_7e19deb61caea43f906cbe217669ae860129a20eee32db2bbc16817170c3e3ab","title":"9.6.1.1","path":"/ideCAD/9-6-1-1","children":[{"id":"ci_51cb016560a210678b2ccb8a7a8caca4c8c20382e28d88d8af7555bf8b2ad36a","title":"9.6.1.1 Dimensional Check of Cross-Sections Report","path":"/ideCAD/9-6-1-1-dimensional-check-of-cross-sections-report","children":[]}]},{"id":"ci_392cff700dc46868ce801a7df8ad6dd477f0bf086be835cb6dc582a4354b91f4","title":"9.6.1.2","path":"/ideCAD/9-6-1-2","children":[]},{"id":"ci_966df8ba4f9c56135c14f995a09ce613aa247477980176a50231f9e43ab10457","title":"9.6.3.1","path":"/ideCAD/9-6-3-1","children":[{"id":"ci_2326da73a0ba700ff3fcd90875abdc94aad1645c1330f0ab7b35b879ca19e96d","title":"9.6.3.1 Slenderness Ratio Report","path":"/ideCAD/9-6-3-1-slenderness-ratio-report","children":[]}]},{"id":"ci_bd307034285ac158e5d970a473391d9d468ffc07bb545aabfc6b72ef886102ae","title":"9.6.3.3","path":"/ideCAD/9-6-3-3","children":[]},{"id":"ci_c5a48da9138a96b56ad25da9e3bd37030501a7d75a3e3a20b141dfaeb8f68b45","title":"9.6.3.4","path":"/ideCAD/9-6-3-4","children":[{"id":"ci_87e4aefa9e7025fc45b63f399c3a078cfc49c0a6e7c838ca37d43a75007db1b3","title":"9.6.3.4 Ductility Control Report","path":"/ideCAD/9-6-3-4-ductility-control-report","children":[]}]}]},{"id":"ci_3e8aec4a715a2bb0997d1973526d738899f23d810d8001e92004f1c53e661f35","title":"Moderately Ductile Concentrically Braced Frame","path":"/ideCAD/moderately-ductile-concentrically-braced-frame","children":[{"id":"ci_dafcea8296676876429dad859410c77619efb4d95ece6a2add8be566fdd53c80","title":"9.7.1","path":"/ideCAD/9-7-1","children":[{"id":"ci_05928f46287eb2ec8e101946e53560a783a4b0e56839a3d5c0b5fe8438f37781","title":"9.7.1.1 Dimensional Check of Cross-Sections Report","path":"/ideCAD/9-7-3-1-dimensional-check-of-cross-sections-report","children":[]}]},{"id":"ci_77bbe12796d970a997f81fa226ee62ca08011f4693b455b4547a0241228bbe12","title":"9.7.2","path":"/ideCAD/9-7-2","children":[]},{"id":"ci_4bb5705fde57797000a4833c803217c6320acc32b763b8778cffcc3a3a455c33","title":"9.7.3","path":"/ideCAD/9-7-3","children":[{"id":"ci_4c96511b341407c6da10de1cdd628b573bb252446d17278b4319a8c7e5a6eeca","title":"9.7.3.1 Slenderness Ratio Report","path":"/ideCAD/9-7-3-slenderness-ratio-report","children":[]}]}]}]}]},{"id":"ci_03e30570ea5d24f34db145035b0072edde5cb4d7a38b828e539823b66924a9c5","title":"ASCE 7-16 Seismic Wizard","path":"/ideCAD/asce-7-16-seismic-wizard","children":[{"id":"ci_2dd4a7b0b5cb76621d1fbe6f5d634d725cc634eb496a062d388fc825b34f6753","title":"Site Classes ASCE 7-16","path":"/ideCAD/asce-site-classes","children":[]},{"id":"ci_5231b142a6fe4311c41524bd91a1df4567d041f963cbf249d2c0472e5bf9f10e","title":"Risk Category and Seismic Importance Factor ASCE 7-16","path":"/ideCAD/asce-selecting-risk-category-of-building-and-impor","children":[]},{"id":"ci_a44278354a10c38e45697758194c6be2c7204d3629e79f3aa6cc0fb63c18b1f2","title":"Horizontal and Vertical Elastic Design Response Spectrum ASCE 7-16","path":"/ideCAD/asce-horizontal-and-vertical-elastic-design-respon","children":[]},{"id":"ci_bcb46112fc8411fb8f9dbdc78a225a1e709f337b5a1f1a40ffd9579af9976abc","title":"Seismic Design Category (SDC) ASCE 7-16","path":"/ideCAD/asce-seismic-design-category-sdc","children":[]},{"id":"ci_2a286395ebe9a6e609cd10b98150fb89e9404c404cce30bf6b26bfd0684c02ff","title":"Stories and Structural Height ASCE 7-16","path":"/ideCAD/asce-story-elevations","children":[]},{"id":"ci_069d0bae5d73307aa2d1bb36eb701a26066dff7a0faff0fa384f8ab92be5124d","title":"Structural System Type ASCE 7-16","path":"/ideCAD/asce-selecting-structural-system","children":[]},{"id":"ci_0304cd27bbd626a5b980b8c6aafda3ce35171a3bbb02f1e68653e8d936ab76f7","title":"Selecting Diaphragm Type ASCE 7-16","path":"/ideCAD/asce-selecting-diaphragm-type","children":[]},{"id":"ci_699cdc38838de96f5035e5ac372a1835cfde3f213de47aee78b759566a23f91b","title":"Seismic Force Resisting System Selection ASCE 7-16","path":"/ideCAD/asce-selecting-ductility-level","children":[]},{"id":"ci_bb5e0276ccf08ae6c4bbfe6ff80eeb2d0a883d23913c27566b3b02b9e83d5282","title":"Design Coefficients and Factors ASCE 7-16","path":"/ideCAD/asce-design-coefficients-and-factors-for-x-directi","children":[]}]}]},{"id":"ci_ae3b8337de048d21c9eaa7e397b554abe2d27d2b28d68b39e0284c95a362a462","title":"Structural System Modeling","path":"/ideCAD/structural-system-modeling","children":[{"id":"ci_4ada098fd2987a3eb89109454f6ea161e96a3103be1e5ef9941104bd517cc19e","title":"Units","path":"/ideCAD/units","children":[]},{"id":"ci_9b34c552ba8da3702a89ae4f6b92084b8aafda5abf784d0576c9aebbcd8b16e0","title":"Structural Materials","path":"/ideCAD/structural-materials","children":[{"id":"ci_5fc0f31ef9d4b7ee65fcf3ecf823c62d2a9d27efcb4541201065cfc5a02a93ed","title":"Select Entities Using Material","path":"/ideCAD/select-entities-using-material","children":[]}]},{"id":"ci_b55b5d71e52f1208a25e8ef497346668ea27f9c0e4a6c47f49371cd227215bc2","title":"Fiber Reinforced Polymer Library","path":"/ideCAD/fiber-reinforced-polymer-library","children":[]},{"id":"ci_fc5a5abbdfd87539a52148556d6d0803c91d20d6d3851bc045042da87738752e","title":"Sections","path":"/ideCAD/sections","children":[{"id":"ci_1362cc500e6944702aaf77315772092c5218252d603acc2c484b27e09506605f","title":"Create Custom Section","path":"/ideCAD/create-custom-section","children":[]},{"id":"ci_a9f5ab5d9276809e455463a843d60c384771b304da2d19a7cbd4f883e8e75ee2","title":"Creating a Cross Section","path":"/ideCAD/creating-a-cross-section","children":[]},{"id":"ci_11af0094f0e499905b7b9188767a32ca7177187e16cda535730192f49f9f1b60","title":"Load Steel Section From Library","path":"/ideCAD/load-steel-section-from-library","children":[]},{"id":"ci_e6bb842a038e91ad7e12dd229675dbbaf4f945cdb8a4d46440904405a6b55814","title":"Remove Unused Sections From the Structure Tree","path":"/ideCAD/remove-unused-sections-from-the-structure-tree","children":[]},{"id":"ci_7b7ac59e79798e4f02d1a69982b57153f237c0b13e59a5bed18c04e87d1de900","title":"Select Entities Using Section","path":"/ideCAD/select-entities-using-section","children":[]}]},{"id":"ci_a8770df794efb6fd9493e71b44ef2c15dca027f45b9dfa98086c4a4c52ff9cd1","title":"Soil Layers","path":"/ideCAD/soil-layers","children":[]},{"id":"ci_ce16d9e857aa2a02e363bf0ece7c72214965dcf4a4cfae0a0a30ab9ac928728f","title":"Structure Mass","path":"/ideCAD/structure-mass","children":[{"id":"ci_d5dd9ca8cb129a7f37907138028aa6289d33318a9595d37703a053e33dc7829a","title":"Structure Mass for Rigid Diaphragm Modelling","path":"/ideCAD/structure-mass-for-rigid-diaphragm-modelling","children":[]},{"id":"ci_8abcb7a41d03a1eca36b648edf0a8832d7158dfdcfb039eecba2034478709cd3","title":"Structure Mass for Flexible Diaphragm Modelling","path":"/ideCAD/structure-mass-for-flexible-diaphragm-modelling","children":[]}]},{"id":"ci_34a941322c8f8d7029422af2eed038ebbc2577f0411dee4fdf53490bec3e5ae3","title":"Load Information","path":"/ideCAD/load-information","children":[{"id":"ci_da231e106bdf7f6bbf50b501aeb83dce602710f0f440756eb242bff91a151df6","title":"Load Library","path":"/ideCAD/load-library","children":[]},{"id":"ci_35842d38f62d7a30821b7f396a9954ad7f3c02c3bbd32ac739d549a48379c8e7","title":"Uniform Load","path":"/ideCAD/uniform-load","children":[]},{"id":"ci_284371cb80722f24425044fe1aa4f7e4aff0662b38348d3f6d5f9b63a4213468","title":"Point Load","path":"/ideCAD/point-load","children":[]},{"id":"ci_3145c798796460d911ba9adf42cf6a0063142404127e676fa858774a039d3046","title":"Trapezoidal Load","path":"/ideCAD/trapezoidal-load","children":[]},{"id":"ci_c4d12824bb30d0867d7b9bd3b48f7c559d895aad25e35530379bfcf4ec9f0108","title":"Panel Vertical Load","path":"/ideCAD/panel-vertical-load","children":[]},{"id":"ci_5e5c31cb7dadc6bfd13558949fb2086e64ec1525f4d58e8ba6779c29d2a901f0","title":"Panel Lateral Load","path":"/ideCAD/panel-lateral-load","children":[]},{"id":"ci_cfed7501b43eece1637f944522b7005202544ce079baf1aa360079d7f801f4e7","title":"Uniform Area Load","path":"/ideCAD/uniform-area-load","children":[]},{"id":"ci_ab8dc7fa8a70e77a654baf9e13c6a63fd4b05ed52479cad85d1c2995cf403ac5","title":"Panel Soil Load","path":"/ideCAD/panel-soil-load","children":[]},{"id":"ci_70082d6c7c26a80038a994e72a3bf650ff13c12fb020b06aefec3958d0228511","title":"Panel Hydrostatic Load","path":"/ideCAD/panel-hydrostatic-load","children":[]},{"id":"ci_f7e57323acff63d26e1f9cba47e07aefd809962611281c761b5079609b98d19d","title":"Edit Entity Loads","path":"/ideCAD/edit-entity-loads","children":[]},{"id":"ci_52d95dcda5a96ec842c95ed56e38e4c2f26795534fcc47561a46f1162423c865","title":"Point-Linear Load Settings","path":"/ideCAD/point-linear-load-settings","children":[]}]},{"id":"ci_03a80ff82c9b04075fea78824fea284b5c8d93d3b774af009edaee223d11a878","title":"Load Cases","path":"/ideCAD/load-cases","children":[{"id":"ci_3589e79ffb7da90549228c4fa1462e24bb0e4f5621c71975ebf0556643a645fd","title":"Static Linear Load Case","path":"/ideCAD/static-linear-load-case","children":[]},{"id":"ci_9c44701db8b31b87e1c7b1b25bf207cbcb9a130a935d5d0d9311364ef5a138c9","title":"Nonlinear Analysis Case","path":"/ideCAD/nonlinear-analysis-case","children":[]},{"id":"ci_a74115ecad333cc7c3602590b14c366c120c4dab1facbb4fa2654541e3234005","title":"Modal Analysis Case","path":"/ideCAD/modal-analysis-case","children":[]},{"id":"ci_29fb44b6314ee702bda135e5d35dfd967acb4f8bc13cb4553c98ed45a9dac35e","title":"Response Spectrum Function","path":"/ideCAD/response-spectrum-function","children":[]},{"id":"ci_748151687f36089bb948d0ccd8e31cd3a2895c10bc3ae6277524feffb54ca09e","title":"Response Spectrum Case","path":"/ideCAD/response-spectrum-case","children":[]},{"id":"ci_b55f46f90b02cc9c8c2770e736e1e396b53eb3ea7a74b148949eae797019be27","title":"Euler Buckling Case","path":"/ideCAD/euler-buckling-case","children":[]},{"id":"ci_f5b3dcec741813b33237d084eae01788c9ba5b4b40673255d7826ea90eebaa8b","title":"Time History Function","path":"/ideCAD/time-history-function","children":[]},{"id":"ci_adbfefcc25f871f985a814452abc34626a8e0189692ff6dbde9b12bd1a563060","title":"Time History Case","path":"/ideCAD/time-history-case","children":[]},{"id":"ci_f4004732e3ae19ba92e52e4d4179a7a794b18760a62a6233f1be5bf4c06c719f","title":"Load Combination","path":"/ideCAD/load-combination","children":[]}]},{"id":"ci_07e1fa651c901823be750c26e739abba8368c557d0d0ce98201fcc9c84a3315d","title":"Element Local Axes","path":"/ideCAD/element-local-axes","children":[]},{"id":"ci_5f4c0cc72c531d2a3b599201ca847fd1ba635cad2f913432cca45eb3510facee","title":"Local Axes of Shell Elements","path":"/ideCAD/local-axes-of-shell-elements","children":[]},{"id":"ci_69a3961936e601e58d83f5ff5740154b1aadffe1d63c9156ae336151f12d6534","title":"Rigid, Semi-Rigid, and Flexible Diaphragm Types","path":"/ideCAD/flexible-and-rigid-diaphragm-types","children":[{"id":"ci_9fff68e58ffaf35a0881bff0b3b9e27acaf4040291b864d338c30869f8168ea3","title":"Analysis and Concrete Design According to Diaphragm Acceptances","path":"/ideCAD/analysis-and-concrete-design-according-to-diaphrag","children":[{"id":"ci_a7152c026454760a1955354778b214ab2ebaefa99cb2ba82100cafda4eff9ab5","title":"Rigid Diaphragm Behavior","path":"/ideCAD/rigid-diaphragm-behavior","children":[]},{"id":"ci_2c5800a905fab32b9b780db20bb6b2fdb8d1f326a792277d163111c7c2f0dc81","title":"Semi-Rigid Diaphragm (Elastic Diaphragm) Behavior","path":"/ideCAD/semi-rigid-diaphragm-elastic-diaphragm-behavior","children":[]},{"id":"ci_879b95c09f094864e032663d8c1f7317d898c12e0c38bd90a6b20a48c5d6c344","title":"Flexible Diaphragm Behavior","path":"/ideCAD/flexible-diaphragm-behavior","children":[]},{"id":"ci_62f9db50c9cbdb27bef6ddad98202865b6a9003f29b671eae3d54f76533c3f1c","title":"Diaphragm Modeling According to Regulations","path":"/ideCAD/diaphragm-modeling-according-to-regulations","children":[]}]}]},{"id":"ci_9dc3f242fd214e08306ecd43ee5bf12680f6e58de9a4dad3bd93b47faf877bb5","title":"Creating an Analytical System","path":"/ideCAD/creating-an-analytical-system","children":[{"id":"ci_e1639ee84b5696dcf95535551b9a4b4d87f04950331073038413ce608d880c44","title":"Concrete Analysis Model","path":"/ideCAD/concrete-analysis-model","children":[{"id":"ci_35f5325a0bb70156725bc61be4ad99a8f06dfa41a90ed33d9c9729924c33fede","title":"Concrete Flexible Diaphragm Analysis Model","path":"/ideCAD/concrete-flexible-diaphragm-analysis-model","children":[]},{"id":"ci_688694c46d4b4b2b21e5723fc2d79945ced4cbcbd86cabe65bd65fd11558d1ce","title":"Concrete Rigid Diaphragm Analysis Model","path":"/ideCAD/concrete-rigid-diaphragm-analysis-model","children":[]}]},{"id":"ci_cd874a41acbab30e0e9aa373dd4c1c2c5852fa3dcffcd202d794c2ef55dce187","title":"Steel Analysis Model","path":"/ideCAD/steel-analysis-model","children":[{"id":"ci_37bac4320412230a8d1765e8b9c76d6a55deb23dc7d2aa0c57bb1af405684cd5","title":"Connection Types","path":"/ideCAD/connection-types","children":[]},{"id":"ci_a6e9368b9b6c1027e3da2f23e249b0550d22af84ae5041faab6f026f14e40bf7","title":"Releases","path":"/ideCAD/releases","children":[]}]}]},{"id":"ci_7341bff4fcf033a69bd3195ad58bd5358a08a4d2fc3abeb3f31443a9fe01ed84","title":"Center of Rigidity","path":"/ideCAD/center-of-rigidity","children":[]},{"id":"ci_5a8ea332d24a13d033ae4e276d037f20d8e21e70ca6aa2ed79a2bf56ca8e6590","title":"Overturning Moment Conditions","path":"/ideCAD/overturning-moment-conditions","children":[]}]},{"id":"ci_8d7c35259a3d20f011f3578d02ab8c564c0cd6717945fb4f603e465d2007a16d","title":"Structural Analysis","path":"/ideCAD/structural-analysis","children":[{"id":"ci_f8a333838b766fd1354254d17ca75557d803b62959d545625f0c1b64b84b04b4","title":"Analysis Settings","path":"/ideCAD/analysis-settings","children":[{"id":"ci_0abad6556687c8d12433bbcce059d34d21f6f8513b547346afe95706705dbc95","title":"Analysis Settings Based on Codes","path":"/ideCAD/analysis-settings-based-on-codes","children":[{"id":"ci_5af184935934686046afc9c436c71230d59d513e98346345e0fd59b344894108","title":"IBC International Building Code","path":"/ideCAD/ibc","children":[]},{"id":"ci_bf99c275db02db433719b12ce7dc1194f3daaaa053296620f83fe638612e7b9a","title":"UBC 97 Uniform Building Code","path":"/ideCAD/ubc-97","children":[]},{"id":"ci_1ca5f3521554f1f44e35e24ba77de2072812764d37be88b6c6c695fc56c7344d","title":"ASCE 7-16 Minimum Design Loads","path":"/ideCAD/asce7-16","children":[]},{"id":"ci_c27a8620b454c82da817f0d23a0c7b00e64bb588ee1c435f4ac5fe3d555c86f2","title":"TBDY 2018","path":"/ideCAD/tbdy-2018","children":[]},{"id":"ci_3ce73c30d6d82cf9141434abe2c3f2450a0aa2582cacfd8d5e3b22206226cbc2","title":"TDY 2007","path":"/ideCAD/tdy-2007","children":[]},{"id":"ci_0bcb00619c5fb16503af22b3c3e49259ca38df64c0bed8283e89219d84e04e6c","title":"SNI 1726-2019 Structural Design Requirements for Indonesia","path":"/ideCAD/sni-1726","children":[]},{"id":"ci_0b451c7ce4ac1eb7f5966eab861cc4f2417503ec0010413170f8ba88cad87b1c","title":"MOPC R-001","path":"/ideCAD/mopc-r-001","children":[]},{"id":"ci_2e83c6c74bd69fd34b43a7b9b0ad36bf81b237b4dd10d6f5367dbcd1808b1694","title":"DPT 1302-61 2019","path":"/ideCAD/dpt-1302-61-2019","children":[]},{"id":"ci_2b84442ecd1491126ea7c7739248956c0aada023bcc0393c1b07770e22d48239","title":"NSCP 2015","path":"/ideCAD/nscp-2015","children":[]},{"id":"ci_afc4e0edcb734ca5b415814d71c13c4f6c8ab0c1b6ff24bf3d44e7c29fe62c81","title":"BCP SP 2007","path":"/ideCAD/bcp-sp-2007","children":[]}]}]},{"id":"ci_38f77cf298ddee11554646e20781e0d52c9a0e6ed374a8d0d715797071bce9a3","title":"Story Parameters","path":"/ideCAD/story-parameters","children":[]},{"id":"ci_66d0ff0948bb2ece842517f31e2664b3a7ae44cab2a9444fa0b39b6e9ec05e1c","title":"Semi Rigid","path":"/ideCAD/semi-rigid","children":[]},{"id":"ci_b6c8b56e02bfbc4ab7e7bb7ad2933b8eff08d63f823d1be808c785cf08320a9b","title":"Analysis + Design (F9)","path":"/ideCAD/analysis-design-f9","children":[]},{"id":"ci_7ed280d9a4f90c0b4bb01ab86458b6daa288d8ed67ddf49d2b5f87bedd7780e0","title":"Slab Analysis","path":"/ideCAD/slab-analysis","children":[]},{"id":"ci_d3c173e2fcc56cb41436a5fb23771f159813a5b616cb2f44947bfeddaba91cea","title":"Stair Analysis","path":"/ideCAD/stair-analysis","children":[]},{"id":"ci_41533d17bbf8caf0f18376711a65ab7c782a3ec363e576cb93dec70fbb582321","title":"Pool Analysis","path":"/ideCAD/pool-analysis","children":[]},{"id":"ci_d92a983e9b3808d0212fe759cfa464fa9b5a7c1c35dad457cca597a284f4a0e9","title":"Dome Analysis","path":"/ideCAD/dome-analysis","children":[]},{"id":"ci_47ecb06ac9989e469bb17a1c0f0393e88dcc07959658365fe12b2268308be6d4","title":"Vault Analysis","path":"/ideCAD/vault-analysis","children":[]},{"id":"ci_183e21619fb82c1e64d97eb64f547b62fb6b60e584424a63ce31dd8fad2a6b4a","title":"Retaining Wall Analysis","path":"/ideCAD/retaining-wall-analysis","children":[]},{"id":"ci_b54a03f5d06a725b5f70aa395701cc17abf52cb3d68373d03e03c15d191fef55","title":"Well Foundation Analysis","path":"/ideCAD/well-foundation-analysis","children":[]},{"id":"ci_454562c6d40d9ee781d9a21d38c97a5fd1987f5fe2c092d2e78bb2b032c2a674","title":"Pushover Analysis","path":"/ideCAD/pushover-analysis","children":[]},{"id":"ci_ad797cec4826169109a113283e60d23fcf26b32196e56b8347f5d4922b5f12fd","title":"Linear Performance Analysis","path":"/ideCAD/linear-performance-analysis","children":[]},{"id":"ci_9c0b3f3ac9e8a247737cbd78029bb06298ba3917c5446dc32f0fa9d97fa5c8e2","title":"Structure Risky Analysis","path":"/ideCAD/structure-risky-analysis","children":[]},{"id":"ci_7abb4c3705a470a5a93472de5f90ed591ee94a3885950738eadf4e216be20686","title":"Time History Analysis","path":"/ideCAD/time-history-analysis","children":[]},{"id":"ci_c91f3190554217badad9e13eafe435cbf3c82ec99a5ff6b21e73c7ef888ffc62","title":"Euler Bucking Analysis","path":"/ideCAD/euler-bucking-analysis","children":[]},{"id":"ci_22146de6ba89d68152e988582f5611f787202abea841559fd7a3072efb4cd675","title":"Ground Motion Scaling in Time Domain","path":"/ideCAD/ground-motion-scaling-in-time-domain","children":[]},{"id":"ci_0627f343de1d6835368bc98ddade4689a1a235846231b434c3ec20f38c34b646","title":"GM Records for Mode Superposition","path":"/ideCAD/gm-records-for-mode-superposition","children":[]},{"id":"ci_abd04d8514da6e8a4c8bc295095946ffc75b85bda75005f91d8a123c7e847d30","title":"Generate Analysis System","path":"/ideCAD/generate-analysis-system","children":[]},{"id":"ci_93c21aa33f70acf5521a5ff645484b112d286a8b851567211eb60cca68041037","title":"Automatic Analysis System Generation","path":"/ideCAD/automatic-analysis-system-generation","children":[]}]},{"id":"ci_36c49f816b91c4faadaf591c3a22cd967bf6089a2a38a9e81f50653c2f80473a","title":"Earthquake-Resistant Design","path":"/ideCAD/earthquake-resistant-design","children":[{"id":"ci_12e075c7bf3e129eb0e8a4fa399665bdb8764da5fc050abb5b10921f3481bc29","title":"Seismic Design Criteria","path":"/ideCAD/seismic-design-criteria","children":[{"id":"ci_6a7943362032932a66dc31a94cc92c6ec4de4b8b66a53f2bd3d64e9ea9250329","title":"Earthquake Ground Motion Level.","path":"/ideCAD/earthquake-ground-motion-level-1","children":[]},{"id":"ci_72ff516b0488cb397ea18ca45044637052d156e7e70ae4c5818de12e17202a0d","title":"Site Class.","path":"/ideCAD/site-class-1","children":[]},{"id":"ci_fca3edb7ad528571ab4941f213636f4e0029023f13c296ea7c8763be6daeae15","title":"Spectral Response Acceleration Parameters","path":"/ideCAD/spectral-response-acceleration-parameters-1","children":[]},{"id":"ci_0d99605e82b350a8ea09be9be89a367b91086a018a7ba29e1a92be706279d32d","title":"Design Response Spectrum.","path":"/ideCAD/design-response-spectrum","children":[]},{"id":"ci_92170c0e2c3b3b1ac3bbb622648571568040788d16dda40bc2d5a3f7480b801c","title":"Vertical Response Spectrum","path":"/ideCAD/vertical-response-spectrum","children":[]},{"id":"ci_6dabadf190a94b4b78bcca14e983c5917ea0d0b34e587edb0099fd0a9d5d129d","title":"Importance Factor and Risk Category","path":"/ideCAD/importance-factor-and-risk-category","children":[]},{"id":"ci_a42398e75c079e163232c177442ccfb86e696757082858d2947a3ddeace8b805","title":"Seismic Load Effects and Combinations","path":"/ideCAD/seismic-load-effects-and-combinations","children":[]}]},{"id":"ci_e9cdccfa70acc8d9e413c75b4f1cad7a74e173704dc6518534397f06885f305b","title":"Seismic Design Requirements for Building Structures","path":"/ideCAD/seismic-design-requirements-for-building-structure","children":[{"id":"ci_12224d4e3b7c9f977cf4e15727e5c08780ce35424734b760299b4712853d530a","title":"Structural System Selection","path":"/ideCAD/structural-system-selection","children":[]},{"id":"ci_6f015022f8a1451b57f8b6c2b42c471a6af98229d2f0d36a55d101b8fd7d2bcf","title":"Analysis Procedure Selection","path":"/ideCAD/analysis-procedure-selection","children":[]},{"id":"ci_d23c9a997d7143226eb7b35310028dac052d03b24b567cfae5b5aa3cbd118991","title":"Modal Response Spectrum Analysis.","path":"/ideCAD/modal-response-spectrum-analysis-1","children":[]},{"id":"ci_b4a192723e75edfeb76afeb276638b3fd1bbfed599ccb6afa97d6fc633b1eae7","title":"Accidental Torsion","path":"/ideCAD/accidental-torsion","children":[]},{"id":"ci_503dc00f78be6ac70fa4ead911818060afad88011fe202d118ac300a691a0736","title":"Drift and Deformation","path":"/ideCAD/drift-and-deformation","children":[]},{"id":"ci_cf13682b07b469e3ccb692a641c551b26fe60089198921d35bc3483a4e1510f5","title":"P-Delta Effects (Second Order Effect)","path":"/ideCAD/p-delta-effects-second-order-effect","children":[]},{"id":"ci_ee36e4e2e38ccde5748fb647a4891da29d9e3d928acefddc719cd424c79dd08c","title":"Structural Irregularities","path":"/ideCAD/structural-irregularities","children":[]}]},{"id":"ci_4774612c9bb5b94789c958efeb9a4619106dc5bb8389d53bca569291f0619132","title":"Modeling Criteria","path":"/ideCAD/modeling-criteria","children":[{"id":"ci_1de9c1fdac325b7b776e71cf5bea27cb634dfded49255d27fe4487016d9197e7","title":"Foundation Modeling.","path":"/ideCAD/foundation-modeling","children":[]},{"id":"ci_7302069011e29d9ff8f2b2de6b1b069631d4101dd60d8c16b3af02f0cb4fcf4c","title":"Effective Seismic Weight","path":"/ideCAD/effective-seismic-weight","children":[]},{"id":"ci_4524a4da221e2a56895d359f9b459dcef27b9af59101ea0c002e577ce30f6b69","title":"Structural Modeling","path":"/ideCAD/structural-modeling","children":[{"id":"ci_e753d45ea742d49c853ab9b362579cfb782a42042b272258d1f790537da6f134","title":"Structural Modeling with Finite Element Method.","path":"/ideCAD/structural-modeling-with-finite-element-method-1","children":[]},{"id":"ci_fd4c79d7f66ecaf2026cea4bd9ffc53f005c6c215ea1d6f027d8166f741fe1ab","title":"Modeling of Shearwalls.","path":"/ideCAD/modeling-of-shearwalls","children":[]},{"id":"ci_e4911b7d19ecdc9ca24af81653eca5ef509b5e7a8fb3484c9134b2f549e034b9","title":"Modeling Story Slabs.","path":"/ideCAD/modeling-story-slabs-1","children":[]}]},{"id":"ci_38d656de6cb65ee2192048d02accc3642d7035a5ce445cc40ee3a49be6548c6c","title":"Damping Ratio.","path":"/ideCAD/damping-ratio-1","children":[]}]},{"id":"ci_7148b1a10c86c98ac5cab0aab651d231fc01a759b371bb362cebfd5c4cc1f348","title":"Wizard","path":"/ideCAD/wizard","children":[{"id":"ci_3ab2dce7a5bba37ea8547403b681a0ed869c8fdedadffea76875b3e6746c08e2","title":"Selecting Earthquake Ground Motion Level","path":"/ideCAD/selecting-earthquake-ground-motion-level","children":[]},{"id":"ci_91644e57bcc8af96cca9c7699108b9664e4653a183dfa189de9d741e03e3d606","title":"Site Classes","path":"/ideCAD/site-classes","children":[]},{"id":"ci_77c830ab6fbe380afbad1661f08d13363ac11ae58958966a3860a839576655ab","title":"Horizontal and Vertical Elastic Design Response Spectra","path":"/ideCAD/horizontal-and-vertical-elastic-design-response-sp","children":[]},{"id":"ci_616fdb3e0013fde909f187f27f55808a702c652de3d0aeaeaae62ef1cb940bd5","title":"Selecting Risk Category of Building and Importance Factors","path":"/ideCAD/selecting-risk-category-of-building-and-importance","children":[]},{"id":"ci_7bd8dc981f75cd4167141763ddd99a91efaeb606febb81a724e9ee71ad8fb489","title":"Seismic Design Category (SDC)","path":"/ideCAD/seismic-design-category-sdc","children":[]},{"id":"ci_763c5974b43a703e0dcd97cddfde4d1963ea5ea889d0858765d871ab059dab53","title":"Story Elevations","path":"/ideCAD/story-elevations","children":[]},{"id":"ci_3d6f99a8ec4b7127ca0722b7189b76fb4c98413a8f617e5b5ea5146d8f57a6ec","title":"Determination of Performance Target","path":"/ideCAD/determination-of-performance-target","children":[]},{"id":"ci_d407bca7e09719f42d438f7428b8a718292002f47486e9740010e923e7482078","title":"Selecting Structural System","path":"/ideCAD/selecting-structural-system","children":[]},{"id":"ci_972d1259f845eaa08d912e1a1ccd053214696198f8f7cde671e795aca72cf673","title":"Selecting Slab Type","path":"/ideCAD/selecting-slab-type","children":[]},{"id":"ci_05bdbc4bc48411072b0488c2ddf40a13fe5779fa4971f3fd1fb8cf4ccd2bfc6d","title":"Selecting Diaphragm Type","path":"/ideCAD/selecting-diaphragm-type","children":[]},{"id":"ci_fdb7e1365d4d37531b91652ff2b064a890b6432214d2cbe5a31cef0ac74ca19f","title":"Selecting Ductility Level","path":"/ideCAD/selecting-ductility-level","children":[]},{"id":"ci_90216b38ea59a5ea770a10116081919853ceb809467ffdb78b757565927128dc","title":"Design Coefficients and Factors for X Direction","path":"/ideCAD/design-coefficients-and-factors-for-x-direction","children":[]},{"id":"ci_0e21195af9a61d96590604cc7d975304febe2667a7c152b3babe1edf7d88d09f","title":"Design Coefficients and Factors for Y Direction","path":"/ideCAD/design-coefficients-and-factors-for-y-direction","children":[]}]}]},{"id":"ci_dcad206199ffb2970cf6eb53d11424301a86ebe2881b319aee770f9e2bc44d99","title":"Structural Design","path":"/ideCAD/structural-design","children":[{"id":"ci_e00efa61b6012496e7b2290be34fe6ac48304be4956cf506fb1401b9a2efd271","title":"Concrete Design Parameters","path":"/ideCAD/concrete-design-parameters","children":[{"id":"ci_7959cce44b803752121243427591a3c93efc3961a977df5c80e11122c23cae15","title":"Rebar Selection","path":"/ideCAD/steel-bar-selection","children":[]},{"id":"ci_ad518d3303cd2331da74ddb0be1e869f63ba050a783ae682de2365c0fe082b8d","title":"Mesh Wire Settings","path":"/ideCAD/mesh-wire-settings","children":[]},{"id":"ci_781ab43bfbda783bee9940e533f0a4fe95b0b1f068fbf1506b60abafa92e755d","title":"General Concrete Reinforcement Parameters","path":"/ideCAD/general-concrete-reinforcement-parameters","children":[]},{"id":"ci_27ecaeed44544934a10d76a26a541e2ee2844b88971c3910552812a9baf43f77","title":"Column Parameters","path":"/ideCAD/column-parameters","children":[]},{"id":"ci_f4181558cee8e3561fb2b4d2b506b15cb10c699292271b8ef1ec78a60c9f4c26","title":"Beam Parameters","path":"/ideCAD/beam-parameters","children":[]},{"id":"ci_00644c843425584548edc0361a948cdc7ed9fbddab27b3471d8554a0c009bf0b","title":"Shearwall Parameters","path":"/ideCAD/shearwall-parameters","children":[]},{"id":"ci_18b9c4e322ec32217a7bac1b4ddae7d51936d3eac36c522368b7d79a903fb1c8","title":"Slab Parameters","path":"/ideCAD/slab-parameters","children":[]},{"id":"ci_bc9c755aacca195c86f281a27f1f6655eb97246ec8e1ab3123d08b3786c68ae4","title":"Ribbed-Waffle Slab Parameters","path":"/ideCAD/ribbed-waffle-slab-parameters","children":[]},{"id":"ci_5d1032d1eb771b4c3deaf2b6dce92af03a776760b5a61523bcd28c39d35f4ae8","title":"Single Footing Parameters","path":"/ideCAD/single-footing-parameters","children":[]},{"id":"ci_9f265ff6345d3cf14ec15f0c360612f071eb09a70b9d56219118797f29198bb0","title":"Strip Foundation Parameters","path":"/ideCAD/strip-foundation-parameters","children":[]},{"id":"ci_81df5c133712c5e08eef763211ab49e514c29dff3074ae86e9153af2b36f7e32","title":"Raft Foundation Parameters","path":"/ideCAD/raft-foundation-parameters","children":[]},{"id":"ci_d5dae3aec9c9ed9753598a00f2b62975fe426e98e900696819975390e9f02fc7","title":"Stair Parameters","path":"/ideCAD/stair-parameters","children":[]},{"id":"ci_6d6dab141cb8cfc2ea6afa3ac889480a1b9ddc0e859ef2e9169b78857966a0fa","title":"Dome Vault Parameters","path":"/ideCAD/dome-vault-parameters","children":[]},{"id":"ci_742125b8fb1cf8ad2429c56e02e53db6231539ac288579dfd2dd2cafb1684fd4","title":"Retaining Wall Parameters","path":"/ideCAD/retaining-wall-parameters","children":[]},{"id":"ci_9a53ba3ccb9e76215fe35081b4f27c6247b2d28a8144e20842526d5c5ea3776f","title":"Well Foundation Parameters","path":"/ideCAD/well-foundation-parameters","children":[]},{"id":"ci_a8c28bb8e88468301d21a45a887bde20ca00f57681d137b6f79396d3266ca52e","title":"Pile Parameters","path":"/ideCAD/pile-parameters","children":[]},{"id":"ci_521fc190dfed52b3b13588e9c0388b4223815f0762064fa4747348dc3df0ff43","title":"Foundation Tie Parameters","path":"/ideCAD/coupling-beam-parameters","children":[]}]},{"id":"ci_9b6c46f9e96b591400c764eae2524e4f14d87ab56357f3141ba747c673bd4a2a","title":"Have You Tried This While Modeling Concrete Building?","path":"/ideCAD/have-you-tried-this-while-modeling-concrete-buildi","children":[{"id":"ci_a9a39558e37fc05f69816b459ee59976f417fde9b5c4687167aa1f53d2f71d1f","title":"When All Failures are Active","path":"/ideCAD/when-all-failures-are-active","children":[]},{"id":"ci_0d166bbcb72b700a187274b4fec33ca8c957a4856e7b746704b022751ff4a6cf","title":"Adding a Short/Head Shearwall","path":"/ideCAD/adding-a-short-head-shearwall","children":[]},{"id":"ci_b31704db0a988c8f1671b0e3428dd651ed4bd245c7b79422a3333ec1fb9295c9","title":"Open the Elements Design Dialog","path":"/ideCAD/open-the-elements-design-dialog","children":[]},{"id":"ci_cae6f104ab36c6f47125c3e427501253971c101eabbb038b462de7e3f4d95f01","title":"Stories That Will Not Join The Building Height","path":"/ideCAD/stories-that-will-not-join-the-building-height","children":[]},{"id":"ci_ba7aa37d9ef3834e27ef8cc8a5e5f88ea9f64d38578120256c888cc4a813e672","title":"Selecting Multiple Lines in the Design Dialog","path":"/ideCAD/selecting-multiple-lines-in-the-design-dialog","children":[]},{"id":"ci_9d7ca5491163adf1e2addc23b6bad8af5d46ec66331d4bfcd3b33839e3179522","title":"Area of Steel Calculator","path":"/ideCAD/area-of-steel-calculator","children":[]},{"id":"ci_7addc3f4ed9dcc1c99429d20a97ecb71ae64498a083f48103424242d51b8cd3d","title":"Choosing an Environmental Exposure Class","path":"/ideCAD/choosing-an-environmental-exposure-class","children":[]},{"id":"ci_11165d543cc9465fb3dc2d0560f1ab4ae6c0110d395a9a50805d2a81ea4ac3e6","title":"Mark as Secondary Axis","path":"/ideCAD/mark-as-secondary-axis","children":[]},{"id":"ci_d7e19ab74c9205fdf3466c98d9b0a262b77effaf58d15971207c0e23cd85a93f","title":"Drawing of Shearwall Horizontal Body Steel Inside/Outside with Bend","path":"/ideCAD/drawing-of-shearwall-horizontal-body-steel-inside-","children":[]},{"id":"ci_0658f56125d06e96e5f56e4b2ab0a3d871440e7c187a48e8198ccc28688bd18f","title":"Naming for B420C or S420","path":"/ideCAD/naming-for-b420c-or-s420","children":[]},{"id":"ci_10e4a36f26f7ba5168bf4cf18c9906e4f3fe9d4005a85199adb355e57214eaba","title":"Period Check for Rigid Basement Assumption","path":"/ideCAD/period-check-for-rigid-basement-assumption","children":[]},{"id":"ci_8545096577beb6b9d810d72d2e13084ef96dcd4b903294880e4ec93063ffd7ee","title":"Filtering Design Input Information as a Color Palette","path":"/ideCAD/filtering-design-input-information-as-a-color-pale","children":[]},{"id":"ci_1aaba6ff64419ba061d6db393139cad6ca7d2769850758ad74a8bab20e2984d5","title":"Rebar Numbering Options","path":"/ideCAD/rebar-numbering-options","children":[]},{"id":"ci_daced12ed910ff70be235d5a6a86d08916dba643bcba64a3c6a8a5047da7c5ff","title":"Solid Model/Vertical Frame in Analysis Model","path":"/ideCAD/solid-model-vertical-frame-in-analysis-model","children":[]},{"id":"ci_4a81e6178db209948142c12af0fc7d5c66a46ab837493016b89605a154faed85","title":"Color and Hatch for Shearwall Head Regions","path":"/ideCAD/color-and-hatch-for-shearwall-head-regions","children":[]},{"id":"ci_89e81be1ad6cacd9f55cc5ecfcd39c8c70605c3d7b06720ab256425646d0c2c3","title":"Project Errors in the Report","path":"/ideCAD/project-errors-in-the-report","children":[]},{"id":"ci_41603bdfa6d67c78ab89795adde284d736dca41c361037c3e3af43923097e621","title":"Design Beams With/Without Bend Up Bars","path":"/ideCAD/design-beams-with-without-bend-up-bars","children":[]},{"id":"ci_b8bce41c78833b80ba3a6ed464c62e884e914f411616e673cfcf59bf61e17659","title":"Beams/Shearwalls Continuous if Angle is Less Than","path":"/ideCAD/beams-panels-continuous-if-angle-is-less-than","children":[]},{"id":"ci_b3233c4c95ac2d43169be66f03f483c24fc4679e9cf816f02b26684f161da9d2","title":"Preparing Geotechnic Report","path":"/ideCAD/preparing-geotechnic-report","children":[]},{"id":"ci_6bd6e2bff749c6b428a268e9e07f23f146179005f20600e314b55a0a819a74e7","title":"Unit Icons","path":"/ideCAD/unit-icons","children":[]},{"id":"ci_632f5c755788b3afb716ae979ca62c1b763035d7f83c516622444da922080dab","title":"Reinforcement Chair Features","path":"/ideCAD/chair-rebar-features","children":[]},{"id":"ci_23854b92a7b6c572c4831f390967ee99a38e2d8d4611a5090a9424b2029df7f3","title":"Separate Index for Each Story","path":"/ideCAD/separate-index-for-each-story","children":[]},{"id":"ci_be018183d20daf15bd9e221ca5bfe1e44943c7638423d6882f6fba73d6382fb8","title":"Adding Load to Column, Beam and Shearwall","path":"/ideCAD/adding-load-to-column-beam-and-shearwall","children":[]},{"id":"ci_6c25b049c6fdfba452170b0db3763de85ae35df63bf10f112073d567b14ceb75","title":"Changing Concrete Calculation Line Geometry","path":"/ideCAD/changing-concrete-calculation-line-geometry","children":[]},{"id":"ci_eebfdde37d08a65e10c3ea7dbd2bb02874ddfd9b375dbc23f12ff065d06cb1fa","title":"Reinforcement Calculator","path":"/ideCAD/reinforcement-calculator","children":[]}]},{"id":"ci_30d8440347acba22edf0ed2f821635e97216e418a79d8a627e31588ba54c14b7","title":"Concrete Design Result Dialogues","path":"/ideCAD/concrete-design-result-dialogues","children":[{"id":"ci_119564ee43399ea6404baa35128699a1524b947630764818fdba62331f182721","title":"Slab Reinforcements","path":"/ideCAD/slab-reinforcements","children":[]},{"id":"ci_2253358fce7dae58a810cefde1e90349e97a20d833ef36960247a4eb0430fca2","title":"Ribbed-Waffle Slab Reinforcements","path":"/ideCAD/ribbed-waffle-slab-reinforcements","children":[]},{"id":"ci_10fb1e045d8944e1725cd567c6385d2ea667efd114d7db88a3e74a3e46e3c676","title":"Slabs With Mesh Wire","path":"/ideCAD/slabs-with-mesh-wire","children":[]},{"id":"ci_1566a093cde461ed46020759915b3d8ac0dec89299f138386eb1283547d71d98","title":"Beam Reinforcements","path":"/ideCAD/beam-reinforcements","children":[]},{"id":"ci_f3ccc6bb62f80ea3f7da066c7cc2063ba46812f2301b43f1d3449444339d0ea7","title":"Column Reinforcements","path":"/ideCAD/column-reinforcements","children":[]},{"id":"ci_44c941f270b3675f273875aff98be961f5832b05915620179b57943c770e70e4","title":"Column/Shearwall Punching Design","path":"/ideCAD/column-shearwall-punching-design","children":[]},{"id":"ci_e09694aa38e66be56c85c7a10bbc4f17d97d00c176afb18fa8c386312d73c9b6","title":"Shearwall Reinforcements","path":"/ideCAD/shearwall-reinforcements","children":[]},{"id":"ci_4bdcec87153311de6387ca80cb02fd259185591474578b378fbea6cd4059959c","title":"Shearwall Core Reinforcements","path":"/ideCAD/shearwall-core-reinforcements","children":[]},{"id":"ci_f8b25199f5f0e4d22574a4aeb43046c82cdfcd9650b864eecbc3a7cec2443322","title":"Raft Foundation Reinforcements","path":"/ideCAD/raft-foundation-reinforcements","children":[]},{"id":"ci_01d4f96e992b3394df1bd9094b385677425bd1d7152cd3b748df666a9139225a","title":"Strip Foundation Reinforcements","path":"/ideCAD/strip-foundation-reinforcements","children":[]},{"id":"ci_f607509da49665626b62b0884044c5382caeece833d68ddc4b52a3b464b0e0a5","title":"Single Footing Reinforcement","path":"/ideCAD/single-footing-reinforcement","children":[]},{"id":"ci_3d854e6d12446252746042806077d15bbf8478dd5826ec7d650bebf344632d3b","title":"Foundation Tie Reinforcements","path":"/ideCAD/coupling-beam-reinforcements","children":[]},{"id":"ci_3b1c8c8a0c3b52b5098c84b81e5385175898375b368d02d992e81e578490c64e","title":"Stair Reinforcements","path":"/ideCAD/stair-reinforcements","children":[]},{"id":"ci_ef7ece04315b1c4156333f8ed24628837324708c663476692f655249dbd14dbe","title":"Pile Reinforcements","path":"/ideCAD/pile-reinforcements","children":[]},{"id":"ci_39638b4151f72b6a17731ed8991fffa04fa038335139249723db0526decfbde3","title":"Dome Reinforcements","path":"/ideCAD/dome-reinforcements","children":[]},{"id":"ci_6d8632d11469546f7914b3fe03b8d09619dcacb28ce84aa38d12b458f0bc059e","title":"Well Foundation Reinforcements","path":"/ideCAD/well-foundation-reinforcements","children":[]},{"id":"ci_f87a4dac71ef6714100f3fef8ed77c428cfad94b0b82b9bdbb651862ae1e7df0","title":"Retaining Wall Reinforcements","path":"/ideCAD/retaining-wall-reinforcements","children":[]}]},{"id":"ci_9085074a92fdbe0d4d16cddfa17c4cf4ca6cd5e72330bd17744d64af22de47b2","title":"Steel Design Result Dialogues","path":"/ideCAD/steel-design-result-dialogues","children":[{"id":"ci_44a57369fe609369b182d89b931fd01aa8ff2ff12978282e1a65aed504aedf96","title":"Steel Column Design Results","path":"/ideCAD/steel-column-design-results","children":[]},{"id":"ci_8d1b62c5262640c40fe7e73df32607365456cadbc81d2391503ab916e83a52e3","title":"Steel Beam Design Results","path":"/ideCAD/steel-beam-design-results","children":[]},{"id":"ci_f72d7d3d2a097f4dc585e0aefbb26beeb3b015c2268d380d3b40ecb022a92029","title":"Secondary Beam Design Results","path":"/ideCAD/secondary-beam-design-results","children":[]},{"id":"ci_1130f52fab3a242cfa35650d984ea95752248f404f706c9431b05d2328d4eafd","title":"Composite Castellated Beam Results","path":"/ideCAD/composite-castellated-beam-results","children":[]},{"id":"ci_63fc4e97ec4c63975f4f33d65b3242deb0c27cc9caa1114eead652adf6a34ed9","title":"Noncomposite Castellated Beam Design Results","path":"/ideCAD/noncomposite-castellated-beam-design-results","children":[]},{"id":"ci_c15d098f5efd3bc1aadb719aa05d012b9ce379f5ee7669d27d4cceec67d2dc3a","title":"Composite Beam Design Results","path":"/ideCAD/composite-beam-design-results","children":[]},{"id":"ci_7079f0a1ff93049bb226e5b4342a213d7b01807e1536b1bd64bd019cce01d369","title":"Crane Beam Design Results","path":"/ideCAD/crane-beam-design-results","children":[]},{"id":"ci_4b85efeae60d49ed8d42dc29a41a0801e9086a8711fc55be7037d4114e261840","title":"Purlin Design Results","path":"/ideCAD/purlin-design-results","children":[]},{"id":"ci_8e0ef60abee66bcdb715cac6cebdd0553ac751a14e219180db2813c1abe0dfc9","title":"Brace Design Results","path":"/ideCAD/brace-design-results","children":[]},{"id":"ci_6c5d574289ad9636c817088ba014af388666133e8f34871afa927c7419a2424f","title":"Truss Design Results","path":"/ideCAD/truss-design-results","children":[]},{"id":"ci_bb0dcf603c65c6cdcfb204d2773bd052a6d6e802fcf92a171ea46e0e748c3c08","title":"Space Truss Design Results","path":"/ideCAD/space-truss-design-results","children":[]},{"id":"ci_e8bed312b0d1ede7166268cc9d9c5d1f820e524f153b73fe2169a1786f40abd5","title":"Steel Joist Design Results","path":"/ideCAD/steel-joist-design-results","children":[]},{"id":"ci_8f27bf218f70962c2a5d559ef70b1a804717a639541ead2b7162c700e67bbf22","title":"Space Purlin Design Results","path":"/ideCAD/space-purlin-design-results","children":[]},{"id":"ci_2a82e1be048944360ac8c557f1a6ed2b2e9d5028658ab2f0bcf1d9a402b5bcd0","title":"Connection Design Results","path":"/ideCAD/connection-design-results","children":[]},{"id":"ci_1eb50b67b93a4ec724e6c42f39302900898eb634d2732b9feb2108cfae30eb1c","title":"Moment Resisting Frames","path":"/ideCAD/moment-resisting-frames","children":[]},{"id":"ci_49746237a63947ca87c63497d08fea188f4295581c3d5a44a00a6171a43a67ec","title":"Concentrically Braced Frames","path":"/ideCAD/concentrically-braced-frames","children":[]},{"id":"ci_2bef2e719516aebf8755fb481691dc34184578faf53e0eb0a105fb6c2a41a750","title":"Clash Check","path":"/ideCAD/clash-check","children":[]}]}]},{"id":"ci_d8de6121e4706960d27c492af3910ffa02e518f585391f6b90c44d41f2c4f025","title":"Concrete Design","path":"/ideCAD/concrete-design","children":[{"id":"ci_619f39158ac729b8efb229d9c1a170412c1b05708616fc73bb57759dc670b729","title":"Materials and Reduction Factors.","path":"/ideCAD/materials-and-reduction-factors-1","children":[]},{"id":"ci_dc8f36f242f218cd03739e998315d78a68f29be5e033940fbafcf8ef099a1dce","title":"Load Factors and Combinations.","path":"/ideCAD/load-factors-and-combinations-1","children":[]},{"id":"ci_7afa072313e2b2b140360263494395c15bca457bade92ff030e9f83d37dfee0b","title":"Sectional Strength.","path":"/ideCAD/sectional-strength-1","children":[{"id":"ci_b4907528e4ea2755bae096f36a0919b3b85f7ea147af8771949fd7302d130018","title":"Flexural Strength.","path":"/ideCAD/flexural-strength-1","children":[]},{"id":"ci_2eca62dfd2164597bcd5fb96f1e7cfb590192e1bf1a6be0d84a1c943ce3499f6","title":"Axial strength or Combined Flexural and Axial Strength.","path":"/ideCAD/axial-strength-or-combined-flexural-and-axial-st-1","children":[]},{"id":"ci_de90cc46f229ab2390c9e7f00f3d60207b5d8760fb6595b47cbe5e531a8c1df0","title":"One-Way Shear Strength.","path":"/ideCAD/one-way-shear-strength-1","children":[]},{"id":"ci_fcd224cb19a8b6ca229836a00754590d57c07b27b86b8f37111da525b2320ee0","title":"Two-Way Shear Strength.","path":"/ideCAD/two-way-shear-strength-1","children":[]},{"id":"ci_cbc6d2906006dffd66838c484378196c4a5058212543cf15ea94d94daafbd2ef","title":"Torsional Strength.","path":"/ideCAD/torsional-strength-1","children":[]}]},{"id":"ci_1c02caa956c95f0f1b72aea5c70c59d3cf975418cba12039c73c758a55ac1be5","title":"Reinforcement Details.","path":"/ideCAD/reinforcement-details-1","children":[{"id":"ci_a4e7d34fd4b1c6c5cb9779ea98b49f77eb38e466418281a04a51a22041d2370b","title":"Minimum Spacing of Reinforcement.","path":"/ideCAD/minimum-spacing-of-reinforcement-1","children":[]},{"id":"ci_5900246176047477462866eb81cb5e22c30e6b410926344095e4ea26e0dab286","title":"Standard Hooks, Seismic Hooks, Crossties, and Minimum Inside Bend Diameters.","path":"/ideCAD/standard-hooks-seismic-hooks-crossties-and-minim-1","children":[]},{"id":"ci_39f0838e76e383ec74c30e8103e5da5a66c53472330df8316937c6cff9f9e822","title":"Development of Reinforcement.","path":"/ideCAD/development-of-reinforcement-1","children":[]},{"id":"ci_e1e6fdcdced8c906647a83aea102c80a4a4e6d6cb56cadd99347898c5e1232b6","title":"Splices.","path":"/ideCAD/splices-1","children":[]},{"id":"ci_bffb8ea97cc03b311f26ef1d9e8bcaa6f64a63b9aeb67b98ca71dcda34d0293d","title":"Stirrups.","path":"/ideCAD/stirrups-1","children":[]},{"id":"ci_6b434b6407a94f3ab96d6dc96ea02e13a161a3e4fa1e9c989291a02a32f869aa","title":"Transverse Reinforcement.","path":"/ideCAD/transverse-reinforcement-1","children":[]}]},{"id":"ci_94c657549561494e7d40c64c477c347501953369b2089685e72ee2b96071e72f","title":"Concrete Column Design.","path":"/ideCAD/concrete-column-design-1","children":[{"id":"ci_f008fbef23b1f8d03cb40c878c7b50d6834c3cbcce0215c86597c7610ccfdf34","title":"Column Design Limits.","path":"/ideCAD/column-design-limits-1","children":[]},{"id":"ci_54264a232f38f3630e4473189a6670dcb2d7f48cf62b2b785edcc1d593bd4a46","title":"Column Required and Design Strength.","path":"/ideCAD/column-required-and-design-strength-1","children":[{"id":"ci_ecdba028916a9a1513f88a190de481dd643c2f7b3a3229e7f0fcfe4c4928997e","title":"Column Combined Flexural and Axial Design.","path":"/ideCAD/column-combined-flexural-and-axial-design-1","children":[]},{"id":"ci_6fa104d1d6f7db2585bbdd8d94a3fb3ef1dd9eda55e8a622b593246c7182e635","title":"Column Shear Design.","path":"/ideCAD/column-shear-design-1","children":[]},{"id":"ci_bd62d5dee854c92cdff2fc671e52199aa63921d54ed4ce226970d73197084a64","title":"Minimum Flexural Strength of Columns.","path":"/ideCAD/minimum-flexural-strength-of-columns-1","children":[]}]},{"id":"ci_8443ddf8633eeb42d75b20c3aaa310730114eab93d5c96a5a863109e1fae3038","title":"Column Reinforcement Limits.","path":"/ideCAD/column-reinforcement-limits-1","children":[]},{"id":"ci_e381804b5047b007029632f9b96753a24f4a2269ab7b21dc1a8a6ffa56d31ca8","title":"Column Reinforcement Detailing.","path":"/ideCAD/column-reinforcement-detailing-1","children":[{"id":"ci_ac6cd6ba871d5dd0c3c6e792aab63975dd8182e18e8c3d432f8ccc12a5da04e5","title":"Longitudinal Reinforcement Detailing.","path":"/ideCAD/longitudinal-reinforcement-detailing","children":[]},{"id":"ci_c744d734be1339324ccf223f052e41c999f3cb849fb4b7919fb96f6ff1038847","title":"Transverse Reinforcement Detailing","path":"/ideCAD/transverse-reinforcement-detailing","children":[]}]}]},{"id":"ci_b55a607135a816f16a8ce09bf2afd791d4419502c5292ed97545dd5576b4b111","title":"Concrete Beam Design.","path":"/ideCAD/concrete-beam-design-1","children":[{"id":"ci_6b2f892ab354e538138fec6a80dc8c5fab1a0735b926fb4817d3a1301fc425c2","title":"Beam Stability.","path":"/ideCAD/beam-stability-1","children":[]},{"id":"ci_b1b0f90ce2bee211d35dc9445620cae553f1956f0e36471f81ba46d271e43fc3","title":"Beam Design Limits.","path":"/ideCAD/beam-design-limits-1","children":[]},{"id":"ci_b7c9ef827b892c5855d0e91e4628737bbc7a5f8fc37bb851e136afc0bbab8cf9","title":"Beam Required and Design Strength.","path":"/ideCAD/beam-required-and-design-strength-1","children":[{"id":"ci_e0058d83057d7b097e305778c16c2740d09a62b7bc4592843e00b23509c0db8f","title":"Beam Flexural Design.","path":"/ideCAD/beam-flexural-design-1","children":[]},{"id":"ci_c7dcef46f29c809f8699cb60aea4d55dcdf3055ad72195d1fb5958aea4da9ec8","title":"Beam Shear Design.","path":"/ideCAD/beam-shear-design-1","children":[]}]},{"id":"ci_9b1f5ad395dae36f12f6c3172913f7b9dec80edfa78657df9875d6ee6e9685da","title":"Beam Reinforcement Limits.","path":"/ideCAD/beam-reinforcement-limits-1","children":[]},{"id":"ci_7a2896a7f97bd4f46b168292ec37e6ff0c110002692a65e5ed5122503b063b50","title":"Beam Reinforcement Detailing.","path":"/ideCAD/beam-reinforcement-detailing-1","children":[{"id":"ci_98651a902d1435a62f893ed0bf6d7a46a77a25783f82bdf38706fc13385c5267","title":"Flexural Reinforcement Detailing (BRD)","path":"/ideCAD/flexural-reinforcement-detailing-brd","children":[]},{"id":"ci_b9e245affc9aab5a310488b0a3854f7af4d608fb1f5f1605f3773dc386a11136","title":"Transverse Reinforcement Detailing (BRD)","path":"/ideCAD/transverse-reinforcement-detailing-brd","children":[]}]}]},{"id":"ci_e12798c16bc34eb6551aca7d11a4672a37d1284fe6fffe7d50f796f6656968ee","title":"Concrete Beam-Column Joint Design.","path":"/ideCAD/concrete-beam-column-joint-design-1","children":[{"id":"ci_afeb215e3f4b09785f436aeb81e9b8d3a703138d10ed25fbbfba3f33bd90f927","title":"Joint Shear Strength.","path":"/ideCAD/joint-shear-strength-1","children":[]},{"id":"ci_c684467dccb1dd6a1b49394a884ac69fecc5dac61619cb5f16d4f412a926337c","title":"Reinforcement Detailing of Joints.","path":"/ideCAD/reinforcement-detailing-of-joints-1","children":[]},{"id":"ci_c26a4a5bfd0acff4c47d8d074b1552fef33d1812585207ea47b840f6135ef93f","title":"Beam-Column Flexural Capacity Ratios.","path":"/ideCAD/beam-column-flexural-capacity-ratios-1","children":[]}]},{"id":"ci_6ac34a2944087d7263f162ad831c696432d823ab7c18aecb84573690996c87d0","title":"Concrete Shear Wall Design.","path":"/ideCAD/concrete-shear-wall-design-1","children":[{"id":"ci_e8d9c60a784aaf003470692e0dda13a0491955a40031a86f767d3b8dfde2ab44","title":"Shear Wall Design Limits.","path":"/ideCAD/shear-wall-design-limits-1","children":[]},{"id":"ci_1dda482f769e8a3062a6130a9eed056842f874d989caac29a8db06982d215462","title":"Shear Wall Required and Design Strength.","path":"/ideCAD/shear-wall-required-and-design-strength-1","children":[{"id":"ci_bb66944fa18ad075b4e99daacb11c4a60545554567b85366bc5d7d9af03c1216","title":"Shear Wall Combined Flexural and Axial Design.","path":"/ideCAD/shear-wall-combined-flexural-and-axial-design-1","children":[]},{"id":"ci_75f56ef3deab73cd661f6ed06c9a03b51295a060832402b16e383f93d38a06cc","title":"Shear Wall Shear Design.","path":"/ideCAD/shear-wall-shear-design-1","children":[]}]},{"id":"ci_adc90ac90475ba73eccdc6cce2ffc48661e1145a4634418678c815dfcffc2de1","title":"Shear Wall Reinforcement Limits.","path":"/ideCAD/shear-wall-reinforcement-limits-1","children":[]},{"id":"ci_59d8d6df6ca20640b6343363d2aa2442ac425e95fc2bc52f5bc7cad486817f47","title":"Shear Wall Reinforcement Detailing.","path":"/ideCAD/shear-wall-reinforcement-detailing-1","children":[{"id":"ci_2c8bfbded3fcdba482251cdf45edb6a92638fd1f5281e2818bd0bdce6c13d1cc","title":"Longitudinal Reinforcement Detailing (SwRD)","path":"/ideCAD/longitudinal-reinforcement-detailing-swrd","children":[]},{"id":"ci_e76e07c43e06ab406543b50ffb38d046f36c13daf68f26480a95d929d5a9d819","title":"Transverse Reinforcement Detailing (SwRD)","path":"/ideCAD/transverse-reinforcement-detailing-swrd","children":[]}]},{"id":"ci_0ec3dffdeedc9ef52a3f2d321d329f4ca8f1126855b3fd73792dbd6a3736f52d","title":"Boundary Elements of Special Structural Walls.","path":"/ideCAD/boundary-elements-of-special-structural-walls-1","children":[]},{"id":"ci_d3affaf420ea360dd23922754e26bcd7e832e26de9144e7ef84f1ec935a9ea4e","title":"Coupling Beam Design.","path":"/ideCAD/coupling-beam-design-1","children":[]}]},{"id":"ci_41109831ce1f0fa230d69af239a1526eaea2acca9be2a7d11f6c7cf149234e76","title":"Concrete Slab Design.","path":"/ideCAD/concrete-slab-design-1","children":[{"id":"ci_d724812b8d67f8469856b1564a14dc28c5cc9a13bb751497d9fae17d0a72c8d0","title":"One-Way Slab Design.","path":"/ideCAD/one-way-slab-design-1","children":[{"id":"ci_80904a386a59bbf9f788912d21264df2994e4661e4a495bae80418bf5fcc9810","title":"One-Way Slab Design Limits.","path":"/ideCAD/one-way-slab-design-limits-1","children":[]},{"id":"ci_3c0e5d802d65e130d7c315335bfbef5d2a7e94b807720518bee04cf47ba0fe22","title":"One-Way Slab Required Strength.","path":"/ideCAD/one-way-slab-required-strength-1","children":[]},{"id":"ci_52b919fd3c4914c84332ea67d0a3afb63c27ecf3ef119ef4ef96e8f106c114fa","title":"One-Way Slab Design Strength.","path":"/ideCAD/one-way-slab-design-strength-1","children":[]},{"id":"ci_106b86dfa92d5ac230c5bbd26a2b67085d935b37a8448d5f2bfda97e92043a8c","title":"One-Way Slab Reinforcement Limits.","path":"/ideCAD/one-way-slab-reinforcement-limits-1","children":[]},{"id":"ci_6ca47be8fb32b92debc75dd2b690e3c5550156151e9bd7ec12baab8efdb1d712","title":"One-Way Slab Reinforcement Detailing.","path":"/ideCAD/one-way-slab-reinforcement-detailing-1","children":[]}]},{"id":"ci_2c1c5dc9bc51786044ac42ee5fa45a4ee23ce54a974a5653d541cb1f98a48b63","title":"Two-Way Slab Design.","path":"/ideCAD/two-way-slab-design-1","children":[{"id":"ci_42283373fbd1f9f1e51c11c3421f97e278de5593508e668f03fc6182ed1afcc5","title":"Two-Way Slab Design Limits.","path":"/ideCAD/two-way-slab-design-limits-1","children":[]},{"id":"ci_61f07cfa5b5b1cb7a927f1c452026abab10d96d5618b84afbf5874f1dd89584a","title":"Two-Way Slab Required Strength.","path":"/ideCAD/two-way-slab-required-strength-1","children":[]},{"id":"ci_4be91cc0db6e9c897a04f89d954050e4630849b2817ef4c8c4860df048384840","title":"Two-Way Slab Design Strength.","path":"/ideCAD/two-way-slab-design-strength-1","children":[]},{"id":"ci_7c92dac266cbbb415007c0ae67cd47c0217720d771aa2fea11aceb44ffc7f911","title":"Two-Way Slab Reinforcement Limits.","path":"/ideCAD/two-way-slab-reinforcement-limits-1","children":[]},{"id":"ci_4054471fdfa35fbfef7e67cb329e45c04808de7526bce5926de4089676bea089","title":"Two-Way Slab Reinforcement Detailing.","path":"/ideCAD/two-way-slab-reinforcement-detailing-1","children":[]}]},{"id":"ci_0ad6e23ec519783d8e3e3cf121e5e6b3ee3ccc50a63f1e008523a87109c3520d","title":"Nonprestressed two-way joist systems (Waffle Slabs).","path":"/ideCAD/nonprestressed-two-way-joist-systems-waffle-slab-1","children":[]},{"id":"ci_b40980fac21fc50e438455f2b5c64b141813c9783296f8a0495785a097ac086f","title":"Punching Shear Design","path":"/ideCAD/punching-shear-design-1","children":[]},{"id":"ci_33ed3463a1609c217f4160dd7660be5a4cdc64c6e63d820baf3e94c25720b99a","title":"Diaphragm Design of the Seismic-Force-Resisting System.","path":"/ideCAD/diaphragm-design-of-the-seismic-force-resisting--1","children":[{"id":"ci_b16ed4522ca523737f98bf1a2e9007ee071ca3a2592166b93a72a856fc8261cc","title":"Design Limits.","path":"/ideCAD/design-limits-1","children":[]},{"id":"ci_527db0544ba2a49cdb93dfe4fc39fde4448bb67227619d06105e97eb85d8202e","title":"Required Strength.","path":"/ideCAD/required-strength-1","children":[]},{"id":"ci_b50112ce5e24a4018fd7770dcc9221464460a2a38d56e283efe3931ab6668d7f","title":"Design Strength.","path":"/ideCAD/design-strength-1","children":[]},{"id":"ci_99bc35a59126934b134abf359be096b7a6b1c35439fa66cc0d971baa1d714b8f","title":"Reinforcement Limits.","path":"/ideCAD/reinforcement-limits-1","children":[]},{"id":"ci_dbd7261c8f0c4982b55690a04a17e58b20124b54bc5ced80491d0862d6a2ab4e","title":"Reinforcement Detailing.","path":"/ideCAD/reinforcement-detailing-1","children":[]}]}]},{"id":"ci_a803f6c33d332d18dcc6368e493d1af733c349e9292a7a6f7d51466c530b383b","title":"Concrete Foundation Design.","path":"/ideCAD/concrete-foundation-design-1","children":[{"id":"ci_2c0a87c15920aa92251aa7cc7d9af367eb128c4a0702e7b457cd89ae25fa4ad2","title":"Shallow Foundation.","path":"/ideCAD/shallow-foundation-1","children":[]},{"id":"ci_d4f842f43e543767b09a3ad41c05d2ebc9483f1f76cf4021a6d39a182713efed","title":"Deep Foundation.","path":"/ideCAD/deep-foundation-1","children":[]},{"id":"ci_e5c858bd557092db460ae3a3e602e0a7a26230da4129b8e9a640e2a05428695c","title":"Foundations of Earthquake-Resistant Structures.","path":"/ideCAD/foundations-of-earthquake-resistant-structures-1","children":[]}]}]},{"id":"ci_ea799b3987950bd15462cebcfbf6b6d6a568388579df6997c14ea57bcf6f1d13","title":"Steel Element Design","path":"/ideCAD/steel-element-design","children":[{"id":"ci_9d6878812199f341de96ec11d0019154fbc3844fe0672ea437ee0b03042bb06c","title":"Steel Design Requirements","path":"/ideCAD/steel-design-requirements","children":[{"id":"ci_904f2519ee604ebd14de82ea24d17b0b2b209b0770324dc0ca05f692d8290d67","title":"Regulations Used","path":"/ideCAD/regulations-used","children":[{"id":"ci_fb7ceb03768844a8ec8de15073db2635a9ebe4871adc1cf244d31959abaef098","title":"ÇYTHYEDY 2018","path":"/ideCAD/cythyedy-2018","children":[{"id":"ci_15f3aafc35e5c8dda939dcd8bb66f01bbada40f1bc96e68f0f12f95557319e0f","title":"GKT","path":"/ideCAD/gkt","children":[]},{"id":"ci_1765ec2768ddcc345d727abb12d7ab6267e44a01bd87de5b24f761be2b0bb3f4","title":"YDKT","path":"/ideCAD/ydkt","children":[]}]},{"id":"ci_20ff204c180d5a455251a1f43b604e45e9ad47a064ca9383a75138f4107522ff","title":"AISC 360-16","path":"/ideCAD/aisc-360-16","children":[{"id":"ci_60ca4f3298b8091c9e5bd1b21ba86a4eff948e8283656ad9cc5a79bf63ad7f5e","title":"ASD","path":"/ideCAD/asd","children":[]},{"id":"ci_be0eedbe48c406339e3bb85ccf53086f635bb21feb8374464e095f85a58eb05d","title":"LRFD","path":"/ideCAD/lrfd","children":[]}]},{"id":"ci_4c9b98d68b52fab3dbcb5ab8b8a554ed1035edf3d363cea5f22a6514b3bff183","title":"Comparison of Regulations","path":"/ideCAD/comparison-of-regulations","children":[{"id":"ci_03eb1f5f044f45e8be44b8fb07378448ae646e221e5195a0b9d515f9b197cbee","title":"Comparison Sample Calculation","path":"/ideCAD/comparison-sample-calculation","children":[]}]}]}]},{"id":"ci_550a42bbb468a72f328a1e8080d83c85083671fe3f5188925fd772d852db53b2","title":"Steel Column Design","path":"/ideCAD/steel-column-design","children":[{"id":"ci_33d62f0cf0646f5bcd273cb4734701c2d0ee2dd058ee8d88d5b844df3c4a1ac8","title":"Column Design Settings","path":"/ideCAD/column-design-settings","children":[]},{"id":"ci_16d4dbb0c1d84229a9e3744c990098bb2c0178ffa940d3b673dac61c18807e9c","title":"Column Design","path":"/ideCAD/column-design","children":[{"id":"ci_2f28fca59dcf5456a9538071b04958cfe77ecbe92003197f583be7e2c7ab477b","title":"Flexural Buckling Design","path":"/ideCAD/flexural-buckling-design","children":[]},{"id":"ci_88ea74689dff3681c5e813cbd2277d9280595b24fbbcec43b14b259e17ef5aad","title":"Torsional Buckling Design","path":"/ideCAD/torsional-buckling-design","children":[]},{"id":"ci_34fc77a4805c27d25275834f13b5a95d67b6a466b41a42dd9d32138f28de60a3","title":"Flexural Torsional Buckling Design","path":"/ideCAD/flexural-torsional-buckling-design","children":[]},{"id":"ci_19fc0f5648bd08bf62266bf680583c5533777ac0461c76a8bcf454dbee3a639f","title":"Design of Steel Members for Combined Forces","path":"/ideCAD/design-of-steel-members-for-combined-forces","children":[]},{"id":"ci_217a761dbdc539227422483bc1e5d663585aa6b6598e7e9fb7be3ec78f295312","title":"Column Design Example","path":"/ideCAD/column-design-example","children":[]}]}]},{"id":"ci_903a390e0dff8560843918c8fc5e3cedf855aac488d6cb0f920a0c4b5616eb15","title":"Beam Design","path":"/ideCAD/beam-design","children":[{"id":"ci_480e89fb0701f919565943796ab4831883d304479d8d7e13ca3e97d70d0f3340","title":"Beam Design Settings","path":"/ideCAD/beam-design-settings","children":[]},{"id":"ci_0db68996e90961f931707b661febcbd7c9710bab286948b560d3df60a0eaafb7","title":"Steel Beam Design","path":"/ideCAD/steel-beam-design","children":[]},{"id":"ci_97d81708b34a00ad13cc2f3320deb3ee370d5d21a1da2e074dd39e1d2a8a170b","title":"Composite Beam Design","path":"/ideCAD/composite-beam-design","children":[{"id":"ci_a9d9db6a66e7d3cf702091c2b36bdf2b6227425c9c4ff233d38c8981c767f9bf","title":"Composite Beam Design Sample Calculation","path":"/ideCAD/composite-beam-design-sample-calculation","children":[]}]},{"id":"ci_70a9896bde5aecd7f2512502d273164fe4c4fb1f5c570dd03015bc3ce93b4ace","title":"Castellated Beam Design","path":"/ideCAD/castellated-beam-design","children":[{"id":"ci_49059ad9e2b821d7edd28380e6840106935a69191e981013fd1a6476150e13e9","title":"Castellated Beam Design Sample Calculation","path":"/ideCAD/castellated-beam-design-sample-calculation","children":[]}]},{"id":"ci_f63e6623b6155f88b101d2a692b000dc2233bc58c5e3e9edce76fc7784094cd9","title":"Composite Castellated Beam Design","path":"/ideCAD/composite-castellated-beam-design","children":[]},{"id":"ci_5b5b77a46e28f1551476ddc4a20762ebfd9f05a74dce40e21e20cb892badc636","title":"Crane Beam Design","path":"/ideCAD/crane-beam-design","children":[{"id":"ci_1d161293f70263757e35add44ac14fa8211ed2ab72963d7d969d425ebdcd3ceb","title":"Crane Beam Design Sample Calculation","path":"/ideCAD/crane-beam-design-sample-calculation","children":[]}]}]},{"id":"ci_90eab93b6c81baa9ffe7d2ddb4be15be6170eb7444e6cc33f4d28b845c1216be","title":"Secondary Beam Design","path":"/ideCAD/secondary-beam-design","children":[{"id":"ci_d503e4d88a08429d9440b0d0164e246f739afb672703838857c0e010db7d7e88","title":"Secondary Beam Design Settings","path":"/ideCAD/secondary-beam-design-settings","children":[]}]},{"id":"ci_33da9d557afcfbe1e081924ff27c7fde4a33b8b4f40046973cdca68d7aedf4dd","title":"Purlin Design","path":"/ideCAD/purlin-design","children":[{"id":"ci_dbebfdca0bef9bd132ea0cd24bea4a6c8a61e5e02996bdf18197b78a1339b631","title":"Purlin Design Settings","path":"/ideCAD/purlin-design-settings","children":[]}]},{"id":"ci_89e48e9427f976228317ca4ce9d1af963cc99ee5ea1bba1447e181fe0becee9c","title":"Concentrically Braced Design","path":"/ideCAD/concentrically-braced-design","children":[{"id":"ci_a93db7502dc1de07511400b665fde52baaa50938825af27b443f7560022a72c6","title":"Brace Design","path":"/ideCAD/brace-design","children":[]},{"id":"ci_7a6cd0a52ac78e7dad1f82c589f2ca17b643903a491df5aa30668a0a953d4c37","title":"Design for Tensile Force","path":"/ideCAD/design-for-tensile-force","children":[]},{"id":"ci_b0d0a486bb457161f8684b1e796620598ce19ac9343eef95a269747d1410f492","title":"Design for Compressive Force","path":"/ideCAD/design-for-compressive-force","children":[]}]},{"id":"ci_1221412cb03482a97c6c1d512d9bb877cee90ecb265e0c53d4cf4c2858c9ac84","title":"Truss Design","path":"/ideCAD/truss-design","children":[{"id":"ci_dd9d7c486f24d9e44a676280e3fa9a8f9eef4564ce1253bea1e53556e9d2c854","title":"Design of Truss Members for Tensile Forces","path":"/ideCAD/design-of-truss-members-for-tensile-forces","children":[]},{"id":"ci_2936447621fba25e0fc2fcbbbb99f36ac4efb72de0f83522f22eed326b6305ae","title":"Design of Truss Members for Compressive Forces","path":"/ideCAD/design-of-truss-members-for-compressive-forces","children":[]}]}]},{"id":"ci_e74e7d38a60e71229f150e1a3daac0dd05b479bf726081bf409c7df7a16d8008","title":"Steel Connection Design","path":"/ideCAD/steel-connection-design","children":[{"id":"ci_11b6e16f3ed4933513a51cf6e29ae5c46e2d5f9732df86b232cfcc3481f37dff","title":"Geometry Control for Connection Design","path":"/ideCAD/geometry-control-for-connection-design","children":[]},{"id":"ci_b7e0f1a6b045a37b2f3ebde69391e7c22525370f1f2c716f65f6beed40f155b1","title":"Shear Connection Design","path":"/ideCAD/shear-connection-design","children":[{"id":"ci_930f15f820c1b1ed93fa6a3e9faf99b7b06073e1decf341aae3aec0efc4990ee","title":"Single Plate Connection","path":"/ideCAD/single-plate-connection","children":[{"id":"ci_52b4d0005343a925c98f45838d9fafcb71d4e5186cfc8006656fee032f31299e","title":"Single Plate Connection Report","path":"/ideCAD/single-plate-connection-report","children":[]}]},{"id":"ci_0ebe64479a1fcba2a4828b025280e3413b0a08d89bdc0e242d6ca9d44cab5f6b","title":"Single Angle Connection","path":"/ideCAD/single-angle-connection","children":[{"id":"ci_8553222fbe611f2002ac0e02c10b7dde70ea5182a701e3bf4d85e3c3dcfda427","title":"Single Angle Connection Report","path":"/ideCAD/single-angle-connection-report","children":[]}]},{"id":"ci_b69963650bf9bb4822f177dafcb6ab4c12f26d10c5a347c73df8fac8bb557aec","title":"Double Angle Connection","path":"/ideCAD/double-angle-connection","children":[{"id":"ci_43aaa12947084c2e90f35375f7e2abfe26bbbfa071e499394ac435675de91a52","title":"Double Angle Connection Design Report","path":"/ideCAD/double-angle-connection-design-report","children":[]}]},{"id":"ci_59f0d51690f988e83823299bbf50d951963724e899d0fa5973ad9054883356fd","title":"T Plate Connection","path":"/ideCAD/t-plate-connection","children":[{"id":"ci_e761d122c7ec0bf38f54f10c3c602204d175d418abfe412acd307d2840f60da7","title":"T Profile Connection Design Report","path":"/ideCAD/t-profile-connection-design-report","children":[]}]},{"id":"ci_992402fd5eea4619d54a97020210553b3d0d71fc82fe34f91409ce95f03f435f","title":"End Plate Shear Connection","path":"/ideCAD/end-plate-shear-connection","children":[{"id":"ci_070618e0993e622fd1d08b81eb76bfb886eb1cc6671fdea097f5a9ea049ae5d1","title":"End Plate Shear Connetion Report","path":"/ideCAD/end-plate-shear-connetion-report","children":[]}]},{"id":"ci_f16054fa303bef0044c63e88baabe8f147c92c44fed5b778da5a71755a220eb4","title":"Unstiffened Seated Connection","path":"/ideCAD/unstiffened-seated-connection","children":[{"id":"ci_4435481131238b3ab896102de3d3f54b9022166d00af12246db0a0c69acfb75d","title":"Unstiffened Seated Connection Report","path":"/ideCAD/unstiffened-seated-connection-report","children":[]}]}]},{"id":"ci_b16249162da94bf2dba12ad467ad1a26dae8bb28d27a673191e963ba2c9af31f","title":"Moment Connection Design","path":"/ideCAD/moment-connection-design","children":[{"id":"ci_87879494bac5e7e03f4303be34a9b0dd1f0ba1da29aae1c480563c83d6c99392","title":"End Plate Connections","path":"/ideCAD/end-plate-connections","children":[{"id":"ci_ef2950dd38b037f53080185264486873e925084ede3afb7c06440fb7f993eb3d","title":"4 Bolt Unstiffened End Plate Connection Design","path":"/ideCAD/4-bolt-unstiffened-end-plate-connection-design","children":[{"id":"ci_13677d7ae08d5caf30512733e9a200f591642b1b17b96e2693110990a853599e","title":"4 Bolts Unstiffened End Plate Connection.","path":"/ideCAD/4-bolts-unstiffened-end-plate-connection","children":[]},{"id":"ci_752bf1a9869a124e7a4948141cccc46b332c1a71779b1f4eb68b6d87f4c46e06","title":"4 Bolt Unstiffened End Plate Connection Report 1","path":"/ideCAD/4-bolt-unstiffened-end-plate-connection-report-1","children":[]},{"id":"ci_0b0a52aed04e61fe3ee17d06aa3569624e1db0d28c35157a4d521eee380daca2","title":"4 Bolt Unstifened End Plate Connection Report 2","path":"/ideCAD/4-bolt-unstifened-end-plate-connection-report-2","children":[]}]},{"id":"ci_5ac852c010ee0b64beaf195d4337208d1f32a6c284d1cd00fff0148f6258c83a","title":"4 Bolts Stiffened End Plate Connection Design","path":"/ideCAD/4-bolts-stiffened-end-plate-connection-design","children":[{"id":"ci_337a3495bc9fa2459b12edac063e4d5ab891792e8d802dba51e130402b1315dd","title":"4 Bolt Stiffened End Plate Connection","path":"/ideCAD/4-bolt-stiffened-end-plate-connection","children":[]},{"id":"ci_dc68d0a0d2ebe1d04921e2ad0c8d1c25ee21c586c30b452280f9ff05ec9f346f","title":"4 Bolts Stiffened End Plate Connection Report","path":"/ideCAD/4-bolts-stiffened-end-plate-connection-report","children":[]}]},{"id":"ci_2f925cfc4da50a296e607fc687fcc1b89d47d75236106048f2c7845075fc7192","title":"8 Bolts Stiffened End Plate Connection Design","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-design","children":[{"id":"ci_afcfaa0bd24f03c561c747c53e937d5620081b28c828ad389450ee0da0c8862f","title":"8 Bolts Stiffened End Plate Connection","path":"/ideCAD/8-bolts-stiffened-end-plate-connection","children":[]},{"id":"ci_8ed97aab197d6c64e97ce59813f87c2c43189bb29539a08c803491f893acb660","title":"8 Bolts Stiffened End Plate Connection Report 1","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-report-1","children":[]},{"id":"ci_651db47c5cfbfe8627c47bd8d8d1dff4bd48a17e99426fcbe34ba16528b7b5bd","title":"8 Bolts Stiffened End Plate Connection Report 2","path":"/ideCAD/8-bolts-stiffened-end-plate-connection-report-2","children":[]}]}]},{"id":"ci_de5a9f6b3b39963ceaf73224e222e2d6b97b7748a46f1b5345c595b333766d5d","title":"Bolted Flange Plate Connection Design","path":"/ideCAD/bolted-flange-plate-connection-design","children":[{"id":"ci_7b128ac24f00f8e29833b240517c8e3f2dcaf30919b81a903caa62ed6dfc5114","title":"Bolted Flange Plate Connection","path":"/ideCAD/bolted-flange-plate-connection","children":[]},{"id":"ci_d1b40815664166e594f8aee9d5dac86c641a6f1aeb6f230f9d4fe39133db5728","title":"Bolted Flange Plate Connection Report 1","path":"/ideCAD/bolted-flange-plate-connection-report-1","children":[]},{"id":"ci_a817d611c835a571eb6f6f8eef1f7b5af7c59258093db91bf6a822f9a7d452cf","title":"Bolted Flange Plate Connection Report 2","path":"/ideCAD/bolted-flange-plate-connection-report-2","children":[]}]},{"id":"ci_8caaff6216aa05ae64198c335ba5ca5540837de7f191985aa9514865a9724bf6","title":"Welded Flange Plate Connection Design","path":"/ideCAD/welded-flange-plate-connection-design","children":[{"id":"ci_66e4b93c72b0c6b7a81b55e760007706234dd222a119c6a7951a3acea702b6e3","title":"Welded Flange Plate Connection","path":"/ideCAD/welded-flange-plate-connection","children":[]},{"id":"ci_c5cb37c7f391645b826e2da850f3f7e8b7ce0bfba08eee5514d4d041d65afc23","title":"Welded Flange Plate Connection Report","path":"/ideCAD/welded-flange-plate-connection-report","children":[]}]},{"id":"ci_f0bf16430d8fdad9c7d9dfe68aa11dc2e02d344cb32bec470e3191b82093962b","title":"Welded Web Connection Design","path":"/ideCAD/welded-web-connection-design","children":[{"id":"ci_7d8b86ec5fc2f561802fe85bf78de2337d8fdca9c40f122c0122050941fc91c5","title":"Welded Web Connection","path":"/ideCAD/welded-web-connection","children":[]},{"id":"ci_e3a4f44775b735f92e82c8ee37657c9e25d87b05f2957d34f801932e3e76f34b","title":"Welded Web Connection Report 1","path":"/ideCAD/welded-web-connection-report-1","children":[]},{"id":"ci_80734496c55aafd18449edb41ef2657d1cd23f07a7a0cdf9aeee5ca66ae3fa1b","title":"Welded Web Connection Report 2","path":"/ideCAD/welded-web-connection-report-2","children":[]}]},{"id":"ci_4254786a1cff67073b49a6d511464349a548459670b04900faeb64e05b78129f","title":"Joining Plates Connection","path":"/ideCAD/joining-plates-connection","children":[{"id":"ci_49abfe659764163878e6285da80f19d365835c927b6ff07621f2d5dea314fd32","title":"Joining Plates Connection Report","path":"/ideCAD/joining-plates-connection-report","children":[]}]},{"id":"ci_d7e0babb770f51a9763d7851b3a907b5bc813526c1267218841900081a7883b1","title":"Splice Connection Design","path":"/ideCAD/splice-connection-design","children":[{"id":"ci_e5e3834d5595ef47ede834d9e7509d24c088bdf928259cfe1151fea2a2f03808","title":"Splice Connection","path":"/ideCAD/splice-connection","children":[]},{"id":"ci_0fd2adcb2d4775796874b0180a891b7cb2c9a43ad254cc18296ffe8a5c1911c5","title":"Splice Connection Report 1","path":"/ideCAD/splice-connection-report-1","children":[]},{"id":"ci_a9549b4fe53e4363067251cb619aec29488fedea5ef1e4942dcaf237bbaa33d7","title":"Splice Connection Report 2","path":"/ideCAD/splice-connection-report-2","children":[]}]}]},{"id":"ci_3c12f36ae49890917d208538e136cd4fe8cd4c04d34251c498f8174de44805ca","title":"Brace Connection","path":"/ideCAD/brace-connection","children":[{"id":"ci_6886c283fe55cb60d58481e33f80d974b259a1f48edc7c21bca5bc0a23aa9c33","title":"Brace Corner Connection Design","path":"/ideCAD/brace-corner-connection-design","children":[{"id":"ci_fc54c2f8e3b48e6795891be31e9bb8afa6f71f3c342cb1e1113153b94228d9fa","title":"Brace Corner Connection","path":"/ideCAD/brace-corner-connection","children":[]},{"id":"ci_b81329ff812fc61900fae036339b883cf15915bfe19919a02482d0d392a442c5","title":"Brace Corner Connection Report","path":"/ideCAD/brace-corner-connection-report","children":[]}]},{"id":"ci_9ec2cc87ac50e5182210862aa861f78bea84765b3a6ac0a86f10002331249ce0","title":"Brace Center Connection Design","path":"/ideCAD/brace-center-connection-design","children":[{"id":"ci_debf156338342bd506779b66a68334042abc2e54e77829f9a8c95c8e432c9275","title":"Brace Center Connection","path":"/ideCAD/brace-center-connection","children":[]},{"id":"ci_01755dca7590291fc5bb8115726bfefede5f831a8a49a1d7398b98000d929a1e","title":"Brace Center Connection Report","path":"/ideCAD/brace-center-connection-report","children":[]}]}]},{"id":"ci_41557441563c974c864b55e7ba26616b6ffdbcf54087a741731dc9a12eb4645d","title":"Column - Foundation Connection (Stiffened Base Plate) Design","path":"/ideCAD/column-foundation-connection-stiffened-base-plat-1","children":[{"id":"ci_f0e01d0f10b38256eebb8f8d8a83ba9a4874e1e2daae5de009680ea3094cd8cc","title":"Column - Foundation Connection (Stiffened Base Plate)","path":"/ideCAD/column-foundation-connection-stiffened-base-plate","children":[]},{"id":"ci_aa137dce4ede36b8a8cc514e418b8e6d81c6495ee4535500a556bb9d3ccba589","title":"Column - Foundation Connection (Stiffened Base Plate) Report","path":"/ideCAD/column-foundation-connection-stiffened-base-plate-","children":[]}]}]},{"id":"ci_23ed2e6d8e77b3e2d25a587c1421fa8976dda1b04e61613b7d1cc7fc0b7b46cf","title":"Structural Inspection","path":"/ideCAD/structural-inspection","children":[{"id":"ci_dad92a8f24d3f19f2fc6a3d3e5b4cd26a7840981d147413ed70d8a907f479507","title":"View of the Analysis Model","path":"/ideCAD/view-of-the-analysis-model","children":[]},{"id":"ci_bc965b1e55cc2c39605ee904d2f5ba88cdf280f53fef979118b6111ee2a8d31d","title":"Deformations","path":"/ideCAD/deformations","children":[]},{"id":"ci_bcdea52f680dbac104fcf0726697878fcd1dd5399de754edee89d7b08445b37a","title":"Loads","path":"/ideCAD/loads","children":[]},{"id":"ci_ea7bec45bb76b93425cf7b6c1d5fc474747e3c86641f07589a9673408626ecd0","title":"Frame Results of Elements","path":"/ideCAD/frame-results-of-elements","children":[]},{"id":"ci_36db490d3cee3218326925ac76120eacba203b5f915593e0b438a1abc51c79c4","title":"Shearwalls Results (Internal Forces)","path":"/ideCAD/shearwalls-results-internal-forces","children":[]},{"id":"ci_dce9ddb9b8f59ec38d99a58cc34b84f7306a559443b2760f2f1e458eb4a21d90","title":"Frame Results of Purlin","path":"/ideCAD/frame-results-of-purlin","children":[]},{"id":"ci_04d22b32e89ff630ff47fe6614e07848d6ad5e7fc3ff2a9bde5fc25b5ad402b4","title":"Frame Results of Strip Foundation","path":"/ideCAD/frame-results-of-strip-foundation","children":[]},{"id":"ci_f23edb264254f42390eff49c1036d6e19b7119295a25a67955dff8ddb0c768fe","title":"Shell Results","path":"/ideCAD/shell-results","children":[]},{"id":"ci_785125f817a9113baf6163ab7a95d5cf98ba0314cd7923b404dbd8c8e9863fec","title":"Concrete Design Visualization","path":"/ideCAD/concrete-design-visualization","children":[{"id":"ci_e857098a31853ed598647c294a3d0e9fb8fd04c5070c053a0c7bbcad87e48481","title":"Concrete Design Input","path":"/ideCAD/concrete-design-input","children":[]},{"id":"ci_cc1c757949eebea272960c0d8c7cb6d3deaad1fcabcfd29c58c63a73f7770360","title":"Concrete Design Outputs","path":"/ideCAD/concrete-design-outputs","children":[]}]},{"id":"ci_3b502eaeb60793aad29cfb7d78ac7c157874b1cb0aef90593598027ab7679633","title":"Steel Design Visualization","path":"/ideCAD/steel-design-visualization","children":[{"id":"ci_1bbefafc4df72be69805050bfb4ab691bb8de992b8096a91ac88c9e953f87d5a","title":"Steel Design Inputs","path":"/ideCAD/steel-design-inputs","children":[]},{"id":"ci_676506226f4c7d91e6f5d6e822ed3ac7f1bd2b61f0dedda8e4481ddc9c388c73","title":"Steel Design Outputs","path":"/ideCAD/steel-design-outputs","children":[]}]},{"id":"ci_56c1ea8e29ee2136325a3ae618f7b1db2f6092e4dfdb7c0697c62f36e3d142a1","title":"Pushover Analysis Results","path":"/ideCAD/pushover-analysis-results","children":[]}]},{"id":"ci_de18f8f877a62b157e7d185013e8379c79c7081d74758f69cadf312d5e7d3101","title":"Performance Based Design","path":"/ideCAD/performance-based-design","children":[{"id":"ci_515324a722806385a6f0e19ab4e41deea9d2f368cdc96699622a791262304328","title":"Performance Levels","path":"/ideCAD/performance-levels","children":[{"id":"ci_819b35e5aa7918650d328fb554b0f74ed3c6cee646266a322c13f0014df63dea","title":"Performance Level Definition (5.1.3)","path":"/ideCAD/performance-level-definition-5-1-3","children":[]}]},{"id":"ci_7f6b231a66d9cd21c568b5d2d82bc96cb9f8ba0cf017ee5f554643ddb0d4602d","title":"Seismic Effect","path":"/ideCAD/seismic-effect","children":[{"id":"ci_a2d0e18849372c02f9eb8988aaac719540c7e95d2c348723acd5b8211df0e279","title":"Design Response Spectrum Definition (5.2.1)","path":"/ideCAD/design-response-spectrum-definition-5-2-1","children":[]}]},{"id":"ci_9100ed94db09baf65c7d47fb44d4a839df854ccba31a3dd259148b63fcabf512","title":"Basic Combinations with Seismic Load Effects","path":"/ideCAD/basic-combinations-with-seismic-load-effects","children":[{"id":"ci_174ff3c8cc04041f830e6001ee74c57ab48ed1962a45f8f40479797e4e2f4ae0","title":"Basic Combinations with Seismic Load Effects for Nonlinear Analysis","path":"/ideCAD/basic-combinations-with-seismic-load-effects-for-n","children":[]}]},{"id":"ci_0cf75429bfaddab7577ff71171a30b50cdd5e942a00c7bffa85b020751049226","title":"Concentrated Plasticity Model","path":"/ideCAD/concentrated-plasticity-model","children":[{"id":"ci_7ac982bbe72599b26f78702ff7f4448332af876a29075ca092136ee92af9ab93","title":"Plastic Hinge Model (5.3.1)","path":"/ideCAD/plastic-hinge-model-5-3-1","children":[]}]},{"id":"ci_c3b42b7691f96f22c48f47b7b7f02d4174b9fb18a142eabea8c574ad8f1d1a06","title":"Distributed Plasticity Models","path":"/ideCAD/distributed-plasticity-models","children":[{"id":"ci_43f8ffe918604a503601739ccac020297c95a9cfb5650a65d713043c1959d077","title":"Distributed Plasticity for Shear walls","path":"/ideCAD/distributed-plasticity-for-shear-walls","children":[]}]},{"id":"ci_6899577206150e3c6129459adb277fd7f905adf3b944eb28ad1bb404c94ff06d","title":"General Modeling","path":"/ideCAD/general-modeling","children":[{"id":"ci_bd8088ec794f09d787d97d3d72d0e3502282e65e689e203ec8cc55f99d79da46","title":"Modeling Rules for Nonlinear Analysis (5.4.1)","path":"/ideCAD/modeling-rules-for-nonlinear-analysis-5-4-1","children":[]}]},{"id":"ci_bafdabed2f19e0b41e8ad04c66191f100740004369dc7c830ea597e3929dd726","title":"Beams and Columns Modeling","path":"/ideCAD/beams-and-columns-modeling","children":[{"id":"ci_6bbb61ffae12320550345d9a07cb7c38f52765778a1e1754013c7b8b102e1f69","title":"Finite Frame  Elements (5.4.2.1)","path":"/ideCAD/finite-frame-elements-5-4-2-1","children":[]},{"id":"ci_8cb9630d7c2946e1d2b19776371eb804e1e548298bc758d7ad1ed84c104fd38e","title":"Node Degrees of Freedom (5.4.2.2)","path":"/ideCAD/node-degrees-of-freedom-5-4-2-2","children":[]},{"id":"ci_31ce176ffe15025c88ae3815a3cbaa65f3b8b8cf0cfb4ebbaa67b65e2199acd2","title":"Plastic Hinges at Columns and Beams (5.4.2.3)","path":"/ideCAD/plastic-hinges-at-columns-and-beams-5-4-2-3","children":[]},{"id":"ci_04a99f9b8ee3958aaf2ee5bca7b684627913cea2292f71b6c04811da7f6854b7","title":"Outside of the Potential Plastic Hinge Region (5.4.2.4)","path":"/ideCAD/outside-of-the-potential-plastic-hinge-region-5-4-","children":[]}]},{"id":"ci_5903c15e089e55fec8d03bab841e180a9ab727e8d05bb68c7d77fa0e50b458fa","title":"Nonlinear Modeling of Reinforced Concrete Shearwalls","path":"/ideCAD/nonlinear-modeling-of-reinforced-concrete-shearwal","children":[{"id":"ci_b55feaa96e62363e094689d47b83894f498b4e6ca2da4e7f995c72af354d4fbc","title":"Distributed Plasticity Modeling of Reinforced Concrete Shearwalls","path":"/ideCAD/distributed-plasticity-modeling-of-reinforced-conc","children":[]}]},{"id":"ci_92b6573efec84b19e04991e2673e005840b530ea5e44f4250e50faee37e85afb","title":"Basement Wall and Slab Modeling","path":"/ideCAD/basement-wall-and-slab-modeling","children":[{"id":"ci_b2a582211f335f3b7daa69aa8d777a84a0a1615d357719722580b4deea057626","title":"Effective Section Stiffness Definition According to Table 4.2 (5.4.4)","path":"/ideCAD/effective-section-stiffness-definition-according-t","children":[]}]},{"id":"ci_32ed0aec2677c267134942e058ac045225c8ea9060c9140977efb3e3909463da","title":"Effective Section Stiffness of Structural System Elements","path":"/ideCAD/effective-section-stiffness-of-structural-system-e","children":[{"id":"ci_14fa17c29afb4cc786f1d12b689547d0f3d6ca625b6c0926ff510298c99e1988","title":"Effective Section Stiffness of Linear Walls and Slabs (5.4.5.1)","path":"/ideCAD/effective-section-stiffness-of-linear-walls-and-sl","children":[]},{"id":"ci_dc9c9c6a7929f1726008c4444a69126e3382344aa2b048236b9c2d8a512092ac","title":"Effective Section Stiffness Definition for Outside of the Plastic Hinge Region (5.4.5.2)","path":"/ideCAD/effective-section-stiffness-definition-for-outside","children":[]}]},{"id":"ci_1a07c1b1df329a09c97f5ddf1b97991a451ce5c1fafaa0d71ffc5eb683925b4d","title":"Mass Modeling for Nonlinear Analysis","path":"/ideCAD/mass-modeling-for-nonlinear-analysis","children":[{"id":"ci_de905b18dda62b5ca274e4848d350941e8a5c5f5c372df98b3df855b52bad992","title":"Mass Definition at Joints (5.4.6)","path":"/ideCAD/mass-definition-at-joints-5-4-6","children":[]}]},{"id":"ci_29d4afbf16cd38da5fb9c5af5c9fed00c2b04ce5cfcea2d3968b85e568256de3","title":"Pushover Analysis Methods","path":"/ideCAD/pushover-analysis-methods","children":[{"id":"ci_6352b5073b18396847fa9ad0144679a7988151dee7419a3a06517fc513629294","title":"Basics of Pushover Analysis Methods","path":"/ideCAD/basics-of-pushover-analysis-methods","children":[]}]},{"id":"ci_bfdea1702ac5602334c1064ef3d942ef7b1f20b532b6710337d65d560ac80ba7","title":"Single Mode Pushover Analysis Methods","path":"/ideCAD/single-mode-pushover-analysis-methods","children":[{"id":"ci_e265eed475ac89f8f6be6c3926727486105953264a7f5005df551b8017597673","title":"Single Mode Pushover Analysis Methods' Conditions","path":"/ideCAD/single-mode-pushover-analysis-methods-conditions","children":[]}]},{"id":"ci_05a47b83c14d54750f16491262305ee5b5d3e9208c013c1e06a23260e055bb6a","title":"Constant Single Mode Pushover Analysis Method","path":"/ideCAD/constant-single-mode-pushover-analysis-method","children":[{"id":"ci_3923184a0e6113c92e7e237bd4cd1db2efe3d9e9877c4debc9d1d0fa465fe425","title":"Modal Characteristics and Lateral Load İncrement Determination (5B.1.1)","path":"/ideCAD/modal-characteristics-and-lateral-load-increment-d","children":[]},{"id":"ci_3ea47a4065be92d3330f2a2a4da5e5ecdf24455ee78a04cc02575c7c579e4b72","title":"Determination of Modal Pseudo-Acceleration, Modal Displacement Increment (5B.1.2 , 5B.1.3)","path":"/ideCAD/determination-of-modal-pseudo-acceleration-modal-2","children":[]},{"id":"ci_d79195d6cfa45933ee5420eb3e2df2b73f44ebfb0de697c44b4a620994fc2334","title":"Pushover Curve and Modal Capacity Curve (5B.1.4 , 5B.1.5)","path":"/ideCAD/pushover-curve-and-modal-capacity-curve-5b-1-4-5b-","children":[]}]},{"id":"ci_cb66dbb8f89b1c606637b8604ffd109a36f4f590bf1471ce121e0c3e5375c705","title":"Adaptive Single Mode Pushover Analysis Method","path":"/ideCAD/adaptive-single-mode-pushover-analysis-method","children":[{"id":"ci_34cd505100ed92c3ca7afcecaffbb8e0ff2a37bfd0985848097fa2e299d36109","title":"Modal Characteristics and Lateral Load İncrement Determination (5B.2.1 , 5B.2.2)","path":"/ideCAD/modal-characteristics-and-lateral-load-increment-1","children":[]},{"id":"ci_9d8cbc09348a3b465b26213dcb054c34ea9ce4fabb2d408ab93b91dbb94b0474","title":"Determination of Modal Pseudo-Acceleration, Modal Displacement Increment (5B.2.3 , 5B.2.4)","path":"/ideCAD/determination-of-modal-pseudo-acceleration-modal-1","children":[]},{"id":"ci_1a597d57779cd8abc13dee57a93bb3ee4ee7b9cef5d0991839675fab5d424345","title":"Pushover Curve and Modal Capacity Curve (5B.2.5 , 5B.2.6)","path":"/ideCAD/pushover-curve-and-modal-capacity-curve-5b-2-5-5b-","children":[]}]},{"id":"ci_cd021e43c78da4929a95b9b4c286a528c2b78a3e861f6a802f26597d031d8e96","title":"Performance Point of Single-Mode Pushover Analysis Methods (5B.3.5 , 5B.3.6)","path":"/ideCAD/performance-point-of-single-mode-pushover-analysis","children":[{"id":"ci_bf233745f6ea13c99f33c6ebb3b9c045f60fb79df13e78f1b771f2848ce7b442","title":"Determination of Modal Displacement and Performance Point (5B.3)","path":"/ideCAD/determination-of-modal-displacement-and-performanc","children":[]}]},{"id":"ci_8fec3b046a8af959362f70efc934f490ac7d376d8418d7911ea6d235c1a77362","title":"Incremental Response Spectrum Analysis (IRSA Method)","path":"/ideCAD/incremental-response-spectrum-analysis-irsa-method","children":[{"id":"ci_22d5dcaec2f6566633551873481fb58852d139a641d599b7bf7653d4c4d915c6","title":"Condition to be Shown in Accordance with 5.6.6.1","path":"/ideCAD/condition-to-be-shown-in-accordance-with-5-6-6-1","children":[]},{"id":"ci_d385e5a7a74a989d7cddf8f792c469dc6261a92db2d1ff7ea7013cb78994e7ea","title":"Non-Statistical Combination Condition (5.6.6.2)","path":"/ideCAD/non-statistical-combination-condition-5-6-6-2","children":[]},{"id":"ci_419fce33dd9d08a4a4ee84d04d68605cbb5dd0fde39a5f0ead2db061af0f519d","title":"Second-Order Effects (P-δ and P-Δ)","path":"/ideCAD/second-order-effects-p-d-and-p-d","children":[]},{"id":"ci_eadf5589e23a25f34d15504e70052ebb701d2aad41f2879093f92f21c346e97b","title":"Modal Characteristics Determination","path":"/ideCAD/modal-characteristics-determination","children":[]},{"id":"ci_0a82adb876661081f4e30b6e0eb7e8c455900f860b02459e885e96e47b275e06","title":"Determination of the Performance Point for Each Vibration Mode and Direction","path":"/ideCAD/determination-of-the-performance-point-for-each-vi","children":[]},{"id":"ci_db20addd692c2c3f0dcacdf58d558727874a33273e7faf9d75eb663a2834f61a","title":"Determination of Modal Pseudo-Acceleration, Modal Displacement Increment and Constant Scale Factor","path":"/ideCAD/determination-of-modal-pseudo-acceleration-modal-d","children":[]},{"id":"ci_54f7ab3a7b9e9d31f424e41abbc2b70bde03be906071dcccd09db2de0985759c","title":"Determination of Displacements for Each Direction and Mode","path":"/ideCAD/determination-of-displacements-for-each-direction-","children":[]},{"id":"ci_d2b4fc3f622c961be438e5d55a8cc8ff9bf4b5875eea2f8b9e179757b3b8e55a","title":"Determination of Internal Forces for Each Direction and Mode","path":"/ideCAD/determination-of-internal-forces-for-each-directio","children":[]},{"id":"ci_0620441639ef4b9a5f5170229f54d48a2dd7272308aba36fe81429d9f3eede92","title":"Application of Complete Quadratic Combination (CQC) Rule","path":"/ideCAD/application-of-complete-quadratic-combination-cqc-","children":[]},{"id":"ci_e2848c2e414d28840f359e5d57f1d5ac5326a82b33ebbe2256b34541b324541e","title":"Determination of Yielded Hinges and Modified Stiffness Matrix","path":"/ideCAD/determination-of-yielded-hinges-and-modified-stiff","children":[]},{"id":"ci_e8fe73069735721eddcc1e4b45f89b21ab452d3a56f851c9d9cafb3829b45b0f","title":"Termination of the Pushover Analysis","path":"/ideCAD/termination-of-the-pushover-analysis","children":[]}]},{"id":"ci_7870d5b40196886e19ded77bd2ad63cbba8e1fd99ecee8c4c78ba88c65cc8af7","title":"Selection and Scaling of Earthquake Records","path":"/ideCAD/selection-and-scaling-of-earthquake-records","children":[{"id":"ci_77998c571da2107812dc586fbf45f0ffb6d5de11972823c3eda0e5ac14a49d8b","title":"Scaling of Acceleration Records in Time History (2.5.2)","path":"/ideCAD/scaling-of-acceleration-records-in-time-history-2-","children":[]}]},{"id":"ci_171de7bd154705714c9633931a935ca9347a776dd1aec4ea36010171b444f5d6","title":"Plastic Deformation and Internal Force Limits for New Buildings","path":"/ideCAD/plastic-deformation-and-internal-force-limits-for-","children":[{"id":"ci_99f3b74c5e578583a5927480801ac2ec992b1a0e93bd86c1fc705e1d6af47770","title":"Collapse Prevention Performance Level for Distributed Plasticity Model 5.8.1.1","path":"/ideCAD/collapse-prevention-performance-level-for-distribu","children":[]},{"id":"ci_1f8e1e88d83c5c3f6700e9cd79815585e3e7685d3449a5298bdc7066763fb936","title":"Collapse Prevention Performance Level for Concentrated Plasticity Model","path":"/ideCAD/collapse-prevention-performance-level-for-concentr","children":[]},{"id":"ci_f961b0ec4320dd09e30eafaaba4e3cb78b05ab0f1c7842589f53568b33088e83","title":"Life Safety Performance Level","path":"/ideCAD/life-safety-performance-level","children":[]},{"id":"ci_b58a99c057494f9e3d39fe7076ce1f58b85721c568de4012fa27e05c71bd22c8","title":"Immediate Occupancy Performance Level","path":"/ideCAD/immediate-occupancy-performance-level","children":[]},{"id":"ci_842983d8c516a03158a69ab610e1a8f58d52fd686825967eacc974553738a413","title":"Internal Force Conditions (5.8.1.5)","path":"/ideCAD/internal-force-conditions-5-8-1-5","children":[]}]},{"id":"ci_6faaf6fbc3c09b4e7eba03bc36fcd0f6d83d38ecd7b6d12d8e96ee9d265bb028","title":"Plastic Deformation and Internal Force Limits for Existing Building","path":"/ideCAD/plastic-deformation-and-internal-force-limits-fo-1","children":[{"id":"ci_1634bc25381ff018ead3074b726c08706069b57142a7dee1bc83345241567df7","title":"Performance Level Determination for Existing Buildings","path":"/ideCAD/performance-level-determination-for-existing-build","children":[]},{"id":"ci_8f5cf3473b402248f2150824c6200dc6ee73619fc3ea0eb36bb884a8f7669768","title":"Internal Force Limits for Existing Buildings (Ductility Conditions)","path":"/ideCAD/internal-force-limits-for-existing-buildings-ducti","children":[]}]},{"id":"ci_cee4b5d7220a6339d2635d946761b34d67e2d8ad89db85d136012940e75c1cb4","title":"Structural Performance Evaluation According to Nonlinear Analysis","path":"/ideCAD/structural-performance-evaluation-according-to-n-1","children":[{"id":"ci_7e5621b4205b83632bd65f87e6b15565992310246a8c166b7f6a8c1721a17c3b","title":"Structural Performance Evaluation According to Nonlinear Analysis (5.9)","path":"/ideCAD/structural-performance-evaluation-according-to-non","children":[]}]},{"id":"ci_075f702c87a5eb4f5a2a31aa308023a05302ac3d5f86c5520cbb546f61465d57","title":"Stress-Strain Curves for Concrete and Reinforcement Materials","path":"/ideCAD/stress-strain-curves-for-concrete-and-reinforcemen","children":[{"id":"ci_d72de1efc4695e8c0585fc0a9e7197b739d3449b12cf428b772d13511c639e84","title":"Confined and Unconfined Concrete Material Model","path":"/ideCAD/confined-and-unconfined-concrete-material-model","children":[]},{"id":"ci_744086e7f21d378da1695a3d258732e01e3ae9c2653f0530399db863661dcb81","title":"Reinforcement Material Model","path":"/ideCAD/reinforcement-material-model","children":[]}]},{"id":"ci_90fa0f50caef2a7fe3129928d6b73c3f5b1bb5a5ce32de8e12a4e93661f2871c","title":"Nonlinear Analysis Examples","path":"/ideCAD/nonlinear-analysis-examples","children":[{"id":"ci_5f67c0d8a2872dd2ebe4dbbc8e33471ed176c170c0667bc34278352fad82b5f7","title":"Nonlinear Analysis Example 1","path":"/ideCAD/nonlinear-analysis-example-1","children":[]},{"id":"ci_d9a5603e816fb1a2ee90a8a0d7837ff4b63d10176f7ed1b92ee504c0162f004d","title":"Nonlinear Analysis Example 2","path":"/ideCAD/nonlinear-analysis-example-2","children":[]}]}]},{"id":"ci_32241e648cef0c9b970ba4a14f11ef09c0fc4defa232e04573dfaf550bd4eda1","title":"Evaluation of Existing Buildings","path":"/ideCAD/evaluation-of-existing-buildings","children":[{"id":"ci_c7fdf563660d80b2278bdcb68af818e5ef7152a5e599dd900bdc44fe72dfa6a6","title":"Information Level and Current Material Strength","path":"/ideCAD/information-level-and-current-material-strength","children":[{"id":"ci_292e955e10ad407fe683039a8a460eb5e153d6bf22eba21982c4ecf9bdc1e9b9","title":"15.2.2 and 15.2.3","path":"/ideCAD/15-2-2-and-15-2-3","children":[]},{"id":"ci_feb67cab83b5b73991e90cdc941fe945548379f67932279ad5a393729029f105","title":"15.2.12","path":"/ideCAD/15-2-12","children":[]}]},{"id":"ci_c4e37b82addfdd2e99c98dbd4b3f864d70d63905cc4c3ea6ccaed8a6ee6b8683","title":"Limited Information Level in Reinforced Concrete Buildings","path":"/ideCAD/limited-information-level-in-reinforced-concrete-b","children":[{"id":"ci_d1ec786a9df2250be983955201b2bb91031ef31aa4fb09128acb0a9214772a8c","title":"15.2.4","path":"/ideCAD/15-2-4","children":[]}]},{"id":"ci_5ad610086a9011c4f6bbea7314c4a395f6690ec5220ec5cc4c72dd6ee3077a14","title":"Comprehensive Information Level in Reinforced Concrete Buildings","path":"/ideCAD/comprehensive-information-level-in-reinforced-conc","children":[{"id":"ci_562da6771091d907c5ca6d3fb250ef5dad7fdebbd0bcd6c1290130da936aa0ba","title":"15.2.5","path":"/ideCAD/15-2-5","children":[]}]},{"id":"ci_65e28aa460f54d531d6dc2187cd84159e41c82363eab07a11342edc4c6d45f55","title":"Damage Limits and Damage Zones in Structural Elements","path":"/ideCAD/damage-limits-and-damage-zones-in-structural-eleme","children":[{"id":"ci_073f66e5fd7f9c95830d74a7b12dd12edfeb3c4699473332bc29374a7557324d","title":"15.3.1","path":"/ideCAD/15-3-1","children":[]},{"id":"ci_f86cf548f517a505d0daf8859443455b17460ccc6d63be33cbb594daa0838278","title":"15.3.2","path":"/ideCAD/15-3-2","children":[]},{"id":"ci_4ad5960cf8437f134d35a76c0dd368272116e9ca7bcf6743b0dc996e640c0f29","title":"15.3.3","path":"/ideCAD/15-3-3","children":[]}]},{"id":"ci_86a7e794eb099a7bf28072e6703235c714b0c9a199358f979d8f627ebe6eb314","title":"General Principles and Conditions for Seismic Analysis","path":"/ideCAD/general-principles-and-conditions-for-seismic-anal","children":[{"id":"ci_8df82e0b548c5bcff75a063b69b909b2fbaf2b72a1c3682b4c7e2567442be164","title":"15.4.1","path":"/ideCAD/15-4-1","children":[]},{"id":"ci_6b9a6e30afa4f41906fb47009be8393f4f481f56b60de7a2cd14095a0e5e6178","title":"15.4.2","path":"/ideCAD/15-4-2","children":[]},{"id":"ci_107326060beb84df848d8b0e1ab32e8c204096cd92d7b652f443d82bf2a16e6c","title":"15.4.3 - 15.4.4","path":"/ideCAD/15-4-3-4","children":[]},{"id":"ci_da3d31b68767485cf06579ea8fb2cab0c7a7e65c4f8c336b85484f3ed0fab0ab","title":"15.4.5","path":"/ideCAD/15-4-5","children":[]},{"id":"ci_06e80680e3ef8f2f560f4aae409e10b8f283e2b12fa6f572880cf22bc302cc26","title":"15.4.6","path":"/ideCAD/15-4-6","children":[]},{"id":"ci_0099b66b537e0e09d207317702b90709592013ed5dc6654b05ec81f3b786065a","title":"15.4.7","path":"/ideCAD/15-4-7","children":[]},{"id":"ci_31f6cd1695e4d140e24dc2c8cf38f6437045b084fc5273ab23f4d786648d37fa","title":"15.4.8","path":"/ideCAD/15-4-8","children":[]},{"id":"ci_e7b8740b44615ed7721395fdc8572755c36f5f2feba05aa91917b3f64243adfe","title":"15.4.9","path":"/ideCAD/15-4-9","children":[]},{"id":"ci_a185f0a9e269339882b06beaaf00ed5f4d7610b0c506a8177caca393afad7578","title":"15.4.10","path":"/ideCAD/15-4-10","children":[]},{"id":"ci_dafd8290ae600e0820e86dd4787058caf9699de20e96e2db5fcd02613cddfd09","title":"15.4.11","path":"/ideCAD/15-4-11","children":[]},{"id":"ci_a296f4a2e78d206c6c7db3ec98eb23c69be6ab4acb4f2be3eda5dbac663263f4","title":"15.4.13","path":"/ideCAD/15-4-13","children":[]},{"id":"ci_21b77a273155b655f358b06f66dd490b7d1427066ef1514843f03f518ba33a2e","title":"15.5.15","path":"/ideCAD/15-5-15","children":[]}]},{"id":"ci_14b6243c39a8e2baa1403c204a4bdfa8aab1678fb749073df5fbe015c1f07057","title":"Seismic Analysis with Linear Methods (Linear Performance Analysis)","path":"/ideCAD/seismic-analysis-with-linear-methods-linear-perfor","children":[{"id":"ci_eb93a496eb1eeb0e911990cbff9ebb6709d6927a381772fcb1281fa38b5c3016","title":"Linear Seismic Performance Analysis","path":"/ideCAD/linear-seismic-performance-analysis","children":[{"id":"ci_3bff58e365a8acd17743a8662ed803b4dcc431d3bada859b0e8cecc57b17400c","title":"15.5.1","path":"/ideCAD/15-5-1","children":[]}]},{"id":"ci_28458664970ab49760a8004119f4a949a134a76859f044ea3dcad2fe4cd3d540","title":"Determination of Damage Level in the Structural Elements of Concrete Buildings","path":"/ideCAD/determination-of-damage-level-in-the-structural-el","children":[{"id":"ci_3f195267128d0ae2edba01454c70be4c82c528af73d670ccc9468b9551947ac5","title":"15.5.2.1","path":"/ideCAD/15-5-2-1","children":[]},{"id":"ci_ccfb899ab343d1eb3633867348ec61dd9ca46f963e95ddd998ff3732e77fff95","title":"15.5.2.2","path":"/ideCAD/15-5-2-2","children":[]},{"id":"ci_fab662f7edc343d681f507f4bdae3bb4be50058097ad150ad513f940e53ccb1a","title":"15.5.2.3","path":"/ideCAD/15-5-2-3","children":[]},{"id":"ci_7f2733d5fd2377b3c3e10459a7b3112793a697b404831e6a2cf45c0da6568607","title":"15.5.2.5","path":"/ideCAD/15-5-2-5","children":[]}]},{"id":"ci_d5aa2b9c52da617829797d3624cabf3a69e2ba0b64bb43a0cbec4f7aa90d5a47","title":"Linear Performance Analysis Criteria","path":"/ideCAD/linear-performance-analysis-criteria","children":[{"id":"ci_26ac14341b150bb984ea1092c0fea13738f5dd8e50c145605a067623fafe6e02","title":"15.5.3.1","path":"/ideCAD/15-5-3-1","children":[]},{"id":"ci_d0a8877366a0f3e62991e7096e08b07dc10da9aeda0af2814222b95a2a4f5049","title":"15.5.3.2","path":"/ideCAD/15-5-3-2","children":[]},{"id":"ci_6ecbcd24886fc9747cd91860bf0329f2ef3e4caa71abedcb161f7a696fdca41a","title":"15.5.3.3","path":"/ideCAD/15-5-3-3","children":[]}]},{"id":"ci_5ff72179dc3802b4a5119f2837fad78bcd36c8899ade3735711e8ad4223e840e","title":"Deformation and Plastic Rotation Demand","path":"/ideCAD/deformation-and-plastic-rotation-demand","children":[{"id":"ci_a87de7c4bb124423070cc5f9aea27236d858b77fae5416eea55cbde711a438a8","title":"15.5.4.1","path":"/ideCAD/15-5-4-1","children":[]},{"id":"ci_f942b0010361ca371079938188477bb5768a398cfaddb46748b90cf6fbd8d5ca","title":"15.5.4.2","path":"/ideCAD/15-5-4-2","children":[]},{"id":"ci_5c0fe90ec3d91c4c0890b76ead844a425ca69e9a9e40f245873fb7a1cc08e48a","title":"15.5.4.3","path":"/ideCAD/15-5-4-3","children":[]},{"id":"ci_92b29bf3b1e99102d8064f0b52d5f365140fba0f965fc25182436408b363724d","title":"15.5.4.4","path":"/ideCAD/15-5-4-4","children":[]},{"id":"ci_7396c964055d4f34f4518d8b2c75e3de99a7a8c5deeb430a619e3c7cb13db91f","title":"15.5.4.5","path":"/ideCAD/15-5-4-5","children":[]}]},{"id":"ci_770cf801b911a176a86849a2e9d29ca642be93a3d91da8773b57a871ba9000aa","title":"Definition of Displaced Axis Rotations for Column, Shearwall and Beam Elements","path":"/ideCAD/definition-of-displaced-axis-rotations-for-column-","children":[{"id":"ci_5527dcf9bc9d6133aee4caf521c812825a775ca67b53f8f6c3463d718ebe8824","title":"15A.2","path":"/ideCAD/15a-2","children":[]},{"id":"ci_4d32f1ee595ad06613ab8c36ef8b9be5cf17882d92c70287e9d5b89980a11176","title":"15A.3","path":"/ideCAD/15a-3","children":[]},{"id":"ci_4c8e488bd1972ee487ecbb7fd97d7922afbab48bb7d1d0380b6da6773c2b9e2e","title":"15A.4","path":"/ideCAD/15a-4","children":[]}]}]},{"id":"ci_7b34427d7cc936afa00b1c82053ad8b3094ed483700dc34aef8d5adba886fa09","title":"Nonlinear Seismic Analysis Methods","path":"/ideCAD/nonlinear-seismic-analysis-methods","children":[{"id":"ci_43cc6c1041181b7c628a70b757d6d7959edb6a40ef4b99d7c029c72d04ec4239","title":"15.6.2","path":"/ideCAD/15-6-2","children":[]}]},{"id":"ci_f996b2a24485fc13f83303bac2d3903bac8a1d7b4fb9c69c107a015d3f425eec","title":"Deformation Limits of Reinforced Concrete Elements","path":"/ideCAD/deformation-limits-of-reinforced-concrete-elements","children":[{"id":"ci_fd0ef72619a2efa86295544e0b04a507ac17a324986cf5b9e3df34193abd70a8","title":"15.7.1.1","path":"/ideCAD/15-7-1-1","children":[]},{"id":"ci_fa8e1f49f52cc7f6d755ebc3210b16758eea76fe7c6654a3f191fe5b5ba342e2","title":"15.7.1.3","path":"/ideCAD/15-7-1-3","children":[]},{"id":"ci_47f0afe80cc63f862cd6d99045ae4f48050ed179d2f7dc9cbf0930ef76bc9139","title":"15.7.1.4","path":"/ideCAD/15-7-1-4","children":[]}]},{"id":"ci_24ea6cbc0e744e88a37dd6405602cf12785205c5d6fd1eab310578829fdfae6d","title":"Determination of Earthquake Performance of Existing Buildings","path":"/ideCAD/determination-of-earthquake-performance-of-existin","children":[{"id":"ci_d3f6f8c0fb2b48565d8ba5d0b7c894585ac63e9a44d928a5282b332dcdb17b2b","title":"15.8.1","path":"/ideCAD/15-8-1","children":[]},{"id":"ci_1b77e3407758076c29db5d41a8f452a705ec0c15659e990d7c5d9b650f9489fd","title":"15.8.2","path":"/ideCAD/15-8-2","children":[]},{"id":"ci_5ee8461912cc22e06f48c742cc7f581f6257fda88f3aae7ef8b3eeede314ca13","title":"15.8.3","path":"/ideCAD/15-8-3","children":[]},{"id":"ci_56b846c1378a719b2aad6f9005787c3a77e3a9726acb8804feec47457aeb0e7e","title":"15.8.4","path":"/ideCAD/15-8-4","children":[]},{"id":"ci_6b6454e7ff8ee0463a68deba557984712833b543d78d3aa3a4cbb3a8fc6a3d29","title":"15.8.5","path":"/ideCAD/15-8-5","children":[]},{"id":"ci_202b8a8f9569491079368212afc7b0c3bd7cce1bea6757fdfb7d9af5e23c8b83","title":"15.8.6","path":"/ideCAD/15-8-6","children":[]}]}]},{"id":"ci_2a1868593927306055c9cc9e414c6fd6a34319d2d4ddf7e5c62f2e17c8d7f4e8","title":"Structural Risk Analysis","path":"/ideCAD/structural-risk-analysis","children":[{"id":"ci_a6499f5cbb172c5aad7918558169130ba5011232c84c2323b314916ee342403c","title":"Structural Risk Analysis for Low-Rise Strcutures","path":"/ideCAD/structural-risk-analysis-for-low-rise-strcutures","children":[]},{"id":"ci_84145175bdbc4a1f5a8d46d4d19a524fc1912269720a920cd1bbf4422abac553","title":"Structure Risk Analysis","path":"/ideCAD/structure-risk-analysis","children":[]}]},{"id":"ci_aeab0af8e71d58e72cb4f683c0fda1e4934fe28807492273ca549be1c9d936e7","title":"Formwork Scaffolding","path":"/ideCAD/formwork-scaffolding","children":[{"id":"ci_2503d0dfa2397a587426e7a6a4a5a622475359d509e1f84b2a50dfd4c944c987","title":"Concrete Formwork Design","path":"/ideCAD/concrete-formwork-design","children":[]},{"id":"ci_7b180663aae596b56caf07883d2e60e535f98b3dd083c80bfb6c99f4a8d0f4bf","title":"Column Formwork Scaffolding Design Example","path":"/ideCAD/column-formwork-scaffolding-design-example","children":[]}]},{"id":"ci_142c159dc2a442c574b99d7b7929adc42c80cdc7ebfa7e90302fd9de7c343250","title":"Verification Examples","path":"/ideCAD/verification-examples","children":[{"id":"ci_c2b9372a79aaa9aeddce1f899af6c2580c29f2d7d706de8336c81b4075d9a88d","title":"SI Unit Examples","path":"/ideCAD/si-unit-examples","children":[{"id":"ci_e448d431c2cb7161672d637c974d9b5bbb5c464c6b78cf533366ec75cc78e823","title":"A Simply Supported Beam","path":"/ideCAD/a-simply-supported-beam","children":[]},{"id":"ci_f67b381c1189a1abed3cb9f27aa6c6260d1449ec0307bbcaff01e0763729d7bf","title":"2D Frame I","path":"/ideCAD/2d-frame-i","children":[]},{"id":"ci_cf4da56b0e074d5fa7f20e91a6a3d91a8225c01f29ccb2b7ebeed2a1703dd20a","title":"2D Frame II","path":"/ideCAD/2d-frame-ii","children":[]},{"id":"ci_fd4dc04032ff6d5fc292fc517272f31c4679edd5233437b6f0db2d11aa005bc2","title":"2D Frame III","path":"/ideCAD/2d-frame-iii","children":[]}]},{"id":"ci_29bb8eed86ba9cafe892ccf0e1a3ee9618d0060316cbd9b00438ab16e7759acf","title":"Isostatic 2D Frame","path":"/ideCAD/isostatic-2d-frame","children":[]},{"id":"ci_617bbc1eaa141a79f46c224ee542abed9fc99ee15a9228920a67b5b7e68deff5","title":"Temperature Loading","path":"/ideCAD/temperature-loading","children":[]},{"id":"ci_1bab028b4c4586c04972a5801037faf0f528daf88e2408932a78e6a80c887718","title":"Local Axis Angle Frame","path":"/ideCAD/local-axis-angle-frame","children":[]},{"id":"ci_6d5c3011e8226e3aa890f77abdd4d480e63ee6c1abe860d02ecd6c0b66a3ca1e","title":"Support Collapse Loading","path":"/ideCAD/support-collapse-loading","children":[]},{"id":"ci_62118c962e04f7682535067c8f129dc5656836e3d31ec964fc3f48019aeb1ea7","title":"Element Degrees of Freedoms","path":"/ideCAD/element-degrees-of-freedoms","children":[]},{"id":"ci_88f17ee1d44e7c2358ab234450a128a5ccfcdcdc7379c703b102666cdaf016ea","title":"Bending, Shear and Axial Deformations","path":"/ideCAD/bending-shear-and-axial-deformations","children":[]},{"id":"ci_b7591c3717add97e5660fff2717611b88a702feb0c092865dc621d163f132578","title":"2D Modal Response Spectrum Analysis Example","path":"/ideCAD/2d-modal-response-spectrum-analysis-example","children":[]},{"id":"ci_b80a3bc177ca26c70ba36f9ea1b20075e577efac9f50cc961f5d61703c466ca1","title":"Concrete Beam Reinforcement Design Example TS 500","path":"/ideCAD/concrete-Beam-Reinforcement-Design-Example","children":[]}]},{"id":"ci_f338096eba61484b2359d8d5c1247e043e92d894df33c2e32a52f0676afa9906","title":"Comparison Examples","path":"/ideCAD/comparison-examples","children":[{"id":"ci_8f4e8500aba283118798a14fe2d60df9f148eae1ae5b575128674bfa9e68cdb3","title":"Example 1","path":"/ideCAD/example-1","children":[]},{"id":"ci_1e0ee2d1f8383679ab39f06d8121f374bc5c7ae32fdd894fc8bfda09f7da435f","title":"Example 1 - Semi-Rigid Diaphragm Solution","path":"/ideCAD/example-1-semi-rigid-diaphragm-solution","children":[]}]},{"id":"ci_e9dfedac30815b9325739307fbc7dadeb878870474827ad027e1b24526fad6f7","title":"Earthquake Code Application Examples","path":"/ideCAD/earthquake-code-application-examples","children":[{"id":"ci_54810ea9bb2c26febd91f94c173173be20a40857f44a30d77b4380bd7f352b4a","title":"12-Storey Reinforced Concrete Shearwall / Flat Slab Building","path":"/ideCAD/12-storey-reinforced-concrete-shearwall-flat-slab-","children":[{"id":"ci_f0cc738a4450e9a651b6cf7dd4e73dd82ca9211fd706dc78b47b8a61528bebbc","title":"General Building Information","path":"/ideCAD/general-building-information","children":[{"id":"ci_42f0875827d93426b7bbad2b9fcde0b81be8b308fe33a42fe0c426f302daa4d9","title":"Building Geometry, Story and Coordinate Information","path":"/ideCAD/building-geometry-story-and-coordinate-information","children":[]},{"id":"ci_5aa678d5767dbebc73272f3175a83705fd06099ea0b7af9627344c8a8fdeafd1","title":"Material Information","path":"/ideCAD/material-information","children":[]},{"id":"ci_80916b31a4decaa0cad1d1b32d9c35dec54a9244677db94dc14429e9cfbc0dcc","title":"Vertical Static Loads","path":"/ideCAD/vertical-static-loads","children":[]},{"id":"ci_46b6f2b86481bfaa12a3451793fb1b2288c6632ebdf395f39d907d3c9e868117","title":"Soil Parameters","path":"/ideCAD/soil-parameters","children":[]},{"id":"ci_1e95d1ebe0530eb7f16d30764e7b08243698415ca73ae72330d150e419f89c63","title":"Horizontal Elastic Design Spectrum of the Building","path":"/ideCAD/horizontal-elastic-design-spectrum-of-the-building","children":[]},{"id":"ci_fe918e143c2ebc2193ec199199f1ca1e712c8ab33bfe83ad2b1f590cee2e04ae","title":"Vertical Elastic Design Spectrum of the Building","path":"/ideCAD/vertical-elastic-design-spectrum-of-the-building","children":[]}]},{"id":"ci_4f1c7bf73e596098bc95fdfc3cc6f2bdd6d55de55cc8b4c445257746d0f620fb","title":"Prelimanary dimensioning of Building Support System","path":"/ideCAD/prelimanary-dimensioning-of-building-support-syste","children":[{"id":"ci_0c0968166c73085cb6f7e6430cec5bfd0f743373c5de2ad3f92805cbc79bcf73","title":"Slab Pre-Dimensioning","path":"/ideCAD/slab-pre-dimensioning","children":[]},{"id":"ci_8a3c188ce121393dc0ebe1084015376c615bb09d88b2d00163317f89a5f98dfd","title":"Column Pre-Dimensioning","path":"/ideCAD/column-pre-dimensioning","children":[]},{"id":"ci_2d3af96cbc5f2baa08331a249d61a777ea240080f828e6d946be1f351dc9c705","title":"Shearwall Pre-Dimensioning","path":"/ideCAD/shearwall-pre-dimensioning","children":[]}]},{"id":"ci_d7be505214c976afd98c830b9db3b2eea89e9c715138ba0a00a94264db3fca4d","title":"Classifications for Seismic Code Applications.","path":"/ideCAD/classifications-for-seismic-code-applications","children":[{"id":"ci_46a7e118b253223e33de303b44d25abc03c98c8f58b5cf3fb0efc66090fc3f23","title":"Building Risk Category and Building Importance Factor","path":"/ideCAD/building-risk-category-and-building-importance-fac","children":[]},{"id":"ci_2de6a171610656411a7d4d5e8450bd02aceb09a7119180b8b5c7279f22ed44b0","title":"Seismic Design Category of the Building","path":"/ideCAD/seismic-design-category-of-the-building","children":[]},{"id":"ci_671255d9f825fe708e7f5f1cf1430916e02220090cc1cbc0d4937e020a8009ca","title":"Building Height and Building Height Class","path":"/ideCAD/building-height-and-building-height-class","children":[]},{"id":"ci_e351340fa59dc7e5744e7989674457276e2739b089ef0d9fa791369933adfbd1","title":"Building Performance Target of the Building","path":"/ideCAD/building-performance-target-of-the-building","children":[]},{"id":"ci_7a6860277a61d05d3bbe5a86faf610927b95b84be77f0265678c41493c1ee951","title":"Determining the Linear Calculation Method","path":"/ideCAD/determining-the-linear-calculation-method","children":[]},{"id":"ci_e5e8e229547e803da17cf9de6ad52d0bc13a5df8099f0afbda860a7eebdd7d93","title":"Determination of R and D Coefficients According to Carrier System Type","path":"/ideCAD/determination-of-r-and-d-coefficients-according-to","children":[]},{"id":"ci_187ecbeba76e54bf7ce1bf17a41fb75e6a0a3c6da1dcc9fab1194c6e969df8e0","title":"Shearwall Overturning Control","path":"/ideCAD/shearwall-overturning-control","children":[]},{"id":"ci_3c8393d740dea8ad8478f5f18dde2deb48b9a43465573714c326e54800378b74","title":"Reduced Design Acceleration Spectra for Building Related Aspects","path":"/ideCAD/reduced-design-acceleration-spectra-for-building-r","children":[]},{"id":"ci_5a0b16b272b7e5bfcc666805e77b227b1c4f80821da67752f46edbb18e182031","title":"Special Analysis Rules for TBDY 2018 Requirement for Flat Slab Systems","path":"/ideCAD/special-analysis-rules-for-tbdy-2018-requirement-f","children":[]},{"id":"ci_6cd934b8c0f5abd63937f34d3fec5c8c02046d8751d6e1ca5e54d0f221caa087","title":"Modeling the Structural System for Strength Based Design","path":"/ideCAD/modeling-the-structural-system-for-strength-based-","children":[]}]},{"id":"ci_cf99022815338b674b32889edc905e614b4b24f8ce71f03f446b74c3d469b14c","title":"Examination of Analysis Results","path":"/ideCAD/examination-of-analysis-results","children":[{"id":"ci_669db81234641c4ee384bbaf7991c3cbe9e15d08409d8124b048deb85014bf4c","title":"Special Analysis Rules in Basement Structures as per TBDY 2018","path":"/ideCAD/special-analysis-rules-in-basement-structures-as-p","children":[]},{"id":"ci_17a52a073367ae7021b4550400886a9ef72dda4463ef7a89ef7af9afbca90c94","title":"Modal Masses and Modal Analysis Results (First Stage)","path":"/ideCAD/modal-masses-and-modal-analysis-results-first-stag","children":[]},{"id":"ci_49d794fe91712751f4075dfbc974aaff12f9d9233ed556b7c01a9bdfe91bdb3a","title":"Sample Column Internal Force Results (First Stage)","path":"/ideCAD/sample-column-internal-force-results-first-stage","children":[]},{"id":"ci_4a71fd2b933fe976c6ed6c4983e0e4af22eab62a92436307b705d27a55d21576","title":"Sample Shearwall Internal Force Results (First Stage)","path":"/ideCAD/sample-shearwall-internal-force-results-first-stag","children":[]},{"id":"ci_3348bfd7dc70d23f3a93a0bbac72e5e338c5dcbd24ec8480feff29022b5eab31","title":"Modal Masses and Modal Analysis Results (Second Stage)","path":"/ideCAD/modal-masses-and-modal-analysis-results-second-sta","children":[]},{"id":"ci_08ad0a1ae2be74fbbf796774cd6212ee1c415b61109a88f3796f8e41e786ac39","title":"Sample Column Internal Force Results (Second Stage)","path":"/ideCAD/sample-column-internal-force-results-second-stage","children":[]},{"id":"ci_1f7a3c2a70d61ba73db423469e57c636bb95d28070ba1a169106560dd2a87cd9","title":"Sample Shearwall Internal Force Results (Second Stage)","path":"/ideCAD/sample-shearwall-internal-force-results-second-sta","children":[]}]},{"id":"ci_492a667c167a0a5cd52aeb4c7013298dd36f16ba1d5666c7fcf0fe535d78be64","title":"Determination of Internal Forces Essential for Design","path":"/ideCAD/determination-of-internal-forces-essential-for-des","children":[{"id":"ci_fbe5fbb6ee9aa2b6ee24d80c6202b1d1c5228b57bf299572aba3b9eb982c6a15","title":"Creating Loading Combinations","path":"/ideCAD/creating-loading-combinations","children":[]},{"id":"ci_54b37edacc322fb848f58dfe8665601f2758bec4251bf30e8433ccdfdb8214d1","title":"Increasing Reduced Internal Forces and Displacements According to Equivalent Base Shear Force","path":"/ideCAD/increasing-reduced-internal-forces-and-displacemen","children":[]},{"id":"ci_f15fa76c43f249002d1ca7c7c40b70d36e38cb050dd443559ead12d1e7c6f176","title":"Calculation and Control of Relative Story Displacements","path":"/ideCAD/calculation-and-control-of-relative-story-displace","children":[]},{"id":"ci_604df964223c5dcbdeb2df499837a35ce949949fe01b8031eed24d92f9ffe069","title":"Calculation and Control of the Second Order Effects","path":"/ideCAD/calculation-and-control-of-the-second-order-effect","children":[]},{"id":"ci_baae7511db005dda2ae606a48f9fa491e9c071e96d9ffdb0396a49ea69e70601","title":"Determination of Design Essential Internal Forces of Upper Section Elements in Basement Buildings","path":"/ideCAD/determination-of-design-essential-internal-forces-","children":[{"id":"ci_540f9fd623d8fc20c77e3b748bc56757381c90d0e3785e6473ba4ba3d3518249","title":"Design Essential Internal Forces for the Upper Section in Element Reports","path":"/ideCAD/design-essential-internal-forces-for-the-upper-sec","children":[]}]},{"id":"ci_df7e8545fdd7275bca002efeac5bb13dcc6f5162cda5f5a6c3a34a88162f4c82","title":"Determination of Design Basis Internal Forces of Basement Story Elements in Basement Buildings","path":"/ideCAD/determination-of-design-basis-internal-forces-of-b","children":[{"id":"ci_39d6fd12b5c539a2b27db76a992962af6d08903746865441e665c5b043474cf0","title":"Design Essential Internal Forces for Basement Story Elements in Element Reports","path":"/ideCAD/design-essential-internal-forces-for-basement-stor","children":[]}]},{"id":"ci_ad9fd150fc38fffa038a8276a51601e5924cc6a6bdb1d65d1f5e005b7a3e740e","title":"Sample Column Results","path":"/ideCAD/sample-column-results","children":[]},{"id":"ci_844ce30aca83c603d7c13f923365da1c4e741c2055838331dfaa4cea10d7ab26","title":"Sample Shearwall Results","path":"/ideCAD/sample-shearwall-results","children":[]},{"id":"ci_96a271ec00ddc19087ce0384033dbe05af5c2e097f80f799b0e35624b194d372","title":"Design Essential Internal Forces for the Foundation","path":"/ideCAD/design-essential-internal-forces-for-the-foundatio","children":[]}]},{"id":"ci_1a1f676cc9afdef3d8b85de7f41cc359ce73fe331ed252fd3b5187512bedd358","title":"Irregularity Controls","path":"/ideCAD/irregularity-controls","children":[{"id":"ci_87c30a93c1a9be7d849bdf8f16ca796f9eef8655cf34769e96c3a8614a53a1c7","title":"A1- Torsion Irregularity Control","path":"/ideCAD/a1-torsion-irregularity-control","children":[]},{"id":"ci_84d68bf20e425eb13590b66edc1fd4b986a79757800a01bce1881ecf44cbb18b","title":"Interstory Strength Irregularity (Weak Story)","path":"/ideCAD/interstory-strength-irregularity-weak-story","children":[]},{"id":"ci_3df8497f1fce627a9ef988f055bf072aa1633d487942c23854ebdc5f6fb077ac","title":"B2-Interstory Stiffness Irregularity (Soft Story)","path":"/ideCAD/b2-interstory-stiffness-irregularity-soft-story","children":[]}]},{"id":"ci_695d84b7e78f585a0f76a0dbc415a2c7a6a1e03239a7fbc02c1badc404c175ec","title":"Design Principles of Reinforced Concrete Elements","path":"/ideCAD/design-principles-of-reinforced-concrete-elements","children":[{"id":"ci_051eae7414871484bef044534e400bcf6526962d1eff43d657994d56475606f6","title":"Sample Coupling Beam Design","path":"/ideCAD/sample-coupling-beam-design","children":[]},{"id":"ci_2e6bfdfd9fdc84b5d04ebf7483ba1a9746daaff1ebcd7305f9d9b69855ded0ee","title":"Sample Column Design","path":"/ideCAD/sample-column-design","children":[]},{"id":"ci_bdb583190c0b1e62542a0bdd10c516f2c3ac9f7ec4576c086a1aa0583c0e1a76","title":"Sample Shearwall Design","path":"/ideCAD/sample-shearwall-design","children":[]},{"id":"ci_0d116700ca9b259fcb67ee7634ca63959e590a0be7f8bab23b1ba91074626121","title":"Sample Slab Design","path":"/ideCAD/sample-slab-design","children":[]},{"id":"ci_c5b07c2f8ee3db204cf8ec6ac1c7820c934e81d4b9fde1c329d1a2d16039af73","title":"Sample Foundation Design","path":"/ideCAD/sample-foundation-design","children":[]}]}]},{"id":"ci_b2579868b97cc9be00fb102c88aae2eb3c9e15f89bedc3d1fd0df5771ddbef1e","title":"Example of a Steel Moment-Transferring Frame","path":"/ideCAD/example-of-a-steel-moment-transferring-frame","children":[{"id":"ci_daa92321846ed6ff0ed509671c8d15ccb09ac72ce7d97f4b5326f5320c1a898d","title":"General Building Informations","path":"/ideCAD/general-building-informations","children":[{"id":"ci_93a6fb412a783d3dbc2957a7d002a7b4d2b09772fc1980a625bfa37e4b15fca7","title":"Building Geometry and Location","path":"/ideCAD/building-geometry-and-location","children":[]},{"id":"ci_3efcb9d7408a542213feb39267c38bed386b4085dcb8c99ea1e241468fe556f2","title":"Material","path":"/ideCAD/material","children":[]},{"id":"ci_9b5f76491ca4d2427f520631d57282793f4e0b4a542f078205d58f42bd34be61","title":"Vertical Loads","path":"/ideCAD/vertical-loads","children":[]},{"id":"ci_467c86da74db837d200c6efc9d86f2b0c0a8c35eb02766bef6e6f637307ed082","title":"Horizontal Elastic Design Spectrum.","path":"/ideCAD/horizontal-elastic-design-spectrum","children":[]},{"id":"ci_165577441abfcd4d575b79bb052f3e40b540d39093e1af57ea97023ae0f8a079","title":"The Vertical Elastic Design Spectrum of the Building.","path":"/ideCAD/the-vertical-elastic-design-spectrum-of-the-buildi","children":[]}]},{"id":"ci_3558a0746ac40e7f9ba88c9c69b5cb0dd84ec8e0173ada642400d65d800b7d3c","title":"Classifications for Seismic Code Applications","path":"/ideCAD/classifications-for-seismic-code-applications-1","children":[{"id":"ci_377f4941243a0f6d3bfb5d139f566134d73b9fe9635b4bf9de3edef363194854","title":"Building Risk Category and Importance Factor","path":"/ideCAD/building-risk-category-and-importance-factor","children":[]},{"id":"ci_d9b0132b1c77fa47105bdab37a3bea7f164b5ee42a6729f84393ec64e5cab844","title":"Seismic Design Category Selection","path":"/ideCAD/seismic-design-category-selection","children":[]},{"id":"ci_41b0c403d234fbf0df794ea4a06f48f8e5c62c42930d4827a8431b5bb800964b","title":"Building Height and Building Height Class.","path":"/ideCAD/building-height-and-building-height-class-1","children":[]},{"id":"ci_ea3e821972bc9978887cb5c957319f27e9c955b88a0b651cff11bce4c80c6d51","title":"Building Performance Target","path":"/ideCAD/building-performance-target","children":[]},{"id":"ci_f4d64071e643ba1f327ff94b88e1d9fdb1a631941cc64c8cc93cd1dcf609f2f8","title":"Determination of Linear Calculation Method for Building","path":"/ideCAD/determination-of-linear-calculation-method-for-bui","children":[]},{"id":"ci_4771807476aa15d9dc4c63e8c80e10880b5afa1a3bf0b1fc4c3530e403f1bde8","title":"Determination of R and D Coefficients According to the Type of Structural System","path":"/ideCAD/determination-of-r-and-d-coefficients-according--1","children":[]},{"id":"ci_136e6a604aa7fe372af7ee44f4252b74ce9ad09ea919e947bef056ab6a356b52","title":"Reduced Design Acceleration Spectra for Relevant Building Aspects","path":"/ideCAD/reduced-design-acceleration-spectra-for-relevant-b","children":[]},{"id":"ci_8190eed5fae5392dae757acd493aae390da24ab349188060badf142ed4d26ff3","title":"Modeling of Steel Structural System for Strength Based Design","path":"/ideCAD/modeling-of-steel-structural-system-for-strength-b","children":[]}]},{"id":"ci_70c4f2ca47c2870e0464c3ef2070da3ae7d77c96b363bf7a33ac393867fc16c0","title":"Determination of Internal Forces","path":"/ideCAD/determination-of-internal-forces","children":[{"id":"ci_f7081eeabda646fa6f330cccb7986f6b7ff59b6b85dabaf0bf5cc903f905172e","title":"Automatic Load Combinations","path":"/ideCAD/automatic-load-combinations","children":[]},{"id":"ci_9787e903a511fb75a2a6fb4e370d8ef67d95b98d153f9b26e4a4ac203a6fa465","title":"Magnification of Reduced Internal Forces and Displacements for Building to Equivalent Base Shear Force","path":"/ideCAD/magnification-of-reduced-internal-forces-and-displ","children":[]},{"id":"ci_083322a56992b87f2c8184f0b9518460ee0634832369d2bc85f43d22bf922be7","title":"Calculation and Control of Relative Story Displacements.","path":"/ideCAD/calculation-and-control-of-relative-story-displa-1","children":[]},{"id":"ci_d59622e63730b1320e1996e7d92e4beea6a6f927a98c88d1502a6d3d5c326c68","title":"Second Order Effect Calculation and Control","path":"/ideCAD/second-order-effect-calculation-and-control","children":[]},{"id":"ci_d0f836c00b3216350bfa8f20b801eed3d8d6d018c0638a353521cc66812f70dd","title":"Determination of Design-Based Internal Forces of Moment-Transferring Frame Elements in Steel Buildings","path":"/ideCAD/determination-of-design-based-internal-forces-of-m","children":[{"id":"ci_9ce056c399025a6c5145f94658c5e94a4609767b47aa5392683922229a1d87af","title":"Internal Forces Based on Design Given in the Reports of the Columns of Special Steel Moment Frames","path":"/ideCAD/internal-forces-based-on-design-given-in-the-repor","children":[]}]}]},{"id":"ci_6ddc99d76c593cd31bd5def8e790588765c0073f95f92411a53c094fd62b50d7","title":"Building Irregularity Checks","path":"/ideCAD/building-irregularity-checks","children":[{"id":"ci_b8bdb3db2dfe05d5b0b6d781d7a0fe99bb9877b95dad81c70400163a608b8845","title":"A1 - Building Torsional Irregularity Control","path":"/ideCAD/a1-building-torsional-irregularity-control","children":[]},{"id":"ci_adf8e6a8f625ded84894c36c939e011a6840f88ae8358e475bc6654773d0c26c","title":"B2-Control of Stiffness Irregularity Between Adjacent Floors in the Building","path":"/ideCAD/b2-control-of-stiffness-irregularity-between-adjac","children":[]}]},{"id":"ci_ef5101c84e42aff765fb1e690cd96808c3f09fd2b536f4a5fa15bbebd5653518","title":"Design Principles of Steel Elements","path":"/ideCAD/design-principles-of-steel-elements","children":[{"id":"ci_8c9b1173a024bb918eedb7b6ea7f4ab9a5af23f939125bf50d490f2ff6425166","title":"Steel Column Design Example","path":"/ideCAD/steel-column-design-example","children":[]},{"id":"ci_791d23ff49054e20cf8ed17e4bdb0d94b991f5adb256430a2edc0e3f373c19af","title":"Steel Secondary Beam Design Example","path":"/ideCAD/steel-secondary-beam-design-example","children":[]},{"id":"ci_245bbab4c2ce5a92eb36f731329d64adf0554f90f978f9e55b485eeb23f5c19f","title":"Steel Beam Design Example","path":"/ideCAD/steel-beam-design-example","children":[]},{"id":"ci_3cc85f7f0675506028f476e7956fed07e49ade58eee3282f0f2fb365b86752e7","title":"Strong Column - Weak Beam Control","path":"/ideCAD/strong-column-weak-beam-control","children":[]},{"id":"ci_f174980f58c05a5496b600cc4f0c6ee44bf6b74c4f4cdd0f54c6478380c592d4","title":"Design of 8 Bolts Stiffened End Plate Connection","path":"/ideCAD/design-of-8-bolts-stiffened-end-plate-connection","children":[]}]}]}]}]},{"id":"ci_f0726cf052308918a0dba9f6a08731d5a910b517bb824083168c85ffcb039424","title":"Error Solution Guide","path":"/ideCAD/error-solution-guide","children":[{"id":"ci_c046a98f932a9caf912cd7861b8a767458608095f85dc52b0312050974911cdf","title":"Application Limits and R Coefficient Controls","path":"/ideCAD/application-limits-and-r-coefficient-controls","children":[{"id":"ci_5a27b9c3eb312291b6b1b1cfcaa99fcaf736025214fac5e364bf5999dad0abe4","title":"Shearwall should be used for A12.","path":"/ideCAD/shearwall-should-be-used-for-a12","children":[]},{"id":"ci_9cf4db1aa154b33aedcc37ea21cf6e918b83820ca91691e44e05d65ecb92dc8d","title":"Shearwall should be used for A13.","path":"/ideCAD/shearwall-should-be-used-for-a13","children":[]},{"id":"ci_c0e81695b631395f42e32c5d2ba66d77256f61a3fa8b88e2948029b49f42d143","title":"Shearwall should be used for A14.","path":"/ideCAD/shearwall-should-be-used-for-a14","children":[]},{"id":"ci_09c9c2b39c3697529140ae7b05e1256450a50bc786eaf83add8ba94056980f77","title":"Shearwall should be used for A15.","path":"/ideCAD/shearwall-should-be-used-for-a15","children":[]},{"id":"ci_5c75b8abffcfd5f03f0f46b96f693fddc770f75d7777b8096c9274700283a217","title":"Shearwall should be used for A21.","path":"/ideCAD/shearwall-should-be-used-for-a21","children":[]},{"id":"ci_ba7d788ca556062d10bcb40e58b829ed4afa98b0b55d4858f02869f3718940e4","title":"Shearwall should be used for A22.","path":"/ideCAD/shearwall-should-be-used-for-a22","children":[]},{"id":"ci_768eb475880743cb7d759a8b59fb982f0fd24746b3145dfc22960af2078e36f6","title":"Shearwall should be used for A23.","path":"/ideCAD/shearwall-should-be-used-for-a23","children":[]},{"id":"ci_d8df49cf336c683d3e862fd159a03feba9e7b12bbf607187078e4ea7d736214e","title":"A24 is selected. Shearwalls should be used.","path":"/ideCAD/a24-is-selected-shearwalls-should-be-used","children":[]},{"id":"ci_d33a6ac327000f8229a4f6a9104918f1b95e13fabed2d7b69afd584e25eaebca","title":"There are shearwalls. A11 cannot be selected","path":"/ideCAD/there-are-shearwalls-a11-cannot-be-selected","children":[]},{"id":"ci_b88cac8cfda7786cc67cf33155c484704ee2d0bb7d23ac942737ba55c7c80221","title":"Shearwalls with coupling beam is not found for A12","path":"/ideCAD/there-are-no-coupling-beam-shearwall-for-the-a12","children":[]},{"id":"ci_a75bac2c253cb00e902a543b72632bcc717ed8b98191f8ebd98751d8c9b9002f","title":"Shearwalls with coupling beam is not found for A14","path":"/ideCAD/there-are-no-coupling-beam-shearwall-for-the-a14","children":[]},{"id":"ci_3f2f80d5efaa91c5c5dd036759b97707a3bb63d3158457a7759f3e4154ba7413","title":"A31 can be used in buildings with DTS = 3 or 4","path":"/ideCAD/a31-can-be-used-in-buildings-with-dts-3-or-4-1","children":[]},{"id":"ci_c50386a3a57b4f2bb4dae6bdf2405bd427c642b998970d5bf1c032c99726397a","title":"A31 can be used in buildings with DTS = 3 or 4.","path":"/ideCAD/a31-can-be-used-in-buildings-with-dts-3-or-4","children":[]},{"id":"ci_a5e8fed6f4f8f0360d0876f08080f43d0de15a0e78a2f809be6025e6b603fe85","title":"The condition ∑Mdev / M0> = 0.75 at mixed ductility level could not be met.","path":"/ideCAD/the-condition-mdev-m0-0-75-at-mixed-ductility-leve","children":[]},{"id":"ci_47b1bacefcc8e29f63b496146015421d368f4d1b78da079355a130f3a9f128ed","title":"For DTS = 3, Mdev / Mo> = 0.75 must be provided.","path":"/ideCAD/for-dts-3-mdev-mo-0-75-must-be-provided","children":[]},{"id":"ci_c824f49690ad748b6fbe08b498d7804961e4a63615d2c95b7a40e1ca19669942","title":"For DTS = 4, Mdev / Mo> = 0.75 must be provided.","path":"/ideCAD/for-dts-4-mdev-mo-0-75-must-be-provided","children":[]},{"id":"ci_a6bc233f2477734611f2b222a35a7779f7943895d67ba93a62f84ea4556ab47f","title":"For DTS = 1, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-1-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_12d34d604c490079d426188de7787d2897d58f56c574e0aea06acdc0040209c5","title":"For DTS = 1a, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-1a-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_61b69184782d711929203c966c7bb42dd541775265da35d7f17365bbc66e7bfc","title":"For DTS = 2, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-2-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_b903cb5437b7e720ed5346992a46da32bf6f379e9e99c87b4921afeaefd4768e","title":"For DTS = 2a, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-2a-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_343f9fcfeb476da50a0a0fb4e6f2ce3a6505e9656161207069f995800047d188","title":"For DTS = 3a, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-3a-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_0b48e025a292e562e4ac1a6a73709ce6291325bcfc7238b04b5ba4769c0ca6d1","title":"For DTS = 4a, Mdev> = 0.75Mo must be provided.","path":"/ideCAD/for-dts-4a-mdev-0-75mo-must-be-provided","children":[]},{"id":"ci_bbc09f0e11532d5c7109e30471486de491293f6536631bb5ce54cf5fca5b2344","title":"For A33 ∑Mdev / Mo> = 0.75.","path":"/ideCAD/for-a33-mdev-mo-0-75","children":[]},{"id":"ci_3ee152f464183285684ca33dd6f6d4ca5ef0cadf29ab6b8562bd0eaa318711dc","title":"For A32 ∑Mdev / Mo> = 0.75.","path":"/ideCAD/for-a32-mdev-mo-0-75","children":[]},{"id":"ci_51d575741fda5c14de4e52c46572d6636c2056c9b23f38b19c8eb8037fb25e56","title":"It cannot be used with high ductility level.","path":"/ideCAD/it-cannot-be-used-with-high-ductility-level","children":[]},{"id":"ci_38559cca6c511be4f19b69d1184b7a256115d2a6103c39e055eec94456a5b34c","title":"Systems with limited ductility level cannot be used for DTS 1a","path":"/ideCAD/systems-with-limited-ductility-level-cannot-be-u-1","children":[]},{"id":"ci_ff24395274bc6d87b8d881fafb7fd1cdc7419a76090efe223e1d8dccc42724fb","title":"Systems with limited ductility level cannot be used for DTS 2a","path":"/ideCAD/systems-with-limited-ductility-level-cannot-be-use","children":[]},{"id":"ci_9faf58d04aabac3d2be7fc3b06e839d713dab3cc3cc3a0820fc47c97a833babc","title":"Systems with limited ductility level cannot be used for DTS 3a","path":"/ideCAD/systems-with-limited-ductility-level-cannot-be-u-2","children":[]},{"id":"ci_939b4197bef6795bb82a7577982a9b63bf63e71736427044d07d83aa13997f7c","title":"Systems with limited ductility level cannot be used for DTS 4a","path":"/ideCAD/systems-with-limited-ductility-level-cannot-be-u-3","children":[]},{"id":"ci_8088df9d95a6947992e4881c7221e59e6d0f06771fa42b79ca15147b11a5ee0b","title":"Systems with limited ductility level cannot be used for DTS 1a, 2a, 3a, 4a","path":"/ideCAD/systems-with-limited-ductility-level-cannot-be-u-4","children":[]},{"id":"ci_02a8a55a5f33afb390e85c868d80da0d5a07fae57c1d3e4c8e11fc8673fefeb0","title":"For A11, (BYS)> = 3 condition is not met.","path":"/ideCAD/for-a11-bys-3-condition-is-not-met","children":[]},{"id":"ci_b9c0ceacab5b0e78bfe74fa8bb8d8070af3a671b7786ac455cd0b4f3f0ac5016","title":"For A12, (BYS)> = 2 condition is not met.","path":"/ideCAD/for-a12-bys-2-condition-is-not-met","children":[]},{"id":"ci_63a4e353437b3c69c173a2abaec6cd4b041f08bc4a59ae2240d4a6617e619050","title":"For A13, (BYS)> = 2 condition is not met","path":"/ideCAD/for-a13-bys-2-condition-is-not-met","children":[]},{"id":"ci_6ced8c539f34997a5e10b045885bcae45945a814f824e46f99ee48716962d90b","title":"For A14, the (BYS)> = 2 condition is not met.","path":"/ideCAD/for-a14-the-bys-2-condition-is-not-met","children":[]},{"id":"ci_70059102d69c98d02431d2a7d9697435e3f25c0d67d43b83ed6f7fa4a274f740","title":"For A15, the (BYS)> = 2 condition is not met.","path":"/ideCAD/for-a15-the-bys-2-condition-is-not-met","children":[]},{"id":"ci_b9627adc5b6eece2a74240912066dd16df02513f41c648d353cdfdc32490d08d","title":"For A21, (BYS)> = 4 condition is not met","path":"/ideCAD/for-a21-bys-4-condition-is-not-met","children":[]},{"id":"ci_9762ffc1a155122d4db4c965765e81d2f68831ca9939844b18d1988e58cc16c3","title":"For A22 (BYS)> = 4 condition is not met.","path":"/ideCAD/for-a22-bys-4-condition-is-not-met","children":[]},{"id":"ci_007479be88b46faa5f961b00bb075febccbc264d47029791e16eb6976d856a0b","title":"For A23, (BYS)> = 6 condition is not met.","path":"/ideCAD/for-a23-bys-6-condition-is-not-met","children":[]},{"id":"ci_7d1d3fad34e87d53cc313764edf00d63ab64723df7decabab353b80c5b85a0ea","title":"For A24, (BYS)> = 6 condition is not met.","path":"/ideCAD/for-a24-bys-6-condition-is-not-met","children":[]},{"id":"ci_088ca9fe95f2aa8cf86bc4d3cdc8c15c731ca0b848cbf4ebd637ed6db821e9b9","title":"For A31 (BYS)> = 7 condition is not met.","path":"/ideCAD/for-a31-bys-7-condition-is-not-met","children":[]},{"id":"ci_9e5638223bae45a44a3d2eaeb2ef538cde96b73d25503079465428215246ce5b","title":"For A32, (BYS)> = 6 condition is not met.","path":"/ideCAD/for-a32-bys-6-condition-is-not-met","children":[]},{"id":"ci_cbecb5ceeca552fbe4af9abe184563037e18f2c4c34e55727053b7dbd6cc22e7","title":"For A33, (BYS)> = 6 condition is not met.","path":"/ideCAD/for-a33-bys-6-condition-is-not-met","children":[]},{"id":"ci_a67820e6dbbeed9db371ed5f8aa003bbde8d73f70389fd182ae35f3dacfe6364","title":"Beamless (mushroom) floor systems should contain shear walls.","path":"/ideCAD/beamless-mushroom-floor-systems-should-contain-she","children":[]},{"id":"ci_f74f27db080ecfcde1102f8b8d853bcb5596705792728a8584baa569b9b4a2b4","title":"Beamless floor systems should be analyzed with a semi-rigid diaphragm.","path":"/ideCAD/beamless-floor-systems-should-be-analyzed-with-a-s","children":[]},{"id":"ci_36094b488af885dc522b3610f586f3ed5768e59dd917a8088267a56b8c970a91","title":"Analyze by choosing the \"semi-rigid diaphragm\" modeling.","path":"/ideCAD/analyze-by-choosing-the-semi-rigid-diaphragm-model","children":[]},{"id":"ci_acc823e16a6e2a36be22f707fb81e0f254396896f9ffbb03981337c438f2ed17","title":"Select \"Use seismic combinations for slab design\".","path":"/ideCAD/select-consider-earthquake-effects-in-slab-design","children":[]},{"id":"ci_55a9a0518d8df5b94c3018af62367250c4bc0e008563c0889a7e001fcaec104a","title":"Bond beam (Hollow) curtain adherence degree is not provided.","path":"/ideCAD/bond-beam-hollow-curtain-adherence-degree-is-not-p","children":[]},{"id":"ci_0d06bf352f2f08010842a3976463517d4fe9c6c3697478f3668829513193d582","title":"Rigid basement condition is not provided.","path":"/ideCAD/rigid-basement-condition-is-not-provided","children":[]},{"id":"ci_da8071b2ad789af5f497f542ee4632bfc0e5e0b0fd33122f6de25252ea484074","title":"∑Mdev / Mo <0.75 could not be achieved. Solve again with R = 6","path":"/ideCAD/mdev-mo-0-75-could-not-be-achieved-solve-again-w-1","children":[]},{"id":"ci_1d0cb61ab66d6ec30ecbaff0cd4dcf30ea683240ce13cf2a2ea388eb4ef472be","title":"∑Mdev / Mo <0.75 could not be achieved. Solve again with R = 7.","path":"/ideCAD/mdev-mo-0-75-could-not-be-achieved-solve-again-wit","children":[]},{"id":"ci_5b0af369953a4e124dc42c91396e3e62475046f0f5a7965b278d77e839c9ebf1","title":"0.40 <∑Mdev / Mo could not be achieved. DMS> = 3 could not be achieved.","path":"/ideCAD/0-40-mdev-mo-could-not-be-achieved-dms-3-could-not","children":[]},{"id":"ci_6f4aa49e2d68788fc773be3fbed4b9d8722698a2658f6c4acc45f0339faf9d7f","title":"Instead of R (4/5) R should be taken.","path":"/ideCAD/instead-of-r-4-5-r-should-be-taken","children":[]},{"id":"ci_403a5b4ea7eb5385a76a1aef8a1105f7e03ce000063c062b7c88ac3588c40f95","title":"R = R should be taken.","path":"/ideCAD/r-r-should-be-taken","children":[]},{"id":"ci_2d9e15b4231fae9322d0d13864e597514e647863bbef6998f0190fee364b6f69","title":"Could not provide >Mdev> = Mo / 6 for curtains.","path":"/ideCAD/could-not-provide-mdev-mo-6-for-curtains","children":[]},{"id":"ci_9dd40f4f4ed1f1138f2333cdc21b5a5caad42d46c8e1718ce603e3ec978c11a6","title":"Could not provide ∑Mdev> = Mo / 3 for curtains.","path":"/ideCAD/could-not-provide-mdev-mo-3-for-curtains","children":[]}]},{"id":"ci_b4b0b406429b59f9272d752599db285949ebde690be81f8669ba2b82bcb643f4","title":"Displacement and Irregularity Controls","path":"/ideCAD/displacement-and-irregularity-controls","children":[{"id":"ci_0d56ef7686405df08fbeb64db5526c3d40e7f6583e88703bf3b064a37a8bc3dd","title":"Relative floor displacement is high, increase system rigidity","path":"/ideCAD/relative-floor-displacement-is-high-increase-syste","children":[]},{"id":"ci_919b61efb261c302aa9f559470f39004120b0ad03456a794c9482be9208ec457","title":"B1 Irregularity not provided. Increase system rigidity","path":"/ideCAD/b1-irregularity-not-provided-increase-system-rigid","children":[]},{"id":"ci_241e6e7fd816fe8effdb2207f9d1789781466cff64e4d74aba44387b7e1d0a5c","title":"Earthquake overturning moment control could not be achieved","path":"/ideCAD/earthquake-overturning-moment-control-could-not-be","children":[]}]},{"id":"ci_6a8a9be68426333714665aa685cae7dd20e96ca26f9429b668c8ed7ff29af4de","title":"Earthquake Loads Affecting the Structure","path":"/ideCAD/earthquake-loads-affecting-the-structure","children":[{"id":"ci_b0c0119c9b38f1519e39219859d65495f1a635507e76b3f51dd90c47c4fa9948","title":"Insufficient number of modes","path":"/ideCAD/insufficient-number-of-modes","children":[]}]},{"id":"ci_8e372bc8cabf97bfed86f35da200b1238631638d2e129ebfd43896e856b1c859","title":"Material and Section Controls","path":"/ideCAD/material-and-section-controls","children":[{"id":"ci_574f509a09283fa507bd659e4601edee85f95f33275d13461c837634ac07bdd5","title":"Quality concrete less than C25 used","path":"/ideCAD/quality-concrete-less-than-c25-used","children":[]},{"id":"ci_d57e68bca7470261a54cdb8f37b6b43e5246f87155c7c79978990fafef47c6b6","title":"Concrete class cannot be lower than C25.","path":"/ideCAD/concrete-class-cannot-be-lower-than-c25","children":[]},{"id":"ci_131816bd7e907ed5bff09084ec92d66d630b383c35e48352235d1b76894ca749","title":"Used concrete grade cannot be superior than C80 quality.","path":"/ideCAD/used-concrete-grade-cannot-be-superior-than-c80-qu","children":[]}]},{"id":"ci_8271047e256bf761c89c0c6c2f7a56289bf8fd4c7af3f4d58800ae048e7b6d9c","title":"Slabs","path":"/ideCAD/slabs","children":[{"id":"ci_8d704a5ca7ffec4a9f6312f061e6f69959baa68f8d9e7b91e1666eb839613e17","title":"Insufficient Reinforcement on Slabs","path":"/ideCAD/insufficient-reinforcement-on-slabs","children":[]},{"id":"ci_3f86eac39c7fa353aafc331e0bd43a252f6c227f5b920bdfde3b40731d6af269","title":"Punching safety is not provided.","path":"/ideCAD/punching-safety-is-not-provided","children":[]},{"id":"ci_2fb2388a45a28f9340fb811f1084fb323df669c5aa90692b02ba309e4fe5fdad","title":"The rib height does not meet the requirement in gear upholstery.","path":"/ideCAD/the-rib-height-does-not-meet-the-requirement-in-ge","children":[]},{"id":"ci_2fd3d8911ab205ed68c4707f3c970106052e158f3b8795ca37cf73d97d1556d3","title":"The slab thickness does not meet the requirement.","path":"/ideCAD/the-slab-thickness-does-not-meet-the-requirement","children":[]},{"id":"ci_07164dd2c9d8520fcb512afa4fcdb04700d1f2499470ccb31899b80b6ac1d0d5","title":"Slab thickness is insufficient","path":"/ideCAD/slab-thickness-is-insufficient","children":[]},{"id":"ci_1c69f16d7b5b01e2695d4013e50305b4dbd2a08629dc642451e5492b25268e07","title":"Slab deflection limit exceeded","path":"/ideCAD/slab-deflection-limit-exceeded","children":[]},{"id":"ci_09bbed798efa6b0eaaac48121d80bc5206cd0347d1045c62688b952dcf4bdf7c","title":"Slab thickness for punching reinforcement min. Should be 25cm","path":"/ideCAD/slab-thickness-for-punching-reinforcement-min-shou","children":[]},{"id":"ci_5688acb4020fa75f0d19e0fcc123e430cb2d1737a05cc1928102eecdfc236437","title":"Slab Stress Check is not Provided","path":"/ideCAD/slab-stress-check-is-not-provided","children":[]},{"id":"ci_d3de55dcadcd4cd3948a360fda8afac6ccde15b65840365a97220c373a215b0a","title":"Rib offset of ribbed-waffle slabs cannot be more than 70cm (T.S. 500 11.3.2)","path":"/ideCAD/rib-offset-of-ribbed-waffle-slabs-cannot-be-more-t","children":[]},{"id":"ci_2ef884323abe78059da57e1d1e9b9fae38efc0625c9ad4068675b54ed5c35f7e","title":"Rib width of ribbed-waffle slabs cannot be less than 10cm (T.S. 500 11.3.2)","path":"/ideCAD/rib-width-of-ribbed-waffle-slabs-cannot-be-less-th","children":[]},{"id":"ci_c75e8bf493eb1138a2709ce58ff76a068614d64864c2f5dc810a75819ff03197","title":"Requires double reinforcement","path":"/ideCAD/requires-double-reinforcement","children":[]}]},{"id":"ci_e12ae196e427099518c1d185054e4395a6db5a7f1c52b15e4d30f62757d99941","title":"Beams","path":"/ideCAD/beams","children":[{"id":"ci_0bead344bfeaa37aacdd376d31fcb3cd71c218c9e61c034ead59cb5da5dffc95","title":"Insufficient Reinforcement on Beam","path":"/ideCAD/insufficient-reinforcement-on-beam","children":[]},{"id":"ci_d02fd6ea67903b895c6e9aa35f16cbec1ff119656a6cd5fd1bd84b4fdaec4302","title":"Maximum Percentages in Beam Exceeded.","path":"/ideCAD/maximum-percentages-in-beam-exceeded","children":[]},{"id":"ci_9bf6f42da05c2d247ea0732025c67827edfb07a280abe63929e6c38b0c42a80a","title":"Beam shear safety is not satistied","path":"/ideCAD/beam-shear-safety-is-not-provided","children":[]},{"id":"ci_e71294b609b105211429dd35a9a9cffc85c9daea7cc4d92c5f0b46272d880c92","title":"Insufficient rebar development length of beam","path":"/ideCAD/development-length-of-the-beam-with-the-column-cou","children":[]},{"id":"ci_1b6cad1c8ada382a4c408ab425c09093ee5f67427eddebcc0fabc33ae3c7dfea","title":"Beam width cannot be more than total of beam height and column/shearwall width.","path":"/ideCAD/beam-width-cannot-be-more-than-total-of-beam-heigh","children":[]},{"id":"ci_d5d6c2c4631bafad35b7f02d7b28e725ec8170e61c6ae1d8c35a19f059680a52","title":"Beam width cannot be less than 250mm.","path":"/ideCAD/beam-width-cannot-be-less-than-250mm","children":[]},{"id":"ci_a5018923f8297853ebebfe5a531a14f4ef3040321ff032f40b8efec5da6d26f9","title":"The beam height cannot be more than 3.5 times the beam width.","path":"/ideCAD/the-beam-height-cannot-be-more-than-3-5-times-the-","children":[]},{"id":"ci_16558f09ecdcdcbbc8c61f5e06e3d9665a2d3dd00d4a9872dc19b7fb68596856","title":"Column-beam shear safety condition is not provided.","path":"/ideCAD/column-beam-shear-safety-condition-is-not-provided","children":[]},{"id":"ci_45a7f8b93e6ad91df64d45fba92f80416a2f71a31f1504ae8f7ea241a4f831ac","title":"Beam exceeds Nmax","path":"/ideCAD/beam-exceeds-nmax","children":[]},{"id":"ci_0f94d0a9b5d52bd89ea9db07907647608e9e97cf08a6f0a6019b51e8f1481231","title":"Column reinforcement design rules are not satisfied for beam","path":"/ideCAD/column-reinforcement-design-rules-are-not-satisfie","children":[]},{"id":"ci_0e85121873c990c73a1575ac009c66c17bddc39014e185c2b797cce391c09b30","title":"Beam deflection limit exceeded","path":"/ideCAD/beam-deflection-limit-exceeded","children":[]},{"id":"ci_4ef771e364da72a40435ea39af49b28cd70e936572b0e3b5c3d707b473654631","title":"TS500 Balanced reinforcement ratio control not provided.","path":"/ideCAD/ts500-balanced-reinforcement-ratio-control-not-pro","children":[]},{"id":"ci_4f9e8ec55369d1f5a9c892d819cf0a44c984877b6fdeda74ad2536cd9be8ca15","title":"The beam height cannot be less than 300mm.","path":"/ideCAD/the-beam-height-cannot-be-less-than-300mm","children":[]},{"id":"ci_98e5910d72af9cd558e52bbd454c55d826297aea553e0149faa2cf6464d2456b","title":"Beam height cannot be less than 3 times the slab thickness","path":"/ideCAD/beam-height-cannot-be-less-than-3-times-the-slab-t","children":[]},{"id":"ci_2ee54f81c08c674755124529b935f2cc9255f534665b96c278e4a9a27ccca4b4","title":"Longitudinal rebar diameter cannot be used below Ø12 in beams.","path":"/ideCAD/longitudinal-rebar-diameter-cannot-be-used-below-1","children":[]},{"id":"ci_c84681bb9204fb29135fe916ca63e5a9f1aadc2d3dba7bffef366c22b6545348","title":"Beam width cannot be less than 200mm.","path":"/ideCAD/beam-width-cannot-be-less-than-200mm","children":[]},{"id":"ci_3f08b0818af5527bedd7e5bdd996ecfc45f0ed35e2fd0c46dba03e4e0d87dd13","title":"Insufficient Reinforcement on Coupling Beam","path":"/ideCAD/insufficient-reinforcement-on-coupling-beam","children":[]},{"id":"ci_ac2090af2550b4a6e0589ced6d3f6cb15e051f4c6dc010937f1f8dcf560e393e","title":"Beam Capacity > 1","path":"/ideCAD/how-can-i-subtract-beam-capacity-ratio-less-than-1","children":[]},{"id":"ci_08cc5117f690f942a1a3e6fbdef6319345167d2b2053a7b86757e89b3b3f1630","title":"Steel beam PMM ratio not satisfied.","path":"/ideCAD/steel-beam-pmm-ratio-not-satisfied","children":[]},{"id":"ci_08b22923722865c7925685dbec4ab7f1e53f781a099ad6b4142131ad5b9fd6b3","title":"Steel beam deflection limit exceeded.","path":"/ideCAD/steel-beam-deflection-limit-exceeded","children":[]},{"id":"ci_3599fd1d7291b991ea94493492f3b1ce1e8d1e5fb4bc21a576e6b95056c6e008","title":"Steel beam shear strength not satisfied.","path":"/ideCAD/steel-beam-shear-strength-not-satisfied","children":[]},{"id":"ci_6662a138a012c58de71433abe52805d5935740ab3a215d22d1645e7bf9c3f4ac","title":"Lateral bracing check is not satisfied","path":"/ideCAD/inadequate-lateral-bracing-of-steel-beam","children":[]},{"id":"ci_bfa2cb49677bd25149b5b3f38170b0ef961780d133d3ae6eb4ecba4950f8add8","title":"Steel beam section dimensions do not conform to Width-to-Thickness Ratios.","path":"/ideCAD/steel-beam-section-dimensions-do-not-conform-to-wi","children":[]},{"id":"ci_5ee61569cbeb1bf7947f22119c89bdea1e5123257765b99f0bac70fe5eaed5c2","title":"Crane beam strength not satisfied.","path":"/ideCAD/crane-beam-strength-not-satisfied","children":[]},{"id":"ci_0eba1672ec32e1a37fb96cd176d4058bc94c64fdbedb785320cdaed76eea5155","title":"Castellated beam strength not satisfied.","path":"/ideCAD/castellated-beam-strength-not-satisfied","children":[]},{"id":"ci_de691791ecac4531086b039fc2126ab47a80edb7bc1b4da2f315577d0aca8509","title":"Composite beam strength not satisfied.","path":"/ideCAD/composite-beam-strength-not-satisfied","children":[]},{"id":"ci_140f0473a802b7ed3a3d8e8483b04e38a1f2bed575b893d533fa49edebd3cb05","title":"Composite castellated beam strength not satisfied.","path":"/ideCAD/composite-castellated-beam-strength-not-satisfied","children":[]}]},{"id":"ci_2fc42d3c11eee7e7ad3df2f67b7e5c54bbbab3d4fe371b3ff3c41caa5c8b9ccb","title":"Columns","path":"/ideCAD/columns","children":[{"id":"ci_b25338bedbc2ef8aad36acfe9b6afaeefdf3c2142280909de5de45700f060125","title":"Axial Capacity Insufficient in Column","path":"/ideCAD/axial-capacity-insufficient-in-column","children":[]},{"id":"ci_55e27d7bc6ac6c903fad832b5f79fa1695de59705ef80a073efac5731d9bf52a","title":"Maximum Pursmail in Colon Exceeded.","path":"/ideCAD/maximum-pursmail-in-colon-exceeded","children":[]},{"id":"ci_676aa732ff66882adb1e705c3f7529f72d016fe21a1ba43dab62e1f72d0c9f3e","title":"Insufficient Reinforcement in Column","path":"/ideCAD/insufficient-reinforcement-in-column","children":[]},{"id":"ci_a4522e4373c1e2521b18282d30566fc32c795b4c8df8e7bb5c9dd5c3c0bef2a0","title":"Transverse reinforcement spacing error","path":"/ideCAD/transverse-reinforcement-spacing-error","children":[]},{"id":"ci_9bb8700af8537bca1be0f5dde41187c1806631303e09712819e0116f085b6ff1","title":"Column shear safety is not satistied","path":"/ideCAD/column-cutting-security-is-not-provided","children":[]},{"id":"ci_4430a9667f6c8bb88da4ac5b9e0fc3cad453a129b5dfb2abb0fe63eaa18ae95d","title":"Circular column diameter cannot be smaller than 350 mm.","path":"/ideCAD/circular-column-diameter-cannot-be-smaller-than-35","children":[]},{"id":"ci_c2d78f4f6c451ffce861e53ecae36ad5ee0cce935eea1d886aec317e305d5481","title":"The smallest dimension of the columns cannot be smaller than 300 mm.","path":"/ideCAD/the-smallest-dimension-of-the-columns-cannot-be-sm","children":[]},{"id":"ci_737df925d939d7ebd9eb05347ddda72992299fa1f756ba7c9d2683bd39c4c046","title":"Column longitudinal rebar diameter cannot be less than Ø14.","path":"/ideCAD/column-longitudinal-rebar-diameter-cannot-be-less-","children":[]},{"id":"ci_0711ebfc8acdf7f6cb3c67e4884b864f077f0bf3b6c9ea84e68181448ca7a992","title":"Circular column longitudinal rebar count cannot be less than 6.","path":"/ideCAD/circular-column-longitudinal-rebar-count-cannot-be","children":[]},{"id":"ci_8383884c935936c5c549551ec1b651a0aaf01dda805a08a0a6f0043f3dcb5f32","title":"αi < 0.70","path":"/ideCAD/ai-0-70","children":[]},{"id":"ci_2ccc759b896c85be65106b8775db4ab5f866ea1b95ac58c1479dbff35f2c38a8","title":"Column capacity ratio > 1","path":"/ideCAD/how-can-i-subtract-column-capacity-ratio-less-than","children":[]},{"id":"ci_2814e386ebb9973817cffa699f6af3198bde3863cf390301205d9a3ed633750f","title":"Steel column PMM ratio not satisfied.","path":"/ideCAD/steel-column-pmm-ratio-not-satisfied","children":[]},{"id":"ci_41482eb17c977dbde210b7f3fc419a800ee4ffb79c9f5ad9fb4ccb24d920a65c","title":"Steel column shear strength not satisfied.","path":"/ideCAD/steel-column-shear-strength-not-satisfied","children":[]},{"id":"ci_52fce7330aabe01a158f4046204378a12fa507ac9ccbf5855ba0e38ad7187b47","title":"Strong column/weak beam criteria is not fulfilled","path":"/ideCAD/strong-column-weak-beam-criteria-is-not-fulfilled","children":[]},{"id":"ci_bd2453f75ef5448aa3bd7f76c36fff70e2ca8e357f6316e4388e62d6b5df61c5","title":"Steel column section dimensions do not conform to Width-to-Thickness Ratios.","path":"/ideCAD/steel-column-section-dimensions-do-not-conform-to-","children":[]}]},{"id":"ci_9d6687e04865715e8df76c9d18082e4189b35f54e1f1c128e4beb41b60ff4f58","title":"Shearwalls","path":"/ideCAD/shearwalls","children":[{"id":"ci_6544155a05148cec9c38cfd99af85c74106b8f2c7a6ccb5e542b25d8336d9fb9","title":"Insufficient Reinforcement in Shearwall","path":"/ideCAD/insufficient-reinforcement-in-shearwall","children":[]},{"id":"ci_67708c9570b51c519dd4a0a9efca3db758b33b5727a226e773ed74a39951d21a","title":"Maximum Pursmail Exceeded Shearwall.","path":"/ideCAD/maximum-pursmail-exceeded-shearwall","children":[]},{"id":"ci_bfb3e01e2ba90f07979efcb9da3f090ec4b404e1d7aac0d0ba9cd8bafaab19c0","title":"Axial Capacity Insufficient in Shearwall","path":"/ideCAD/axial-capacity-insufficient-in-shearwall","children":[]},{"id":"ci_23da4620ea7d7c959b8e08890a56d706f340752a0da54147c0a9eda4b6ea9948","title":"Shearwall shear safety is not satistied","path":"/ideCAD/shearwall-shear-safety-not-provided","children":[]},{"id":"ci_232774d496b6ccc491f940a63acbb33c40014ec31d28078993995a2a6bad0f74","title":"Columns with a dimension ratio greater than 6 should be modeled as walls.","path":"/ideCAD/columns-with-a-dimension-ratio-greater-than-6-shou","children":[]},{"id":"ci_dbd155dada164d87e09e95e1e01479170cc26ea5ebdaae151d04683dd6ee47dd","title":"Shearwall thickness cannot be less than 1/20 of the floor height.","path":"/ideCAD/shearwall-thickness-cannot-be-less-than-1-20-of-th","children":[]},{"id":"ci_7b4230938676f6a1e051d65f438329edd8f64fc76883cce8391f821ef3074c94","title":"Shearwall thickness cannot be less than 1/16 of the floor height.","path":"/ideCAD/shearwall-thickness-cannot-be-less-than-1-16-of-th","children":[]},{"id":"ci_aac8b23a2ad8f995fb803724ddfb671c52cecb82fdf02c752ee7714be47cc38e","title":"The shearwall thickness cannot be less than 200 mm.","path":"/ideCAD/the-shearwall-thickness-cannot-be-less-than-200-mm","children":[]},{"id":"ci_7bcc2b702618991cf0ff102b3a0da42ca0c4c4d5f934ad9355c3fe2fb61e6565","title":"The shearwall thickness cannot be less than 250 mm.","path":"/ideCAD/the-shearwall-thickness-cannot-be-less-than-250-mm","children":[]},{"id":"ci_97909b3df000da6e31343ae6498cf081e7fd90042ce28d4678b6f0de46e45e09","title":"TBDY 7.6.6.2 there are shearwalls that do not meet the strong shearwall requirements","path":"/ideCAD/tbdy-7-6-6-2-there-are-shearwalls-that-do-not-meet","children":[]},{"id":"ci_02b536fdfea509ca2e983b2215bedd0f6167cbe759d03994f45427b7cc40158c","title":"The shearwall thickness cannot be less than 1/30 of the shearwall length.","path":"/ideCAD/the-shearwall-thickness-cannot-be-less-than-1-30-o","children":[]},{"id":"ci_c4253dd31831606dcafb28b6dfcb3029ed5f65d57f4517c0fbd9b35384eff513","title":"The upper floor shearwall is thicker than the lower floor shearwall","path":"/ideCAD/the-upper-floor-shearwall-is-thicker-than-the-lowe","children":[]},{"id":"ci_e6dd6bb0cbd2fa51e333c0b2f4f0ae5c77f36ba6e415177e3e5646b156486a84","title":"TBDY 7.11.5 in connection of elements with shearwall. conditions were not met.","path":"/ideCAD/tbdy-7-11-5-in-connection-of-elements-with-shearwa","children":[]},{"id":"ci_56e0216f84c77d1b5660b19ea857a87a60120f69d515049496a2f74d90c5e2a4","title":"The ratio of the thickness and length in the plan of shearwalls should be at least 6","path":"/ideCAD/the-ratio-of-the-thickness-and-length-in-the-plan-","children":[]},{"id":"ci_f29c90b3edcb79abc75bc7f2fb171e971e58a2fbf009d58b0a73a726f261a06c","title":"In the shearwall group, the size ratio must meet (1/6) condition","path":"/ideCAD/in-the-shearwall-group-the-size-ratio-must-meet-1-","children":[]},{"id":"ci_6d30bbcb8e1e751b46006564a5a1a6c08538b29e4c7ad2a3626576034da31475","title":"There are shearwall groups that do not meet the capacity ratio.","path":"/ideCAD/there-are-shearwall-groups-that-do-not-meet-the-ca","children":[]},{"id":"ci_f9786f70d5512e9301873948de4b615bab0b3b72299a13602eeb411320c18385","title":"Longitudinal rebar less than Ø14 cannot be used in shearwall head reinforcement area.","path":"/ideCAD/longitudinal-rebar-less-than-14-cannot-be-used-in-","children":[]},{"id":"ci_c84c7d96386995d20a3007b7048e08eeaa2ba7fa9ce613b8e9961cc5e8d8b200","title":"Shearwall capacity ratio > 1","path":"/ideCAD/how-can-i-subtract-shearwall-capacity-ratio-less-t","children":[]},{"id":"ci_abad5d3b7b1a1f13c19614fe8221189cc8dd3582a079332877a9f482c7c649b5","title":"Polygon shearwall capacity ratio > 1","path":"/ideCAD/how-can-i-subtract-polygon-shearwall-capacity-rati","children":[]},{"id":"ci_cfbb7f7a53e50755c111551267ee6ece4048b995ff4269c39683489fa72efc8b","title":"Shearwalls with coupling beam is not found","path":"/ideCAD/shearwalls-with-coupling-beam-is-not-found","children":[]},{"id":"ci_0d014e2083a1d5887f427e973622b264685125c636912ac6010646330501673e","title":"Friction Shear Failure","path":"/ideCAD/friction-shear-failure","children":[]}]},{"id":"ci_7df5c695add7b25b18d23c09b6588be4a9aef65a7d307564e5923ebb94a6f09c","title":"Strip Footings","path":"/ideCAD/strip-footings","children":[{"id":"ci_379ba5f5ac7e700780be5a1e8c3307ac1b02d3e7e9fcdd07aaa93406a17ebd2b","title":"Bearing capacity of strip foundation is insufficient.","path":"/ideCAD/ground-safety-on-strip-footing-negative","children":[]},{"id":"ci_619f3e6cb18d7611f617aca41757a57e831027348f5831ddff44887943f25132","title":"Insufficient Reinforcement on Strip Footing","path":"/ideCAD/insufficient-reinforcement-on-strip-footing","children":[]},{"id":"ci_b5af869350a3a93f0ca8caa6396ab2c5de0b9a43bf977e330c92e4ee9fa56890","title":"Cutting security of strip footing not always provided","path":"/ideCAD/cutting-security-of-strip-footing-not-always-provi","children":[]},{"id":"ci_7ced0bda4b5ed6948fdd8b0bff5390c38924f2980f97c383dfc1968587f1cee5","title":"Strip Footing Maximum Pursmail Exceeded.","path":"/ideCAD/strip-footing-maximum-pursmail-exceeded","children":[]},{"id":"ci_477109872b31b842f9d71864ed6bb0f180e05b30c68797415c3ff3994736425e","title":"Coupling beam dimensions cannot be less than 300 mm.","path":"/ideCAD/coupling-beam-dimensions-cannot-be-less-than-300-m","children":[]},{"id":"ci_3233933893ca9c1a2f38ad20ddbe7dc174c2011ea0237355d9d0bac6132d5f36","title":"Strip footing beam height cannot be less than 1/10 of the span.","path":"/ideCAD/strip-footing-beam-height-cannot-be-less-than-1-10","children":[]},{"id":"ci_27b2c8341c93bc58e6362d80f57778bc7f8443f5d4d1245377aecc70143e8180","title":"Foot height cannot be less than 200mm.","path":"/ideCAD/foot-height-cannot-be-less-than-200mm","children":[]}]},{"id":"ci_63cf4b67d28579542efb34b65dbb1954778d97c4bbc88e7d94ce2850637be3b3","title":"Raft Foundations","path":"/ideCAD/raft-foundations","children":[{"id":"ci_fe3207222c08e80719e76eb9e617c8a494ffd2fd6ac86340038f3b92ed7af648","title":"Insufficient reinforcement in raft foundation","path":"/ideCAD/insufficient-reinforcement-in-raft-foundation","children":[]},{"id":"ci_f7b8fcdb865daa7c53da38f8fce52b6c403340e26621640ebf2f93c2f844e715","title":"Bearing capacity of raft foundation is insufficient.","path":"/ideCAD/raft-foundation-ground-safety-negative","children":[]},{"id":"ci_874610e10ac2e79fae2809327320060450563320a24c2b970ed57fa5d8860e0e","title":"The raft foundation punching safety is not satisfied","path":"/ideCAD/the-raft-foundation-stapling-security-is-not-provi","children":[]},{"id":"ci_ed6062db8ec6e847b79cbb9509a47bc1e4a361975ce18a0a1d015517b93d7477","title":"The raft foundation thickness cannot be less than 30 cm.","path":"/ideCAD/the-raft-foundation-thickness-cannot-be-less-than-","children":[]}]},{"id":"ci_6b2594c28af495d07f4122ee1fb7716375aa2f166b7c45a975b404490000f1e6","title":"Single Footings","path":"/ideCAD/single-footings","children":[{"id":"ci_7e5c49082dabaf1b771494f328bdfb24ccbe944c084bd431114478ec8368639a","title":"Insufficient reinforcement on single footing","path":"/ideCAD/insufficient-reinforcement-on-single-footing","children":[]},{"id":"ci_db6206de1e697665238dc2b7118aaaa5908047828dd3e25a2567c9049ca04297","title":"Bearing capacity of single footing is insufficient.","path":"/ideCAD/ground-safety-on-single-footing-negative","children":[]},{"id":"ci_28d9a32007d304b41279b5bd5d7df8138a196400416f8968ac54468d8c3e9fdc","title":"Single footing size cannot be less than 70 cm.","path":"/ideCAD/single-footing-size-cannot-be-less-than-70-cm","children":[]},{"id":"ci_a10b749cfc7c2ec47727cc96f673a195af22e596421ebe9b0fed9a3bd62b3c2e","title":"Single footing area cannot be less than 1m².","path":"/ideCAD/single-footing-area-cannot-be-less-than-1m2","children":[]},{"id":"ci_e1c14f8babb6cfa93b74c5b139e780d7269d6a63ab719618623aeccff59406b5","title":"Single footing thickness cannot be less than 25 cm.","path":"/ideCAD/single-footing-thickness-cannot-be-less-than-25-cm","children":[]},{"id":"ci_de554dd23579508544159ef0aa15c5aae524207421560662f71bed11dc855e10","title":"Single footing thickness cannot be less than 1/4 of the cantilever opening.","path":"/ideCAD/single-footing-thickness-cannot-be-less-than-1-4-o","children":[]}]},{"id":"ci_57ff03c38926be08d3a13d3825fb6966c9504553fe3c8d575743d2eedc484eaa","title":"Steel Purlins, Steel Ties and, Secondary Steel Beams","path":"/ideCAD/steel-purlins-steel-ties-and-secondary-steel-beams","children":[{"id":"ci_3590abebfaad23cc5b3d72e818958d778d3ff1517121267173af6c3ba2267b21","title":"Steel purlin PMM ratio not satisfied.","path":"/ideCAD/steel-purlin-pmm-ratio-not-satisfied","children":[]},{"id":"ci_aa79a0e08da0aefd4fc86a4327c236cb1a83c8130ca3daa0751efbe4a8fca92f","title":"Steel purlin shear strength not satisfied.","path":"/ideCAD/steel-purlin-shear-strength-not-satisfied","children":[]},{"id":"ci_b5e8e97a4e3e1176d2c4e35b31fb143b89f141302bd8e399ba2834a3bb1c3184","title":"Steel purlin deflection limit exceeded.","path":"/ideCAD/steel-purlin-deflection-limit-exceeded","children":[]},{"id":"ci_8026dd0cab54fcf81f304f0249436ec7700159a8b46537ab2336fde1b4e5c52c","title":"Steel tie PMM ratio not satisfied.","path":"/ideCAD/steel-tie-pmm-ratio-not-satisfied","children":[]},{"id":"ci_b2ec031265fdee7270cb0e56c2aafb22a8c2e1380359b9e8815418ed94eb48f7","title":"Steel tie shear strength not satisfied.","path":"/ideCAD/steel-tie-shear-strength-not-satisfied","children":[]},{"id":"ci_dee19d3a6b3c84d8f840834ca29f8644c0d5bc435e1200a77cf5df5501a09f38","title":"Steel tie deflection limit exceeded.","path":"/ideCAD/steel-tie-deflection-limit-exceeded","children":[]},{"id":"ci_40bc1265b9b8ca6008de6c981ab1f7378e8fc6cef79a37a29c66176f0dbd3894","title":"Secondary steel beam PMM ratio not satisfied.","path":"/ideCAD/secondary-steel-beam-pmm-ratio-not-satisfied","children":[]},{"id":"ci_f3e04d5dbaba3c437a09ad7d1d8cff315cee0034a269b3a096bbafdbacd7b48a","title":"Secondary steel beam shear failure","path":"/ideCAD/secondary-steel-beam-shear-strength-not-satisfied","children":[]},{"id":"ci_74bdea3e1109ef98d65aa2419c67bae8292cababca837ae8e3b2d6992ce95780","title":"Secondary steel beam deflection limit exceeded.","path":"/ideCAD/secondary-steel-beam-deflection-limit-exceeded","children":[]}]},{"id":"ci_4ca061fb30dc7f94193112ac3707e304bdc25a552dd7e81a22a5fb26f42a0d70","title":"Steel Braces and Steel Trusses","path":"/ideCAD/steel-braces-and-steel-trusses","children":[{"id":"ci_8d51ddabfb2f8521840453a698a888d664e0df703f956584f8acabf80adc2fe9","title":"Steel brace axial force strength not satisfied.","path":"/ideCAD/steel-brace-axial-force-strength-not-satisfied","children":[]},{"id":"ci_d3035053e05c869f80cde9dacc32f3b5070c5f5a26d88313bac6d5e45deb7e25","title":"Steel brace slenderness check failure.","path":"/ideCAD/steel-brace-slenderness-check-failure","children":[]},{"id":"ci_3f2ee413c8d4b84817c3502de2409de4916e5123447f2227a431b945f3d649ed","title":"Steel brace section dimensions do not conform to Width-to-Thickness Ratios.","path":"/ideCAD/steel-brace-section-dimensions-do-not-conform-to-w","children":[]},{"id":"ci_f849bac714d7e8daaac5cf505905999bec0bbb06c652f2d4c748fb36211292b5","title":"Steel Brace ductility check failure","path":"/ideCAD/steel-brace-ductility-check-failure","children":[]},{"id":"ci_40ba93f5acbae5549e220def65813e27e1f5ee425857132493387fa54493bebd","title":"Steel truss axial force strength not satisfied.","path":"/ideCAD/steel-truss-axial-force-strength-not-satisfied","children":[]},{"id":"ci_1b69fefcb6cc141c5fff5db898d610482d98717b3c336a255114a8960fedaecc","title":"Steel truss slenderness check failure.","path":"/ideCAD/steel-truss-slenderness-check-failure","children":[]}]},{"id":"ci_06fbb45e2897b123526ea1dab023f33124904eee1b62f8829c9511ec21247110","title":"Steel Connections.","path":"/ideCAD/steel-connections","children":[{"id":"ci_e142103767f4a59806ab22aaa815c0a08c8ebcf16dfa02ed859ccc9c26d1a308","title":"Steel Connection geometry not satisfied.","path":"/ideCAD/steel-connection-geometry-not-satisfied","children":[]},{"id":"ci_683d9348a6fecb4a9e0afae6534578d5d5a15f8ac24fb83c5ea62da48ceec321","title":"Steel Connection strength not satisfied.","path":"/ideCAD/steel-connection-strength-not-satisfied","children":[]}]},{"id":"ci_592e8a13b24ae5f8311194b05fe813e7bec4b5df63015cf1ff197d55fb763208","title":"Analysis Controls","path":"/ideCAD/analysis-controls","children":[{"id":"ci_8ca31417d2dae2527f1737f193aa90d0378ae8cce1a98fb5b06667f3480bc9f4","title":"Cannot analyze.","path":"/ideCAD/cannot-analyze","children":[]},{"id":"ci_96acae1e21a1c3009c57a4ea7dfdefa0f1c9dad247d675191d86bd96e8721f9c","title":"The system cannot be resolved.","path":"/ideCAD/the-system-cannot-be-resolved","children":[]},{"id":"ci_2f464ea2e7a4b174c2e2c8883377e084c5b7a1f102131ade6c9848df6e30d2e6","title":"Unable to create mesh in flooring","path":"/ideCAD/unable-to-create-mesh-in-flooring","children":[]},{"id":"ci_b8b59646a7871a8dc1f19bc3aca6f2bae957157d6573d73f368d4a2620522b5f","title":"In order to determine the building performance, the system should be analyzed first.","path":"/ideCAD/in-order-to-determine-the-building-performance-the","children":[]},{"id":"ci_565f68271ca2e000c13d00d96b3c5544bb10cf0b52f398a561da6a2eed504641","title":"All floors are defined as rigid basement floors.","path":"/ideCAD/all-floors-are-defined-as-rigid-basement-floors","children":[]}]}]},{"id":"ci_5b519b00c28e6de53b5cd0d20a4e643af91042ff4448b1fb2d733a429d141574","title":"Quantities and Reports","path":"/ideCAD/quantities-and-reports","children":[{"id":"ci_76403687dc147823027c8fe7bb775a7e26ca039d297bc1674b25403ffe4f669c","title":"Quantity Report","path":"/ideCAD/quantity-report","children":[{"id":"ci_aa27e148093cf8e38029543ed04616fe884a0a3a14d09cc170c3e6d94e736a26","title":"Wall, Inner and Ceiling Plaster","path":"/ideCAD/wall-inner-and-ceiling-plaster","children":[]},{"id":"ci_0d55e6e8ca022866d567631cdec97215fb334a9a6524f42af27e975672c2e977","title":"Rebar, Formwork and Concrete Quantities","path":"/ideCAD/rebar-formwork-and-concrete-quantities","children":[]},{"id":"ci_ce48e993e1d7d84c600f4b1d55bca078d1e16b4c04d2d0eea93ade008a3a7f94","title":"Single-Part and Assembly Report","path":"/ideCAD/single-part-and-assembly-report","children":[]}]},{"id":"ci_64bbaba0c5d9929549cfe2934797e6968eeaa18f0f6dce9f98e368c25d456a14","title":"Components Report","path":"/ideCAD/components-report","children":[{"id":"ci_72745e55474fef3c8bbba1dfcaf40ef331dbd784be3d2fd0944f563f52b7ce63","title":"Designing a Component","path":"/ideCAD/designing-a-component","children":[]},{"id":"ci_2f56876207e2574bcce32574d1b304bfd3d7d8a7bc50e4503a197946a4acd2ad","title":"Saving/Loading a Component","path":"/ideCAD/saving-loading-a-component","children":[]},{"id":"ci_4be01daa1677889e0f00530e0407037aedab88848f920faff3f667f439e2ec38","title":"Assigning Components to Objects","path":"/ideCAD/assigning-components-to-objects","children":[]},{"id":"ci_4377b5110841f9d12528b0ecad7c4f84adabb6417d4daf230e2930156cf6319b","title":"Components Reports","path":"/ideCAD/components-reports","children":[]},{"id":"ci_71b370730c02c4539f3fe250e81ec9cb4435335af832087d76014c9e944c9bf5","title":"Example of Generating Component Report for Slab","path":"/ideCAD/example-of-generating-component-report-for-slab","children":[]},{"id":"ci_0323aaf11cef547cb14d076f411f078aa2fc0fe092fdd141f30441ce819692a0","title":"Example of Generating Component Report for Roof","path":"/ideCAD/example-of-generating-component-report-for-roof","children":[]},{"id":"ci_a85aba3e06218f1fe4d9f125c22a0611becde18c1eddf3f4281f2173f8ad65a1","title":"Construction Cost Estimating Reports","path":"/ideCAD/construction-cost-estimating-reports","children":[]},{"id":"ci_cd803929aaf2d5e8dc8cec19b44f07ae51a590fa86d81fd9df0625d26e522e0c","title":"Creating Quantity Report According to DIN277 and II BV Standard","path":"/ideCAD/creating-quantity-report-according-to-din277-and-i","children":[]},{"id":"ci_ec664fee4b681c2c92a4abd1aaf8f32e6dd81bec5d6ae9c396582372a93c0396","title":"Data Exchange with AMP and OSKA","path":"/ideCAD/data-exchange-with-amp-and-oska","children":[]}]},{"id":"ci_799b74e39052b6a8b10aead9b13ba7be529fc21690f4a5c58c367933f5f3c1bd","title":"Reporting","path":"/ideCAD/reporting","children":[{"id":"ci_e66f2aa12d1ab0d079ac5a6bb2e58557254199cef7dcbb9d8b74077cc3bee9a5","title":"Preparing Report","path":"/ideCAD/preparing-report","children":[]},{"id":"ci_138003edfdf9e0ed7a75f45062c29170747c47525b6f84208007038fc8000e48","title":"Select Reports","path":"/ideCAD/select-reports","children":[]},{"id":"ci_4220f7dd5d34e54c776d279e581450cbe1cbc556b5815b5f6e20e4fdff522ade","title":"General Reports","path":"/ideCAD/general-reports","children":[{"id":"ci_88a0c44c874f82d88f2ba5f58459d22c8b9c6a62124f46258b647fa5ac53f2e5","title":"Structure Summary Report","path":"/ideCAD/structure-summary-report","children":[]},{"id":"ci_3287d5c9a1d55813d8c96bd912988b604444019b1cf4ebc3b473ecf8e819713f","title":"Analysis Settings Report","path":"/ideCAD/analysis-settings-report","children":[]},{"id":"ci_c7c7132371a8500992f680117bb77f4768445708787805b33d2409bec28be153","title":"Concrete Design Settings Report","path":"/ideCAD/concrete-design-settings-report","children":[]},{"id":"ci_8a002f4a594a7f9aa16f6ecc6ea40c7501b10098beac724533611149808f5b39","title":"TBDY 2018 Seismic Parameters Report","path":"/ideCAD/tbdy-2018-seismic-parameters-report","children":[]},{"id":"ci_ee24a9641414471a27782c7e3df2de9bd719ad421736e210dee9a500f7141e79","title":"EQ Code General Report","path":"/ideCAD/eq-code-general-report","children":[]},{"id":"ci_0833c783000e5e914072a45a114a8e950147a75d4c62adbd1a800800169754d6","title":"Column-Beam Joint Safety Report","path":"/ideCAD/column-beam-joint-safety-report","children":[]},{"id":"ci_11700daf28ec5d993372466218b4f184f8ff29950e575f8267ca89b64a2acb2c","title":"TBDY (TSC) Non-structural Element Forces Report","path":"/ideCAD/tbdy-tsc-non-structural-element-forces-report","children":[]},{"id":"ci_433dc47434a57b87096d096e4ad3bb55edebf69d509e36e1b466d6db1eafcfd8","title":"A2 - A3 Irregularity Check","path":"/ideCAD/a2-a3-irregularity-check","children":[]},{"id":"ci_6936145ad435052eee6b8f8601fe2c9dc3b5947cde4e13c9695001e962c25391","title":"TBDY (TSC) Seismic Joint Thickness Report","path":"/ideCAD/tbdy-tsc-seismic-joint-thickness-report","children":[]},{"id":"ci_56f7ae560c677858c2ed595da627aba8378e5cb48b96d6218c0d738d44802ba7","title":"Dynamic Analysis Report","path":"/ideCAD/dynamic-analysis-report","children":[]},{"id":"ci_ce891746a67b57bcc56f0391895e88b4f2785dd830bfda32ab655c90242e4140","title":"Story Forces Report","path":"/ideCAD/story-forces-report","children":[]},{"id":"ci_ac0764d4509a19c073cf1a5185f842f9bddde4d89fc1bd0394ef9ce1600882a1","title":"Seismic Isolators Report","path":"/ideCAD/seismic-isolators-report","children":[]},{"id":"ci_50ea8ff02b091250965d4a10bed2673549b4b7fe2ca6e6c3f4260d6916ec8444","title":"Pushover Report","path":"/ideCAD/pushover-report","children":[]},{"id":"ci_b0ff82fc386bc7fce22b7b4f4e6387f063101aa5306f23d799b8786c2ba6be1c","title":"Structure Risk Analysis Report","path":"/ideCAD/structure-risk-analysis-report","children":[]},{"id":"ci_e422f458d5d4af4ee43a18b9e5ce7a442ebb5f79e80dafb536c9212675b30be0","title":"Linear Performance Analysis Report","path":"/ideCAD/linear-performance-analysis-report","children":[]},{"id":"ci_9ebbc5ce5a9be01b7e12c155576d4a493c58f52b0b7700ec99564b1cb7f196a9","title":"Moment-Curvature Reports","path":"/ideCAD/moment-curvature-reports","children":[{"id":"ci_581b1d46c151535086f943b206ef092875375f3992dff40d0241c4408a8be87f","title":"Column Moment-Curvature Report","path":"/ideCAD/column-moment-curvature-report","children":[]},{"id":"ci_e6bd08b6e35f9dd3c559b9f6d19a3ff3d392ae439c0fd7bee48b89f58fc63c18","title":"Beam Moment-Curvature Report","path":"/ideCAD/beam-moment-curvature-report","children":[]},{"id":"ci_69aac2fcf3da4c113a67c72612acbc363eeee8924a105c9ed4fc07eec06059b9","title":"Shearwall Moment-Curvature Report","path":"/ideCAD/shearwall-moment-curvature-report","children":[]},{"id":"ci_85ab823f1926694122d1b40e028cef175669d4a46033260bed19bc73894a296f","title":"Shearwall Core Moment-Curvature Report","path":"/ideCAD/shearwall-core-moment-curvature-report","children":[]}]},{"id":"ci_c3ea42262bebc3180aef05f9c080174ea8ee53dde2816673286893a16b826878","title":"TS EN 1991-1-4 Wind Loads Report","path":"/ideCAD/ts-en-1991-1-4-wind-loads-report","children":[]},{"id":"ci_76a6747cb5b10fa137d776091c5afde4140d5e35ce30cc6916516ca428df10a6","title":"Facade Scaffolding Report","path":"/ideCAD/facade-scaffolding-report","children":[]},{"id":"ci_f5b0dec737f17677640c4687af3003f0feed584a46f8512eedc588b6726b0407","title":"Concrete Formwork Report","path":"/ideCAD/concrete-formwork-report","children":[]}]},{"id":"ci_1eda9dc332b347049a39f47b6731fdaa0afb6e17b0d9ff0e8a144bf9d49bf6d9","title":"Getting Reports Based on Personnel","path":"/ideCAD/getting-reports-based-on-personnel","children":[{"id":"ci_60e523d235c20d62b8c097d380c22de66a9735ee2b7344dd7db53c3890f087c4","title":"Concrete Element Reports","path":"/ideCAD/concrete-element-reports","children":[{"id":"ci_9898d179cb2e6cfecc5e81cc7f5ebcf2ffd0e9840c1189005512cbc38738f1ff","title":"Slab General Report","path":"/ideCAD/slab-general-report","children":[]},{"id":"ci_7717192b3377a97189fcc51238572644e20327b8df0f7b2a451c34579a983d1a","title":"Slab Detailed General Report","path":"/ideCAD/slab-detailed-general-report","children":[]},{"id":"ci_81fdbea0992032f22b2ca5bee782059e81f935ed97f5c9b0cfc8407bcc907586","title":"Ribbed Slab General Report","path":"/ideCAD/ribbed-slab-general-report","children":[]},{"id":"ci_865805de17d4c67a89cd3d7a0b53956dda5a87ef80017969c51e42634bbfd660","title":"Waffle Slab General Report","path":"/ideCAD/waffle-slab-general-report","children":[]},{"id":"ci_b7c8205a2e4b615667108ce9cab52e4590abc463da68d06afdc843a71818a8e6","title":"Beam General Report","path":"/ideCAD/beam-general-report","children":[]},{"id":"ci_5543ba37e2f3035fb674ceced311f2873f62b63cce29b850f76107d4a1cb7bde","title":"Column General Report","path":"/ideCAD/column-general-report","children":[]},{"id":"ci_a342e82c790f8995899a9b99d07cf76227e5d10de199d0323241d7b0e1f71301","title":"Shearwall General Report","path":"/ideCAD/shearwall-general-report","children":[]},{"id":"ci_7800491a64229379da824ecff273ee884f92df3362ecaf2a955120a170490ae8","title":"Compound Shearwall Report","path":"/ideCAD/compound-shearwall-report","children":[]},{"id":"ci_8637986f5d650f92246a8fda3e0a047c891ac1aa180a953baf632f4d98d805c9","title":"Stair General Report","path":"/ideCAD/stair-general-report","children":[]},{"id":"ci_f6851ac3ea4832b70da4a2366a5657b5d86e414030775aaf5f33715a3165dd76","title":"Dome/Vault Results Report","path":"/ideCAD/dome-vault-results-report","children":[]},{"id":"ci_6ccace61488ca15cdda2b3820156d14dd495826ea62f566886a91d92401aa562","title":"Raft Foundation General Report","path":"/ideCAD/raft-foundation-general-report","children":[]},{"id":"ci_0379a838621f53bd650f1c45c8203ffb7cb08d42ae2400055a9755e5e1b8ea35","title":"Raft Foundation Detailed General Report","path":"/ideCAD/raft-foundation-detailed-general-report","children":[]},{"id":"ci_c33e9696bc73f4ea4717e12802f8f80fefa13e29edea19f075f012d5badcdaf5","title":"Strip Footing General Report","path":"/ideCAD/strip-footing-general-report","children":[]},{"id":"ci_98e6992b55f9d66e565d640f9e602d0cfcdee8707bfab2883b5fb1135523cc1e","title":"Single Footing Report","path":"/ideCAD/single-footing-report","children":[]},{"id":"ci_1c37e2969182a1470f6e2fffed5b93afd228ec4cc2e6e9b7831ead1bf96e9bb2","title":"Pile General Report","path":"/ideCAD/pile-general-report","children":[]},{"id":"ci_83c78a86d84136612a6b6d13ae8b6a2e72a2382a3be7f9211b5a3bbba111c5b0","title":"Foundation Tie Report","path":"/ideCAD/coupling-beam-report","children":[]},{"id":"ci_ae762e563807f4fc2f379f7f3505c161cb85bb6740ce1a91c14b2af724b035e7","title":"Retaining Wall Report","path":"/ideCAD/retaining-wall-report","children":[]},{"id":"ci_b0de8c5d51ed8eb877d4f662cd73deab1c17674412a5e447746f9f1c9d8a18b2","title":"Well Foundation Report","path":"/ideCAD/well-foundation-report","children":[]},{"id":"ci_1cbfceccdceae9ec26cb8203542f717fb780d30f9ffa7e9223a6c0bee4499934","title":"Predesign Results for Geotechnic Report","path":"/ideCAD/predesign-results-for-geotechnic-report","children":[]}]},{"id":"ci_0dfb0627f1d7e7e27dacdefc98048de158a79c0055b31d45cb6212f2cd66a3e2","title":"Steel Element Reports","path":"/ideCAD/steel-element-reports","children":[{"id":"ci_083c17975fd985c44b30a8d7db21b9bedf51ec8451f0d584cf9102066e279501","title":"Steel Column Report","path":"/ideCAD/steel-column-report","children":[]},{"id":"ci_92d1b5f212adbf3b933100184313ff6a6845196b8c9f49e5b9aa5073430c34a5","title":"Steel Beam Report","path":"/ideCAD/steel-beam-report","children":[]},{"id":"ci_c686cc91f025a1b1e1c77c3087d2e8ccf16207230e4d22c8e97d1a24c06b9a40","title":"Steel Secondary Beam Report","path":"/ideCAD/steel-secondary-beam-report","children":[]},{"id":"ci_a0939c2b8ab55335f3ba142f1eab68c1d0b73a9c6d5e8f08152b2ac4f72877ab","title":"Steel Purlin Report","path":"/ideCAD/steel-purlin-report","children":[]},{"id":"ci_3b41b57de7066777a78aaafbe70b19a19da94a32d6bc15a3e32c7f678bf5c17f","title":"Truss Report","path":"/ideCAD/truss-report","children":[]},{"id":"ci_ec5acc42e9e57b632f8aeb27b82455b86f4a7186282c51fb1f60d7a952f31e98","title":"Space Truss Report","path":"/ideCAD/space-truss-report","children":[]},{"id":"ci_60a94ee052bdae2e9084c1db5bc130f13088df9bf721b0baeec8c014a4c92f61","title":"Steel Joist Report","path":"/ideCAD/steel-joist-report","children":[]},{"id":"ci_23835fddf8fd27a7509c959b7661de167a182db97cf0dc4baf178d12184b31a8","title":"Space Purlin Reports","path":"/ideCAD/space-purlin-reports","children":[]},{"id":"ci_b35f27dc653656ec6bb77f8f7158aab1220b14e5c355fb4432f790db9b4941c3","title":"Concentric Brace Report","path":"/ideCAD/concentric-brace-report","children":[]},{"id":"ci_a31df8aa6ee59c689ec0faa5500c9a142791b6fba0371927bc4455738a2d6bb1","title":"Eccentric Brace Report","path":"/ideCAD/eccentric-brace-report","children":[]},{"id":"ci_c4167dbef4162c6c8f4a596d6051965e4068b7f6f7fbd292b5af92bd9c82ed5a","title":"Crane Design Report","path":"/ideCAD/crane-design-report","children":[]},{"id":"ci_a4be1e98ae9aaaf62dd0fc4a56d668ae23ec8e982b99d95a24af35e109f0bd11","title":"Composite Beam Design Report","path":"/ideCAD/composite-beam-design-report","children":[]},{"id":"ci_b8ba219901d340b56703f7e02b9bd2869ed1f9ae30a3936743c7f7458c8d5100","title":"Castellated Beam Design Report","path":"/ideCAD/castellated-beam-design-report","children":[]},{"id":"ci_c1fcb0126180b4270b63454e3cd3fd864637689a77fe11923e68e78b5bf38bae","title":"Composite Castellated Beam Desing Report","path":"/ideCAD/composite-castellated-beam-desing-report","children":[]},{"id":"ci_2839267554f25900f51b515ab8e203977e5bb462b03cd491e5e44da6cb9ec7cf","title":"Connection Design Summary Report","path":"/ideCAD/connection-design-summary-report","children":[]}]}]},{"id":"ci_c04360875fc89d652671bb585c0c75dad85b7fbd2d7d635d9241bdf2b00369e8","title":"Built-up Area & FAR Reports","path":"/ideCAD/built-up-area-far-reports","children":[]},{"id":"ci_f2e145aa02d36506a9fbf0b728f7a9951bb03189dd3080370e6d03ef51e70c52","title":"Printing the Report","path":"/ideCAD/printing-the-report","children":[]}]},{"id":"ci_2a0afbaea92b02663230678b9c9724232bafc76e87ce64af5fe1a61b0897f888","title":"Report Program","path":"/ideCAD/report-program","children":[{"id":"ci_bff07253a19c2be3bb48e2692d73a9e50850b8f16d7fa2b1ba04101d7d3e8778","title":"Unit Settings in Reports","path":"/ideCAD/unit-settings-in-reports","children":[]},{"id":"ci_9a7b923f977b95665071092aee6f37217659a04d970b8490142241969fd747c8","title":"Adding Company Picture to Reports","path":"/ideCAD/adding-company-picture-to-reports","children":[]},{"id":"ci_620f8f8c4ac4b2479fa3d111fde43cb98a2f39f9df572ece46600eb0b764897b","title":"Removing Company Picture in Reports","path":"/ideCAD/removing-company-picture-in-reports","children":[]},{"id":"ci_00b2e3abe963ba3ef97e8c52cdab3673d85f2b171f0fefea4d1c92ee87a5b545","title":"View of Report Pages","path":"/ideCAD/view-of-report-pages","children":[]},{"id":"ci_31c4c2585749893cc54c915d2aedf375590e3c0d8a4d35e378a25e766080897c","title":"Saving a Report","path":"/ideCAD/saving-a-report","children":[]}]},{"id":"ci_a07f474a22ce84fcc3f2a6ff1f911230dbc6b4cb1a258f745d5988c79beffe16","title":"Ground Area and Total Floor Area Calculations","path":"/ideCAD/ground-area-and-total-floor-area-calculations","children":[{"id":"ci_c6d452eefefd091d58e9523d846082f46f43a98211b85f4b5f9c5c02e44a3cd3","title":"Property Polygon Definition","path":"/ideCAD/property-polygon-definition","children":[]},{"id":"ci_cc48124d3d045fc210f1e4839da43cf031f0d398860b9899f442abd3e096b06d","title":"Property Polygon Settings","path":"/ideCAD/property-polygon-settings","children":[]},{"id":"ci_47296aea63743fee4cfd266eacb5e90e0649741a2378660e3cc3ddab02d31cbb","title":"Floor Area Settings","path":"/ideCAD/floor-area-settings","children":[]},{"id":"ci_57588184f7aec253dde1815d5b6f2786327665942e6f4b422e825c1ed6f7c02c","title":"Floor Area Calculation Settings","path":"/ideCAD/floor-area-calculation-settings","children":[]},{"id":"ci_e6a638849b34ca42d235943854bee98c09a9b210ab51ce96a0bced3290c292f8","title":"Define Floor Area","path":"/ideCAD/define-floor-area","children":[]},{"id":"ci_92dc9d53821e56864519cf17c3fb13b2e4b3c286a98bb08b48cbbfa516870917","title":"Example of Ground Area Calculation","path":"/ideCAD/example-of-ground-area-calculation","children":[]},{"id":"ci_ad6298dc563e45a7cc80b569d54b2db3f93828009b2c805b55c2c921beee6574","title":"Example of Total Floor Area Calculation","path":"/ideCAD/example-of-total-floor-area-calculation","children":[]}]}]},{"id":"ci_9e3425f5ebbbf6c7d61af87a106a6723e9cfc744e14fbf2b02b88d955a5bd72d","title":"Details and Layout Design","path":"/ideCAD/details-and-layout-design","children":[{"id":"ci_b033386fc7aac94a569155810cda211fa6d31ccb5ce4f68d45f6710b9ba8fe92","title":"Concrete Details","path":"/ideCAD/concrete-details","children":[{"id":"ci_f15aa5eb2d7f593cd44dd09ca51b35003e72c8cbd7962c36f1e416486f0b4ce0","title":"Formwork Plan","path":"/ideCAD/formwork-plan","children":[]},{"id":"ci_a82f803fbbcd4cdda7fd62c53b1d74621be1ab643839841d28441bf29cae1536","title":"Column Application Plan","path":"/ideCAD/column-application-plan","children":[]},{"id":"ci_468097390ef9ef37652af1b2d336b1aa15a587e176d8dd8e4018744e5e4edf46","title":"Shearwall Drawings","path":"/ideCAD/shearwall-drawings","children":[]},{"id":"ci_47100d28447233aad53718eee149ea855fab4af6b05b2facafdf3b2e46b9a2a1","title":"Column Vertical Drawings","path":"/ideCAD/column-vertical-drawings","children":[]},{"id":"ci_2566e986dfde21a57712dbf5ea2ecfe8c0a3d218a16b9b6a9441a2b4c874a620","title":"Beam Drawings","path":"/ideCAD/beam-drawings","children":[]},{"id":"ci_4b75922a766ed1ee1e2958a65498b8f09d9981a25f0f8edc332875b993ad1158","title":"Rib Drawings","path":"/ideCAD/rib-drawings","children":[]},{"id":"ci_f3b7d47c007a4784982f220f35ed4287e2c6285fc0396131fedff71fee79d943","title":"Waffle Drawings","path":"/ideCAD/waffle-drawings","children":[]},{"id":"ci_80b10625e46113dd8dc70f51e8b2b84489911022c7edbd5ee33b382747b75bb1","title":"Foundation Plan","path":"/ideCAD/foundation-plan","children":[]},{"id":"ci_a4805d417b72499639bcc2ea02c96d9dd117e8cb11c285b7a51f5652b5b27ccb","title":"Strip Foundation Drawings","path":"/ideCAD/strip-foundation-drawings","children":[]},{"id":"ci_3638f68048fc7b4111e98060e7e9c2c9aec377d049f32b4e4f2a5129b7077101","title":"Single Footing Drawings","path":"/ideCAD/single-footing-drawings","children":[]},{"id":"ci_bb851c6b1c273ab9ae1ce1ed15d701522165b5278019109c0997d02f6e8969b9","title":"Foundation Tie Drawings","path":"/ideCAD/connection-beam-drawings","children":[]},{"id":"ci_8883db60f8204b573afd50f228eaf3016cdb18d06c60da4f7dd3c2aa2ad77be0","title":"Column - Beam Joint Cross-Section","path":"/ideCAD/column-beam-joint-cross-section","children":[]},{"id":"ci_d365e1ac60d3c51dd773268fde91394a903c90ff4bf38caa7adf2b36b3d30b38","title":"Retaining Wall Drawings","path":"/ideCAD/retaining-wall-drawings","children":[]},{"id":"ci_bf30fb08ed41af76fe14b0ac6166a51c6692a5aab4f7d973b733b4c4d39da433","title":"Well Foundation Drawings","path":"/ideCAD/well-foundation-drawings","children":[]},{"id":"ci_117e38a689b7d69e48ba93f918a795bdee44e1c3bad8aae4c1d745ac07491980","title":"Stair Drawings","path":"/ideCAD/stair-drawings","children":[]},{"id":"ci_acbe11317977fecb58e383abb484ac0ab2506e9b24848c38aa6b789e14827e1f","title":"Pile Drawings","path":"/ideCAD/pile-drawings","children":[]},{"id":"ci_32c4b2fa074428add616c8af748b4a118840f845fcbdf5df3fe86c063e7eb600","title":"Dome Drawings","path":"/ideCAD/dome-drawings","children":[]},{"id":"ci_05bfda62d45895eb354fadcd22b0ec5cc59bc18d9504812b9254798fd47c674f","title":"Formwork Plan Section","path":"/ideCAD/formwork-plan-section","children":[]},{"id":"ci_86342ebfb26bac03c85d74a33bc2e77540b3120cb0324f2cfb26bbdd8a84cf6c","title":"Foundation Plan Section","path":"/ideCAD/foundation-plan-section","children":[]},{"id":"ci_a9b7387d3169b2a9d23c1172ad6f965c1e9b394ba9ad7d0fcb62feae20ef1f4d","title":"Structural Section Settings","path":"/ideCAD/structural-section-settings","children":[]},{"id":"ci_fa2504d04af2017dd79c861fc3f264b081d8f8c66188b6174d22657445f7b09d","title":"Drawing a Stirrup","path":"/ideCAD/drawing-a-stirrup","children":[]},{"id":"ci_e1fd29926bfb63393c0503a68e5f99b74d44f7525cdf9c5f789d3ac01d0c28c9","title":"Drawing a Crosstie","path":"/ideCAD/drawing-a-crosstie","children":[]},{"id":"ci_b76d48f9a37febf29f78a73942ea04953ef99215ba50d09696e89c8ac12bbdc8","title":"Rebar Numbering Settings","path":"/ideCAD/rebar-numbering-settings","children":[]},{"id":"ci_6bb5d4779f11e459995d7265e01ba311ff2d4d59df8dc1ed86d6de2dab9679a2","title":"Creating New Blocks for Annotations","path":"/ideCAD/creating-new-blocks-for-annotations","children":[]},{"id":"ci_a14c1cd74000c57cc056180b71bfadde743e57748719dbe3644e02c8ea0738d4","title":"Creating a New Annotations","path":"/ideCAD/creating-a-new-annotations","children":[]}]},{"id":"ci_d3a687a836060b58fe0a0d934659828164966abb4420b7d1de7539c089be4faa","title":"Steel Details","path":"/ideCAD/steel-details","children":[{"id":"ci_68ede387e1d1ef8866b4b96d20ce45e1fc0f1f1b18ba391f7bcd76b10fa0ac8f","title":"Steel Drawing Settings","path":"/ideCAD/steel-drawing-settings","children":[]},{"id":"ci_93de1238f0c7d5bcf1dfc91321960659b1762af43d22d8ded76733f65bf32ac1","title":"Single Part Drawings","path":"/ideCAD/single-part-drawings","children":[]},{"id":"ci_397d3c254505a8009b7a86dc22c70425af06490513b9652fcbcb6c02c44e07dd","title":"Assembly Drawings","path":"/ideCAD/assembly-drawings","children":[]},{"id":"ci_47785e1da6c29fa0e7194ddc3031393d5aa07421bc22c11801acab33b85687d0","title":"Assembly Drawings with Single Parts","path":"/ideCAD/assembly-drawings-with-single-parts","children":[]},{"id":"ci_09ab10e83738e705973b4ccce2e858936dbb84b21beebc1d3a38dc52453088d7","title":"Column Anchorage Drawings","path":"/ideCAD/column-anchorage-drawings","children":[]},{"id":"ci_724aa598f071839aa8b6a125d5adab31f1d869729cb0efc31ef0d2c0fd8721e3","title":"Application Plan Drawings","path":"/ideCAD/application-plan-drawings","children":[]},{"id":"ci_ad847fb68d6286204646433798682e0aee47b464d97abbf60f066919b3126640","title":"Axis and Frontal View Drawings","path":"/ideCAD/axis-and-frontal-view-drawings","children":[]},{"id":"ci_ff2cb649a0780e43acd999e631fc1f6361210042a54f8b864ebb967d29b9bb16","title":"Roof Plan Drawings","path":"/ideCAD/roof-plan-drawings","children":[]},{"id":"ci_7d1d9480920e3afa3c8a5bb97125892f6244250d9b9f4874e766f247a611d00d","title":"Truss Drawing","path":"/ideCAD/truss-drawing","children":[]},{"id":"ci_139072eff50030bf01ff7910184584c6d9597139b93d3aacf123f9a709707232","title":"3D Isometric View Drawings","path":"/ideCAD/3d-isometric-view-drawings","children":[]},{"id":"ci_fef9aa7a68b0fd3301cdf1769eb8c53b1fe96b410e8009965aa6c5174ed1ae33","title":"General Construction Drawings","path":"/ideCAD/general-construction-drawings","children":[]},{"id":"ci_722f47b08a3a332f257ee522c9ae1202da942e51403ff353daaba72cb3b0ab17","title":"General Construction Drawings w/Single Parts and Assembly","path":"/ideCAD/general-construction-drawings-w-single-parts-and-a","children":[]},{"id":"ci_428a16ebb3c388081fae95823355a6c18cb476ab4b35761cf9e3c4f6a276a3cc","title":"Select Point Detail Connections","path":"/ideCAD/select-point-detail-connections","children":[]},{"id":"ci_41bd143c0b738be70087c49e3f4a7a218330d4852d869f50a01ee2cb1217d3f8","title":"Point Detail List","path":"/ideCAD/point-detail-list","children":[]},{"id":"ci_35b2642c520aa37265e86affc01b31166c83c38daa66a48745aede08fa91d692","title":"Point Detail Editing","path":"/ideCAD/point-detail-editing","children":[]},{"id":"ci_946e38285bd409c1f9f46adeac23a0347f4d45863a2f7174a12dc0b8ebb78e4f","title":"Scaffolding Drawing","path":"/ideCAD/scaffolding-drawing","children":[]},{"id":"ci_8d6b85a947a24bc782d48f6cbc37445d2ad195cb429cafe783003a213cb78cfd","title":"Steel Numbering","path":"/ideCAD/steel-numbering","children":[]}]},{"id":"ci_ee81b46571227700b30e610628ed821628920063c37575d38ea1dbf1b6baafec","title":"General Arrangement Drawings","path":"/ideCAD/general-arrangement-drawings","children":[{"id":"ci_8d3077220e9038ab9dffacfd578520c3c65f01b208c9e89b0f4ef0820f68a62e","title":"Sectional Drawing","path":"/ideCAD/sectional-drawing","children":[]},{"id":"ci_b3e2f48da3796c4e9cb337b81d5dd78371622f4b0cb07d10fe23c7af0735cd58","title":"Elevation Drawing","path":"/ideCAD/elevation-drawing","children":[]},{"id":"ci_f2e09dc51300c40344e61f4552b9a4d0cc053f9093a1d1cc41d0149d804210d9","title":"Section/Elevation List","path":"/ideCAD/section-elevation-list","children":[]},{"id":"ci_fd10179e011edbea79867aca0165489087fdbd34e0a9ab7ec9c419b3f92b50cb","title":"Section/Elevation Settings","path":"/ideCAD/section-elevation-settings","children":[]},{"id":"ci_492db5f947a9b68f262a0f011e6295479228c4aa660519d1242b4690e620625a","title":"Giving the Floor Text and Zone Names in Sections","path":"/ideCAD/giving-the-floor-text-and-zone-names-in-sections","children":[]},{"id":"ci_2faf2890a255cd6f3e3d20abe03df6b49c31d296ea4f9f9589515c9f4c90e46f","title":"Editing Section Color and Hatch","path":"/ideCAD/editing-section-color-and-hatch","children":[]},{"id":"ci_a70aa4fa4800eccfbe533d801e3475bd2668357dee4c765359bb95f3c37b0dd6","title":"Getting a Section/Elevation of the Active Story or Selected Entities","path":"/ideCAD/getting-a-section-elevation-of-the-active-story-or","children":[]},{"id":"ci_a51e951f0339d3464d528c4438c491efa5003dfb65f91fde7fd60e96a87f8e64","title":"Entities to Exclude on Section","path":"/ideCAD/entities-to-exclude-on-section","children":[]},{"id":"ci_1e4416bc5f5c48d93a2ca4de20e02df3eb4c583d50e88930bd1dcb327586a257","title":"Show Axis in Sections and Elevations","path":"/ideCAD/show-axis-in-sections-and-elevations","children":[]},{"id":"ci_4918afe6329f98cf51a696f2f4ad7a4a76827853b18f6c7fe131fd0927e6de48","title":"Determining Section Depth","path":"/ideCAD/determining-section-depth","children":[]},{"id":"ci_8a9c2f60fad6e4cc0dbdd84af1c1c9c9e935228d79b84c03f1ab0d354d80f606","title":"Show Terrain Section Line in Sections and Elevations","path":"/ideCAD/show-terrain-section-line-in-sections-and-elevatio","children":[]},{"id":"ci_58d6fca6b3ba333a610e1dd75c0ffc64d84bd9d76f9370b7a4770b5715e8ce1d","title":"Generating a Vector Drawing","path":"/ideCAD/generating-a-vector-drawing","children":[]}]},{"id":"ci_0b53027e6afe2d1c8562587b724e38157451c90e88233d88c3b3552fd8e63718","title":"Layout Design","path":"/ideCAD/layout-design","children":[{"id":"ci_3425f6f9652629b6491b8082621fdb2eabf6eb11f1d57c112f87be74f411583a","title":"Create New Layout","path":"/ideCAD/create-new-layout","children":[]},{"id":"ci_f851d5a79e3714e97cd25ce0e7ccf764c778dbb617eb9d5e90f74a735469c661","title":"Layout Settings","path":"/ideCAD/layout-settings","children":[]},{"id":"ci_50768b0c584e3d651c087f32524e38eeb47b7ad79859928f8f10971fcb10d8de","title":"Layout Block Settings","path":"/ideCAD/layout-block-settings","children":[]},{"id":"ci_0fbd151f405ef509fef6d8e154fa1b1d6edf3928ed59b1be72ed2acfee58f855","title":"Create a Layout Block","path":"/ideCAD/create-a-layout-block","children":[{"id":"ci_c2acfbe0e8d52cfe152cedaf80e0a6b7a8b332afd5150e2fa1287f3eb67a4531","title":"New Layout Block-All Drawing","path":"/ideCAD/new-layout-block-all-drawing","children":[]},{"id":"ci_f8c500d7667bbeebdfc8549f75ad2c2078f7c22137e1b7a686466e4fdf1dc736","title":"New Layout Block-Rectangle","path":"/ideCAD/new-layout-block-rectangle","children":[]},{"id":"ci_617e012d6a9d08622eccc1d5d8b5fc2adf04929ca1f3fa21f56452a71d437c65","title":"New Layout Block-Polygon","path":"/ideCAD/new-layout-block-polygon","children":[]},{"id":"ci_c995a8b76c91f24ab8ee892235075b24662dbe1ad0d8a1f0416ddb29b1e0c7af","title":"New Layout Block-Path Polygon","path":"/ideCAD/new-layout-block-path-polygon","children":[]},{"id":"ci_135e1784ce6dcb5dc8b71028af28ba437d9169cb60e84f8f788514fc91caaf43","title":"New Layout Block-Circle","path":"/ideCAD/new-layout-block-circle","children":[]}]},{"id":"ci_ee2a153214dff97d73fced6afc9aeb54151265c04a1b94a91cebe289e3ac6320","title":"Insert Layout Block","path":"/ideCAD/insert-layout-block","children":[]},{"id":"ci_6af6a794529e3b24cdc921f9bafaa5e82285f1aa24f69b2246d6e293019c1828","title":"Update Layout Block","path":"/ideCAD/update-layout-block","children":[]}]},{"id":"ci_0d9a2e90bbedecc9ebb66140a487363afb59e6308f41e0b36798e92a537611dd","title":"Formwork Drawings","path":"/ideCAD/formwork-drawings","children":[{"id":"ci_73295e173cec8f1a508454805df0244d2c5d35c2acf3fccb38cfd0e114bbed46","title":"Scaffolding Plan Drawings","path":"/ideCAD/scaffolding-plan-drawings","children":[]},{"id":"ci_e09c39d33e788893a8b33553e1ba6785a7e624aabdc04539f6dcee55be37f377","title":"Selected Axis View Drawings","path":"/ideCAD/selected-axis-view-drawings","children":[]},{"id":"ci_f15b693945f93b81dd309c7433e424b01e1d5e9837911c5241fae42247b657d1","title":"Selected Detail Drawings","path":"/ideCAD/selected-detail-drawings","children":[]},{"id":"ci_68dd970c0a588da3ac983549c2b3dd9cc66e55af11f62f30c281f1b585a62520","title":"3D Isometric Drawings","path":"/ideCAD/3d-isometric-drawings","children":[]}]}]},{"id":"ci_67ce22a50b8223b81e8e092d0bb887ed9880f69dc1ebb814dd5c6b4ed22a58e2","title":"Troubleshoot","path":"/ideCAD/troubleshoot","children":[{"id":"ci_0190429dd73deb873da85fa71d3e124c5f15c91a5eb06b4bb8cf757e6bd93387","title":"Installation Issues","path":"/ideCAD/installation-issues","children":[{"id":"ci_6f0f7f5bba67ae0bc725f7d017961eb6c96a7007c2193264781d0506fe325f37","title":"I get a hasp error while running the ideCAD. What should I do?","path":"/ideCAD/i-get-a-hasp-error-while-running-the-program-what-","children":[]},{"id":"ci_0e5b97a7a594853dc464487ab71779ee8d3563744fc9ab3684c6589b8ea5e8b8","title":"I formatted the computer, where can I find the setups?","path":"/ideCAD/i-formatted-the-computer-where-can-i-find-the-setu","children":[]},{"id":"ci_46d169693da8952434fe0937fbdfc1cd5a4e2322cf7527fc06ebf35772961400","title":"Where can I download older versions?","path":"/ideCAD/where-can-i-download-older-versions","children":[]},{"id":"ci_b7c6bb24aa7427c81d987121614f44f8ab44ac153351abd15ea9ccf3662d0ffa","title":"I cannot install the ideCAD.","path":"/ideCAD/i-cannot-install-the-program","children":[]},{"id":"ci_21c23c5c4fd6f82bc28edaa0017e05d898a3ba8223956b2fc3883a0d1e328cd4","title":"I want to run the ideCAD. I get the message \"api-ms-win-crt-rutime-l1-1-0dll\" is missing from your computer and the ideCAD cannot be started. How can I run it?","path":"/ideCAD/i-want-to-run-the-program-i-get-the-message-api-ms","children":[]},{"id":"ci_d257f98c12fd83fd42128c84b362db547cfe6ed3bbe45584b1c3f5e9ffbefc63","title":"The ideCAD doesn't work, gives an error VCRUNTIME140_1.dll. How can I run the program?","path":"/ideCAD/the-program-doesn-t-work-gives-an-error-vcruntime1","children":[]},{"id":"ci_f53184d532625a996de38daf36775edc43683e07934a7d936db975973c91d6f3","title":"Is there a 32 bit version of ideCAD 10?","path":"/ideCAD/is-there-a-32-bit-version-of-idecad-10","children":[]},{"id":"ci_d58c42781b19888e7d444e42eb02952262118b73d5041197643ae51bbcad1a4d","title":"Which versions of Windows ideCAD works?","path":"/ideCAD/which-versions-of-windows-idecad-works","children":[]},{"id":"ci_c2fcf00b66ea3f96b05f71fe650f21761f43dd359db75eac9448594bb6e52a1a","title":"When I click to open the ideCAD, I get a direct stopped working error.","path":"/ideCAD/when-i-click-to-open-the-program-i-get-a-direct-st","children":[]},{"id":"ci_5acbaf6502642ebc5c050c096d7240212326b89271d09bc7087ff359445035de","title":"I can't run the demo version.","path":"/ideCAD/i-can-t-run-the-demo-version","children":[]},{"id":"ci_42d23e9a73e745e52b10cbcdefd041bae8232ce8b137e51d5f0de6ed0b81653d","title":"Encountered an improper argument warning appear, what should I do?","path":"/ideCAD/encountered-an-improper-argument-warning-appear-wh","children":[]},{"id":"ci_81dbe01cfb379d1db1618f2aae92b603bdf4da9b10964cb12e9d3cf9f15c4fc3","title":"The ideCAD opens very slowly and runs slowly.","path":"/ideCAD/the-program-opens-very-slowly-and-runs-slowly","children":[]},{"id":"ci_c324fb19a113dc59a7da87cdd7ab999e57629dcc5edf88cca2577441b59be923","title":"How to define network dongles on client computers from host computer?","path":"/ideCAD/how-to-define-network-dongles-on-client-computers-","children":[]},{"id":"ci_afc648740d34a24c041c5fef79ef7370c818fe539530aec6364fda4c7307b851","title":"When closing ideCAD it says \"Access denied. Possible cause File is read only\" what can I do?","path":"/ideCAD/when-closing-idecad-it-says-access-denied-possible","children":[]}]},{"id":"ci_c9db1ef2388512798c3665212fc6617295acda39ca54b67f3648829166b85885","title":"Graphics Card Issues","path":"/ideCAD/graphics-card-issues","children":[{"id":"ci_993998e344e8cf7911612a2fbb3a13e2536ed4a06dc568ac69a24bf008918e01","title":"The view is distorted and dark on the 3D display.","path":"/ideCAD/the-view-is-distorted-and-dark-on-the-3d-display","children":[]},{"id":"ci_e154bf622f63c4891a6ec60fa5e81afe1b65d9c0d2962c04316679b8a077bd95","title":"How can I speed up the screenshot is slow?","path":"/ideCAD/how-can-i-speed-up-the-screenshot-is-slow","children":[]},{"id":"ci_5356012a1e2ece5ded32cc6770dfbc11edbef0794afa924766eb80cdba816760","title":"Graphics card acceleration settings on remote desktop","path":"/ideCAD/graphics-card-acceleration-settings-on-remote-desk","children":[]}]},{"id":"ci_e3cebc73bd8836ad2033a183b8f2a0f61cf3c268c104c30bdb6b4ed26109fb09","title":"User Interface Issues","path":"/ideCAD/user-interface-issues","children":[{"id":"ci_4bbad3f433c759176fccfe12f03abda0cefefe1f6f63a38a8ad0bbc8b9468df2","title":"Even though I have chosen the without hatching one in the pattern options of the objects, the output is full?","path":"/ideCAD/even-though-i-have-chosen-the-without-hatching-one","children":[]},{"id":"ci_535e2d60ff46e6273b4a9ecc9b9fa3a7f16048e9765d688dd179ecc4c351c0a4","title":"The project was closed while working. How can I get it back?","path":"/ideCAD/the-project-was-closed-while-working-how-can-i-get","children":[]},{"id":"ci_ccf1c3acd940c8e1dce91a6f10e2a4f5a2b082a83db2ef2bfbea480c240aade3","title":"How can I back up the project I work on?","path":"/ideCAD/how-can-i-back-up-the-project-i-work-on","children":[]},{"id":"ci_a69ef3cbe9f31022e82773a0797d575c014cd5f48c8268995419ed17f2268438","title":"Incompatible file version error. How can I fix?","path":"/ideCAD/incompatible-file-version-error-how-can-i-fix","children":[]},{"id":"ci_a7d0bdf3f0e5ea0e8b765335a617ac390f93894673f476ba09994a999964789a","title":"Can I open my project made in the demo version in a licensed program?","path":"/ideCAD/can-i-open-my-project-made-in-the-demo-version-in-","children":[]},{"id":"ci_eca3429db4cc1ffcd7820f17c6a00b75b75ddab2e342b27d5141b86499e71dbb","title":"I started with a white background template. How can I activate the black background template colors.","path":"/ideCAD/i-started-with-a-white-background-template-how-can","children":[]},{"id":"ci_8643fdce614030db38ad144bf6749db42fc1ad1f4e3a01eadf7c5be822cd98ac","title":"Toolbar has disappeared, how can I get it back?","path":"/ideCAD/toolbar-has-disappeared-how-can-i-get-it-back","children":[]},{"id":"ci_32259a1c3dc326165015b2d888a83b1f188a40935a4fcd712bb6c1d6cb416e46","title":"How can I change the ribbon menu layout to the classic menu layout?","path":"/ideCAD/how-can-i-change-the-ribbon-menu-layout-to-the-cla","children":[]},{"id":"ci_ef518c00c992b77b6050152ec84f25b9a0861a396788fef279f9cda12b4db2f1","title":"How can I switch to the ribbon interface?","path":"/ideCAD/how-can-i-switch-to-the-ribbon-interface","children":[]},{"id":"ci_41fd5fc4dc35545a06177b00b5f2225084a4290c97a111fe43b82e033219aa37","title":"I lost the coordinate box. How can I get it back?","path":"/ideCAD/i-lost-the-coordinate-box-how-can-i-get-it-back","children":[]},{"id":"ci_b943ca2eea270c6dfa43fb4771042b072a77bec9edd19dab20729465009db0fc","title":"I cannot see my project in perspective / the objects I draw in the plan are not visible in perspective","path":"/ideCAD/i-cannot-see-my-project-in-perspective-the-objects","children":[]},{"id":"ci_c80d45400e9e096b3870dbd7e1332fe9fa77312dac9f10a90a68ea051b236ddb","title":"My model disappeared on the perspective screen. How can I find?","path":"/ideCAD/my-model-disappeared-on-the-perspective-screen-how","children":[]},{"id":"ci_48e6bd7bd28faebbc91d722d540a862c64c003e0f0be9bebec3a494f42e7e1a1","title":"Icons and text may appear small in the toollbar on 4K monitors.","path":"/ideCAD/icons-and-text-may-appear-small-in-the-toollbar-on","children":[]},{"id":"ci_dec29af1f36a579d116e693c895a0e9f8c8e64fb6e9a80434f5b2df603714c1b","title":"I cannot see the entire coordinate box.","path":"/ideCAD/i-cannot-see-the-entire-coordinate-box","children":[]}]},{"id":"ci_89f7726cf27fa0dc1d4263a0dab5411c14c68e4d74d358de685517bc66023681","title":"Modeling Issues","path":"/ideCAD/modeling-issues","children":[{"id":"ci_f9c09e43c302c676ba2032f19ffe0fb84d7069d993cbf8082cb02700e38f7f45","title":"Angled beams are not constantly scratching.","path":"/ideCAD/angled-beams-are-not-constantly-scratching","children":[]},{"id":"ci_e33cadc860798cae82f29eb9bfba322e439fe8496cfebac7e63bb0bb1b516259","title":"How do I transform a shearwall into a beam?","path":"/ideCAD/how-do-i-transform-a-shearwall-into-a-beam","children":[]},{"id":"ci_02784718905ef4e6dde03c1ec00e305fbcd37868f813fe8b55bfd23479ec9966","title":"How do I transform a beam to a shearwall?","path":"/ideCAD/how-do-i-transform-a-beam-to-a-shearwall","children":[]}]},{"id":"ci_2984cf0f7391b140f4551b5ed8ee12da2bf909e61df149908b69369a0b033f99","title":"Problems Getting Reports","path":"/ideCAD/problems-getting-reports","children":[{"id":"ci_aea789d46714718a438f22d743dc491110ef24db80e9546169dd66444dd77a37","title":"When I get a select report, I get the message “Encountered a sharing violation while a accessing…”.","path":"/ideCAD/when-i-get-a-select-report-i-get-the-message-encou","children":[]},{"id":"ci_d7f1ae0bbcef76b59acccef1c953245df685403affbee09df0bafc96e5be7789","title":"The ideCAD closes while receiving reports and footage.","path":"/ideCAD/the-program-closes-while-receiving-reports-and-foo","children":[]},{"id":"ci_0cebdd5e5877828f06d2c4630b9b04d79f01c6aa81969101dc8c27004b55988b","title":"I cannot save the report I created as PDF. How can I do it?","path":"/ideCAD/i-cannot-save-the-report-i-created-as-pdf-how-can-","children":[]}]},{"id":"ci_dbd1419e1391295c43295a856a53322aa42b1c15b5129ea367a711d0d9c73471","title":"Import/Export Problems","path":"/ideCAD/import-export-problems","children":[{"id":"ci_4a3a1289d7f449b5c7b2f6a05a442bcc571c61c62f0e475bb1871d5ee4bea294","title":"The drawings I imported from AutoCAD appear too big/small on my screen. Why?","path":"/ideCAD/the-drawings-i-imported-from-autocad-appear-too-bi","children":[]},{"id":"ci_ef25c3e49f56e056c2010690a1a4060ed60e9ec5811e042e740872e716a3bc0c","title":"The elements I created in the file I imported from AutoCAD are not displayed in the 3D window. Why?","path":"/ideCAD/the-elements-i-created-in-the-file-i-imported-from","children":[]},{"id":"ci_e7de516360259ad985e5affb1abe99794aa08e9968edf11e640a8e0545fe05e0","title":"I exported DWG, pen color settings did not come. How can I get it?","path":"/ideCAD/i-exported-dwg-pen-color-settings-did-not-come-how","children":[]},{"id":"ci_7898fd25846cb94288b2271fb2da74e659eb06d27473eb178f59505c30dab383","title":"Transferring pen thickness to the AutoCAD","path":"/ideCAD/transferring-pen-thickness-to-the-autocad","children":[]},{"id":"ci_074f82c21043726e0b3a744f588c0f1d48b924dda98fb90e3f0de3749677a49a","title":"How to fix slowness problems in Autocad while working on exported drawings?","path":"/ideCAD/how-to-fix-slowness-problems-in-autocad-while-work","children":[]},{"id":"ci_e30ad5e4c3efe2b01ad0f4cfb562026caf42153efe772342b4e8090c3c08327f","title":"When the project is exported as DWG, the \"Ø\" marks appear as \"?\" in the dwg file. How can I make it appear as \"Ø\"?","path":"/ideCAD/when-the-project-is-exported-as-dwg-the-marks-appe","children":[]}]},{"id":"ci_bc63213227af03f5fd31b2f7dcb2bb6298acb3500395e7aa70cc91974e261b04","title":"Architectural Design Frequently Asked Questions","path":"/ideCAD/architectural-design-frequently-asked-questions","children":[{"id":"ci_dcf74a348c24f4276c4c87826e094cd3a602346e86eb74c05f5c0cd0e4e19477","title":"My materials have disappeared on the perspective screen, what should I do?","path":"/ideCAD/my-materials-have-disappeared-on-the-perspective-s","children":[]},{"id":"ci_c480599d402899f3e25c707e77b5bead0541ffac4b6440013cd3c08924a08ea2","title":"I can't find the interactive camera, where is it?","path":"/ideCAD/i-can-t-find-the-interactive-camera-where-is-it","children":[]},{"id":"ci_7eed61d071708a801f839ada3c7a398d83272d89a02edb7509ce60745155eb7f","title":"I can't get a section. When I take a section, the page is blank/I get an over limit warning. What should I do?","path":"/ideCAD/i-can-t-get-a-section-when-i-take-a-section-the-pa","children":[]}]},{"id":"ci_28d4034be89b979e59836258ba54222e8b3f3093901df60f716d24b919f883fa","title":"Frequently Asked Questions for Steel Design","path":"/ideCAD/frequently-asked-questions-for-steel-design","children":[{"id":"ci_d28c6f39d2fc295e36d5b33adb7c94da0ac77f121476447fcc360ff600b0db33","title":"Should I choose the purlins as a part of the analysis system?","path":"/ideCAD/should-i-choose-the-purlins-as-a-part-of-the-analy","children":[]},{"id":"ci_0bea21935c421c7025b7d09e7364e4962d3cd3e148e44d695e9b29038cc0c53f","title":"Inclined Steel Column Definition","path":"/ideCAD/inclined-steel-column-definition","children":[]},{"id":"ci_0ac5c223fc9549030da400c9bf13617fc5748294a970d5cbb5fa63319054f5a3","title":"How Can I Make a Welded Connection?","path":"/ideCAD/how-can-i-make-a-welded-connection","children":[]},{"id":"ci_9e98547aac3b974c3e56a3a7240dae423f8b512fdacd3e55bd34aa450b4bf012","title":"How Can I Change Truss Connections?","path":"/ideCAD/how-can-i-change-truss-connections","children":[]},{"id":"ci_81b800b0af33cf4fd6ad62701691504943cda008b6b6920bbbf5505655b1af3d","title":"How can I change secondary beam connections in a group form?","path":"/ideCAD/how-can-i-change-secondary-beam-connections-in-a-g","children":[]},{"id":"ci_79bf545f52971d863c611e18d6d0284e32587bfd958cf4e493b9bf956a77d08b","title":"Steel Brace Definition","path":"/ideCAD/steel-brace-definition","children":[]},{"id":"ci_ce8386b7538d5c5ad1c982dfc56131009ade5413d55e04e0dc8265da1f399edd","title":"How do I know if there is overlapping of elements?","path":"/ideCAD/how-do-i-know-if-there-is-overlapping-of-elements","children":[]}]},{"id":"ci_1f783cd48c48939fa2bda9f016b241d4e2b304ef633500bf60a7038f6bc1cb02","title":"Concrete Design Frequently Asked Questions","path":"/ideCAD/concrete-design-frequently-asked-questions","children":[{"id":"ci_b1d3433a630a4e9d6df70014748349673fa3491f8b12999d7cb01c34f8fcf3b0","title":"How can I open a space for shearwalls?","path":"/ideCAD/how-can-i-open-a-space-for-shearwalls","children":[]},{"id":"ci_9d8e544e6a68b5b42f552406ddac7fb1aec1062fb498c0a05e679e18e4e800b3","title":"How can I define the elevator pit in raft foundation?","path":"/ideCAD/how-can-i-define-the-elevator-pit-in-raft-foundati","children":[]},{"id":"ci_1177ca49a1740d26e2b646be75d82cd4557fe6960dbd005b56bac4e59eeff50b","title":"How can I define sub-basement shearwalls?","path":"/ideCAD/how-can-i-define-sub-basement-shearwalls","children":[]},{"id":"ci_374f9248892fc748159b40b1d8ee36f5e81e68890fbb7ba7226ed840c8412d4e","title":"How do I define the intermediate landing beam?","path":"/ideCAD/how-do-i-define-the-intermediate-landing-beam","children":[]},{"id":"ci_26118584370d68f6331b50cff51e226d013ee678ac3ed5e025a790fb29315ff7","title":"How do I define a reverse beam?","path":"/ideCAD/how-do-i-define-a-reverse-beam","children":[]},{"id":"ci_c64b55766c7eca7bb904d2ba9702941102dbd7d83c4860639506567e2aeeb9bd","title":"How do I define external load on elements?","path":"/ideCAD/how-do-i-define-external-load-on-elements","children":[]},{"id":"ci_5b8fd136c807cf5a842ae630880f52fa8f1270707a20ec80a4862be59679e452","title":"There is B warning in my columns. How can I solve it?","path":"/ideCAD/there-is-b-warning-in-my-columns-how-can-i-solve-i","children":[]},{"id":"ci_85fc5e30d51fb29efa76eb02eb9f522394556f4dd960708446d8fd5a5591d9f7","title":"Double reinforcement warns in slab. How can I solve it?","path":"/ideCAD/double-reinforcement-warns-in-slab-how-can-i-solve","children":[]},{"id":"ci_697d0c0c2584c76cc88beaf6500994b91996b3ed95133b65682d1b2201aa74f5","title":"How Can I Subtract Capacity Ratio Less Than 1?","path":"/ideCAD/how-can-i-subtract-capacity-ratio-less-than-1","children":[]},{"id":"ci_c6867374ebf6323cba1d7228d3b816bb0567047e79db3bd5d985667b190d1170","title":"Should I solve dilated structures in a single project or in separate projects?","path":"/ideCAD/should-i-solve-dilated-structures-in-a-single-proj","children":[]},{"id":"ci_d934bae9b76b38d3b34fdd7f97582052abc188bdd4cc113e420eec16ae33c547","title":"I do not bent bars in the beams. How can I intervene?","path":"/ideCAD/i-do-not-bent-bars-in-the-beams-how-can-i-interven","children":[]},{"id":"ci_026cb7ea400b4292536feb463d29b0c977a8a2a39e4ac40688e9f7100733e991","title":"How do I rotate the structure?","path":"/ideCAD/how-do-i-rotate-the-structure","children":[]},{"id":"ci_41080fd240e85622dcf261d543347ae89587b9b639c38c86de6b03f2266fbc9e","title":"I can't get the stair drawings. Why?","path":"/ideCAD/i-can-t-get-the-stair-drawings-why","children":[]},{"id":"ci_94d4ca5c5dd7218d385fd70b1a0ba3cc7bab003cd26b9bded55638f9039e0f61","title":"How can I get the pool report and drawings?","path":"/ideCAD/how-can-i-get-the-pool-report-and-drawings","children":[]},{"id":"ci_0674db6c8e3a917a7096963f08b41def1f94959087cc8c023edb3f215dda65a7","title":"I am getting the error that the number of mods is insufficient in the project I am modeling for the pool. What can I do?","path":"/ideCAD/i-am-getting-the-error-that-the-number-of-mods-is-","children":[]},{"id":"ci_84489b77562a6452cd9f8d2b6a8cabd66f2d1676e1f1c03a33f7d38519764f71","title":"How do I analyze the dome with the building?","path":"/ideCAD/how-do-i-analyze-the-dome-with-the-building","children":[]},{"id":"ci_a9cbe08478dbec209e249790bee4a0534760d40c3566f5df36b033ded1764cc5","title":"How do I analyze the vault with the structure?","path":"/ideCAD/how-do-i-analyze-the-vault-with-the-structure","children":[]},{"id":"ci_a26747b72e14e3a9fa15e51e05bd58ef58688731660ac0740f46eee15551386c","title":"How do I solve the stair with the structure?","path":"/ideCAD/how-do-i-solve-the-stair-with-the-structure","children":[]},{"id":"ci_b794c113389e961b85d0c2b2cf472b22a07dd11021c314b86b292ec05bad559f","title":"How can I make a stepped footing design?","path":"/ideCAD/how-can-i-make-a-stepped-footing-design","children":[]},{"id":"ci_2f3cc76b20f18b5e22d297148a3ac37b5d2b900444e516f0d641bd8e73c0355b","title":"Does the program perceive column elements with a length more than 6 times the thickness as a shearwall?","path":"/ideCAD/does-the-program-perceive-column-elements-with-a-l","children":[]},{"id":"ci_71f41427dcd423e6020afefd23fccb3770bd14a78b95e8d17755bb7096be7d96","title":"With which command can I do scaffolding analysis and get reports?","path":"/ideCAD/with-which-command-can-i-do-scaffolding-analysis-a","children":[]},{"id":"ci_382303058ec9e4b9b8a0bd0e337927780312ff8004705cb484f42274c9e28361","title":"I'm getting an insufficient number of modes error. How can I fix?","path":"/ideCAD/i-m-getting-an-insufficient-number-of-modes-error-","children":[]},{"id":"ci_285c5d2169b14f8da1abf4599d4f07c0c671bf5e16dfee435c5a1860229e3724","title":"I am getting a raft foundation insufficient reinforcement error. How can I fix?","path":"/ideCAD/i-am-getting-a-raft-foundation-insufficient-reinfo","children":[]},{"id":"ci_9462c094e22f5de0973cfa114752e632fe46b148329b341b57cb4b0eaaaa5465","title":"Can I make a ribbed/waffle solution as a single console?","path":"/ideCAD/can-i-make-a-ribbed-waffle-solution-as-a-single-co","children":[]},{"id":"ci_9429db1c4a812c6194b4bd0a1c8bfbedbb372a8e60cb8ad7a97033106c6a6f11","title":"I'm getting an A1 and B2 irregularity warning. What should I do?","path":"/ideCAD/i-m-getting-an-a1-and-b2-irregularity-warning-what","children":[]},{"id":"ci_b86a7fc9664f785f22c9153099d6c16567f246fc1ebb3e3064801fb9c4f69ffe","title":"I am getting a B1 irregularity warning. What should I do?","path":"/ideCAD/i-am-getting-a-b1-irregularity-warning-what-should","children":[]},{"id":"ci_b665d86caca452a0d2265d34be17ab69d521c6ea13e065e24e796bcececc7b71","title":"Can we model and analyze columns on beams in the ideCAD?","path":"/ideCAD/can-we-model-and-analyze-columns-on-beams-in-the-p","children":[]},{"id":"ci_91bf136d6d3417f51ca23360760df975bd97d1b5b872d53b3b54fece6e431fa4","title":"A2-A3 irregularity in the structure? What should I do?","path":"/ideCAD/a2-a3-irregularity-in-the-structure-what-should-i-","children":[]},{"id":"ci_61fe0feffa490dad4fa1785c19e59883164a162ad2049d4bbe4e9d5e863dc0b4","title":"When should I solve the structure as semi-rigid and when fully rigid diaphragm?","path":"/ideCAD/when-should-i-solve-the-structure-as-semi-rigid-an","children":[]},{"id":"ci_8498f07b146af4e9d3829fa787fb83930a5d6ee3c1e46de8b6725bcec3452fa3","title":"I get a report, I get the warning \"The second order indicator value is high on any story. Increase the system rigidity\". How can I fix it?","path":"/ideCAD/i-get-a-report-i-get-the-warning-the-second-order-","children":[]},{"id":"ci_073db897c5ecee6dd495cbcbf035cf497a5c5e1574cf56ef6adbfcd14774a1e7","title":"In the Column Beam Joint Shear Capacity report, it appears that the columns in the rigid basement story have not been checked. Why?","path":"/ideCAD/in-the-column-beam-joint-shear-capacity-report-it-","children":[]},{"id":"ci_bd17dc0b84de8f321bce675e963ece978d3571cfe2d306db5aed359d1a189e86","title":"Can I move all stories of my project at once?","path":"/ideCAD/can-i-move-all-stories-of-my-project-at-once","children":[]},{"id":"ci_f9c90ecb5affbc53cd49ca470752880b074f7429a09ac6c1ef788c66171219f5","title":"Coordinate system and end force directions for shell elements","path":"/ideCAD/coordinate-system-and-end-force-directions-for-she","children":[]},{"id":"ci_2aa78c4a17a7fdffe171eb0cecc8bb14458a0e6848367bf3cc06f4eac1482539","title":"Definition of the Coordinate System and Element End Force Directions","path":"/ideCAD/definition-of-the-coordinate-system-and-element-en","children":[]},{"id":"ci_697da5b69ab129015910643d23130025f750c21a8febf290971a59685043d4a6","title":"How do I make the beam numbers sequentially starting from the top left on each story?","path":"/ideCAD/how-do-i-make-the-beam-numbers-sequentially-starti","children":[]},{"id":"ci_0a0181b5b47f4fff47952c89fa2e71f72f9e8c310b9be05284d69d49b89de848","title":"Why do the foundation base pressure values ​​not look the same as the values ​​in the report and the 3D visualization?","path":"/ideCAD/why-do-the-foundation-base-pressure-values-not-loo","children":[]},{"id":"ci_c3cf5595e468994458cddce3fac83730caefd9c5e2b0f6c19cabe123e3f39430","title":"If a wall is drawn with the wall command on the beam and the wall load is entered in the beam settings, which one is taken into consider?","path":"/ideCAD/if-a-wall-is-drawn-with-the-wall-command-on-the-be","children":[]},{"id":"ci_29cbd2d938a5fd715003b6440690b0275c25d4172a9e0b5b1e6af66bef4bce97","title":"Why are the site values from the AFAD map different from the site values calculated using the Offline option in the TDY wizard?","path":"/ideCAD/why-are-the-site-values-from-the-afad-map-differen","children":[]},{"id":"ci_356a914af100794dd675b26dcab2be2a7d1effb0b54c78c41253edc6abf2af00","title":"How is the calculation done when the \"Calculate the required reinforcement using the fiber model\" option is activated?","path":"/ideCAD/how-is-the-calculation-done-when-the-calculate-the","children":[]},{"id":"ci_87e0bd9b6e22e1a01b9969cdb27d3693116414a4b5b1a6d3d2d6e450a81f7fe8","title":"Why is there no warning when the capacity ratio is greater than 1.0?","path":"/ideCAD/why-is-there-no-warning-when-the-capacity-ratio-is","children":[]},{"id":"ci_a9217e22fd289da04b283d4b750bb8a878a685e285dfa120247ca7ea2ab5a94e","title":"What do Vd, Ve, Vr, Vemax and Ratio mean when the Purs, SG.Purs, Hes As, Ger.As and ExtraAs columns are fulfilled?","path":"/ideCAD/what-do-vd-ve-vr-vemax-and-ratio-mean-when-the-pur","children":[]},{"id":"ci_5ef5abdb7c8b8b826da47e6a1320a963da699a870eeb340083bec3ee982a8fb1","title":"What can be done to reduce Analysis+Design time?","path":"/ideCAD/what-can-be-done-to-reduce-analysis-design-time","children":[]},{"id":"ci_5708d2b29e7241bc1bdf0469a319e0474cff739c3b2290b9c6e427856156e106","title":"How Do I Fix Development Length (ab) Error?","path":"/ideCAD/how-do-i-fix-development-length-ab-error","children":[]},{"id":"ci_bd9d0dff39f48fee3396a9e273fe7e787a8707d98e4a709f11be5e76ca3af053","title":"Column-Beam joint shear safety (B) condition not satisfied. How can it be fixed?","path":"/ideCAD/column-beam-joint-shear-safety-b-condition-not-sat","children":[]},{"id":"ci_af29b99f80b65033278533f3fcbaf8b34bc90f970b030c22e9740180331f6973","title":"How Can I Fix B1 Type Irregularity?","path":"/ideCAD/how-can-i-fix-b1-type-irregularity","children":[]},{"id":"ci_354302375c3e138ee5e1a5f0141dc5e6cf8f9a564748eea692d98de5e62e0948","title":"How is Fiber Reinforced Polymer (FRP) defined?","path":"/ideCAD/how-is-fiber-reinforced-polymer-frp-defined","children":[]},{"id":"ci_44fac11c3daf30d30eb4a7d9b7769435907a759b5ce5e464559c6901c9fb4237","title":"What Can Be Done When Negative Ground Stress Occurs?","path":"/ideCAD/what-can-be-done-when-negative-ground-stress-occur","children":[]},{"id":"ci_c132461281974e92f83c972afd6dc68b98c68df084ef1c3878f143eb025838d4","title":"How to Design High-Rise Buildings","path":"/ideCAD/how-to-design-high-rise-buildings","children":[]},{"id":"ci_66bd862e169b86730ff5fc3a404b40f069ebeb098d5dba3b3bcaa419d959efc3","title":"Is it correct to get a report by making story copying after the analysis?","path":"/ideCAD/is-it-correct-to-get-a-report-by-making-story-copy","children":[]}]},{"id":"ci_ccbd520c89d895cc1be667e10a066d68378713d962716897090a4e260e35d92d","title":"Customers Portal Related Questions","path":"/ideCAD/customers-portal-related-questions","children":[{"id":"ci_0ffc55de1505c7b40d769a331efb12d437bc6f59abcc1b340d203d132578a885","title":"How to create a password for the customers portal?","path":"/ideCAD/how-to-create-a-password-for-the-customers-portal","children":[]},{"id":"ci_3374d507598da5b78ba15325f7972a24afba013904724498518745a792482673","title":"The invitation mail has expired. How do I create a password?","path":"/ideCAD/the-invitation-mail-has-expired-how-do-i-create-a-","children":[]},{"id":"ci_9d39af00fb4f82733f0c2a610c9516c46eef166a7300591ec30e87ac27c68a6b","title":"How to reach the customers portal?","path":"/ideCAD/how-to-reach-the-customers-portal","children":[]},{"id":"ci_9df91641a640739e44e63ad354ff61b7db635c34cbd51e9a9a7bce5dbf3889a4","title":"I forgot my password, how do I reset it?","path":"/ideCAD/i-forgot-my-password-how-do-i-reset-it","children":[]},{"id":"ci_5514fa92bc12b1609273568a5bb30f683c5bca8ce372b1cd1bc67181c375eeee","title":"How to ask a question in the customers portal?","path":"/ideCAD/how-to-ask-a-question-in-the-technical-support-cen","children":[]},{"id":"ci_5d0e4c5a9d620ce05f5337b9a9489d3f9a8649580aa1231caabd69c9d84fad6b","title":"How to add a project file to the customers portal with cde extension?","path":"/ideCAD/how-to-add-a-project-file-with-cde-extension-to--1","children":[]},{"id":"ci_6172ead12294b630622c4f257f805b368a2e3e14092f3871b8b21b01394c1a8e","title":"How can I reach the questions I asked before in the customers portal?","path":"/ideCAD/how-can-i-reach-the-questions-i-asked-before-in-th","children":[]},{"id":"ci_bb7751ea2fb0e0e2ac83fd162c21fa66a809bbfbe83e8f0b43633209758e87f3","title":"How do I upload a file to the question I asked earlier in the customers portal?","path":"/ideCAD/how-do-i-upload-a-file-to-the-question-i-asked-ear","children":[]},{"id":"ci_0b787aa0676618015049ed71710cef4cff2808309c421b6f39ab93ea4c0581af","title":"How do I see other users' questions in the customers portal?","path":"/ideCAD/how-do-i-see-other-users-questions-in-the-technica","children":[]},{"id":"ci_d3545ab2e1098bb84f3ed66f55c7a150bb4c47acd119f2ca72ebf85e1ff447cc","title":"How do I make sure other users don't see the questions I'm asking?","path":"/ideCAD/how-do-i-make-sure-other-users-don-t-see-the-quest","children":[]}]},{"id":"ci_21fd8693650d11e0021463092954bdd66379f711a50c38a1b8e63becd11fe5ba","title":"Forum Related Questions","path":"/ideCAD/forum-related-questions","children":[{"id":"ci_9db8a05301ea1d231b8b5c330345a30d0587021ccbbb91daff6fb806e194b72d","title":"How to add a project file with cde extension to the forum?","path":"/ideCAD/how-to-add-a-project-file-with-cde-extension-to-th","children":[]}]},{"id":"ci_af6806ad672322db7426d908d4ed8858dca8958351897aaa1d95af1032c55764","title":"Questions About ideYAPI OneClick","path":"/ideCAD/questions-about-ideyapi-oneclick","children":[{"id":"ci_b36a52431f1df5fb83a100665628cad086a288955e0917708c6e4aa7388a479a","title":"ideYAPI OneClick screen appears white, I cannot sign in.","path":"/ideCAD/ideyapi-oneclick-screen-appears-white-i-cannot-sig","children":[]}]}]},{"id":"ci_87e1aed21b2392e6e6235c5100eb94c83c79e53b8840c3731f5cc9cf5e5e6ef2","title":"Limitation of Liability","path":"/ideCAD/limitation-of-liability","children":[]}]